Legrand NV-D2120 User Manual

NV-D2120 Digital Power Amplifier
Installation Guide
ENGLISH
FRENCH
Danger L‘exposition a des niveaux eleves de bruit peut provoquer une perte permanente de l’audition, Chaque organisme humain reagit differemment quant a la perte de l’audition, mais quasiment tout le monde subit une diminution de I’acuite auditive lors d’une exposition suffisamment longue au bruit intense. Les autorites competentes en reglementation de bruit ont defini les expositions tolerees aux niveaux de bruits:
DURE EN HEURES PAR JOUR 8 6 4 3 2 1
INIVEAU SONORE CONTINU EN dB 90 93 95 97 100 103
Selon les autorites, toute exposition dans les limites citees ci-dessus, peuvent provoquer certaines pertes d’audition. Des bouchons ou protections dans l’appareil auditif ou sur l’oreille doivent etre portes lors de l’utilisation de ce systeme d’amplification afin de prevenir le risque de perte permanente de l’audition, Dans le cas d’expositions superieures aux limites precitees il est recommande, afin de se premunir contre les expositions aux pressions acoustiquese I evees potentielIement dangeure u ses, aux personnes exposees aux equipements capables de delivrer de telles puissances, tels ce systeme d’amplification en fonctionnement, de proteger l’appareil auditif.
ATTENTION
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR.
ATTENTION: AFIN DE LlMlTER LE RISQUE DE CHO ELECTR/QUE, NE
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE DE VOLTAGE DANGEREUX NON-ISOLE A L'INTERIEUR DE CE PRODUIT QUI PEUT ETRE DE PUISSANCE SUFFISAMMENT IMPORTANTE POUR PROVOQUER UN CHOC ELECTRIQUE AUX PERSONNES.
CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE D'INSTRUCTIONS D'UTILISATION ET DE MAINTENANCE DANS LES DOCUMENTS FOURNIS AVEC CE PRODUIT.
AFIN DE REDUIRE LES RISQUÉ D'INCENDIE ET DE DECHARGE ELECTRIQUE, NE PAS EXPOSER CET APPAREIL A LA PLUIE OU A L'HUMIDITE.
PAS ENLEVER LE CHASSIS. NE CONTIENT PAS DE PIECES POUVANT ETRE REPAREE PAR L’UTILISATEUR. CONFER LE SERVICE APRES-VENTE AUX REPARATEURS
IMPORTANTES INSTRUCTIONS DE SECURITE
1. Lire avec attention toutes les recommandations et précautions d'emploi avant d'utiliser ce produit.
2. Toutes les recommandations et précautions d'emploi doivent être conservées afin de pouvoir s'y reporter si nécessaire.
3. Lire et comprendre tous les aver tissements énumérés dans les précautions d'emploi.
4. Suivre toutes les précautions d'emploi pour utiliser ce produit.
5. Ce produit ne doit pas être utilisé près d'eau, comme par exemple baignoires, éviers, piscine, sous-sol humides ... Etc.
6. Utiliser exc lusivement un chiffon sec pour nettoyer ce produit.
7. Ne bloquér aucune ouverture de ventilation. Ne pas placer le produit tout contre un mur ou dans une enceinte fernée, cela gênerait le flux d'air nécessaire au refroidissement.
8. Ne pas placer le produit près de toute source de chaeur telle que radiateurs, arrivées d'air chaud, fourneaux ou autres appareils générant de la chaleur (incluant les amplificateurs produc teurs de chaleur) .
9. Ne pas négliger la sécurité que procure un branchement polarisé ou avec raccordement à la terre, Un branchement polarisé compre nd deux fiches dont l'une est plus large que l'autre. Un branchement à la terre comprend deux fiches plus une troisième re liée à la terre. Si la fiche secteur fournie ne s'inser t pas dans votre prise de courant. consulter un 'électricien afin de remplacer votre prise obsolète.
10. Protéger le cordon d'alimentation de tout écrasement ou pincement, par ticulièrement au niveau des fiches, des réceptacles utilisés et à l'endro it de sor tie de l'appareil. Ne pas casser la fiche de terre du cordon d'alimentation.
11. Utiliser uniquement les accessoires spécifiés par le constructeur.
12. Utiliser uniquement avec le chariot de transpor t, le suppor t, le trépied, la console ou la table spécifiés par le construc teur ou vendus avec l'appareil. Lors de l'utilisation d'un chariot, bouger avec pré caution l'ensemble chariotlappareil afin d'éviter les dommages d'un renversement.
13 Débrancher cet appareil lors d'orages ou s'il n'est pas utilisé pendant une
longue période.
14. Des précautions doivent être prises afin qu'aucun objet ne tombe et qu'aucun liquide ne se répande à l'intérieur de l'appareil par les orifics de ventilation ou n'importe quelle autre ouver ture.
15. Pour toutes inter ventions techniques s'adresser à un technicien qualifié.L'inter vention technique est nécessaire lorsque l'appareil a été endommagé de n'impor te quelle façon, comme par exemple si le cordon secteur ou sa fiche sont détériorés,si du liquide a coulé ou si des objets sont tombés à l'intérieur de l'apparei1,si l'appareil a été exposé à la pluie ou à l'humidité, s'il ne fonctionne pas normalement ou s'il est tombé.
16. ATTENTI0N:Pour réduire le risque d'incendie ou de choc elec trique ne pas exposer l'appareil à la pluie ou à l'humidité.
FCC Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for assistance.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
EN55022 Class-B
EN55024
IC Statement
This class B digital apparatus complies with Canadian ICES-003.
Introduction
Congratulations on your purchase of the NuVo NV-D2120 Digital Power Amplifier. This robust amplifier will provide 120 watts to each of its two speaker outputs, allowing for versatile uses powering any indoor or outdoor audio zone in multiple speaker configurations. The digital power supply and digital class D amplification allows this single rack space mountable unit will provide quality audio to your speakers while consuming less power than other standalone amplifiers.
Stable at four or eight ohms, and with multiple trigger options, the NV-D2120 offers the ultimate flexibility with the quality of construction you have come to expect from NuVo Technologies.
Table of Contents:
Introduction........................................................................................................................................................................................
Front Panel..........................................................................................................................................................................................
Back Panel...........................................................................................................................................................................................
Wiring Diagram..................................................................................................................................................................................
I. Audio Inputs.....................................................................................................................................................................................
II Sensitivity Control...........................................................................................................................................................................
III. Power Mode...................................................................................................................................................................................
IV. Trigger In.........................................................................................................................................................................................
V. Unit On.............................................................................................................................................................................................
VI. Speaker Impedance......................................................................................................................................................................
VII. Speaker Outputs..........................................................................................................................................................................
Specifications.....................................................................................................................................................................................
Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 11 Page 13 Page 13 Page 13 Page 14 Page 15
NV-D2120 Package Contents
SKU Description Quantity NV-D2120 Digital Power Amplifier 2 x 120 1 NV-CMRS3B-A Mini to RCA Stereo Audio Cable 1 NV-REM1U-C Single Space Rack Ear Mount (pair) 1 NV-PC2-NA-A North American 2-wire Power Cable 1 NV-CMM3B 3.5MM Mini Mono Cable 1
6
MODEL NV-D2 120
Digital Power Am plifier, 2x12 0W
STANDB Y
POWE R
ACTI VE
TEMP
FAULT TEMP FAULT
L R
1
2
3 4
5
7
6
Front Panel Features
1. Power Button: Pushing this button will manually supply power to the amplifier. The amplifier is designed to remain in standby mode
when not in use.
2. Standby: This LED (light emitting diode) will light blue when the D2120 is plugged into an A/C power supply.
3. Active: This yellow LED lights to indicate that the amplifier is in normal amplification mode.
4. Temp: This will light red to indicate that the left channel of the amplifier has overheated.
5. Fault: This will light red to indicate that the left channel of the amplifier is experiencing issues not related to temperature/overheating.
6. Temp: This will light red to indicate that the right channel of the amplifier has overheated.
7. Fault: This will light red to indicate that the right channel of the amplifier is experiencing issues not related to temperature/overheating.
7
CONFORMS T O UL
N1839
STD.6006 5 CERT IFIED
TO CAN/CSA S TD.
RoHS
C22.2 No.6 0065 :06
30331 18
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
seria l numbe r
4
1
3
2
5
7
6
8
Back Panel Features
1. Audio Source Input: The D2120 will accept any line level stereo audio signal. This can be from the preamp lineout of a multi-source,
multi-zone whole house system such as the NuVo Essentia E6G and Grand Concerto systems, or the audio output of any non-amplified source, such as an AM/FM tuner, CD player, or Satellite receiver.
2. Sensitivity Gain Control: Left and Right Channel Sensitivity trim pots allow the incoming signal to be increased or decreased to maximize the potential output of the audio source.
3. Power Mode: This switch dictates how the amplifier responds to external triggers. The D2120 has 3 trigger methods: Incoming audio signal, external voltage input, or the power button on the front of the amplifier.
4. Unit On: This provides a 12V trigger output when the amplifier is powered on. This can be used to turn on external audio equipment, daisy chain multiple external amplifiers, or trigger a relay switching power strip.
5. Trigger In: This voltage trigger input allows the D2120 to power up whenever a voltage of 3-30 volts AC or DC is present.
6. Speaker Impedance: This switch sets the impedance stability at either four or eight ohms.
7. Speaker Output: The speaker output attaches to the amplifier via a modular plug and provides 120 Watts per channel output at either 4
or 8 ohms.
8. AC Power: The D2120 is designed to plug into any AC power source.
8
NV-D2120 Wiring Diagram
NV-D2120 with Grand Concerto System
CONFORMS T O UL
N1839
STD.6006 5 CERT IFIED
TO CAN/CSA S TD.
RoHS
C22.2 No.6 0065 :06
30331 18
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
seria l numbe r
ZONE 2
VARIAB LE
OUTPU T
TIP=L RING= R
FIXED
OUTPU T
L
R
OUTPUT POWER
6
6
20W/6OHM X2
ZONE 3
CONNE CT TO
NV-I8X
USE NV-S LC1
CABLE
SOUR CE LINK
VARIAB LE
OUTPU T
TIP=L RING= R
FIXED
OUTPU T
VARIAB LE
OUTPU T
OUTPUT POWER
TIP=L
20W/6OHM X2
RING= R
FIXED
OUTPU T
ZONE 1
1 2 3 4 5
L
R
1 2 3 4 5
L
R
SOUR CE INPU TS
NV-D2120 with Essentia E6G System
OUTPUT POWER
20W/6OHM X2
1
2
5
4
SOUR CE STATUS IN PUTS
ZONE 4
VARIAB LE
OUTPU T
TIP=L RING= R
FIXED
OUTPU T
3
6
OUTPUT POWER
20W/6OHM X2
1
2 3
5 6 7
ZONE T RIGGE R OUTPU TS
ZONE 5
VARIAB LE
OUTPU T
TIP=L RING= R
FIXED
OUTPU T
OUTPUT POWER
20W/6OHM X2
4
8
SYS ON
EXT. MUTE
SYST EM
VARIAB LE
OUTPU T
TIP=L RING= R
FIXED
OUTPU T
ZONE 7 &8
CONNE CT TO
NETW ORK
NV-I8E ZP1
USE NV-N C1
CABLE
VARIAB LE
OUTPU T
OUTPUT POWER
TIP=L
20W/6OHM X2
RING= R
FIXED
OUTPU T
ZONE 6ZONE 6
1 2 3
5
4
EMIT TER OUT PUTS DIGI TAL LINK
SUM1
SUM2
6
RS-2 32
PROG RAM
CONNE CT TO
NV-I8X
USE NV-S LC1
CABLE
USE CNLY WITH 250V FUSE
MODEL NV-I8D M
SIX SOURCE E IGHT ZO NE
AUDIO DIST RIBUT ION SYS TEM
120V 60Hz 5 00W
FUSE:T5 A
NuVo Technol ogies C incin nati Oh io USA
www.nuvo techn ologi es.co m
CONFOR MS TO
R
UL STD.65 00
US
C
CERTIF IED TO
CAN/CS A STD.E6 0065
3033118
5 6
FIXE D VAR
ZONE
1
ZONE
2
TRIG
IR OUTPU TS
1
2 3 4 5 6
ALL PORT CO NNECT ION
9
RS23 2
SUM
STATUS
NuVoN et
MUTE
LINK
CONFORMS T O UL
N1839
STD.6006 5 CERT IFIED
TO CAN/CSA S TD.
RoHS
C22.2 No.6 0065 :06
30331 18
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
seria l numbe r
MODEL NV- E6GM
SIX SOURC E SIX ZON E AUDIO DIS TRIBU TION SY STEM
NuVo Techno logie s LLC Hebron , Kentu cky USA
www.nuv otech nolog ies.c om
RoHS
CONFORMS T O UL
STD.6006 5 CERTIF IED
TO CAN/CSA STD .
N1839
C22.2 No.6 0065:0 3
3033118
1807
100~24 0V 50~60 Hz 130W
MADE IN CHINA
I. Audio Source Inputs
The D2120 amplifier features a single stereo RCA audio input designed to accept a line level audio signal. Most audio equipment is equipped with a stereo RCA output that allows the audio signal to be taken directly to the D2120’s audio input. This is accomplished using a standard stereo audio cable with left and right audio jacks on each end (Fig. 1).
Fig. 1
AUX IN
USE ON LY NuVo
NV-T2 PAS POWE RED ANTE NNA SYS TEM
AUDI O OUT
L
TRIG GER ON=+ 12V
IN
R
TUN ER BANT ENNA INP UT
AUDIO OUTP UT
The D2120 is a great complement to any NuVo Multi Room Audio System, where extra amplification may be desired for a particular zone. Zone 4 on the Simplese audio system has a fixed and variable RCA stereo audio output. Zones 1 & 2 on the Essentia E6G have fixed and variable 3.5mm stereo audio outputs, and all zones on the Grand Concerto have fixed and variable 3.5mm stereo audio outputs. To add the D2120 to one of these systems, use a 3.5mm to Stereo RCA adapter cable to pass the audio signal from the NuVo Grand Concerto or Essentia E6G to the D2120. Connect the 3.5mm end into the Variable 3.5mm output for the chosen zone (Fig. 2) on the Grand Concerto or Essentia E6G, and connect the left and right RCA’s into the Input on the D2120. For the Simplese system use a standard stereo RCA patch cable to connect the Simplese to the D2120.
Fig. 2
5 6
FIX ED VAR
ZON E
1
10
ZON E
2
II. Audio Sensitivity Control
The D2120 allows the flexibility of controlling the left and right channel gains for the incoming audio signal. The sensitivity allows a control of -12 dB up to +6 dB, and is an excellent tool for maximizing the full output potential of your source equipment (Fig. 3).
Fig. 3
Left and Right Sensitivity Trims
To best utilize this feature, set the volume for the source at its fullest output level. Then adjust the left and right sensitivity trims on the amplifier to allow the fullest possible output from the speakers without distortion.
+6 or a counter-clockwise turn is used to reduce the gain. This would be the preferred setting for a distributed audio system with variable preamp line outputs, such as any of the NuVo systems. Reducing the gain can also be useful for limiting the maximum power going to the speakers.
0 or straight vertically is the factory default. This is the preferred setting for an audio signal from a preamp, such as a distributed audio system with a fixed preamp line output, or the audio output of a music server or CD player.
-12 or a clockwise turn is a high gain position. This is typically used when the incoming audio signal is weak, such as a portable CD player or iPod.
III. Power Mode
The D2120 provides three basic methods for supplying power to the amplifier. This can be accomplished by simply pushing the Power button on the front of the unit, by sensing an incoming audio signal, or by supplying a 3-30 volt AC or DC current. The Power Mode switch on the back of the amplifier (Fig. 4) sets the amplifier to respond to any of the three options.
Fig. 4
11
Setting the power mode switch to the left in the Audio mode (Fig. 5) sets the amplifier to respond to the presence of an audio signal. If you are triggering the amplifier in this way, you should expect a slight delay before it turns on.
When the audio signal is removed the amplifier will remain on for approximately three minutes after the incoming audio signal has ended before the unit turns off. This will prevent the unit from inadvertently turning off when the audio signal is very low or stops temporarily.
Fig. 5
When setting the power mode switch to the center (Fig. 6) the amplifier will turn on or off only when the Power button on the front of the amplifier is pressed.
Fig. 6
Setting the power mode switch to the right (Fig. 7) sets the amplifier to respond to an incoming voltage. This voltage can be AC or DC and anything from 3-30 volts. This is very useful in conjunction with a multiroom audio system or preamp that has a voltage trigger output. In this mode the D2120 will turn on or off with the source equipment.
Fig. 7
12
IV. Trigger In
This input (Fig. 8) is designed for a mono 1/8” plug to accept a trigger voltage coming in from an external source.
Any voltage ranging from 3 to 30 volts, AC or DC, will cause the amplifier to turn on when the Power switch is in the Trigger mode.
Fig. 8
V. Unit On
This output (Fig. 9) provides a constant 12 volts DC when the amplifier is powered on. This is useful for powering on external equipment with the D2120.
Fig. 9
VI. Speaker Impedance
This switch (Fig. 10) allows for the adjusting of the impedance of the amplifier. By default the amplifier will be set at 8 ohms. This is fine is you are powering a pair of 8 ohm speakers, or a single stereo speaker rated at 8 ohms. In installations where three or more 8 ohm speakers will be used, or a pair of 4 ohm speakers are being utilized, the impedance of the amplifier should be set to 4 ohms. The power of the output will remain at 120 watts per channel.
Fig. 10
13
VII. Speaker Outputs
The D2120 provides 120 watts of power per channel at four or eight ohms. It uses a modular plug (Fig. 11) that will accept up to 14 gauge, 4 conductor speaker wire. Stranded 4 conductor 16 gauge speaker wire is recommended.
Fig. 11
The NV-D2120 amplifier is designed to run at a maximum load of 4 ohms. Prolonged operation at less than 4 ohms could cause the amplifier to overheat and damage its internal components. Overheating the amplifier due to an excessive load will void the warranty.
14
Digital Power Amplifier Specifications
Number of Channels 2
Power Output
Continuous Average Output Power 2 x 120W Two channels driven 20-20kHz @1% THD Rated Distortion (1/2 power) 0.02% Rated Impedance switch Selectable 4 or 8 Ohms Damping Factor 50+ Frequency Response (20-20kHz) ±1 dB
Power-On Modes
Audio Power Trigger
System
Trigger Input 3-30 V AC or DC Unit On Output +12VDC @100mA
Source Inputs
Input Impedance 22k ohm Input Sensitivity for rated power .3-2V RMS Input Overload 2.4V RMS
Power Requirements
Power Supply Power Consumption both channels at maximum available output Power Consumption average operating conditions Power Consumption no signal Standby Power Consumption
100-240VAC 50/60Hz
340W
50W 12W
0.35W
Physical Specifications
Unit Size Millimeters Unit Size Inches Shipping Size Millimeters Shipping Size Inches Unit Weight Kilograms Unit Weight Pounds Shipping Weight Kilograms Shipping Weight Pounds
NuVo reserves the right to change specifications without notice.
44 H x 430 W x 250 D
1 3/4 H x 17 W x 9 7/8 D
205 H x 515 W x 343 D
8 H x 20 1/4 W x 13 1/2 D
3.0
6.6
4.8
10.5
CE EMC CE LVD USA FCC ETL Canada Safety Listing (CAN/CSA E60065.00) Australia C-Tick
15
NuVo Technologies Hebron, KY USA
www.nuvotechnologies.com
D2120 1033
Loading...