POWER AMPLIFIERS
iP 2100
KEY FEATURES: 2 x 425 watts
2 x 700 watts @ 4 2 x 1050 watts @ 2
(Measured just below clip level, with both channels driven)
Compact design:
@
8
Ω Ω
2U high
Intercooler® cooling system with front-to-rear airflow
Multiple positions gain switch
Easily accessible dust filter
Improved low-end power bandwidth
Neutrik Combo jack and Phoenix terminal block input connectors
Bridged mono outputs in one SpeakOn connector
The iP 2100 is a space-saving power amplifier, ideal for use in installations as well as in cost-effective live sound systems.
The Iron Power (iP) family of power amplifiers is the new compact and versatile line of professional power amplifiers with classic toroidal iron transformers. To achieve a compact design, the latest semiconductor tech­nology is utilized. This, together with Lab.gruppen’s proprietary copper cooling system, Inte rcooler®, enhances the 2 ohms capacity.
A new Bi-phase wiring scheme also increases the capacity of the power
supply. This extends the power bandwidth in the low end.
Besides the traditionally superb Lab.gruppen sonic performance, there is a
full line of features to make the iP family functional in all situations from installation to cost-effective live sound systems:
Multiple positions Gain switch
To meet the demands for a flexible gain structure in the system, Lab.gruppen offers a multiple position gain switch. The maximum amplifier gain can be set to all industry standards: 20, 23, 26, 29, 32, 35, 38 and 41 dB.
Versatile input connection
With the Neutrik Combo-jack we offer both the professional XLR-type _standard and the semi-pro 1/4” TRS phono-jacks. For installations the 3-pin Phoenix terminal block may be handier.
Soft Start
Toroidal transformers require a huge amount of start current to build up a magnetic flux when the amplifier is switched on. Therefore Lab.gruppen have included a soft start circuit to minimize the risk of blowing the wall fuse and
to reduce flickering in the lighting.
Sophisticated protection circuitry, combining:
– ALStm short circuit protection; the Adaptive Limiting System permits very high peak currents, but keeps the amplifier within the Safe Operation Area.
– DC protection; protects against infrasonic signals – VHF protection; protects the loudspeakers against strong very high
frequency non-musical signals above the audible range. – Thermal protection; prevents the amplifier from being overheated. The protection indicators on the front panel are switched on, as a warning, before the protection process is initiated. – AC protection; shuts down the power supply if the line voltage is outside the operating voltage. – Clip limiter; prevents severely clipped waveforms from reaching the
loudspeakers, whilst maintaining full peak power.
SPECIFICATIONS iP 2100
MAX OUTPUT POWER
1)
EIA at 1 kHz and 1% THD FTC 20-20kHz @0.1%THD
8 per channel 425 W 400 W 4 per channel 700 W 670 W 2 per channel 1050 W 8 bridged 1400 W 1300 W 4 bridged 2100 W
2)
2)
9802) W
19002) W
Max output voltage
8 ohms load 58 Vrms Peak voltage, no load 92 V
Distortion etc.
THD 20Hz-20kHz and 1W to full power 0,05 % THD @ 1kHZ and –1dB under clip 0,005 % DIM 30 at –3dB under clip 0,005 %
Hum and Noise
<-110 dB
Channel separation @10kHz 70 dB Output impedance 30 m Slew Rate 45 V/µs
Inputs
Gain, selectable [dB] 20, 23, 26, 29,
32, 35, 38, 41 Impedance 20 kohm Common mode rejection 50 dB
Front Panel
Gain controls (2) channel A, B 31 positions detent Protect indicator (2) yellow LEDs 80°C at heatsink or >12kHz at full power or shorted output Clip Indicator (2) red LEDs Fast peak – slow release Signal present indicator (2) green LEDs -40 dB below full output On Indicator (2) green LEDs DC rail voltage for channel A and B
Rear Panel
Input connectors (2) Neutrik Combo XLR type, 3 pin & 1/4” jack Input /Link connector (2) 3-pin Phoenix terminal block Output connectors (2) Neutrik 4-pole Speakon connectors
Switches
Clip limiter A and B On-Off (switchable) Link-switch Ch.A-B
Power 230 V version 115 V version
Operation voltage 130 V-265 V AC 65 V – 135 V AC Minimum start voltage 190 V 95 V AC Full output power at 4ohms 230 V AC 115 V AC Peak inrush current (Soft start limited) 20 A 10 A
Current Draw @ 4ohms&230V
Quiescent power (no load) 0.8 Arms 1.6 Arms 1/8 of full power (-9dB) 5 Arms 10 Arms 1/3 of full power (-5dB) 8 Arms 16 Arms At full power (0 dB) @1 kHz 1% THD 13 Arms 26 Arms
Net Dimensions mm (inch) Shipping Dimensions mm (inch) Net Weight Shipping Weight
483 (19”) W x 88 (3,5”) H x 325 (12.8”) D
560 (22”) W x 180 (7.1”) H x 500 (19.7”) D
18 kg (39.6 lbs)
19.6 kg (43 lbs)
Approvals
CE Emission EN 55 103-1, E3
Immunity EN 55 103-2, E3, with S/N below 1% at normal operation level
Safety EN 60 065, class I
THX iP2100T
1) Specifications measured with 230 VAC 4) Normal operation level 1/8 of full power or –9dB below clip level.
2) Component tolerance dependent
3) Continuous power, one channel driven or peak power both channels driven (Thermal protection may occur at high continuous power)
LAB. GRUPPEN reserve the right to alter functions or specifications without prior notice.
Lab.gruppen AB, Gullregnsvägen 16, S-434 44 Kungsbacka, Sweden.