Congratulations!
You have purchased the finest circulating construction heater available.
Your new L.B. White heater incorporates the benefits from the most experienced manufacturer of heating products using state-of-the-art technology.
Owner's Manual and Instructions
Dual Fuel Construction Heater
150-24034-C
MODELS OUTPUT (Btuh) FUEL
TS350 350,000
Certification by:
ATTENTION ALL USERS
This heater has been tested and evaluated by C.S.A. International in accordance with the requirements of Standard ANSI Z83.7 and is listed and approved as a ductable direct gas-fired forced-air construction heater with application for the temporary heating of buildings under construction, alteration, or repair. If you are considering using this product for any application other than its intended use, then please contact your fuel gas supplier, or the L.B. White Co., Inc.
GENERAL HAZARD WARNING
Failure to comply with the precautions and instructions provided with this heater, can result in:
Death — Serious bodily injury or burns — Property damage or loss from fire or explosion — Asphyxiation due to lack of adequate air supply or carbon monoxide poisoning — Electrical shock
Read this Owner’s Manual before installing or using this product.
Only properly-trained service people should repair or install this heater.
Save this Owner’s Manual for future use and reference.
Owner’s Manuals and replacement labels are available at no charge. For assistance, contact
L.B. White at 1-800-345-7200.
WARNING
Fire and Explosion Hazard
Not for home or recreational vehicle use.
Installation of this heater in a home or
recreational vehicle may result in a fire or explosion.
Fire or explosions can cause property
damage or loss of life.
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WARNING
Proper gas supply pressure must be provided to the inlet of the heater.
Refer to data plate for proper gas supply pressure.
Gas pressure in excess of the maximum inlet pressure specified at the heater inlet can cause
fires or explosions.
Fires or explosions can lead to serious injury, death, or building damage.
Gas pressure below the minimum inlet pressure specified at the heater inlet may cause
improper combustion.
Improper combustion can lead to asphyxiation or carbon monoxide poisoning and therefore
serious injury or death.
2
WARNING
Fire and Explosion Hazard
Keep solid combustibles a safe distance
away from the heater.
Solid combustibles include wood, paper, or
plastic products, building materials and dust.
Do not use the heater in spaces which
contain or may contain volatile or airborne combustibles.
Volatile or airborne combustibles include
gasoline, solvents, paint thinner, dust particles or unknown chemicals.
Failure to follow these instructions may
result in a fire or explosion.
Fire or explosions can lead to property
damage, personal injury or loss of life.
3
SECTION
PAGE
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Heater Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installation Instructions
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Gas Supply Sizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Connecting Hose to Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Connecting Regulator to Gas Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Installation of Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Inside Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Outside Structure (Using air distribution accessories) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
A. Extendable Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
B. End Diffuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Start-Up Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Shut-Down Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Gas Selector Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Cleaning Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Maintenance Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Service Instructions
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Belt Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Belt Tensioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Fan and Motor Pulley . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Drive Component Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Air Proving Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Igniter Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Testing the Manual Reset High Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Burner Orifice and Gas Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Fan Wheel, Bearings, and Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Gas Pressure Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Troubleshooting Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Electrical Connection and Ladder Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Heater Component Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229
Parts Identification
Parts Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 & 32
Warranty Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Replacement Parts and Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Table of Contents
SPECIFICATIONS
MMooddeell
Ventilation Air Required to Support Combustion (CFM)
Electrical Supply (Volts/Hz/Phase)
Amp Draw
Dimensions (Inches) L x W x H
Minimum Safe Distances From Nearest Combustible Materials
STARTING
CONTINUOUS OPERATION
Motor Characteristics
Fuel Consumption Per Hour
Inlet Gas Supply Pressure Acceptable at the Inlet of the Heater for Purpose of Input Adjustment (in.W.C.)
MAX.
MIN.
6 ft.
Heater Specifications
Fuel Type
- 20º F
Blower Speed
Burner Manifold Pressure (in.W.C.)
4
General Information
This Owner's Manual includes all options and accessories commonly used on this heater.
When calling for technical service assistance, or for other specific information, always have model number, configuration number and serial number available. This information is contained on the dataplate.
This manual will instruct you in the operation and care of your unit. Have your qualified installer review this manual with you so that you fully understand the heater and how it functions.
The gas supply line installation, installation of the heater, and repair and servicing of the heater requires continuing expert training and knowledge of gas heaters and should not be attempted by anyone who is not so qualified. See page 6 for definition of the necessary qualifications.
Contact your local L.B. White distributor or the L.B. White Co., Inc. for assistance, or if you have any questions about the use of the equipment or its application.
The L.B. White Co., Inc. has a policy of continuous product improvement. It reserves the right to change specifications and design without notice.
TS350
Propane Natural
Gas Gas
Maximum Input (BTUH) 350,000
2,400
13.5
11.0 11.0
5.2 5.3
16.2 lbs. 350 cu.ft.
Ball Bearing
1 H.P. / 1,725 RPM
915 RPM
115/60/1
35.0
14.0
48 x 22 ¼ x 32 ¾
TOP 1 ft. SIDES 1 ft. BACK 1 ft. BLOWER
OUTLET
GAS Propane Gas SUPPLY 10 ft., 3.04 m
Net Weight 295 Shipping Weight 310
Minimum Ambient Temperature in Which Heater May Be Used
Propane ggas aand nnatural ggas hhave mman-mmade oodorants aadded sspecifically ffor ddetection oof ffuel ggas lleaks.
If aa ggas lleak ooccurs, yyou sshould bbe aable tto ssmell tthe ffuel ggas.
THAT’S YYOUR SSIGNAL TTO GGO IINTO IIMMEDIATE AACTION!
Do not take any action that could ignite the fuel gas. Do
not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.
Get everyone out of the building and away from the area
immediately.
Close all propane gas tank or cylinder fuel supply
valves, or the main fuel supply valve located at the meter if you use natural gas.
Propane gas is heavier than air and may settle in low
areas. When you have reason to suspect a propane leak, keep out of all low areas.
Use your neighbor’s phone and call your fuel gas
supplier and your fire department. Do not re-enter the building or area.
Stay out of the building and away from the area until
declared safe by the firefighters and your fuel gas
supplier.
FI N ALLY,
let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair the leak, check for further leakages, and then relight the appliance for you.
Some ppeople ccannot ssmell wwell. SSome ppeople ccannot smell tthe oodor oof tthe mman-mmade cchemical aadded tto propane oor nnatural ggas. YYou mmust ddetermine iif yyou ccan smell tthe oodorant iin tthese ffuel ggases.
Learn to recognize the odor of propane gas and natural
gas. Local propane gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor.
Smoking can decrease your ability to smell. Being
around an odor for a period of time can affect your sensitivity to that particular odor.
The oodorant iin ppropane ggas aand nnatural ggas iis ccolorless and tthe iintensity oof iits oodor ccan ffade uunder ssome circumstances.
If there is an underground leak, the movement of gas
through the soil can filter the odorant.
Propane gas odor may differ in intensity at different
levels. Since propane gas is heavier than air, there may be more odor at lower levels.
Always bbe ssensitive tto tthe sslightest ggas oodor.
If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously.
5
Safety Precautions
FUEL GAS ODOR
ODOR FADING -- NO ODOR DETECTED
ATTENTION -- CRITICAL POINTS TO REMEMBER!
Propane gas has a distinctive odor. Learn to recognize
these odors. (Reference Fuel Gas Odor and Odor Fading sections above.
If you have not been properly trained in repair and service of propane gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane gas fuel system.
Even if you are not properly trained in the service and
repair of the heater, ALWAYS be consciously aware of the odors of propane gas and natural gas.
A periodic sniff test around the heater or at the
heater’s joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT!
WARNING
Do not use this heater for heating human living
quarters.
Do not use in unventilated areas.
The flow of combustion and ventilation air must not be
obstructed.
Proper ventilation air must be provided to support the
combustion air requirements of the heater being used.
Refer to the specification section of the heater’s
Owner’s Manual, heater dataplate, or contact the L.B. White Company to determine combustion air ventilation requirements of the heater.
Lack of proper ventilation air will lead to improper
combustion.
Improper combustion can lead to carbon monoxide
poisoning leading to serious injury or death. Symptoms of carbon monoxide poisoning can include headaches, dizziness and difficulty in breathing.
Asphyxiation HHazard
1. Do not attempt to install, repair, or service this heater or the gas supply line unless you have continuing expert training and knowledge of gas heaters.
Qualifications for service and installation of this equipment are as follows:
a.
To be a qualified gas heater service person, you must have sufficient training and experience to handle all aspects of gas-fired heater installation, service and repair. This includes the task of installation, troubleshooting, replacement of defective parts and testing of the heater. You must be able to place the heater into a continuing safe and normal operating condition. You must completely familiarize yourself with each model heater by reading and complying with the safety instructions, labels, Owner’s Manual, etc., that is provided with each heater.
b.
To be a qualified gas installation person, you must have sufficient training and experience to handle all aspects of installing, repairing and altering gas lines, including selecting and installing the proper equipment, and selecting proper pipe and tank size to be used. This must be done in accordance with all local, state and national codes as well as the manufacturer’s requirements.
c. In the Commonwealth of Massachusetts, this
product must be installed by a gas fitter licensed by the Commonwealth of Massachusetts.
2. All installations and applications of L.B. White heaters must meet all relevant local, state and national codes. Included are L.P. gas, natural gas, electrical, and safety codes. Your local fuel gas supplier, a local licensed electrician, the local fire department or similar government agencies, or your insurance agent can help you determine code requirements.
Refer to the following:
-- ANSI/NFPA 58, Latest Edition, Standard for Storage and Handling of Liquefied Petroleum Gas and/or
-- ANSI Z223.1/NFPA 54, National Fuel Gas Code
-- ANSI/NFPA 70, National Electrical Code.
3. We cannot anticipate every use which maybe made of our heaters. Check with the local fire safety authority if you have questions about applications.
4. Do not wash the interior of the heater. Use only compressed air, a soft brush or dry cloth to clean the interior of the heater and it’s components.
5. For safety, this heater is equipped with manual reset high limit switches, an air-proving switch and a redundant gas control valve. Never operate the heater with any safety device that has been bypassed. Do not operate this heater unless all of these features are fully functioning.
6. Do not locate fuel gas containers or fuel supply hoses within 20 ft. of the heater’s blower outlet.
7. Do not block air intakes or discharge outlets of the heater. Doing so may cause improper combustion or damage to heater components leading to property damage.
8. The hose assembly shall be visually inspected on a daily basis after heater relocation and when the heater is in use. If it is evident there is excessive abrasion or wear, or if the hose is cut, it must be replaced prior to the heater being put into operation. The hose assembly shall be protected from building materials, and contact with hot surfaces during use. The hose assembly shall be that specified by the manufacturer. See parts list.
9. This heater is equipped with a gas selector valve. The selector valve must be properly positioned for the gas supplied to the heater. Further information on this feature is provided on page 13 of this manual.
10. Check for gas leaks and proper function upon heater installation, when relocating, and after servicing. Refer to leak check instructions within installation section of this manual.
11. This heater should be inspected for proper operation by a qualified service person before each use and at least annually.
12. Always turn off the gas supply to the heater if the heater is not going to be used in the heating of the work space.
13. This heater is equipped with a three-prong (grounding) plug for your protection against shock hazard and must be plugged directly into a properly grounded three-prong receptacle. Failure to use a properly grounded receptacle can result in electrical shock, personal injury, or death.
14. If gas flow is interrupted and flame goes out, do not relight the heater until you are sure that all gas that may have accummulated has cleared away. In any event, do not relight the heater for at least 5 minutes.
14. The heater requires a minimum 500 gallon propane tank for proper gas supply pressure and operation. A larger tank may be required depending upon operating conditions at the site.
15. When the heater is to be stored indoors, the connection between the propane gas supply container and the heater must be disconnected. The container must be removed from the heater and stored in accordance with the Standard for the Staorage and Handling of Liquefied Petrolem Gases, ANSI / NFPA 58.
17. Propane gas supply containers have left handed threads. Always use the appropriate wrench to make a connection to tighten or loosen the pigtail connector’s P.O.L. fitting at the container’s gas supply valve.
6
1. Read all safety precautions and follow L. B. White recommendations when installing this heater. If during the installation or relocating of heater, you suspect that a part is damaged or defective, call a qualified service agency for repair or replacement.
2. Make sure the heater is level and properly positioned before use. Observe and obey all minimum safe distances of the heater to the nearest combustible materials. Safe distances are given on the heater dataplate and on page 4 of this manual.
3. This heater may be installed either indoors or outdoors. For outdoor installations, only the following air distribution devices may be used:
-- 18 in. Dia. x 12 ft. Duct: Part # 22841
-- End Diffuser: Part # 23054
DO NNOT UUSE AANY OOTHER LLENGTH OOF DDUCTWORK OOR FIELD FFABRICATED DDUCT, TTARPS, SSTOVE PPIPE, EETC. ON TTHIS HHEATER.
4. The heater’s gas pressure regulator (with pressure relief valve) must be protected from adverse weather conditions (rain, ice, snow) as well as from building materials (tar, concrete, plaster, etc.) which can affect safe operation and could result in property damage or injury.
5. Heaters used in the vicinity of combustible tarpaulins, canvas, plastics, wind barriers, or similar coverings shall be located at least 10 feet from the coverings. The coverings shall be securely fastened to prevent ignition or upsetting of the heater due to wind action on the covering or other material.
6. Check all connections for gas leaks using approved gas leak detectors. Gas leak testing is performed as follows:
-- Check all pipe connections, hose connections, fittings and adapters upstream of the gas control with approved gas leak detectors.
-- In the event a gas leak is detected, check the components involved for cleanliness and proper application of pipe compound before further tightening.
-- Tighten the gas connections as necessary to stop the leak.
-- After all connections are checked and any leaks are stopped, turn on the main burner.
-- Stand clear while the main burner ignites to prevent injury caused from hidden leaks that could cause flashback.
-- With the main burner in operation, check all connections, hose connections, fittings and joints as well as the gas control valve inlet and outlet connections with approved gas leak detectors.
-- If a leak is detected, check the components involved for cleanliness in the thread areas and proper application of pipe compound before further tightening.
-- Tighten the gas connection as necessary to stop the leak.
-- If necessary, replace the parts or components involved if the leak cannot be stopped.
-- Ensure all gas leaks have been identified and repaired before proceeding.
7. A qualified service agency must check for proper operating gas pressure upon installation of the heater.
8. Light according to instructions on heater or within owner's manual.
9. Make sure the heater has the proper gas regulator for
the application. A regulator must be connected to the gas supply so that gas pressure at the inlet to the gas valve is regulated within the range specified on the dataplate at all times. Contact your gas supplier, or the L.B. White Co., Inc. if you have any questions.
WARNING
Fire aand EExplosion HHazard
CCaann ccaauussee pprrooppeerrttyy ddaammaaggee,, sseevveerree iinnjjuurryy oorr ddeeaatthh
To avoid dangerous accumulation of fuel gas, turn
off gas supply at the heater service valve before starting installation, and perform gas leak test after completion of installation.
Do not force the gas control knob. Use only your
hand to turn the gas control knob. Never use any tools. If the knob will not operate by normal hand pressure the gas control valve should be replaced by a qualified service technician. Force or attempted repair may result in fire or explosion.
7
Installation Instructions
GENERAL
WARNING
Fire aand EExplosion HHazard
Do not use open flame (matches, torches, candles,
etc.) in checking for gas leaks.
Use only approved leak detectors.
Failure to follow this warning can lead to fires or
explosions.
Fires or explosions can lead to property damage,
personal injury or death.
10. This heater is configured for use for L.P. gas vapor withdrawal. Do not use the heater in an L.P. gas liquid withdrawal system or application. If you are in doubt, contact the L.B. White Co., Inc.
11. The heater must be installed so as not to interfere with or obstruct normal exits, emergency exits, doors and walkways.
12. Railing, fencing or suitable substitute materials must be used to keep the heating equipment from any people using and visiting the structure.
13. The heater shall be located so that rain, ice, or snow drainage from the structure does not affect equipment operation. If the heater is mounted outside, it must be mounted above any pooled or standing water. If the unit is to be located on the ground, a surrounding trench is recommended to drain any rain, ice or snow away from the unit.
4. The ground and surrounding terrain must be cleared of any combustible vegetation and other combustible materials when the heater is utilized outside.
15. Eventually, like all electrical/mechanical devices, the thermostat can fail. Thermostat failure may result in an underheating condition. The thermostat should be tested to make sure it turns the heater on and off within a temperature differential of ±3°F.
16. Take time to understand how to operate and maintain the heater by using this Owner’s Manual. Make sure you know how to shut off the gas supply to the building and also to the individual heater. Contact your fuel gas supplier if you have any questions.
17. Any defects found in performing any of the service or maintenance procedures must be eliminated and defective parts replaced immediately. The heater must be retested by properly qualified service personnel before placing the heater back into use.
8
GAS SUPPLY SIZING
The vaporization of propane is affected by several factors: the surface area of the container, the liquid level of propane, temperature surrounding the container, and the relative humidity. All of these factors are specific to a site. Therefore, a degree of experience and judgement is required to select the proper propane supply.
Although experience is the best guide, the following recommendations can be used as a starting point. The table is based on experience in northern climates where cold weather and high humidity are prevalent in the winter. If more or less favorable conditions prevail at a specific site, adjustments can be made on the basis of experience.
RReeccoommmmeennddeedd GGaass SSuuppppllyy::
Propane Supply Tank: Heater(s)/Container: 500 gallon 1 1,000 gallon 2
If more than one gas supply container is used per heater, the containers must be manifolded together to allow vapor withdrawal simultaneously from multiple containers. Manifold system shall be in accordance with NFPA 58.
1. Thread swivel to connector at gas inlet of heater. See Fig. 1. Tighten securely.
2. The hose may be coiled up and hung on the hose hanger, with the regulator stored within the regulator storage bracket.
FIG. 1
CONNECTING HOSE TO HEATER
SWIVEL
PROPANE HHEATERS
1. Open the tank’s cover.
2. Assemble bushing, pigtail connector and regulator as shown. Tighten connections securely. See Fig. 2.
3. Form the connector to ensure the regulator will be supported by the tank, and the tank valve cover will protect the regulator from weather conditions.
FIG. 2
4. Thread connector’s POL fitting counter-clockwise into
the tank valve. Tighten securely. See Fig. 2.
5. Open the tank valve.
6. Check all connections with an approved leak detector. Close the tank cover.
7. When storing or transporting the heater, ensure the connector’s fitting is protected from damage and dirt entry.
NATURAL GGAS HHEATERS
--- The regulator only should be used if the supply pressure to the heater is above the maximum inlet pressure stated on the heater’s dataplate.
---- Connect the regulator to the natural gas supply line. Gas supply pressure to the regulator must be a minimum of 2 PSI.
CONNECTING REGULATOR TO GAS SUPPLY
9
3/4x 1/4 BUSHING
PIGTAIL CONNECTOR
POL
INSIDE STRUCTURE
A. DDuct KKit
Accessory # 22841
1.. Extend the factory assembled duct kit to full length.
2. Mount duct to blower outlet of heater by inserting tabs on duct adapter into vertical and horizontal slots located at top and sides of blower outlet. See Fig. 4. Push down on duct adapter to secure adapter into outlet slots. See below for for typical installation of heater located at exterior.
FIG. 4
OUTSIDE STRUCTURE
(Air Distribution Accessories)
FIG. 3
IS 10 FEET (3.04 M)
FIG. 5
MATERIAL DRAPED OVER DUCT
IS 10 FEET (3.04 M)
Installation of Heater
10
500 GALLON
GAS SUPPLY
(MINIMUM)
MINIMUM SAFE DISTANCE
FROM GAS SUPPLY TO HEATER
DISTANCE FROM HEATER TO SIDE WALL MUST
COMPLY WITH LOCAL CODES, AND BE ACCORDING
TO MANUFACTURER'S REQUIREMENTS
IS 6 FEET
SIDE WALL
MINIMUM SAFE DISTANCE FROM TOP, SIDES, AND BACK OF HEATER TO COMBUSTIBLES IS 1 FOOT
MINIMUM SAFE DISTANCE FROM BLOWER OUTLET TO COMBUSTIBLES IS 6 FEET
SLOTS
DUCT ADAPTER WITH TABS
TA B
500 GALLON
GAS SUPPLY
(MINIMUM)
MINIMUM SAFE DISTANCE FROM GAS SUPPLY TO HEATER IS 6 FEET
DISTANCE FROM HEATER TO SIDE WALL MUST
COMPLY WITH LOCAL CODES, AND BE ACCORDING
TO MANUFACTURER'S REQUIREMENTS
DUCT KIT
DUCT KIT
SIDE WALL
TENT DRAPED OVER DUCT
Loading...