Leica Lino L2P5/L2P5G
1

Overview

The Leica Lino L2P5/L2P5G is a self-levelling mul­tifunctional laser. It combines the advantage of a cross-line laser and a point laser in one tool. It isa reliable precision laser for any kind of taskslike lev­elling, plumbing, transfering and setting out right angles. It supports you on job side with two crossing ver­ticaland horizontal lines and five points (four points and one intersection point in front of the device) which are arranged precisely in 90° to each other.
1Window of vertical line and plumb up point
2Window of horizontalline and hori­zontal transfer points
3Window of plumbing
4Status LED (on keypad)
5Laser key(on keypad), ON/OFF
6Keypad
7Levelling lock
8Battery pack
9Tripod thread 1/4"
There are 2 different types available:
l L2P5 (r ed laser)
l L2P5G (green laser)
On allimages in this document only the red laser version is shown.
Leica Lino L2P5/L2P5G
2

Technical data

Tech nicalda ta
Description L2P5 L2P5G Beam direction/fan angle Vertical / >170°, Horizontal / >180° Point direction Up, down, right, left, front (90°/180°) Range* 25 m (82 ft) 35 m (115 ft) Range* with receiver 80 m (262 ft) Levelling accuracy ±0.2 mm/m = ±2.0 mm @ 10m (±0.002 in/ft = ±0.08 in @ 33ft) Horizontal/Verticalline accuracy ±0.3 mm/m (±0.004 in/ft) Point accuracy ±0.2 mm/m (±0.002 in/ft) Self-levelling range ± 4 ° Self-levelling time < 3 s Out-of-level warning Yes - blink lines every 5 s Levelling system Automatic pendulum lockable
Laser type 635 ± 5 nm, Class 2 (acc. IEC 60825-1) 525 ± 5 nm, Class 2 (acc. IEC 60825-1) Protection class IP 54 (IEC 60529) dust and splash water Drop resistant 6 x 0.5 m (1.64 ft) Battery type Lino Li-Ion battery pack 5200 mAh / 18.7 Wh (3 alkaline AA)
Operating time with Li-Ion battery 26h (2 beam + 4 point) -
44h (1 beam + 2 point) continuous
Operating time with alkaline batteries 8h (2 beam + 4 point) -
13h (1 beam + 2 point) continuous
Automatic shut-off Available
Dimensions(L x W x H) 110 x 60 x 100 mm (4.33 x 2.36 x 3.93 in)
Weight with Li-Ion battery 530 g (1.17 lbs)
Operating temperature -10…+50 °C (+14…+122 °F)
Storage temper ature -25…+70 °C (-13…+158 °F)
Laser line width at 5m distance < 2 mm (<0.08 in)
Tripod thread 1/4’’ (+ 5/8’’with adapter)
Pulsepower for receiver Yes, auto
15h (2 beam + 4 point) ­28h (1 beam+ 2 point) continuous
4h (2 beam + 4 point) ­7h (1 beam+ 2 point) continuous
* depending on lighting conditions
Leica Lino L2P5/L2P5G
3

Instrument Set-up

InstrumentSet-up
Introduction
The safety instructions (see Safety Instruc-
tions) and the user manual shouldbe read
through carefullybefore the product is used for the first time.
The person responsible for the product must ensure that all users understand these dir­ectionsand adhere to them.
The symbols used have the following meanings:
WARNING
Indicatesa potentiallyhazardous situation or an unintended use which, if not avoided, willresult in death or serious injury.
CAUTION
Indicatesa potentiallyhazardous situation or an unintended use which, if not avoided, may result in minor injury and/or appreciable material, financial and environmental damage.

Levelling lock

Level ling unlock ed
In the unlockedposition the instrument auto­matically levelsitselfwithin the specified inclin­ation range. (See Technicaldata)
Level ling lock ed
Turn the levelling lock in order to transport or tilt the instrument beyond the self-levelling range. When locked, the pendulum is fixed and the self­levelling function isdeactivated. In this case the laser blinks every 5sec.
Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner.
Leica Lino L2P5/L2P5G
4
Instrument Set-up
Laser receiver
To be able to detect the laser lines over long dis­tances or inunfavourable lighting conditions, a laser receiver can be used.
We recommend the Leica RGR200 laser receiver.
The Lino is powered by XRANGE technologyand therefore automaticallydetected by the receiver.
Li-Ion battery
Charge Li-Ion battery
Charge the Li-Ion battery before using it for the first time. While charging, the instrument may heat up. This isnormal and should not affect the instru­ment´s lifespan or performance. At the recom­mended storage temperature of -20°C to +30°C (-4°F to +86°F), batteries containing a 50% to 100% charge can be stored up to 1 year. After this storage period the batteries must be recharged.
CAUTION
Connecting the charger using the wrong adapter may causeserious damage to the instrument. Any damage caused by misuse is not covered by war­ranty. Use only Leica-approved chargers, bat­teries and cables. Unapproved chargers or cables can causethe battery to explode or damage the instrument.
Leica Lino L2P5/L2P5G
5
Instrument Set-up
Insert Li-Ion battery
Insert the battery-pack by pressing it down and then tilting it towards the housing as shown until it snaps in.
Li-Ion status LED
lightsgreen: charging battery
OFF: charging finished / no charging
Alkaline batteries
To ensure a reliable use, we recommend using high qualityAlkaline batteries.
Insert Alkaline batteries
Insert Alkaline batteries in the battery-pack.
Insert the battery-pack
Insert the battery-pack by pressing it down and then tilting it towards the housing as shown until it snaps in.
Leica Lino L2P5/L2P5G
6

Operations

Operations
Switching ON/OFF
Auto power-off Placethe lock switch to the unlocked position (see Levelling lock). To activate auto power- off after 30 min operation pr ess and hold the On button at start for 5 sec. The status LED blinks 3 times in green colour. To deactivate it again repeat the described steps until the status LED blinks 3 times in red colour.
Leica Lino L2P5/L2P5G
7
Operations
Functions
Check if self-levelling is r equired and cor­respondingly activated. ( See Levelling lock for details)
Vertical lines and dots / horizontal lines and dots on
Horizontal line and dots on Vertical line and dots on
Leica Lino L2P5/L2P5G
8

How to use the smart adapters

Howtouse thesma rtadapters
Setup device to adapter
Alignment of vertical laser lines
Alignment of horizontal laser lines
Snap the device on the Twist 360 adapter.
Leica Lino L2P5/L2P5G
Turn the device 360° around the plumb point to adjust the vertical line.
Turn the adjustment knob of UAL130 to fine adjust the horizonal line to the desired reference level.
9
How to use the smart adapters
Different fixing applications
Leica Lino L2P5/L2P5G
10

Message Codes

Messa geCo des
Laser LED Cause Correction
ON/OFF lightsred Instrument has low power Charge Li-Ion battery or change
OFF blinksred Temperature alert Cool down or heat up instrument
blinks blinksred Instrument is out of self-levelling
range
blinks lights red Instrument isout of self-levelling
range and has low power
blinks every 5 sec lightsred Levelling lock isactivated but
instrument has low power
blinks every 5 sec blinks gr een Levelling lock isactivated for work-
ing without self-levelling
Alkaline batteries
Placethe instrument almost hori­zontal and self-levelling willstart automatically
Charge Li-Ion battery or change Alkaline batteries
Charge Li-Ion battery or change Alkaline batteries
Leica Lino L2P5/L2P5G
11

Accuracy Check

Accu racyCh eck
Check the accuracy of your Leica Lino reg­ularly and particularlybefore important meas­uring tasks.Check Levelling lockbefore checking the accuracy.

Levelling

Checki ng the accurac y of the levelling
Set the instrument on a tripod half-way between two walls (A+B) that are approx. 5 m apart. Place the lockswitch in the "Unlocked" position (see Lev-
elling lock). Direct the instrument at wall A and
switch on the instrument. Activate the horizontal laser line or laser point and mark the position of the line or the point on wall (A1). Rotate the instru­ment by 180° and mark the horizontal laser line or the laser point in exactlythe same way on wall (B1).
Then place the instrument at the same elevation as close as possible to wall A and again mark the horizontal laser line or the laser point on wall A (A2). Rotate the instrument by 180° again and mark the laser on wall B (B2). Measure the dis­tances of the mar ked points A1-A2 and B1-B2. Calculate the difference of the two meas­urements.
|(A1 - A2) - (B1 - B2)| <=2 mm
If the difference does not exceed 2 mm, then the Leica Lino is within tolerance.
Should your Leica Lino be outside of the spe­cified tolerance, please contact a localdealer or an authorised Leica Geosystems dis­tributor.
Leica Lino L2P5/L2P5G
12
Accuracy Check
Vertical and horizontal line
Checki ng the accurac y of the horizontal line
Placethe lock switch in the "Unlocked" position (see Levelling lock). Position the instrument approx. 5 m away from the wall. Direct the instru­ment at the wall and switchon. Activate the laser lineand mark the intersection point of laser crosshairs on the wall. Swivelthe instrument to the right and then to the left. Observe the verticaldevi­ation of the horizontal line from the marking. If the difference does not exceed 3 mm, then the Leica Lino is within tolerance.
Checki ng the accurac y of the vertic al line
Placethe lock switch in the "Unlocked" position (see Levelling lock). As a reference, use a plumb- bob and attach it as closeas possible to an approx. 3 m high wall. Position the instrument at a distance of approx. 1.5 m from the wall at an elevation of approx. 1.5 m. Direct the instrument at the wall and switch on. Rotate the instrument and align it with the bottom of the plumb line. Now read off the maximum deviation of the laser line from the top of the plumb line. If the difference does not exceed 2 mm, then the Leica Lino is within tolerance.
Should your Leica Lino be outside of the spe­cified tolerance, please contact a localdealer or an authorised Leica Geosystems dis­tributor.
Vertical plumb points
Checki ng the accurac y of the upper plumb point:
Placethe lock switch in the "Unlocked" position (see Levelling lock). Set up the laser on itstripod to wall mount bracket near point A1 at a minimum dis­tance of 1.5 m from point B1. The horizontal laser isaligned in direction 1. Mark the laser points A1 and B1 with a pin.
Checki ng the accurac y of the lower pl umb point:
Leica Lino L2P5/L2P5G
13
Accuracy Check
Rotate the instrument by 180° so that it points in the opposite direction 2 to direction 1. Adjust the instrument so that the laser beam hitspoint A1 exactly. If point B2 is no fur ther than 2 mm away from point B1, then the Leica Lino is within tol­erance.
Should your Leica Lino be outside of the spe­cified tolerance, please contact a localdealer or an authorised Leica Geosystems dis­tributor.
Perpendicularity horizontal points
Placelock switch in "Unlocked" position (see Lev-
elling lock). Mark a reference point (P1) approx.
5m from the wallsand position the lower plumb point exactly on it. Alignthe cross hair to the left wall and mar k the intersectionpoint (a1) approx. on the same hight like P1 to the wall. Shortly after mark the right-hand perpendicular beam (b1) on the front wall.
Then rotate the device exactly90° clockwise around the plumb point P1 and position the left-
hand perpendicular beam to the existing ref­erence point a1. Make sure that the upper plumb point isstill exactly on the reference P1. Check afterwards the new reference point b2 with the old reference b1 on the front wall. The deviation between the two points may be max. 3mm. Mark the new position of the right-hand perpendicular beam to the right wall with c1.
Should your Leica Lino be outside of the spe­cified tolerance, please contact a localdealer or an authorised Leica Geosystems dis­tributor.
Afterwar ds turn the device exactly 180° around the plumb point P1 and position the right-hand per­pendicular beam to the existing reference point a1. Make sure that the upper plumb point isstill exactly on the reference P1. Then mark the left­hand beam to the right wall and mark it with c2. Fin­allymeasure the difference between the former reference point c1 and the new point c2. The devi­ation may be max. 3mm between these two points.
Leica Lino L2P5/L2P5G
14
Accuracy Check
Should your Leica Lino be outside of the spe­cified tolerance, please contact a localdealer or an authorised Leica Geosystems dis­tributor.
Leica Lino L2P5/L2P5G
15

Care

Care
Never immerse the device in water. Wipe off dirt with a damp soft cloth. Never use aggressive cleaning agents or solvents.Treat the instrument with the same care that you would applyto bin­oculars or a camera. Dropping or violent shaking of the instrument may damage it. Check the instru­ment for any damage before using it. Check the
levelling accuracy of the instrument regularly.
To warranty the best precision and visibility please clean the optics of your device regularly. There­fore blow off the dust from the glasses without touching the opticswith your fingers. If necessary use a damp soft cloth and a little bit of pure alcohol.
To avoid wrong measurements also clean your adapters regularly. This could be done also by the proposed recommendation. Especially the inter­face between the adapter and device should always be clean to enable easy rotation. To clean the magnetic surface you could use compressed air or modelling clay.
If the equipment get wet always dry it (max. 70°C/158°F) before repacking it into the case.
Leica Lino L2P5/L2P5G
16

Warranty

Warranty
International Limited Warranty
The Leica Lino comes with a two year warranty from Leica Geosystems AG. To receive an addi­tional year warranty, the product must be registered on our website at http://myworld.leica-
geosystems.com within eight week s of the pur-
chase date. If the pr oduct is not registered, our two year warranty applies.
More detailed information about the International Limited Warranty can be found on the internet at:
www.leica-geo­systems.com/internationalwarranty.
Calibration and repair service
Leica Geosystemsrecommend to checkthe device within regular intervals to prove the func­tion and reliability in accordance with standards and requirements. At least one time per year.
In case of damaging your product please never attemp to repair the device yourself.
For calibration or repair service please visit your localdealer or any certified Leica Geosystemsdis­tributor.
Leica Lino L2P5/L2P5G
17

Safety instructions

Safetyinstructions
The person responsible for the instrument must ensure that allusers understand these directionsand adhere to them.
Areas of responsibility
Responsibi lities of the manufacturer of the ori­ginal equipment:
Leica GeosystemsAG Heinrich-Wild-Strasse CH-9435 Heerbrugg Internet: www.leica-geosystems.com
The company above isresponsible for supplying the product, including the User Manual in a com­pletelysafe condition.
The company above isnot responsible for third party accessories.
Responsibi lities of the person in charge of the ins trument:
1. To understand the safety instructions on the product and the instructions in the User Manual.
2. To be familiar with local safety regulations relating to accident prevention.
3. Alwaysprevent access to the product by unauthorised personnel.
Permitted use
1. Projection of horizontaland vertical laser linesand laser points
Leica Lino L2P5/L2P5G
18
Safety instructions
Prohibited use
1. Using the pr oduct without instruction
2. Using outside the stated limits
3. Deactivation of safety systems and removal of explanatory and hazard labels
4. Opening of the equipment by using tools (screwdrivers, etc.)
5. Carrying out modification or conversion of the product
6. Deliberate dazzling of third parties; also in the dark
7. Inadequate safeguards at the surveying site (e.g. when measuring on roads, con­struction sites, etc.)
Hazards in use
WARNING
Watch out for erroneous measurements if the instrument isdefective or ifit has been dropped or has been misused or modified. Carry out periodic test measurements. Particularlyafter the instru­ment has been subject to abnormal use, and before, during and after important meas­urements.
CAUTION
Never attempt to repair the product yourself. In case of damage, contact a local dealer.
WARNING
Changes or modificationsnot expressively approved by Leica Geosystems/manufacturer for compliance could void the user´s authority to oper­ate the equipment.
WARNING
Laser/adapters should not be used in the vicinity of pacemaker because of integrated magnets which can affect the function of the pacemaker.
Limits of use
Refer to section Technicaldata. The instru­ment is designed for use in ar eas per­manently habitable for humans. Do not use the product in explosion hazardous areas or in aggressiveenvironments.
Leica Lino L2P5/L2P5G
19
Safety instructions
Disposal
CAUTION
Flat batteries must not be disposed of with house­hold waste. Care for the environment and take them to the collection points provided in accord­ance with national or local regulations.
The product must not be disposed with household waste. Dispose of the product appropriately in accordance with the national regulations in force in your country. Adhere to the national and country specificreg­ulations.
Product specific treatment and waste man­agement can be downloaded from our homepage.
Transport
Transport of instrument
Alwaysset the device in "Locked" position by turn­ing the lockswitch when transporting the device (see Levelling lock). Please use the original case or an equivalent packaging for transporting and shipping your measuring device.
Transport of Li-Ion battery
WARNING
During transport, shipping or disposal of batteries it is possible for inappropriate mechanicalinflu­ences to constitute a fire hazard.
Precautions:
Before shipping the product or disposingit, dis­charge the batteries by running the product until they are flat. When transporting or shipping bat­teries, the person in charge of the product must ensure that the applicable national and inter­national rules are observed. Before transportation or shipping, contact your localpassenger or freight transport company.
WARNING
High mechanicalstress, high ambient tem­peratures or immersion into fluids can cause leak­age, fire or explosionof the batteries.
Precautions:
Protect the batteries from mechanical influences and high ambient temperatur es. Do not drop or immerse batteries into fluids.
For further information about charging please refer to Li-Ion battery.
Leica Lino L2P5/L2P5G
20
Safety instructions
Electromagnetic Compatibility
(EMC)
WARNING
The device conforms to the most stringent require­ments of the relevant standards and regulations. However, the possibility of causing interference in other devices cannot be totallyexcluded.
FCC statement (applicable in U.S.)
This equipment has been tested and found to com­ply with the limits for a Class B digitalinstrument, pursuant to part 15 of the FCC r ules. These limits are designed to provide reasonable protection against harmful interference in a residentialinstall­ation. This equipment gener ates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio com­munications.
However, there is no guarantee that interference willnot occur in a particular installation. If this equip­ment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient or r elocate the receiving antenna
2. Increase the separation between the equipment and the receiver
3. Connect the equipment into an outlet on a circuit different from that to which the receiver isconnected
4. Consult the dealer or an experienced radi­o/TV technician for help
This instrument complies with part 15 of the FCC rules. Operation issubjected to the following two conditions:
1. This instrument may not causeharmful interference, and
2. this instrument must accept any inter­ference received, including interference that may cause undesired operation.
ISED statement (appl icable in Canada)
This instrument complies with Industry Canada license-exempt RSS standard(s). Operation is subjected to the following two conditions:
1. This instrument may not causeharmful interference, and
2. this instrument must accept any inter­ference received, including interference that may cause undesired operation.
Leica Lino L2P5/L2P5G
21
Safety instructions
Laser classification
The instrument produces visible laser beams, which are emitted from the instrument. It is a Class 2 laser product in accordance with:
l IEC60825-1 : 2014 „Radiation safety of
laser products“
Laser Class 2 products
Do not stare into the laser beam or direct it towards other people unnecessarily. Eye pro­tection is normallyafforded by aversion responses including the blinkreflex.
WARNING
Looking directly into the beam with opticalaids (e.g. binoculars, telescopes) can be hazardous.
CAUTION
Looking into the laser beam may be hazardous to the eyes.
Wavelength
L2P5: 635 +/- 5 nm (red) / L2P5G: 525 +/- 5 nm (green)
Maximum radiant output power for classification
<1 mW
Pulseduration
70 µs, cw (red) / 50 - 70 µs (green)
Pulserepetition frequency
< 200°
Beam divergence point
< 1.5 mrad
Leica Lino L2P5/L2P5G
10 kHz
Beam divergence line
22
Safety instructions
Labelling
Subject to change (drawings, descriptionsand technicaldata) without prior notice.