The Leica Lino L2P5/L2P5G is a self-levelling multifunctional laser. It combines the advantage of a
cross-line laser and a point laser in one tool. It isa
reliable precision laser for any kind of taskslike levelling, plumbing, transfering and setting out right
angles.
It supports you on job side with two crossing verticaland horizontal lines and five points (four
points and one intersection point in front of the
device) which are arranged precisely in 90° to
each other.
1Window of vertical line and plumb up
point
2Window of horizontalline and horizontal transfer points
3Window of plumbing
4Status LED (on keypad)
5Laser key(on keypad), ON/OFF
6Keypad
7Levelling lock
8Battery pack
9Tripod thread 1/4"
There are 2 different types available:
l L2P5 (r ed laser)
l L2P5G (green laser)
On allimages in this document only the red
laser version is shown.
Leica Lino L2P5/L2P5G
2
Technical data
Tech nicalda ta
DescriptionL2P5L2P5G
Beam direction/fan angleVertical / >170°, Horizontal / >180°
Point directionUp, down, right, left, front (90°/180°)
Range*25 m (82 ft)35 m (115 ft)
Range* with receiver80 m (262 ft)
Levelling accuracy±0.2 mm/m = ±2.0 mm @ 10m (±0.002 in/ft = ±0.08 in @ 33ft)
Horizontal/Verticalline accuracy±0.3 mm/m (±0.004 in/ft)
Point accuracy±0.2 mm/m (±0.002 in/ft)
Self-levelling range± 4 °
Self-levelling time< 3 s
Out-of-level warningYes - blink lines every 5 s
Levelling systemAutomatic pendulum lockable
Laser type635 ± 5 nm, Class 2 (acc. IEC 60825-1)525 ± 5 nm, Class 2 (acc. IEC 60825-1)
Protection classIP 54 (IEC 60529) dust and splash water
Drop resistant6 x 0.5 m (1.64 ft)
Battery typeLino Li-Ion battery pack 5200 mAh / 18.7 Wh (3 alkaline AA)
Operating time with Li-Ion battery26h (2 beam + 4 point) -
44h (1 beam + 2 point) continuous
Operating time with alkaline batteries8h (2 beam + 4 point) -
13h (1 beam + 2 point) continuous
Automatic shut-offAvailable
Dimensions(L x W x H)110 x 60 x 100 mm (4.33 x 2.36 x 3.93 in)
through carefullybefore the product is used
for the first time.
The person responsible for the product must
ensure that all users understand these directionsand adhere to them.
The symbols used have the following meanings:
WARNING
Indicatesa potentiallyhazardous situation or an
unintended use which, if not avoided, willresult in
death or serious injury.
CAUTION
Indicatesa potentiallyhazardous situation or an
unintended use which, if not avoided, may result in
minor injury and/or appreciable material, financial
and environmental damage.
Levelling lock
Level ling unlock ed
In the unlockedposition the instrument automatically levelsitselfwithin the specified inclination range. (See Technicaldata)
Level ling lock ed
Turn the levelling lock in order to transport or tilt
the instrument beyond the self-levelling range.
When locked, the pendulum is fixed and the selflevelling function isdeactivated. In this case the
laser blinks every 5sec.
Important paragraphs which must be
adhered to in practice as they enable the
product to be used in a technically correct
and efficient manner.
Leica Lino L2P5/L2P5G
4
Instrument Set-up
Laser receiver
To be able to detect the laser lines over long distances or inunfavourable lighting conditions, a
laser receiver can be used.
We recommend the Leica RGR200 laser
receiver.
The Lino is powered by XRANGE technologyand
therefore automaticallydetected by the receiver.
Li-Ion battery
Charge Li-Ion battery
Charge the Li-Ion battery before using it for the
first time. While charging, the instrument may heat
up. This isnormal and should not affect the instrument´s lifespan or performance. At the recommended storage temperature of -20°C to +30°C
(-4°F to +86°F), batteries containing a 50% to
100% charge can be stored up to 1 year. After this
storage period the batteries must be recharged.
CAUTION
Connecting the charger using the wrong adapter
may causeserious damage to the instrument. Any
damage caused by misuse is not covered by warranty. Use only Leica-approved chargers, batteries and cables. Unapproved chargers or cables
can causethe battery to explode or damage the
instrument.
Leica Lino L2P5/L2P5G
5
Instrument Set-up
Insert Li-Ion battery
Insert the battery-pack by pressing it down and
then tilting it towards the housing as shown until it
snaps in.
Li-Ion status LED
lightsgreen: charging battery
OFF: charging finished / no charging
Alkaline batteries
To ensure a reliable use, we recommend
using high qualityAlkaline batteries.
Insert Alkaline batteries
Insert Alkaline batteries in the battery-pack.
Insert the battery-pack
Insert the battery-pack by pressing it down and
then tilting it towards the housing as shown until it
snaps in.
Leica Lino L2P5/L2P5G
6
Operations
Operations
Switching ON/OFF
Auto power-off
Placethe lock switch to the unlocked position
(see Levelling lock). To activate auto power-
off after 30 min operation pr ess and hold the
On button at start for 5 sec. The status LED
blinks 3 times in green colour. To deactivate
it again repeat the described steps until the
status LED blinks 3 times in red colour.
Leica Lino L2P5/L2P5G
7
Operations
Functions
Check if self-levelling is r equired and correspondingly activated. ( See Levelling lock
for details)
Vertical lines and dots / horizontal lines and dots
on
Horizontal line and dots onVertical line and dots on
Leica Lino L2P5/L2P5G
8
How to use the smart adapters
Howtouse thesma rtadapters
Setup device to adapter
Alignment of vertical laser lines
Alignment of horizontal laser lines
Snap the device on the Twist 360 adapter.
Leica Lino L2P5/L2P5G
Turn the device 360° around the plumb point to
adjust the vertical line.
Turn the adjustment knob of UAL130 to fine adjust
the horizonal line to the desired reference level.
9
How to use the smart adapters
Different fixing applications
Leica Lino L2P5/L2P5G
10
Message Codes
Messa geCo des
LaserLEDCauseCorrection
ON/OFFlightsredInstrument has low powerCharge Li-Ion battery or change
OFFblinksredTemperature alertCool down or heat up instrument
blinksblinksredInstrument is out of self-levelling
range
blinkslights redInstrument isout of self-levelling
range and has low power
blinks every 5 seclightsredLevelling lock isactivated but
instrument has low power
blinks every 5 secblinks gr eenLevelling lock isactivated for work-
ing without self-levelling
Alkaline batteries
Placethe instrument almost horizontal and self-levelling willstart
automatically
Charge Li-Ion battery or change
Alkaline batteries
Charge Li-Ion battery or change
Alkaline batteries
Leica Lino L2P5/L2P5G
11
Accuracy Check
Accu racyCh eck
Check the accuracy of your Leica Lino regularly and particularlybefore important measuring tasks.Check Levelling lockbefore
checking the accuracy.
Levelling
Checki ng the accurac y of the levelling
Set the instrument on a tripod half-way between
two walls (A+B) that are approx. 5 m apart. Place
the lockswitch in the "Unlocked" position (see Lev-
elling lock). Direct the instrument at wall A and
switch on the instrument. Activate the horizontal
laser line or laser point and mark the position of
the line or the point on wall (A1). Rotate the instrument by 180° and mark the horizontal laser line or
the laser point in exactlythe same way on wall
(B1).
Then place the instrument at the same elevation
as close as possible to wall A and again mark the
horizontal laser line or the laser point on wall A
(A2). Rotate the instrument by 180° again and
mark the laser on wall B (B2). Measure the distances of the mar ked points A1-A2 and B1-B2.
Calculate the difference of the two measurements.
|(A1 - A2) - (B1 - B2)| <=2 mm
If the difference does not exceed 2 mm, then the
Leica Lino is within tolerance.
Should your Leica Lino be outside of the specified tolerance, please contact a localdealer
or an authorised Leica Geosystems distributor.
Leica Lino L2P5/L2P5G
12
Accuracy Check
Vertical and horizontal line
Checki ng the accurac y of the horizontal line
Placethe lock switch in the "Unlocked" position
(see Levelling lock). Position the instrument
approx. 5 m away from the wall. Direct the instrument at the wall and switchon. Activate the laser
lineand mark the intersection point of laser
crosshairs on the wall. Swivelthe instrument to the
right and then to the left. Observe the verticaldeviation of the horizontal line from the marking. If the
difference does not exceed 3 mm, then the Leica
Lino is within tolerance.
Checki ng the accurac y of the vertic al line
Placethe lock switch in the "Unlocked" position
(see Levelling lock). As a reference, use a plumb-
bob and attach it as closeas possible to an approx.
3 m high wall. Position the instrument at a distance
of approx. 1.5 m from the wall at an elevation of
approx. 1.5 m. Direct the instrument at the wall
and switch on. Rotate the instrument and align it
with the bottom of the plumb line. Now read off the
maximum deviation of the laser line from the top of
the plumb line. If the difference does not exceed 2
mm, then the Leica Lino is within tolerance.
Should your Leica Lino be outside of the specified tolerance, please contact a localdealer
or an authorised Leica Geosystems distributor.
Vertical plumb points
Checki ng the accurac y of the upper plumb
point:
Placethe lock switch in the "Unlocked" position
(see Levelling lock). Set up the laser on itstripod to
wall mount bracket near point A1 at a minimum distance of 1.5 m from point B1. The horizontal laser
isaligned in direction 1. Mark the laser points A1
and B1 with a pin.
Checki ng the accurac y of the lower pl umb
point:
Leica Lino L2P5/L2P5G
13
Accuracy Check
Rotate the instrument by 180° so that it points in
the opposite direction 2 to direction 1. Adjust the
instrument so that the laser beam hitspoint A1
exactly. If point B2 is no fur ther than 2 mm away
from point B1, then the Leica Lino is within tolerance.
Should your Leica Lino be outside of the specified tolerance, please contact a localdealer
or an authorised Leica Geosystems distributor.
Perpendicularity horizontal points
Placelock switch in "Unlocked" position (see Lev-
elling lock). Mark a reference point (P1) approx.
5m from the wallsand position the lower plumb
point exactly on it. Alignthe cross hair to the left
wall and mar k the intersectionpoint (a1) approx.
on the same hight like P1 to the wall. Shortly after
mark the right-hand perpendicular beam (b1) on
the front wall.
Then rotate the device exactly90° clockwise
around the plumb point P1 and position the left-
hand perpendicular beam to the existing reference point a1. Make sure that the upper plumb
point isstill exactly on the reference P1. Check
afterwards the new reference point b2 with the old
reference b1 on the front wall. The deviation
between the two points may be max. 3mm. Mark
the new position of the right-hand perpendicular
beam to the right wall with c1.
Should your Leica Lino be outside of the specified tolerance, please contact a localdealer
or an authorised Leica Geosystems distributor.
Afterwar ds turn the device exactly 180° around
the plumb point P1 and position the right-hand perpendicular beam to the existing reference point
a1. Make sure that the upper plumb point isstill
exactly on the reference P1. Then mark the lefthand beam to the right wall and mark it with c2. Finallymeasure the difference between the former
reference point c1 and the new point c2. The deviation may be max. 3mm between these two
points.
Leica Lino L2P5/L2P5G
14
Accuracy Check
Should your Leica Lino be outside of the specified tolerance, please contact a localdealer
or an authorised Leica Geosystems distributor.
Leica Lino L2P5/L2P5G
15
Care
Care
Never immerse the device in water. Wipe off dirt
with a damp soft cloth. Never use aggressive
cleaning agents or solvents.Treat the instrument
with the same care that you would applyto binoculars or a camera. Dropping or violent shaking
of the instrument may damage it. Check the instrument for any damage before using it. Check the
levelling accuracy of the instrument regularly.
To warranty the best precision and visibility please
clean the optics of your device regularly. Therefore blow off the dust from the glasses without
touching the opticswith your fingers. If necessary
use a damp soft cloth and a little bit of pure alcohol.
To avoid wrong measurements also clean your
adapters regularly. This could be done also by the
proposed recommendation. Especially the interface between the adapter and device should
always be clean to enable easy rotation. To clean
the magnetic surface you could use compressed
air or modelling clay.
If the equipment get wet always dry it (max.
70°C/158°F) before repacking it into the case.
Leica Lino L2P5/L2P5G
16
Warranty
Warranty
International Limited Warranty
The Leica Lino comes with a two year warranty
from Leica Geosystems AG. To receive an additional year warranty, the product must be
registered on our website at http://myworld.leica-
geosystems.com within eight week s of the pur-
chase date. If the pr oduct is not registered, our
two year warranty applies.
More detailed information about the International
Limited Warranty can be found on the internet at:
www.leica-geosystems.com/internationalwarranty.
Calibration and repair service
Leica Geosystemsrecommend to checkthe
device within regular intervals to prove the function and reliability in accordance with standards
and requirements. At least one time per year.
In case of damaging your product please never
attemp to repair the device yourself.
For calibration or repair service please visit your
localdealer or any certified Leica Geosystemsdistributor.
Leica Lino L2P5/L2P5G
17
Safety instructions
Safetyinstructions
The person responsible for the instrument
must ensure that allusers understand these
directionsand adhere to them.
Areas of responsibility
Responsibi lities of the manufacturer of the original equipment:
The company above isresponsible for supplying
the product, including the User Manual in a completelysafe condition.
The company above isnot responsible for third
party accessories.
Responsibi lities of the person in charge of the
ins trument:
1. To understand the safety instructions on
the product and the instructions in the
User Manual.
2. To be familiar with local safety regulations
relating to accident prevention.
3. Alwaysprevent access to the product by
unauthorised personnel.
Permitted use
1. Projection of horizontaland vertical laser
linesand laser points
Leica Lino L2P5/L2P5G
18
Safety instructions
Prohibited use
1. Using the pr oduct without instruction
2. Using outside the stated limits
3. Deactivation of safety systems and
removal of explanatory and hazard labels
4. Opening of the equipment by using tools
(screwdrivers, etc.)
5. Carrying out modification or conversion
of the product
6. Deliberate dazzling of third parties; also in
the dark
7. Inadequate safeguards at the surveying
site (e.g. when measuring on roads, construction sites, etc.)
Hazards in use
WARNING
Watch out for erroneous measurements if the
instrument isdefective or ifit has been dropped or
has been misused or modified. Carry out periodic
test measurements. Particularlyafter the instrument has been subject to abnormal use, and
before, during and after important measurements.
CAUTION
Never attempt to repair the product yourself. In
case of damage, contact a local dealer.
WARNING
Changes or modificationsnot expressively
approved by Leica Geosystems/manufacturer for
compliance could void the user´s authority to operate the equipment.
WARNING
Laser/adapters should not be used in the vicinity of
pacemaker because of integrated magnets which
can affect the function of the pacemaker.
Limits of use
Refer to section Technicaldata. The instrument is designed for use in ar eas permanently habitable for humans. Do not use
the product in explosion hazardous areas or
in aggressiveenvironments.
Leica Lino L2P5/L2P5G
19
Safety instructions
Disposal
CAUTION
Flat batteries must not be disposed of with household waste. Care for the environment and take
them to the collection points provided in accordance with national or local regulations.
The product must not be disposed with
household waste. Dispose of the product
appropriately in accordance with the national
regulations in force in your country. Adhere
to the national and country specificregulations.
Product specific treatment and waste management can be downloaded from our
homepage.
Transport
Transport of instrument
Alwaysset the device in "Locked" position by turning the lockswitch when transporting the device
(see Levelling lock). Please use the original case
or an equivalent packaging for transporting and
shipping your measuring device.
Transport of Li-Ion battery
WARNING
During transport, shipping or disposal of batteries
it is possible for inappropriate mechanicalinfluences to constitute a fire hazard.
Precautions:
Before shipping the product or disposingit, discharge the batteries by running the product until
they are flat. When transporting or shipping batteries, the person in charge of the product must
ensure that the applicable national and international rules are observed. Before transportation
or shipping, contact your localpassenger or
freight transport company.
WARNING
High mechanicalstress, high ambient temperatures or immersion into fluids can cause leakage, fire or explosionof the batteries.
Precautions:
Protect the batteries from mechanical influences
and high ambient temperatur es. Do not drop or
immerse batteries into fluids.
For further information about charging
please refer to Li-Ion battery.
Leica Lino L2P5/L2P5G
20
Safety instructions
Electromagnetic Compatibility
(EMC)
WARNING
The device conforms to the most stringent requirements of the relevant standards and regulations.
However, the possibility of causing interference in
other devices cannot be totallyexcluded.
FCC statement (applicable in U.S.)
This equipment has been tested and found to comply with the limits for a Class B digitalinstrument,
pursuant to part 15 of the FCC r ules. These limits
are designed to provide reasonable protection
against harmful interference in a residentialinstallation. This equipment gener ates, uses and can
radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may
cause harmful interference to radio communications.
However, there is no guarantee that interference
willnot occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by
turning the equipment off and on, the user is
encouraged to try to correct the interference by
one or more of the following measures:
1. Reorient or r elocate the receiving
antenna
2. Increase the separation between the
equipment and the receiver
3. Connect the equipment into an outlet on
a circuit different from that to which the
receiver isconnected
4. Consult the dealer or an experienced radio/TV technician for help
This instrument complies with part 15 of the FCC
rules. Operation issubjected to the following two
conditions:
1. This instrument may not causeharmful
interference, and
2. this instrument must accept any interference received, including interference
that may cause undesired operation.
ISED statement (appl icable in Canada)
This instrument complies with Industry Canada
license-exempt RSS standard(s). Operation is
subjected to the following two conditions:
1. This instrument may not causeharmful
interference, and
2. this instrument must accept any interference received, including interference
that may cause undesired operation.
Leica Lino L2P5/L2P5G
21
Safety instructions
Laser classification
The instrument produces visible laser beams,
which are emitted from the instrument. It is a Class
2 laser product in accordance with:
l IEC60825-1 : 2014 „Radiation safety of
laser products“
Laser Class 2 products
Do not stare into the laser beam or direct it
towards other people unnecessarily. Eye protection is normallyafforded by aversion responses
including the blinkreflex.
WARNING
Looking directly into the beam with opticalaids
(e.g. binoculars, telescopes) can be hazardous.
CAUTION
Looking into the laser beam may be hazardous to
the eyes.