Konica AFR-12 SERVICE BULLETIN KB0000171

Supplemental Technical Informatiaon
Create Date : 2000/11/02
for Parts Modification Notice
Model Area
AFR-12 Firmware
Symptom
AFR-12 IC7 Firmware version upgrade infomation
Because of the version upgrade the firmware becomes compatible with the new model as well as the current model.
Note: The adjustment procedure for the Document Stop Position is changed as follows when the AFR-12 with the upgraded firmware is mounted to CF910.
"Checking and Adjusting the Document Stop Position" of the "Setting-Up Instructions" describes the following.
After the modification Tolerance : 1 to 3mm in the "c" direction from the right edge of
the Original Scale.
Before the modification Tolerance : 1 to 3mm in the "c" direction from the right edge of
the Original Scale (for Metric Area only) 0 to 1mm in the "d" direction from the right edge of the Original Scale (for Inch Area only)
( KDB No.: KB0000171 )
(The tolerance has become equal in Inch-Area and Metric-Area.)
Parts Modification Notice
MO000745
Related Product Model
CF9001 CF910 CF910L