Congratulations!
heater available.
Your new L.B.White heater incorporates the benefits from the most experienced
manufacturer of heating products using state-of-the-art technology.
We, at L.B.White, thank you for your confidence in our products and welcome any
suggestions or comments youmay have...call us, toll-free, at (800) 345-7200
or e-mail customerservice@lbwhite.com
ATTENTION ALL USERS
This heater has been tested and evaluated by C.S.A. International in accordance with
the requirements of Standard UL733 and ANSI A10.10-1998, CAN/CSA B140.0-03
and CSA B140.8 - 1967 and is listed and approved as a Kerosene forced-air
construction heater with application for the temporary heating of buildings under
construction, alteration, or repair. If you are considering using this product for any
application other than its intended use, then please contact the L.B. White Co., Inc.
Failure to comply with the precautions and instructions provided with this heater, can result in:
— Death
— Serious bodily injury or burns
—
— Asphyxiation due to lack of adequate air supply or carbon monoxide poisoning
— Electrical shock
Read this Owner’s Manual before installing or using this product.
Only properly-trained service people should repair or install this heater.
Save this Owner’s Manual for future use and reference.
Owner’s Manuals and replacement labels areavailable at no charge. See website, or for assistance, contact
L.B. White at 800-345-7200.
WARNING
Fire and Explosion Hazard
Not for home or recreational vehicle use.
Installation of this heater in a home or recreational
Fire or explosions can cause property damage or loss
of life.
FOR YOUR SAFETY
and liquids in the vicinity of this or any other appliance.
WARNING
Fire and Explosion Hazard
Keep solid combustibles a safe distance away from
the heater.
Solid combustibles include wood, paper, or plastic
products, building materials and dust.
Do not use the heater in spaces which contain or may
contain volatile or airborne combustibles.
Volatile or airborne combustibles include gasoline,
solvents, paint thinner, dust particles or unknown
chemicals.
or explosion.
Fire or explosions can lead to property damage,
personal injury or loss of life.
This Owner’s Manual includes all options and accessories
commonly used on this heater.
When calling for technical service assistance, or for other
specific information, always have model number,
configuration number and serial number available. This
information is contained on the dataplate.
This manual will instruct you in the operation and care of
your unit. Have your qualified installer review this manual
with you so that you fully understand the heater and how it
functions.
The installation, repair, and servicing of the heater
requires continuing expert training and knowledge of
kerosene heaters and should not be attempted by anyone
who is not so qualified.
Contact your local L.B. White distributor or the L.B. White
Co., Inc. for assistance, or if you have any questions about
the use of the equipment or its application.
The L.B. White Co., Inc. has a policy of continuous product
improvement. It reser ves the right to change
specifications and design without notice.
2
Heater Specications
Model
SPECIFICATIONSCP050EKCP075EK
Fuel Type1-K, Kerosene
Max Input (BTUH)50,00075,000
Pump Pressure (psig)3.83.8
Fuel Consumption per Hour (gal).38.57
Motor Characteristics
Electrical Supply (Voltz/Hz/Phase)120/60/1
Amp Draw
Dimensions (Inches) Length x width x height32” x 11.8” x 16.8”
Minumum Safe
Distances From
Nearest
Combustible
Materials
Net Weight (Lbs.)27. 627. 6
Shipping Weight (Lbs.)32.032.0
Minimum Ambient Temperature
in Which Heater May Be Used
CONTINUOUS
OPERATION
TOP4 ft.
SIDES4 ft.
BACK4 ft.
BLOWER OUTLET8 ft.
BULK FUEL STORAGE CONTAINER25 ft.
1/8 HP, 3,300 RPM1/8 HP, 3120 RPM
1.61.6
Ball Bearing
-20˚F
3
Model
SPECIFICATIONSCP125FKCP175FKCP210FK
Fuel Type1-K, Kerosene
Max Input (BTUH)125,000175,000210,00
Pump Pressure (psig)5.56.58.5
Fuel Consumption per Hour (gal).951.321.6
Motor Characteristics
Electrical Supply (Voltz/Hz/Phase)120/60/1
Amp Draw
Dimensions (Inches) Length x width x height36.1” x 21.5” x 24.6”41.8” x 23.1” x 26.1”
Minumum Safe
Distances From
Nearest
Combustible
Materials
Net Weight (Lbs.)56.462.864.4
Shipping Weight (Lbs.)63.771.673.2
Minimum Ambient Temperature
in Which Heater May Be Used
CONTINUOUS
OPERATION
TOP4 ft.
SIDES4 ft.
BACK4 ft.
BLOWER OUTLET8 ft.
BULK FUEL STORAGE CONTAINER25 ft.
1/5HP 3455 RPM1/4HP 3430 RPM1/3HP 3380 RPM
2.53.23.7
Ball Bearing
-20˚F
4
Safety Information
HAZARD DEFINITIONS
DANGER
Indicates an imminently hazardous situation which, if
not avoided WILL result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if
not avoided, COULD result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if
not avoided, MAY result in minor or moderate injury.
GENERAL SAFETY INFORMATION
WARNING
Before using this heater, please read this USER’S
MANUAL very carefully. This USER’S MANUAL has
been designed to instruct you as to the proper
manner in which to assemble, maintain, store, and
most importantly, how to operate the heater in a
safe and efcient manner.
WARNING
Never leave the heater unattended while burning!
DANGER
Improper use of this heater can result in serious
injury or death from burns, re, explosion, electrical
shock, and/or carbon monoxide poisoning.
5
GENERAL SAFETY INFORMATION (cont.)
WARNING
Risk of CO Poisoning!
- Use this heater only in well ventilated areas.
Provide proper ventilation. Proper ventilation air for
combustion must be provided in accordance with
OSHA 29 CFR 1926.154, Temporary Heating Devices.
ANSI A 10.10, Safety Requirements for Temporary
and Portable Space Heating Devices, or the Natural
Gas and Propane Installation Code, CAN/CSA B149.1
as appropriate.
- Never use this heater in living or sleeping areas.
- Carbon Monoxide Poisoning: Early signs of carbon
such as headaches, dizziness, and/or nausea. If you
have these symptoms, your heater may not be
working properly.
- Get fresh air at once! Have the heater serviced.
- People with breathing problems should consult a
physician before using the heater.
WARNING
Risk of Electric Shock!
- Use only the electrical power (voltage and
heater. Use only a three prong, grounded outlet and
extension cord.
- ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
CANADIAN RESIDENTS: Use of this heater shall be in
accordance with authorities having jurisdiction and
CSA Standard B139.
NEW YORK CITY RESIDENTS: For use only at construction
sites in accordance with applicable NYC codes under
WARNING
Risk of Burns/Fire/Explosion!
- Keep all combustible materials away from this heater.
Minimum Clearances
Outlet 8 feet (250 cm)
Sides, Top and Rear 4 feet (125 cm)
- NEVER use fuels such as gasoline, benzene, paint
thinners, or other oil compounds in this heater
(RISK OF FIRE OR EXPLOSION).
be present.
operating or still hot. This heater is EXTREMELY HOT
while in operation.
- NEVER block air inlet (rear) or air outlet (front) of
heater.
- NEVER use ductwork in front or at rear of heater.
- ALWAYS unplug the heater when not in use.
WARNING: This product and the fuel used to operate
this product (kerosene or other approved fuels), and the
products of combustion of such fuel, can expose you to
chemicals including benzene, which is known to the State
of California to cause cancer and reproductive harm.
For more information go to www.p65Warnings.ca.gov
MASSACHUSETTS RESIDENTS: Massachusetts state law
prohibits the use of this heater in any building which is
used in whole or in part for human habitation. Use of this
permit (M.E.L.C. 148, Section 10A).
- NEVER move or handle heater while still hot.
- NEVER transport heater with fuel in its tank.
- When used with optional thermostat or if equipped
with a thermostat, the heater may start at any time.
- ALWAYS locate heater on a stable and level surface.
- NEVER use any fuel other than 1-K kerosene,
#1/#2 disel/fuel oil, JET A or JP-8 fuels in this heater.
- Bulk fuel storage should be a minimum of 25 ft. from
heaters, torches, portable generators, or other
sources of ignition. All fuel storage should be in
accordance with federal, state, or local authorities
having jurisdiction.
6
Installation and Assembly Instructions
HEATER SPECIFICATIONS
Introduction
Please read this USER’S MANUAL carefully. It will show you
how to assemble, maintain and operate this heater safely
Consumer: Retain these instructions for future reference.
Unpacking
1. Remove all packing items applied to heater for shipment.
2. Remove all items from carton.
3. Check all items for shipping damage.
If heater is damaged, promptly inform dealer where you
purchased heater.
Dimensions
16.8"
32"
Model CP075EK
Figure 1.1 - Heater Dimensions
11.8"
Product Features
Fan Guard
Hot Air Outlet
Lower Shell
Fuel Tank
Side Cover
Lamp
Thermostat Knob
(CP075EK model only)
LED Power/Reset Switch
Figure 2.1 - Features
Upper Shell
Power Cord
Handle
Pressure Guage
Fuel Guage
Cord Wrap
Fuel Cap
Dimensions
L
Figure 1.2 - Heater Dimensions
CP125FK
CP175FK
CP210FK
Height24.6”26.1”
Length36.1”41.8”
Width21.5”23.1”
Product Features
Handle Front
H
W
Hot Air Outlet
Lower Shell
Fuel Gauge
Fuel Cap
Side Cover
Thermostat Knob
Figure 2.1 - Features
Lamp
Upper Shell
Pressure Gauge
Room Temp. Display
Cord Wrap
Handle Rear
Power Cord
(Piggy Back)
Power/Reset Switch
7
Installation and Assembly Instructions
572281
572281
ASSEMBLY
TOOLS REQUIRED
CP075EK
- Medium Phillips screwdriver.
1.
on the upper housing.
2. Remove the pre-assembled screws on the shell upper and side cover.
3. Align the holes in upper housing with two mounting holes on the handle as shown in Figure 4.
4. Secure handle with screws removed.
5. Insert cord wrap into the rectangle holes on the supporter and align the hole on the cord wrap with
the mounting hole on the side covers shown in Figure 4.
6. Secure cord wrap with screws removed.
CP125FK/CP175FK/CP210FK
- Medium Phillips screwdriver.
- M5 open, or adjustable wrench.
1. Slide threaded axle through the rear section of the wheel support frame.
2. Slide one axle bushing on to each side of the axle. Slide one wheel on to each side of the axle.
3. Attach one cap nut on to each side of the threaded axle and tighten well.
4. Place heater on wheel support frame. Make sure the air inlet end (rear) of heater is over wheels. Align the holes on fuel
5.
6. Align the hole on the handle (front and rear) with the mounting hole on the cord wrap.
7.
8.
WARNING
Fire or explosion hazard!
- Do not operate heater without support
frame fully assembled to tank.
CP075EK Model
HandleCord Wraps
ModelCP075EKCP125FKCP175FKCP210FK
Wheel Support FrameNoYesYesYes
WheelsNoYesYesYes
Front-HandleNoYesYesYes
Rear-HandleNoYesYesYes
AxleNoYesYesYes
Cord WrapYesYesYesYes
Hardware KitNoYesYesYes
HandleYesNoNoNo
Remove Screws
Remove Screws
CP125FK/CP175FK/CP210FK Models
Screws
Cap Nuts SCap Nuts LBushings
Cord WrapsWheels
NutsFlange Screws
Front
Handle
Figure 4 - Handle and Cord Wrap Installation CP075EK
Handle
Screw
Wheel Support Frame
Side Cover
Screw
Front Guard
Wedged Portion
Slit Hole
Upper Shell
Cord Wrap
Axle
Rear
Handle
8
Assembly
(cont.)
Front Handle
Hot Air Outlet
Fuel Tank Flange
Wheel Support Frame
Screw
Flange Screw
Cord Wrap
Rear Handle
Cap Nut S
Air Inlet
Nuts
Wheel
Figure 5 - Assembly
Cap Nut L
OPERATION
Figure 6 - Overview of Heater Design
OVERVIEW OF HEATER DESIGN
Fuel System: This heater is equipped with an electric air
pump that forces air through the air line connected to the
fuel intake, and then through a nozzle in the burner head.
When air passes in front of the fuel intake, it causes fuel to
rise from the tank and into the burner nozzle.
This fuel and air mixture is then sprayed into the
SureFire Ignition: The electronic ignitor sends voltage to
a specially designed spark plug. The spark plug ignites the
fuel and air mixture described above.
The Air System: The heavy duty motor turns a fan that
forces air into and around the combustion chamber. Here,
the air is heated and then forced out the front of the
heater.
THE SAFETY SYSTEM
Temperature Limit Control:This heater is equipped with
a Temperature Limit Control designed to turn the heater
off should the internal temperature rise to an unsafe level.
If this device activates and turns your heater off, it may
require service.
Once the temperature falls below the reset temperature,
you will be able to start your heater.
Electrical System Protection: This heater’s electrical
system is protected by a fuse mounted to the PCB
Assembly that protects it and other electrical components
from damage. If your heater fails to operate, check this
Flame-Out Sensor:
bun chamber during normal operation. It will cause the heater
FUEL SELECTION
1. All models can use 7 different fuels: K1 Kerosene, #1 Fuel
Oil, #1, Diesel, #2 Fuel Oil, #2 Diesel, Jet A, JP-82.
2. K1 Kerosene is recommended for optimal combustion and
performance, and for less maintenance. K1 is also the
optimal fuel choice in extremely low temperatures of 15°F or
less, as its pour-point/"gel-point" varies depend-ing on the
refinery, but it is always far below the lowest temperatures
reached North America.
3. Jet A and JP-8 are also excellent choices for clean combustion, reduced maintenance, and temperatures below 15°F,
but they are rarely found outside of the aviation industry or
the military.
4. #1 Fuel Oil, #1 Diesel, #2 Fuel Oil, #2 Diesel are often
selected, as they are readily available. However, the uwer
must under-stand that Fuel Oil and Diesel are less refined,
and therefore the user should be aware of the following:
a. #1 Diesel and #1 Fuel Oil will have some degree of increased
smoke/soot during ignition, increased smell, and increased
regular cleaning/mainte-nance.
b. #2 Diesel and #2 Fuel Oil will, generally depending on the
regional refinery, burn dirtier than #1 fuels. The use of #2
fuels will result in a little more smoke/soot during ignition, a
greater increase in smell, and will require more regular
cleaning/-mainte-nance than #1 fuels.
c. At temperatures lower than 15°F, most diesel/fuel oil blends
will become more viscous (start to gel) as the diesel falls
below its pour point (starts to "gel"), and may pose a
challenge igniting the heater and with continu-ous operation of
the heater. There are troubleshooting steps for this situation,
but selecting K1 (or JP-8/Jet A) is recommended when
operating below 15°F. The colder the temperatures the more
likely you could problems you will experience diesel gelling.
d. Diesel fuel gelling happens when the paraffin usually present
in diesel starts to solidify when the temperature drops. At
32°F, the wax in liquid form will crystallize and leave the fuel
clouded; this can start to have an effect on the fuel filter and
the nozzle. If the nozzle is getting coated the spray pattern
willnot be correct which can cause white smoke and
perfor-mance problems.
OPERATION (cont.)
KEROSENE SHOULD ONLY BE STORED IN A BLUE
CONTAINER THAT IS CLEARLYMARKED
“KEROSENE”. NEVER STORE KEROSENE IN A RED
CONTAINER.
Red containers are associated with gasoline.
NEVER store kerosene in the living space. Kerosene
should be stored in a well ventilated place outside the
living area.
NEVER use any fuel other than 1-K kerosene (#1/#2
diesel/fuel oil, JET A or JP-8 fuels are acceptable substitutes)
NEVER use fuel such as gasoline, benzene, alcohol, white
gas, camp stove fuel, paint thinners, or other oil
compounds in this heater. These are volatile fuels that can
cause an explosion or uncontrolled flames.
NEVER store kerosene in direct sunlight or near a source
of heat.
NEVER use kerosene that has been stored from one
season to the next. Kerosene deteriorates over time.
“OLD KEROSENE” WILL NOT BURN PROPERLY IN
THIS HEATER.
3. Plug power cord into three prong, grounded extension
cord. Extension cord must be at least six feet long.
-Extension Cord Wire Size Requirements:
-6 to 100 feet (1.8 to 30.53 meters) long, use 16
AWG conductor.
-101 to 200 feet (30.8 to 61 meters) long, use 14
AWG conductor.
NO THERMOSTAT ON 50
4. Turn thermostat control knob to desired setting and
push power switch to “ON” position. Power lamp will
light and heater will start.
NOTE: Room Temp. display indicates as following:
-When room temp. is less than 0˚F: “lo”.
-When room temp. is between 0˚F and 99˚F:
“Temp. is Displayed”
-When room temp is greater than 99˚F : “Hi”
If heater does not start, the thermostat setting may be
too low. Turn THERMOSTAT CONTROL KNOB to higher
position to start heater. If heater still does not start,
turn power switch to “OFF” and then to “ON” position
(See Figure 7.1 &7.2). If heater still does not start, see
Troubleshooting on page 18.
FUELING YOUR HEATER
Never fill the heater fuel tank in the living space: fill the tank
outdoors.
Do not overfill your heater and be sure the heater is level,
WARNING
Fire or explosion hazard!
still hot.
IMPORTANT: REGARDING FIRST IGNITION OF HEATER.
The first time you light the heater, it should be done
OUTDOORS. This allows the oils, etc., used in
manufacturing heater to be burned off outside.
TO START HEATER
1. Fill fuel tank with fuel.
NOTE : Kerosene is recommended when the
temperature drops below 0˚F(-18˚C) to
prevent ignition delay or failure.
2. Attach fuel cap.
NOTE: The major electrical components of this heater
are protected by a safety fuse mounted to the PCB
board. If your heater fails to start, check this fuse first
and replace as necessary. You should also check your
power source to insure that proper voltage and
frequency are being supplied to the heater.
NOTE: In cold weather, ignition may be improved by holding
a finger over the end of the relief valve or block fan guard in
half with newspaper etc. until the heater ignites.
TO SHUT DOWN HEATER
Turn switch to “OFF” and unplug power cord.
Model CP050EKModel CP075EK
Thermostat Control KnobPower/Reset Switch
Lamp
Power/Reset
Switch
Lamp
Figure 7.1 - Controls
10
OPERATION (cont.)
LONG-TERM STORAGE OF YOUR HEATER
Model CP125FK, CP175FK, CP210FK
Lamp
Thermostat Control Knob
Figure 7.1 - Controls
Room Temp. Display
Power/Reset Switch
TO RESTART HEATER
1. Wait 10 seconds after stopping heater.
2. Repeat steps under, “TO START HEATER.”
PIGGYBACK POWER CORD
Cover
Electric Outlet
3. Reinstall fuel cap. Properly dispose of old and
dirty fuel.
- Make sure storage place is free of dust and corrosive
fumes.
- Store the heater in the original box with the original
packing material and keep USER’S MANUAL with
heater.
FUEL TANK DRAIN CP125FK & CP175FK & CP210FK
1. Remove drain bolt from bottom of fuel tank. See
Figure 9.
Seal
Fuel Drain Bolt
Figure 7.2 - Controls
WARNING
SHOCK HAZARD!
- Always cover electric outlet when not in use.
Don’t plug and use an appliance of more than
5A current in this outlet.
FUEL TANK DRAIN CP075EK
1. Drain fuel tank through fuel cap opening.
2. Using a small amount of kerosene, swirl and rinse the
inside of the tank.
NEVER MIXWATER WITH KEROSENE, as it will cause rust
inside the tank. Pour the kerosene out, making sure that
you remove it all.
IMPORTANT: Do not store kerosene over summer for use
during next heating season. Using old fuel may damage
heater.
Figure 9 - Drain Plug Removal
2. Using a small amount of kerosene, swirl and rinse the
inside of the tank.
NEVER MIXWATER WITH KEROSENE, as it will cause rust
inside the tank. Pour the kerosene out, making sure that
you remove it all.
IMPORTANT: Do not store kerosene over summer for use
during next heating season. Using old fuel may damage
heater.
3.
not seal completely.
- Make sure storage place is free of dust and corrosive
fumes.
- Store the heater in the original box with the original
packing material and keep USER’S MANUAL with heater.
11
MAINTENANCE
USE ORIGINAL EQUIPMENT REPLACE MENT PARTS. Use of third-party or other alternate components will void warranty and
may cause unsafe operating conditions.
WARNING
Fire or explosion hazard!
- Never service heater while it is plugged in or while hot!
FUEL TANK
FLUSH EVERY 200 HOURS OF OPERATION OR AS NEEDED
(See Longterm Storage, page 11).
AIR INTAKE FILTER
Screw
Upper Shell
Air Intake Filter
Fan Guard
REPLACE EVERY 500 HOURS OF OPERATION OR ONCE A
YEAR
- Remove upper shell and fan guard (See Air Intake Filter
Figure 10).
- Turn air pressure gauge counter-clockwise and remove.
- Remove end filter cover screws using medium Phillips
screwdriver.
- Remove end filter cover.
- Replace air output and lint filter.
- Reinstall end filter cover and air pressure gauge.
- Reinstall fan guard and upper shell.
PUMP SERVICING
•PUMP ROTOR
Pump Body
Screw
Vane
End Pump Cover
Figure 10 - Air Filter Access
WASH AND DRY WITH SOAP AND WATER EVERY 500 HOURS
OF OPERATION, OR AS NEEDED.
- Remove screws along each side of heater using medium
Phillips screwdriver.
- Lift off upper shell.
- Remove fan guard.
- Wash or replace air intake filter.
- Reinstall fan guard and upper shell.
AIR OUTPUT FILTER, LINT FILTER
Air Output Filter
End Filter Cover
Screw
Lint Filter
Air Pressure Gauge
Air Intake Filter
Rotor Insert
Rotor
Figure 12 - Rotor Pump Assembly
Screw
REPLACE IF CHIPPED, CRACKED OR AS NEEDED
- Remove upper shell and fan guard (See Air Intake
Filter Figure 10).
- Turn air pressure gauge counter-clockwise and
remove.
- Remove end filter cover screws using medium Phillips
screwdriver (see air output filter, lint filter Figure 11).
- Remove air output filter and lint filter.
- Remove end pump cover screws using a 5/16”
(8mm) nut driver/socket.
- Replace rotor, all 4 vanes and plastic rotor insert. All
of these components must be replaced at the same
time.
Figure 11 - Filter Assembly
12
MAINTENANCE (cont.)
PUMP SERVICING (CONT.)
•ROTOR GAPPING
•END FILTER COVER & GASKET(LEAKING)
IMPORTANT: The newly inserted rotor must be gapped
properly before you reinstall the end pump cover.
REPLACE IF SPLIT,CRACKED OR AS NEEDED.
- Replace End lter cover.(See Air output lter,page 12)
- Replace Air ouput lter.(See Air output lter,page 12)
Rotor Gap
Pump Body Screw
FAN BLADES
Flush
Rotor
Figure 13 - Rotor GappingFigure 15 - Fan Assembly
- Slightly loosen the pump body screws using a medium
screw driver.
- Position pump body to set rotor gap to .003’’~.004’’ at top
dead center and retighten pump body screws.
- Verify the gap using calipers, a micrometer or a dollar bill.
- Reinstall the end pump cover.
- Reinstall air output lter and lint lter.
- Reinstall end lter cover and air pressure gauge.
- Reinstall fan guard and upper shell.
•AIR LINE (LEAKING)
REPLACE IF SPLIT,CRACKED OR AS NEEDED.
- Remove air line from air line tting (See Figure 14) and from
nozzle adaptor.(See Nozzle, page 14)
- Reinstall Air line to air line tting and nozzle adaptor.
Pump Body
CLEAN EVERY SEASON OR AS NEEDED
- Remove upper shell (See Air Intake Filter Figure 10).
- Use M6 Allen wrench to loosen set screw which holds
fan blade to motor shaft.
- Slip fan blade off motor shaft.
- Clean fan blade using soft cloth moistened with
kerosene or solvent.
- Dry fan blade thoroughly.
- Reinstall fan blade to motor shaft.
- Place fan blade hub ush with end of motor shaft.
NOTE: USE ONLY ORIGINAL EQUIPMENT
REPLACEMENT PARTS. Use of alternate or third party
components will void warranty and may cause an
unsafe operating condition.
16
MAINTENANCE (cont.)
REPLACING FUSE
NOTE: The heater is fuse protected. If your heater fails to ignite, DO NOT
RETURN YOUR HEATER TO THE STORE.
Please follow the simple instructions below to inspect and change the fuse.
- Unplug heater.
- Remove side cover screws using medium Phillips screwdriver
WARNING
Burn hazard!
- SHOCK HAZARD. To prevent presonal injury, unplug the
power cord before replacing fuse.
- Remove fuse from fuse holder (See Figure 23).
- Replace fuse with enclosed fuse.
- Replace switch wires to power switch.
- Replace side cover.
NOTE: Specied fuse rating: AC 125/8A, part number 572447
Side Cover
Power Switch
Screw
Fuse Holder
Fuse
Model: CP075EK
Switch Wires
Fuse
Fuse Holder
Model: CP050EK
Figure 23 – Replacing Fuse
Fuse Holder
Fuse
17