KONICA 1312 Service Manual ech1

Chapter 1 Specifications
1-1. Outline................................................................... 1-1
1-2. Guaranteed working conditions .........................1-1
1-3. General specifications......................................... 1-2
1-4. Copy specifications ............................................. 1-2
1-5. Consumable parts specifications....................... 1-3
1-6. Option specifications .......................................... 1-3
1-7. Factory installed options specifications ........... 1-3

1-1. Outline

This device is a compact desktop copier, which functions as an electrophotographic copy machine with the mirror zoom enlargement/reduction func­tion, document table fixed type optical section and front loading paper feed method.
1-2. Guaranteed working conditions
1) Standard No. of printed copies per month : 1,000 copies
2) Max. No. of printed copies per month : 5,000 copies
3) Machine service life: 150,000 copies or 5 years
4) Continuous copies : 1 ~ 99 copies
5) Machine operating environment
Temperature:10~30ºC, Humidity: 30~80%RH * With no dew condensation.
6) Storage conditions (storage place)
When storing the packaged part for a long time,
store the unit indoors. As a principle, maintain a constant temperature and constant humidity, and take special care to prevent water, dust and wind. Avoid installing the unit in the places can be exposed to the direct rays or vigorous vibration.
(The storage conditions required in this item also
apply to transportation.)
Main unit storage conditions
Developing unit and drum unit
* When packed:
Store under conditions shown in the table below.
* When unpacked:
Basically, the units should be installed in the main unit. When storing as a single part after opening the package, the normal temperature and humidity conditions given below must be applied. Also, note that it must be shielded from the light.
Temperature:
Normal (9/10 of total storage period)
0~35ºC
Severe (1/10 of total storage period)
High temperature : 35~40ºC Low temperature : -10~0ºC
Tolerable temperature fluctuation (3 min. or
more): 40ºC15ºC
-10ºC25ºC
Humidity:
Normal (9/10 of total storage period)
20~80%
Severe (1/10 of total storage period)
High humidity : 80~95% Low humidity : 5~20%
Temperature:
Normal (9/10 of total storage period)
0~35ºC
Severe (1/10 of total storage period)
High temperature : 35~45ºC Low temperature : -10~0ºC
Tolerable temperature fluctuation (3 min. or
more): 45ºC15ºC
-10ºC25ºC
Humidity:
Normal (9/10 of total storage period)
20~80%
Severe (1/10 of total storage period)
High humidity : 80~95% Low humidity : 5~20%
Atmospheric pressure: 613~1013hPa
Storage period: One year
* Excluding developing unit and drum unit Humidity: With no dew condensation
Atmospheric pressure: 613~1013hPa
Storage period: One year
* Humidity: With no dew condensation
7) Working power supply (Power supply range): 120V± 10%
230V + 10.6% / -14%
(Voltage fluctuation range)
When the device is at the max. load, the voltage
drop must be within 3% in respect to the no-load state.
(Frequency range)
Frequency: 60Hz±2Hz (USA)
8) Installation conditions
1. Avoid high temperature/high humidity places, or low temperature/low humidity places.
2. Avoid installing the units in the place where they can be exposed to the direct rays, or near heat sources such as stoves or heaters.
3. Avoid installing the units in the places having high dust levels.
4. Avoid installing the units in the places where the temperature changes suddenly.
Waveform: Sine wave, distortion
5% or less 50/60Hz±2Hz (EU)