Lenovo ThinkStation P500, ThinkStation P510, ThinkStation P700, ThinkStation P710, ThinkStation P900 RAID Hardware Configuration [en, ar, bg, cs, da, de, el, es, fi, fr, he, hr, hu, it, ja, ko, nb, nl, pl, pt, pt, ro, ru, sh, sk, sl, sr, sv, th, tr, uk, zc, zh]

...
ThinkStation P500/P510, P700/P710, and P900/P910 RAID Hardware Configuration
Ve rsi on 1. 1
1. Introduction
The introduction of the new ThinkStation P500/P510, P700/P710 and P900/P910 platforms brings with it several new storage options that are designed to increase the storage capacity and performance of the system. As with previous ThinkStation platforms, P500/P510/700/P9710/P900/P910 will continue to support the standard SATA and SAS storage technologies to provide users with a wide variety of data storage solutions. This document will highlight the available SATA, SAS, and RAID storage solutions offered on this latest generation of ThinkStations as well as provide valuable information about how users can configure these solutions to provide the best performance possible.
2. Hard Drive Controllers used on ThinkStation P500/P510,
Maximum Number of Drives
4 (2 drives per BCA)
Connection Method
Tool-less via BCA
Drive Locations
Drives install into FLEX Bays via FLEX Tray. One drive per FLEX bay. Drives install in upper () position labelled P1 & P2.
Hardware Required
BCA-S* or BCA-P
Drives Types Supported (6Gb/s)
3.5” SATA HDD (7200rpm)
3.5” SSHD (Hybrid)
2.5” SATA SSD
RAID Level Support
RAID 0 RAID 1 RAID 5 RAID 10
Drive Speed
Maximum speed is 6Gb/s.
P700/P710, P900/P910
ThinkStation P500/P510, P700/P710 and P900/P910, have several hard drive controller options that can be used to support a wide variety of drive configurations. Selecting the correct controller will directly depend on the number and type of drives a user wants to support in their specific configuration. RAID requirements also play a big part in determining which controller to choose when configuring your ThinkStation.
Onboard Intel SATA Controller
The “default” controller on P500/P510, P700/P710, and P900/P910 is the onboard Intel SATA controller, sometimes called S-SATA. This controller is capable of supporting up to four SATA HDDs/SSDs at Gen3
(6Gb/s) max theoretical bandwidth. It’s important to note that only SATA devices are supported with
the onboard Intel controller. RAID modes 0/1/5/10 are supported as well. Refer to P500-P510-P700- P710-P900-P910 How to Create and Configure RAID Arrays” for more info about how to configure RAID arrays.
Unlike previous ThinkStation systems that used onboard Intel SATA controllers, all three platforms have support for the same number of drives with this controller. Connection methods do vary by platform.
P900/P910 SATA Support via Intel Onboard S-SATA Controller
*BCA-S comes standard in P900/P910.
Maximum Number of Drives
4
Connection Method
Manual plug for data and power using standard cabling methods
Drive Locations
Drives install into FLEX Bays via FLEX Tray. One drive per FLEX bay.
Hardware Required
SATA HDD cable(s), HDD Power cable
Drives Types Supported (6Gb/s)
3.5” SATA HDD (7200rpm)
3.5” SSHD (Hybrid)
2.5” SATA SSD
RAID Level Support
RAID 0 RAID 1 RAID 5 RAID 10
Drive Speed
Maximum speed is 6Gb/s.
Maximum Number of Drives
4 (2 drives per BCA)
Connection Method
Blind Connect Assembly (BCA)
Drive Locations
Drives install into FLEX Bays via FLEX Tray. One drive per FLEX bay. Drives install in upper () position labelled P1 & P2.
Hardware Required
Up to two BCA-S or BCA-P.
Drives Types Supported (6Gb/s)
3.5” SATA HDD (7200rpm)
3.5” SSHD (Hybrid)
2.5” SATA SSD
RAID Level Support
RAID 0 RAID 1 RAID 5 RAID 10
Drive Speed
Maximum speed is 6Gb/s
P500/P510/P700/P710 SATA Support via Intel Onboard S-SATA Controller using Manual HDD Connect
P500/P510/P700/P710 SATA Support via Intel Onboard S-SATA Controller using Blind Connect Assembly (BCA)
Optional LSI SATA/SAS RAID controllers
ThinkStation P500/P510, P700/P710, and P900/P910 platforms utilize discrete controllers in order to add support for SAS drives. These controllers offer support for both SATA and SAS drives, support more drives than the standard onboard controller and in some cases offer increased performance and reliability capabilities.
LSI SATA/SAS RAID FLEX Adapter
Specialized FLEX adapter that only installs to Lenovo FLEX Connectors Capable of supporting up to 8 SATA or SAS drives using Blind Connect Assemblies Uses LSI SAS3008 IOC controller Support for RAID 0/1/5/10 for both SATA and SAS formats Support for up to 12Gb/s Does not occupy a traditional PCIe slot, allowing for additional system expansion Utilizes mini-SAS HD connectors to connect the adapter to BCA For the P500/P510 and P700/P710, the FLEX Adapter may utilize a manual connect option by
using the LSI to HDD Manual Tray Cable to avoid using Blind Connect Assemblies. If the LSI to HDD Manual Tray Cable is used, then the FLEX Adapter can only support up to 4 SATA, SAS or SATA and SAS drives.
LSI 9364-8i PCIe SATA/SAS ROC Adapter
Standard PCIe x8 card Capable of supporting up to 8 SATA or SAS drives using Blind Connect Assemblies Uses LSI SAS3108 ROC controller Support for RAID 0/1/5/10 for both SATA and SAS formats Support for up to 12Gb/s Utilizes mini-SAS HD connectors to connect the adapter to BCA Increased performance as all RAID workload is handled on card, instead of being offloaded to
system (CPU)
Includes support for optional SuperCap for added reliability in case of power outages. For the P500/P510 and P700/P710, the FLEX Adapter may utilize a manual connect option by
using the LSI to HDD Manual Tray Cable to avoid using Blind Connect Assemblies. If the LSI to HDD Manual Tray Cable is used, then the FLEX Adapter can only support up to 4 SATA, SAS, or SATA and SAS drives.
Maximum Number of Drives
8 (4 drives per BCA)
Connection Method
BCA
Drive Locations
Drives install into FLEX Bays via FLEX Tray. Up to two drives per FLEX Tray*
Hardware Required
LSI SATA/SAS RAID FLEX Adapter or LSI 9364-8i ROC Up to two BCA-S or BCA-P
Drives Types Supported
3.5” SATA HDD (7200rpm)
3.5” SSHD (Hybrid)
2.5” SATA SSD
2.5” SAS HDD (15000rpm, 12Gb/s)
2.5” SAS SSD (12Gb/s)
RAID Level Support
RAID 0 RAID 1 RAID 5 RAID 10
Drive Speed
Maximum speed is 12Gb/s
Maximum Number of Drives
4
Connection Method
LSI to HDD Manual Connect Cable
Drive Locations
Drives install into FLEX Bays via FLEX Tray. One drive per FLEX tray.
Hardware Required
LSI SATA/SAS RAID FLEX Adapter or LSI 9364-8i ROC LSI to HDD Manual Connect Cable*
Drives Types Supported (6Gb/s)
3.5” SATA HDD (7200rpm)
3.5” SSHD (Hybrid, 7200rpm)
2.5” SATA SSD
2.5” SAS HDD (15000rpm, 12Gb/s)
2.5” SAS SSD (12Gb/s)
RAID Level Support
RAID 0 RAID 1 RAID 5 RAID 10
Drive Speed
Maximum speed is 12Gb/s.
P500/P510/P700/P710/P900/P910 SATA and SAS Support via LSI Controllers Using Blind Connect Assembly
*Some physical limitations apply
P500/P510/P700/P710 SATA and SAS Support via LSI Controllers using Manual HDD Connect
*The LSI to HDD Manual Tray Cable is only supported on P500/P510 and P700/P710
3. How to Utilize the Onboard Intel S-SATA Controller
P900/P910
In the P900 system, drives are always connected through the use of Blind Connect Assemblies (BCA). When using the onboard Intel S-SATA controller, up to two drives can be connected per BCA. This gives P900 support for up to 4 drives with the onboard Intel S-SATA controller via two BCA. When the BCA is connected to the controller, LEDs will illuminate on the BCA to show which port(s) are active, and the drive type supported by that port (see ‘Technical Glossary’ for diagram).
1. Ensure that the S/X cable of the BCA is connected to the mini-SAS HD connector on the
motherboard. For the lower BCA (bays 1 and 2), the S/X cable of the BCA attaches to the SATA 1-2 port on the motherboard. For the upper BCA (bays 3 and 4), the S/X cable of the BCA attaches to the SATA 3-4 port on the motherboard.
2. With AC power connected and the system off, the BCA will illuminate to show which ports are
active and the drive types supported by each port.
3. Install the SATA drive into the FLEX Tray in a manner such that the drive connectors for power
and data align correctly with the port on the BCA. Note that the FLEX Tray can be rotated 180 degrees to allow for the correct connection.
4. Align the FLEX Tray with the SATA drive and insert it into the bay making sure that the drive is
connecting to an active port. Insert the FLEX Tray fully, and push the pull-bar feature so that it is flush with the bay.
***Active ports are indicated by LED Lights shown above in yellow.
P500/P510/P700/P710 via Manual HDD Connect Option
For P500/P510 and P700/P710, SATA drives are connected to the onboard Intel S-SATA controller via a manual plug method. This consists of manually cabling both power and data to each drive individually. Total drive support is the same as P900/P910, with the onboard Intel S-SATA controller supporting up to 4 drives.
1. Install the SATA drive into the FLEX Tray. Note that FLEX Trays can be rotated 180 degrees as
needed for ease of connection.
2. Insert the FLEX Tray with drive into the bay.
3. Connect SATA power to the drive using one of the SATA power connectors on the included
cable. The other end of the SATA power cable should already be connected to the motherboard.
4. Connect the SATA data cable to the drive.
5. Connect the SATA data cable to one of the onboard SATA ports (refer to the system label on the
system cover for the SATA port location).
***One data cable per HDD/SSD. One power cable connects to four HDD/SSD.