L.B. White 250 User Manual

Propane Gas
Vapor
Withdrawal
Congratulations!
You have purchased the finest convection construction heater available.
Your new L.B. White heater incorporates the benefits from the most experienced manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and welcome any suggestions or comments you may have...call us, toll-free, at (800) 345-7200.
Owner's Manual and Instructions
Norseman Heavy Duty Convection Construction Heaters
ATTENTION ALL USERS
This heater has been tested and evaluated by L.B. White Co., Inc as a direct fired convection construction heater intended for use as the temporary heating of buildings under construction, alteration, or repair.
The hheater sshall bbe uused oonly oon
noncombustible ssurfaces.
If you are considering using this product for any applications other than its intended use, then please contact your fuel gas supplier or the L.B. White Co., Inc.
150-22268-A
MODEL OUTPUT (Btuh) FUEL
341 250,000
WARNING
Fire and Explosion Hazard
Not for home or recreational vehicle use.
Installation of this heater in a home or
recreational vehicle may result in a fire or explosion.
Fire or explosions can cause property
damage or loss of life.
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WARNING
Fire and Explosion Hazard
Keep solid combustibles a safe distance
away from the heater.
Solid combustibles include wood or paper
products, building materials and dust.
Do not use the heater in spaces which
contain or may contain volatile or airborne combustibles.
Volatile or airborne combustibles include
gasoline, solvents, paint thinner, dust particles or unknown chemicals.
Failure to follow these instructions may
result in a fire or explosion.
Fire or explosions can lead to property
damage, personal injury or loss of life.
GENERAL HAZARD WARNING
Failure to comply with the precautions and instructions provided with this heater, can result in:
Death — Serious bodily injury or burns — Property damage or loss from fire or explosion — Asphyxiation due to lack of adequate air supply or carbon monoxide poisoning
Read this Owner’s Manual before installing or using this product.
Only properly-trained service people should repair or install this heater.
Save this Owner’s Manual for future use and reference.
Owner’s Manuals and replacement labels are available at no charge. For assistance, contact
L.B. White at 800-345-7200.
WARNING
Proper gas supply pressure must be provided to the inlet of the heater.
Refer to data plate for proper gas supply pressure.
Gas pressure in excess of the maximum inlet pressure specified at the heater inlet can cause
fires or explosions.
Fires or explosions can lead to serious injury, death, or building damage.
Gas pressure below the minimum inlet pressure specified at the heater inlet may cause
improper combustion.
Improper combustion can lead to asphyxiation or carbon monoxide poisoning and therefore
serious injury or death.
2
This Owner's Manual includes all options and accessories commonly used on this heater.
When calling for technical service assistance, or for other specific information, always have model number, configuration number and serial number available. This information is contained on the dataplate.
This manual will instruct you in the operation and care of your heater. Have your qualified installer review this manual with you so that you fully understand the heater and how it functions.
The gas supply line installation, installation of the heater, and repair and servicing of the heater requires continuing expert training and knowledge of gas heaters and should not be attempted by anyone who is not so qualified. See page 6 for definition of the necessary qualifications.
Contact your local L.B. White distributor or the L.B. White Co., Inc. for assistance, or if you have any questions about the use of the equipment or its application.
The L.B. White Co., Inc. has a policy of continuous product improvement. It reserves the right to change specifications and design without notice.
SECTION
PAGE
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Heater Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installation Instructions
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Burner and Gas Control Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Hose and Regulator Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Start-Up Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Shut-Down Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Cleaning Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Maintenance Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Service Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Gas Pressure Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Troubleshooting Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Heater Component Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Parts Identification
Parts Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Warranty Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Replacement Parts and Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Table of Contents
General Information
3
Maximum Input (BTUH) 250,000
1041 CFM
18 x 13 x 24
TOP TO CEILING 8 ft. SIDES 4 ft.
FUEL CONTAINER
30 34
SPECIFICATIONS
341
Propane
Fuel Type Gas
MMooddeell
Ventilation Air Required to Support Combustion
Net Weight (lbs.) Shipping Weight (lbs.)
Dimensions (Inches) L x W x H
Minimum Safe Distances From Nearest Combustible Materials
Not ffor uuse oon ccombustible mmaterials
Fuel Consumption Per Hour
Inlet Gas Supply Pressure Acceptable at the Inlet of the Pilot Safety Control Valve
MAX.
MIN.
23 PSIG.
4
Heater Specifications
6 ft. (1.83 m)
23 PSIG.
11.6 lbs.
Propane ggas aand nnatural ggas hhave mman-mmade oodorants aadded sspecifically ffor ddetection oof ffuel ggas lleaks. If aa ggas lleak ooccurs, yyou sshould bbe aable tto ssmell tthe ffuel ggas. THAT’S YYOUR SSIGNAL TTO GGO IINTO IIMMEDIATE AACTION!
Do not take any action that could ignite the fuel gas. Do
not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.
Get everyone out of the building and away from the area
immediately.
Close all propane gas tank or cylinder fuel supply
valves, or the main fuel supply valve located at the meter if you use natural gas.
Propane gas is heavier than air and may settle in low
areas. When you have reason to suspect a propane leak, keep out of all low areas.
Use your neighbor’s phone and call your fuel gas
supplier and your fire department. Do not re-enter the building or area.
Stay out of the building and away from the area until
declared safe by the firefighters and your fuel gas
supplier.
FI N ALLY,
let the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair the leak, check for further leakages, and then relight the appliance for you.
Some ppeople ccannot ssmell wwell. SSome ppeople ccannot smell tthe oodor oof tthe mman-mmade cchemical aadded tto propane oor nnatural ggas. YYou mmust ddetermine iif yyou ccan smell tthe oodorant iin tthese ffuel ggases.
Learn to recognize the odor of propane gas and natural
gas. Local propane gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor.
Smoking can decrease your ability to smell. Being
around an odor for a period of time can affect your sensitivity to that particular odor.
The oodorant iin ppropane ggas aand nnatural ggas iis ccolorless and tthe iintensity oof iits oodor ccan ffade uunder ssome circumstances.
If there is an underground leak, the movement of gas
through the soil can filter the odorant.
Propane gas odor may differ in intensity at different
levels. Since propane gas is heavier than air, there may be more odor at lower levels.
Always bbe ssensitive tto tthe sslightest ggas oodor.
If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously.
5
Safety Precautions
FUEL GAS ODOR
ODOR FADING -- NO ODOR DETECTED
ATTENTION -- CRITICAL POINTS TO REMEMBER!
Propane gas has a distinctive odor. Learn to recognize
these odors. (Reference Fuel Gas Odor and Odor Fading sections above.
If you have not been properly trained in repair and service of propane gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane gas fuel system.
Even if you are not properly trained in the service and
repair of the heater, ALWAYS be consciously aware of the odors of propane gas and natural gas.
A periodic sniff test around the heater or at the
heater’s joints; i.e. hose, connections, etc., is a good safety practice under any conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT!
WARNING
Do not use this heater for heating human living
quarters.
Do not use in unventilated areas.
The flow of combustion and ventilation air must not be
obstructed.
Proper ventilation air must be provided to support the
combustion air requirements of the heater being used.
Refer to the specification section of the heater’s
Owner’s Manual, heater dataplate, or contact the L.B. White Company to determine combustion air ventilation requirements of the heater.
Lack of proper ventilation air will lead to improper
combustion.
Improper combustion can lead to carbon monoxide
poisoning leading to serious injury or death. Symptoms of carbon monoxide poisoning can include headaches, dizziness and difficulty in breathing.
Asphyxiation HHazard