Leica TL RCI, TL RC User Manual

Transmitted
Light Bases
TL RC
(MDG 32)
TL RCI
(MDG 30)
User Manual
Page
Overviews
Safety concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Safety regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operation
Relief contrast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Path-folding mirror . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
IsoPro™ cross stage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Light intensity and color temperature . . . . . . . . . . . . . . . . . . . . . .12
USB mouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Methods with transmitted light . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Relief display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Lamp replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Care, maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Expansion diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Dimensioned drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
2
Transmitted-light bases TL RC™ and TL RCI™ – Safety concept
Dear User
Thank you very much for your trust in Leica Microsystems. We hope your work with our high-quality, efficient products is both enjoyable and successful.
In developing our instruments, we have placed great weight on simple, self-explanatory operation. However, take your time to read the user manual, in order to familiarize yourself with the optimal use of all the benefits and options of your stereo micro­scope. Should you have any questions, please consult your local Leica representative. You will find the address of the clos­est local representative as well as valuable information about products and services from Leica Microsystems on our home­page at www
.leica-microsystems.com We are gladly at your service. CUSTOMER SERVICE is a big thing with us. Not only before the sale, but afterwards as well.
Leica Microsystems (Switzerland) Ltd. Stereo & Macroscope Systems www
.stereomicroscopy.com
The user manual
This user manual is available in 20 additional languages on our interactive CD-ROM. User manuals and updates are also available for download on our homepage at www
.stereomicroscopy.com.
The user manual at hand describes the safety instructions, assembly, and handling of the TL RC™ and TL RCI™ transmit­ted-light bases.
3
3
Transmitted-light bases TL RC™ and TL RCI™ – Safety concept
4
1.1 The user manual
The TL RC™ /TL RCI™ transmitted-light bases come with an interactive CD-ROM containing all relevant manuals in 20 additional languages. Keep this CD-ROM in a safe place, where it is available to the user. User manuals and updates are also available for download and print-out on our homepage at www.stereomicroscopy.com.
The TL RC™ and TL RCI™ transmitted-light bases are a module of the Leica M stereo microscope series. This user manual describes the special functions of the transmitted-light base and con­tains important instructions for operating safety, maintenance and the accessory parts.
The M2-105-0 user manual for the Leica M stereo microscopes contains additional safety rules for the stereo microscope, accessories and electrical accessories, as well as instructions for mainte­nance. You can combine the transmitted-light base TL RC™ with any cold light source and a glass fiber light guide (active f = 10mm, tail tube f = 13mm). Please read the user manual and the safety requirements of the supplier.
Before assembly, start up and use, please read the user manuals cited above. In particular, please observe all safety instructions.
To maintain the unit in its original condition and to ensure safe operation, the user must follow the instructions and warnings contained in these user manuals.
Transmitted-light bases TL RC™ and TL RCI™ – Safety concept
Safety concept
5
1.1.1 Symbols used
Warning of danger
This symbol indicates information, which must be read and obeyed. Disregarding these instructions – can cause hazards to personnel! – can lead to functional disturbances and
damaged instruments.
Warning of dangerous electrical voltage
This symbol indicates especially important information, which must be read and obeyed Disregarding these instructions can lead to – can cause hazards to personnel! – can lead to functional disturbances and
damaged instruments.
Warning - hot surface
This symbol warns you of tangible, hot points, such as light bulbs.
Important information
This symbol indicates additional information or explanations that intend to provide clarity.
Action
This symbol within the text indicates that
certain operations must be carried out.
Explanatory notes
• This symbol indicates additional notes and
explanations provided in the text.
Figures
(1.5) Numbers in brackets within the descriptions relate to the figures and the items within those figures. Example (1.3): Figure 1 is located, for example, on Page 8 and item 3 is the filter carrier.
Transmitted-light bases TL RC™ and TL RCI™ – Safety concept
6
1.2 Safety regulations
Description
The transmitted-light bases TL RC™ and TL RCI™ fulfill the highest requirements for observation and documentation of Leica stereo microscopes of the M series. It contains a path-folding mirror, a device for partial pupil illumination and relief contrast generation, a ground-glass screen, an additional condenser and Fresnel lenses. The complete stand consists of: – Transmitted-light base TL RC™ or TL RCI™ – Stand 300 mm or 500 mm long with focusing
drive, manual coarse/fine or motorized focus – Glass stage plate, clear, 220×170×4mm – Light source and light guide according to
requirements
Accessories: – Gliding stage – Leica MATS Thermocontrol System with
heating stage – Polarization set
and many more (see Expansion diagram)
Intended uses
TL RC™ and TL RCI™ transmitted-light bases are used in the assembly of Leica M series stereo microscopes via tripod column and microscope carrier. They can be combined with any cold light source and light guide and allows you to observe transparent specimen with relief contrast and direct transmitted light. The TL RCI™ transmitted­light base posseses an integrated halogen lamp that particularly supports control by Leica Appli­cation Suite (LAS) software.
Prohibited uses
If you use the transmitted-light base TL RC™/TL RCI™, its components, and the acces­sories in a way other than that described in the user manual, harm may be caused to people or objects.
Never: – Change, rebuild or take apart parts, if not
specifically instructed to in this manual.
– Let non-authorized persons open parts of the
instrument.
– Use the transmitted-light base TL RC™/TL RCI™
for investigations and operations on the human eye.
The units or accessory components described in the user manual have been checked for safety and possible dangers. Always consult the respon­sible Leica office or the main plant in Wetzlar at any time there is a need to adjust the unit or it is combined with non Leica components which go beyond the scope of this manual. Unauthorized adjustment of the unit or improper use renders the warranty null and void.
Place of use
– Only use the transmitted-light base
TL RC™/ TL RCI™ in closed, dust free rooms and between +10°C and +40°C. Make sure that the rooms are free of oil vapors or other chemi­cal vapors and extreme humidity.
– Set up the electrical components at least 10 cm
from walls and combustible objects.
– Avoid large temperature fluctuations, direct
sunlight and vibrations. This can cause faulty measurements or microphotographs.
– In warm, or warm and humid climatic zones,
the transmitted-light base TL RC™/ TL RCI™ requires particular care to prevent formation of fungus.
Transmitted-light bases TL RC™ and TL RCI™ – Safety concept
7
Responsibilities of person in charge of the instrument
Ensure that – The transmitted-light base TL RC™/ TL RCI™
and the accessories are only operated, main-
tained and repaired by authorized and trained
personnel. – Personnel who use the instrument have read
and understood this user manual and in partic-
ular the safety instructions and obey them.
Repairs, servicing work
– Repairs may only be carried out by servicing
engineers trained by Leica Microsystems or
your own authorized technical personnel. – Only original Leica Microsystems parts may
be used. – Before opening the devices, turn off power
and unplug mains cables.
If you touch the electric circuit of the
equipment, you may receive an electric shock.
Transport
– Use the original packaging for shipping or
transporting the transmitted-light base TL RC™/
TL RCI™ and the accessory components. – To prevent damage through vibrations, remove
and pack specially all the moving components
which you installed yourself, in accordance
with the user manual.
Integration in third-party products
The following must be observed if Leica products are built into third-party products: The manufac­turer of the complete system or the person putting it on the market is responsible for adhering to applicable safety regulations, laws and guide­lines.
Disposal
The products described here must be disposed off in accordance with applicable local laws and reg­ulations.
Legal requirements
Adhere to general and local regulations relating to accident prevention and environmental pro­tection.
EU declaration of conformity
The transmitted-light base TL RC™/ TL RCI™ and the accessories have been constructed according to the state of the art and issued with an EU dec­laration of conformity.
Transmitted-light bases TL RC™ and TL RCI™ – Safety concept
8
Controls
Fig. 1
1 Cooling element of integrated halogen illumination (TL RCI™ only) 2 Adapter plate for easy assembly of focusing drives 3 Standard stage 10 447 269 4 Filter bracket for up to three filters 5 Control button for the upper and lower Rottermann-Contrasts™ flap 6 Button to rotate and side-to-side movement of mirror 7 TL RCI™ transmitted-light base
1 2 3 4
5 6 7
Transmitted-light bases TLRC™ and TL RCI™
Loading...