Contemporary design and
quality construction,
providing affordable storage
for bathrooms of any size or
style.
It’s the details that Englefield
cares about - from pioneering
the latest technology, to
innovative design.
1223207-A02-B29/05/2015
Wall Hung
Models
1
Vanity
INSTALLATION INSTRUCTIONSVALENCIATM
BEFORE YOU BEGIN
Please read these instructions carefully to familiarise yourself with the required tools, materials, and
installation sequences. Follow the sections that pertain to your particular installation. This will help you
avoid costly mistakes. In addition to proper installation, read all operating and safety instructions.
Prior to installation, inspect cabinet and top to ensure that no damage has occurred in transit. If damage
has occurred, or a visible defect exists, do not proceed with installation, and advise your supplier
immediately.
Instructions, drawings, and diagrams contained in this manual present information available at the time of printing.
changes without further notice.
Please leave these instructions for the consumer. They contain important information.
ROUGH-IN
Floor Standing Models
600750
465
850
800
Wall Hanging Models
650
600
90012001200
2
ENGLEFIELD
Vanity
INSTALLATION INSTRUCTIONSVALENCIATM
CONSTRUCTION REQUIREMENTS
Floor standing models must be fixed to a nog in the wall. Wall hung models must be fixed to two nogs
in the wall. The nog size should be 50 x 75mm.
Floor standing modelsWall Hung models
50mm from top of
50mm from top of
50
cabinet to centre
of nog.
Positioning of the nog near
vertical centre is recommended
however exact position will
depend on plumbing etc.
50
cabinet to centre
of nog.
A height of 800 to 850mm
800-850
from the floor to the top of the
vanity top is recommended for
the wall hung vanity.
TOOLS AND MATERIALS REQUIRED - (Not Supplied)
TOOLSMATERIALS - Not supplied & must be purchased separately
To suit pipework
To suit screws
INSTALLATION
1 Drawer removal
(a) Open the drawer and carefully lift up on the
end of the drawer to release it from the runner
locator pins. It may be necessary to gently pry
the runner away from the drawer.
10g x 75mm
Screws (Refer step 3)
20mm
Fixing washers
(b) The drawer is now only held by the runner
hooks at the back and can be pulled out in
the direction shown.
Runner hook
Locator pin
3
ENGLEFIELD
Vanity
INSTALLATION INSTRUCTIONSVALENCIATM
2 Changing drawer trims (Optional)
NOTE: This section is only applicable if you have
purchased alternate trims for your vanity cabinet.
(a) After both drawers have been removed (refer to
section 1), unscrew the 2 trim fixing screws from
each angle bracket located behind either side of
each trim.
NOTE: Keep the screws for use later on.
Upper trim
Angle
brackets
Lower trim
(b) Unscrew 3-4 screws from underneath each
trim and remove the trims from the cabinet.
NOTE: Keep the screws for use later on.
Angle
brackets
(c) Having drilled the required holes fit the cabinet
into position over the pipework.
NOTE: Before fastening the cabinet make sure that
the it is sitting level and square and if installing a
floor mounted model ensure that the selected
location is free of bumps and protrusions.
NOTE: Screws should be positioned in an evenly
spaced pattern as shown below.
Floor standing models
50
Screw positions
for 600mm floor
mount vanity shown
50
(c) Fix the new trims in place using the screws
that were removed from the original trims.
3 Water supply and waste pipe holes
(a) Measure and mark the centres for water
supply and waste pipes on the back of the
cabinet.
Alternate drain
position for floor
standing models
(b) With a suitably sized hole saw drill the holes
for the water supply and waste.
Wall Hung models
50
Screw positions
for 600mm wall
mount vanity shown
50
4 Fixing the vanity to the wall
(a) Fix the cabinet to the wall using screws (min
10g x 75mm) and *20mm washers. Screw
through the back rail or wall so that they screw
into the nog/s in the wall behind.
*Washers must be used to spread the load.
Number of screws required
SizeFloor Mount
6003
7504
9004
12005
Wall Mount
5
7
7
9
4
ENGLEFIELD
Vanity
INSTALLATION INSTRUCTIONSVALENCIATM
5 Vanity top
(a) Unpack the top and check for any damage that
might have occured in transit. Check and
confirm the fit of your selected tapware.
(b) Apply a continuous bead of silicone (not
supplied) to the top edge of the cabinet sides
and back. Ensure there are no gaps in the
sealant bead. This will ensure the top stays
securely fitted to the cabinet and no water
spillage will find its way into the cabinet.
No silicone on
front edge
7 Drawer re-installation
(a) To re-install the drawers, extend the runners.
Place a drawer onto the runners and slide back
so that the runner hooks insert into the rear of
the drawer.
(b) Make sure the locator pins line up with the
holes in the bottom of the drawer and press the
drawer down so that the pins slot into place.
Runner hook
(c) Place the vanity top onto the cabinet ensuring
that the back is flush against the wall and
there is an even overhang on either side of the
cabinet.
==
(d) Wipe off any excess sealant.
6 Waste and tapware
Locator pin
8 Sealing
(a) All edges MUST be sealed with an approved
Silicone Sealant.
- Between cabinet and floor
- Bewteen cabinet and wall
- Between upstand and wall
(a) Fit the waste and tapware. Connect the water
supply to the taps and waste pipe to the waste
outlet.
(b) Run hot and cold water and check for leaks.
When satisfied with the results move on to the
next section.
INSTALLATION COMPLETE
5
ENGLEFIELD
Vanity
INSTALLATION INSTRUCTIONSVALENCIATM
CLEANING AND MAINTENANCE INSTRUCTIONS
For cleaning instructions, please refer to the Owner’s Information Leaflet.
CONTACT AND WARRANTY INFORMATION
- Please refer to the Owner’s Information Leaflet for contact information.
- Please visit our website for warranty and other information.
NEW ZEALAND
KOHLER NZ LTD
www.englefield.co.nz
AUSTRALIA
KOHLER CO.
www.englefield.com
6
ENGLEFIELD
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.