Legrand AU7394-XX User Manual

301 Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
lyriQ™ Standard Keypad
IS-0391 REV. E
1. Introduction
The lyriQ™ Standard Keypad, P/N AU7394-xx (see Figure 1), is an integral part of the lyriQ™ Multi-Room Audio System. It is a component which, when combined with other essential components (a Source Input Unit, Distribution Module and Speakers) and your source equipment (receiver, CD player, etc.), creates a versatile whole­house audio system that will fill your rooms with high-quality sound for years to come. It uses Category 5 wiring to distribute audio signals, control information and IR for remote control. The Keypad has two on-board class D amplifiers to provide a rich level of clean sound. It also contains a full set of features, including the integrated ability to control all other keypad volume controls in the house. It is available in White (-WH), Light Almond (-LA), Ivory (-IV), or Black (-BK). Build an audio system that accommodates the needs of any space by combining the lyriQ™ Standard Keypad with the lyriQ™ High Performance Keypad (AU1000-xx) in the same system.
2. Description
The front panel of the lyriQ™ Standard Keypad (see Figure 1), contains push buttons for VOLUME UP/DOWN (with five associated green Volume Bar Graph LEDs), SOURCE (with four green Source Selection LEDs) and MUTE (with one red status LED). There is also an IR target window and tri-colored status LED.
The rear of the lyriQ™ Standard Keypad (see Figure 2) contains an RJ45 jack (J1) for connection to the lyriQ™ Audio Distribution Module. The TB2 speaker output connections (left and right, plus and minus) are spring loaded and designed to support up to 14 gauge wire. The TB1 Line Out connections (left and right, plus and minus) are also spring loaded and designed to support up to 14 gauge wire. These connections can be used to attach a powered subwoofer such as On-Q’s 10” (P/N 364664-01) or 12” (P/N 364671-01) subwoofer or an external amplifier.
NOTE: The lyriQ™ Standard Keypad is recommended for indoor use only.
3. Installation
Installation of the lyriQ™ Standard Keypad is best accomplished at multiple times during new construction, at “Rough-in” before the drywall is installed, and at “Trim­out” after the drywall is installed and painted.
NOTE: Before connecting the volume controls: Make sure that power supplies are not connected to the lyriQ™ Audio Modules. For instructions on pre-wiring and installing other components of the lyriQ™ Audio System, please see the Instruction Sheets included with those components.
NOTE: Always follow TIA-570-B wiring standards for installing and terminating Category 5 cable. Failure to follow the correct wiring standard could result in damaged equipment and/or electrical interference issues.
NOTE: Maintain a minimum 12” separation between Category 5 cable and any 120VAC cabling.
Figure 1
Figure 2
Page 1 of 8
©Copyright 2009 by Legrand All Rights Reserved.
301 Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
lyriQ™ Standard Keypad
A. “Rough-in” steps:
1) A single Category 5 cable should be run from the enclosure location to a single gang outlet box or mud ring at each Volume Control location.
NOTE: We also recommend running a 16/4 speaker wire along with the Category 5 cable to support future upgrades to High Performance Keypads if desired.
B. “Trim-out” steps:
1) Connect the volume control by terminating the pre-wired Category 5 cable from the enclosure with an RJ45 plug, following the T568A wiring standard and insert this plug into jack J1 (see Figure 2).
2) For the Line Out/Speakers Out connections (TB1/TB2) strip 3/8” of insulation from each of the four conductors and insert the appropriate wires into the appropriate connections (see Figure 2).
NOTE: Polarity and channels are clearly marked (L+, L-, R-, R+) for proper identification during installation.
a) Use TB2 to connect one pair (only) of 8 ohm evōQ™ audio speakers to the volume control.
b) Use TB1 to connect your evōQ™ powered sub-woofer or an external amplifier to the volume control.
These connection terminals do not provide any amplification but the volume control on the keypad controls the output level of this connection.
3) Connections in the enclosure (see Figure 3):
a) The Category 5 cable that was run to each volume control location should be terminated with an RJ45
plug according to the T568A wiring standard and inserted into one of the zone output jacks of the associated lyriQ™ audio distribution module.
Figure 3
IS-0391 REV. E
Page 2 of 8
©Copyright 2009 by Legrand All Rights Reserved.
301 Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
lyriQ™ Standard Keypad
b) To connect more than four (4) Keypads to a Single Source 4 Zone Module or more than eight (8)
Keypads to a 4 Source 8 Zone Module, cascade Single Source Modules. To cascade a Single Source Module, simply run a Category 5 jumper from the “Cascade Out” RJ45 jack on the front panel of the first Module to the “Source In” RJ45 jack on the front panel of the second Module (see Figure 4).
4) Keypad Mounting: check all connections and test the system’s operation before installing the volume controls into the wall. Use the included screws to install the volume control and wall plate into the single gang box.
NOTE: A 20 in.³ or greater single gang box is recommended.