POWER AMPLIFIERS
iP 2100
KEY FEATURES:
2 x 425 watts
2 x 700 watts @ 4
2 x 1050 watts @ 2
(Measured just below clip level,
with both channels driven)
◆
Compact design:
@
8
Ω
Ω
Ω
2U high
◆
Intercooler® cooling
system with front-to-rear
airflow
◆
Multiple positions gain
switch
◆
Easily accessible dust filter
◆
Improved low-end power
bandwidth
◆
Neutrik Combo jack and
Phoenix terminal block
input connectors
◆
Bridged mono outputs
in one SpeakOn connector
The iP 2100 is a space-saving power amplifier, ideal for use in
installations as well as in cost-effective live sound systems.
The Iron Power (iP) family of power amplifiers is the new compact and
versatile line of professional power amplifiers with classic toroidal iron
transformers. To achieve a compact design, the latest semiconductor technology is utilized. This, together with Lab.gruppen’s proprietary copper
cooling system, Inte rcooler®, enhances the 2 ohms capacity.
A new Bi-phase wiring scheme also increases the capacity of the power
supply. This extends the power bandwidth in the low end.
Besides the traditionally superb Lab.gruppen sonic performance, there is a
full line of features to make the iP family functional in all situations from
installation to cost-effective live sound systems:
Multiple positions Gain switch
To meet the demands for a flexible gain structure in the system, Lab.gruppen
offers a multiple position gain switch. The maximum amplifier gain can be set
to all industry standards: 20, 23, 26, 29, 32, 35, 38 and 41 dB.
Versatile input connection
With the Neutrik Combo-jack we offer both the professional XLR-type
_standard and the semi-pro 1/4” TRS phono-jacks. For installations the 3-pin
Phoenix terminal block may be handier.
Soft Start
Toroidal transformers require a huge amount of start current to build up a
magnetic flux when the amplifier is switched on. Therefore Lab.gruppen have
included a soft start circuit to minimize the risk of blowing the wall fuse and
to reduce flickering in the lighting.
Sophisticated protection circuitry, combining:
– ALStm short circuit protection; the Adaptive Limiting System permits very
high peak currents, but keeps the amplifier within the Safe Operation Area.
– DC protection; protects against infrasonic signals
– VHF protection; protects the loudspeakers against strong very high
frequency non-musical signals above the audible range.
– Thermal protection; prevents the amplifier from being overheated. The
protection indicators on the front panel are switched on, as a warning, before
the protection process is initiated.
– AC protection; shuts down the power supply if the line voltage is outside the
operating voltage.
– Clip limiter; prevents severely clipped waveforms from reaching the
loudspeakers, whilst maintaining full peak power.
SPECIFICATIONS iP 2100
MAX OUTPUT POWER
1)
EIA at 1 kHz and 1% THD FTC 20-20kHz @0.1%THD
8 Ω per channel 425 W 400 W
4 Ω per channel 700 W 670 W
2 Ω per channel 1050 W
8 Ω bridged 1400 W 1300 W
4 Ω bridged 2100 W
2)
2)
9802) W
19002) W
Max output voltage
8 ohms load 58 Vrms
Peak voltage, no load 92 V
Distortion etc.
THD 20Hz-20kHz
and 1W to full power 0,05 %
THD @ 1kHZ and –1dB
under clip 0,005 %
DIM 30 at –3dB under clip 0,005 %
Hum and Noise
<-110 dB
Channel separation @10kHz 70 dB
Output impedance 30 mΩ
Slew Rate 45 V/µs
Inputs
Gain, selectable [dB] 20, 23, 26, 29,
32, 35, 38, 41
Impedance 20 kohm
Common mode rejection 50 dB
Front Panel
Gain controls (2) channel A, B 31 positions detent
Protect indicator (2) yellow LEDs 80°C at heatsink or >12kHz at full power or shorted output
Clip Indicator (2) red LEDs Fast peak – slow release
Signal present indicator (2) green LEDs -40 dB below full output
On Indicator (2) green LEDs DC rail voltage for channel A and B
Rear Panel
Input connectors (2) Neutrik Combo XLR type, 3 pin & 1/4” jack
Input /Link connector (2) 3-pin Phoenix terminal block
Output connectors (2) Neutrik 4-pole Speakon connectors
Switches
Clip limiter A and B On-Off (switchable)
Link-switch Ch.A-B
Power 230 V version 115 V version
Operation voltage 130 V-265 V AC 65 V – 135 V AC
Minimum start voltage 190 V 95 V AC
Full output power at 4ohms 230 V AC 115 V AC
Peak inrush current (Soft start limited) 20 A 10 A
Current Draw @ 4ohms&230V
Quiescent power (no load) 0.8 Arms 1.6 Arms
1/8 of full power (-9dB) 5 Arms 10 Arms
1/3 of full power (-5dB) 8 Arms 16 Arms
At full power (0 dB) @1 kHz 1% THD 13 Arms 26 Arms
Net Dimensions mm (inch)
Shipping Dimensions mm (inch)
Net Weight
Shipping Weight
483 (19”) W x 88 (3,5”) H x 325 (12.8”) D
560 (22”) W x 180 (7.1”) H x 500 (19.7”) D
18 kg (39.6 lbs)
19.6 kg (43 lbs)
Approvals
CE Emission EN 55 103-1, E3
Immunity EN 55 103-2, E3, with S/N below 1% at normal operation level
Safety EN 60 065, class I
THX iP2100T
1) Specifications measured with 230 VAC 4) Normal operation level 1/8 of full power or –9dB below clip level.
2) Component tolerance dependent
3) Continuous power, one channel driven or peak power both channels driven
(Thermal protection may occur at high continuous power)
LAB. GRUPPEN reserve the right to alter functions or specifications without prior notice.
Lab.gruppen AB, Gullregnsvägen 16, S-434 44 Kungsbacka, Sweden.
Tel. +46 300 168 23. Fax +46 300 142 46. e-mail: info@labgruppen.se www.labgruppen.se
4)
2002-03 V1