KOHLER CHINA INVESTMENT CO., LTDNO.158, JIANG CHANG SAN ROAD,
1367689-T01-A
JING'AN DISTRICT, SHANGHAI, PRCPOST CODE: 200436
()158200436
Page 2
BEFORE YOU BEGIN
Please read these instructions carefully to familiarize
!
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operation and safety instructions.
All information in these instructions is based upon the
!
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
These instructions contain important care, cleaning, and
!
warranty information -
consumer
This product complies with GB 4706.1-2005, GB4706.23-
!
.
please leave instructions for the
2007, GB 4706.27-2008, GB7000.1, GB7000.202 and
GB/T17743.
WARNING: Risk of electrical shock.
A licensed
electrician should make all electrical connections.
WARNING: Risk of electrical shock.
Connect only to
a circuit protected by a typical two-pole circuit breaker.
WARNING: Risk of electrical shock.
Disconnect
power before servicing.
!
,
!
!
!
GB 4706.1-2005GB4706.23-2007GB
4706.27-2008 GB7000.1 GB7000.202 GB/T17743
-
RECOMMENDED TOOLS AND MATERIALSRECOMMENDED TOOLS AND MATERIALS
!
Tape measure
!
Level
!
Screw driver
!
Connection wire
!
Wire cutter
!
Insulation tape
!
Bushing
!
Percussion Drill
!
Pen Knife
!
Wrench
ROUGHING-IN
Reference Value
Hot Air Outlet
300
300
294
272
!
!
!
!
!
!
!
!
!
!
289
Ventilation Outlet
Unit: mm
:
268
Junction Box Cover
1367689-T01-A
162
180
Kohler reserves the right to change marked dimensions without prior notice.
THE RATE OF THE POWER SWITCH
MUST NOT BE LOWER THAN 250V 16A
250V 16A
K-21466T-0
220V
50Hz
ALL-POLE SWITCH (OPTIONAL)
THE RATE OF THE POWER SWITCH
MUST NOT BE LOWER THAN 250V 16A
250V 16A
YELLOW/GREEN
/
YELLOW/GREEN
/
OVER CURRENT FUSE
THERMAL FUSE
HEATER 11
HEATER 22
LED POWER
LED
TEMPERATURE
AND HUMIDITY
SENSOR MODULE
ANION GENERATOR
OVER CURRENT FUSE
THERMAL FUSE
HEATER 11
HEATER 22
LED POWER
LED
THERMOSTAT
BROWN
BROWN
YELLOW
ORANGE
THERMOSTAT
BROWN
BROWN
RED
BLUE
BLUE
GRAY
WHITE
GRAY
WHITE
BLACK
PINK
RED
BLACK
RED
RED
BLUE
BLUE
GRAY
WHITE
GRAY
WHITE
BLACK
P1
P2
P3
P4
P5
CN4
CN14
CN11
CN12
CN5
P1
P2
P3
P4
P5
CN4
CN14
CN11
CN12
CN5
MAIN CONTROL CIRCUIT BOARD
MAIN CONTROL CIRCUIT BOARD
CN3
CN8
CN6
CN7
CN3
CN8
CN6
CN7
RED
CAPACITOR
YELLOW
BLUE
WHITE
BLUE
PINK
YELLOW
ORANGE
RED
BLUE
PINK
YELLOW
ORANGE
RED
RED
CAPACITOR
YELLOW
BLUE
WHITE
BLUE
PINK
YELLOW
ORANGE
RED
BLUE
PINK
YELLOW
ORANGE
RED
MOTOR
STEPPER MOTOR
STEPPER MOTOR
MOTOR
STEPPER MOTOR
STEPPER MOTOR
1367689-T01-A
K-21464T-X-0
220V
50Hz
ALL-POLE SWITCH (OPTIONAL)
THE RATE OF THE POWER SWITCH
MUST NOT BE LOWER THAN 250V 16A
250V 16A
YELLOW/GREEN
/
OVER CURRENT FUSE
THERMAL FUSE
HEATER 11
HEATER 22
LED POWER
LED
TEMPERATURE
AND HUMIDITY
SENSOR MODULE
ANION GENERATOR
THERMOSTAT
BROWN
BROWN
YELLOW
ORANGE
-3-
RED
BLUE
BLUE
GRAY
WHITE
GRAY
WHITE
BLACK
PINK
RED
BLACK
RED
P1
P2
P3
P4
P5
CN4
CN14
CN11
CN12
CN5
MAIN CONTROL CIRCUIT BOARD
CN3
CN8
CN6
CN7
RED
CAPACITOR
YELLOW
BLUE
WHITE
BLUE
PINK
YELLOW
ORANGE
RED
BLUE
PINK
YELLOW
ORANGE
RED
WHITE
WHITE
WHITE
WHITE
RED
MOTOR
STEPPER MOTOR
STEPPER MOTOR
CLOUD
COMMUNICATION
ASSEMBLY
Page 5
Conductor
Earth
8
8
10
13
Make sure the power cord installed firmly,
otherwise it may catch fire.
Power Cord
Terminal
Conductor
Insulation
(Unit: mm)
(: )
+
+
+
+
+
8
+
There's no risk of damage to the insulation of power cord.
Copper cord must be inserted into the pillar terminal hole, and make
sure all the cords under the terminal are inserted into the pillar
terminal completely.
Suggest using a power cord which with specification 60227 IEC 53
Model's powercord Specified in GB/T 5023.5 and with cross section
of 3X1.0mm .
2
GB/T 5023.560227 IEC 53,
3X1.0mm
2
PREPARATIONS BEFORE INSTALLATION
A. Preparation before the installationA.
WARNING
,
1. Open the hole of outlet window
Make sure that the outlet window s position (it should be
lower than the outlet of the bathroom heater to prevent the
water come back to the bathroom heater from the outlet
window), and open a round hole on the wall.
2. Outlet window installation
Fix the air exhaust pipe to the outlet window on the wall
with the clamp as the preparation of bathroom heater
installation. Seal the pipe and the outlet window with
foaming agent.
The installed product must be 200mm or above away from
curtains or other combustible materials.
!
The distance between the ceiling where the product is
mounted and the roof shall be 200mm or above.
!
Ensure that the gap between the product edge and the
wall is 300mm or above.
The power cord to the product shall have enough length
!
for the installation.
The distance between the product and the air outlet
!
window shall be 2000mm or lower.
Cut the screw rod(M6) to suit the distance between the
!
ceiling and the roof.
Air Exhaust Pipe
Wall
!
!
!
!
!
!
Air Outlet Window
Cover
*2
200mm
2000mm
Lower than 2000mm
2000
6 Plastic
Expansion Pipe
6*2
200mm
300mm
(M6)
300mm above
300
1. Connecting the power cord
(1) Pass the power cord through the ceiling.
1367689-T01-A
300mm above
300
1.
(1)
Power cord
Decorated Plate
-6-
Page 8
2. Fix the power cord to the bathroom heater
(1) Remove the screw on the wiring cover plate.
(2) Open the wiring cover plate.
(3) Lift the terminal protection cover.
(4) Loosen the screw fixing the power cord clip.
(5) Loosen the screw on the wiring terminal, insert the
power cord (not supplied) connected to the indoor fixed
line into the wiring terminal, tighten the wring terminal
screw.
(6) Fix the power cord with power cord clips. (The power
cord clip must pin the insulation sheath of power cord.)
(7) Use the screw removed in step (1) to fix the wiring
cover plate again.
2.
(1)
(2)
(3)
(4)
(5)(
)
(6)(
)
(7)(1)
N
L
Wiring Terminal
Power cord
3. Installing the Main Body Method 1 integrated ceiling.
integrated ceiling should be 300*300, 300*450, 300*600
(1) Disassembly the decorated plate around the position of
the product installation.
Disassembly 6 pieces
6
300mm*300mm integrated ceiling
300mm*300mm
(2) Bend the installation template to 90 at the bending line.
°(2)90
300mm*450mm integrated ceiling
300mm*450mm
Push the template to the location of fixed hole A in the
ceiling as the diagram shows.
Install Template
Bending Line
3.
(1)
Disassembly 6 pieces
6
Install Template
300*300 300*450 300*600
()
Disassembly 3 pieces
3
300mm*600mm integrated ceiling
300mm*600mm
A()
Install Template
Install Template
1367689-T01-A
Fixed Hole A
A
Cement Board
150
288
300mm*300mm integrated ceiling
300mm*300mm
-7-
Page 9
(3) Fix the suspender on the right position of the cement
board, use the install template to adjust the M6 nut on
the suspender.
(3)
M6
M6 Butterfly Nut
Suspender
Cement Board
M6
6 Washer
6
6 Spring Washer
6
M6 Nut
M6
(4) Fix the suspension bracket on the suspender by 8
BTP4*8 screw.
(4)8 BTP4*8
BTP4*8 Triangular Self Tapping Screw
BTP4*8(4 )
Ceiling Surface
M6 Nut
M6
Install template datum line
(5) Fix the product on the M6 suspender by the suspension
bracket.
(5)M6
M6 Butterfly Nut
M6
6 Washer
6
6 Spring Washer
6
M6 Nut
M6
1367689-T01-A
-8-
Page 10
(6) Install the air exhaust pipe
1) Fix the air exhaust pipe on the ventilation outlet assy.
by the clamp. The pipeline connected to outside of
the room must be slanted to prevent rain or
condensed water from flowing backwards.
(6)
1)
Ventilation Outlet Assy.
BTP4*8 Triangular
Self Tapping Screw
BTP4*8(1 )
(7) Install the decorated plate and adjust the nut on the
suspender to keep them on the same horizontal surface.
Lock the nut after the adjustment.
Ventilation Outlet
Clamp
Air Exhaust Pipe
Indoors
Outdoors
Slant Taper
(7)M6M6
Base
Decorated Plate
1
()
~
100150
(8) Install the remaining decorated plate (finish the product
installation)
1367689-T01-A
(8)()
300mm*300mm integrated ceiling
300mm*300mm
-9-
Page 11
4. Installing the Main Body Method 2 Ceiling mounting has
not been installed.
(1) Positioning and installation of the suspenders
1) Put the installation template to the position of fixed
hole A and B on where the bathroom heater is going
to be installed.
Cement Board
Install Template
Fixed Hole A
A
4.
(1)
1)
AB
Fixed Hole B
B
2) According to the marked positions of screw rods, fix
the rods on the ceiling.
Cement Board
Suspender
(2) Fix the ventilation outlet assy. to the main body using
the BTP4*8 self-tapping screw.
(3) Fix the suspension bracket to the main body using the 8
BTP4*8 self-tapping screws.
2)
(2)1 BTP4*8
BTP4*8 Self Tapping Screw
BTP4*8(1 )
(3)8 BTP4*8
(4) Fix the product on the M6 suspender by the suspension
bracket. Lock the nut after the installation.
1367689-T01-A
BTP4*8 Triangular
Self Tapping Screw
BTP4*8(4 )
(4)
M6 Butterfly Nut
M6
6 Spring Washer
6
6 Washer
6
M6 Nut
M6
-10-
Page 12
(5) Install the air exhaust pipe
1) Fix the air exhaust pipe on the ventilation outlet assy.
by the clamp. The pipeline connected to outside of
the room must be slanted to prevent rain or
condensed water from flowing backwards.
Ventilation Outlet
Clamp
(5)
1)
Air Exhaust Pipe
Indoors
Outdoors
INSTALLATION OF REMOTE CONTROLLER HOLDERINSTALLATION OF REMOTE CONTROLLER HOLDER
NOTE:
(such as wood board, density board and etc.), suitable fixing
methods shall be adopted.
NOTE:
easily splashed by water.
Choose a mounting location for the remote holder.
Drilling two holes with depth larger than 45mm on the wall by
drill with a diameter of 6mm in accordance with the position of
screw holes on the remote control holder. Installing the
expansion tube into the holes.
Placing the installation holder on the fixing hole.
Fixing the holder with screws and install it.
Installing the screw covers on the screws.
Placing the remote controller on the holder.
If the wall for installation is made of special material
The place to install the remote controller shall not be
Base
45mm
Slant Taper
1
()
~
100150
6mm
Remote Control
INSTALLATION OF COIN BATTERYINSTALLATION OF COIN BATTERY
Please follow the installation diagram.
Head
Bottom
Bottom
1367689-T01-A
Head
Cover
-11-
Screw
Expansion Tube
Head
Coin Battery (CR2430)
Bottom
Page 13
USER'S GUIDE
A. Before Using
Before using the remote control, please take off the
!
battery insulating strip.
Before using the remote controller, please wait for 5
!
seconds after the power source is connected.
B. Paring
!
Please press "Light" and "Light Off" together within 3
minutes after connecting to power source. If "Beep, Beep,
Beep" can be heard and the LED light is on, it means
paring is successful.
A.
!
!
Battery Insulating Strip
B.
!
3
5
LED
C. Button FunctionC.
DOWN : Timer Down/Temperature Down.
UP : Timer Up/Temperature ON.
HEATER : Turn on the heater mode
FAN : Turn on the fan mode
DRY : Turn on the hot /cool dry clothes mode
VENTILATION : Turn on the ventilation/long time vent mode
AIR FLOW : Set the air flow swing or fixed
AIR-CARE : Turn on the air-care mode
LIGHT : Lighting on and off/chang the light color
Light Off :
STOP : Stop certain function
Turning off the light.
/
/
24
/
()
1367689-T01-A
-12-
Page 14
D. Display InformationD.
Current
Set
Hour
Minute
Celsius
Humidity
HEATER
FAN
HOT DRY
COOL DRY
24H VENTILATION24
VENTILATION
AIR-CARE
AIR FLOW FIXED
SWING MODE
E. Activated mode
During the standby mode, press any button to the
!
activated mode
, K-21464T-0 and K-21464T-X-0 will
display room temperature and humidity, K-21466T-0 will
display "00:00". Display will be turned off if not any further
action is taken with 10 seconds.
During the working mode, display the room temperature
!
and humidity. Display will be turned off after the
countdown finish.
Press the function button, the "beep will be heard.
!
"
F. Time setting
!
Setting time could be changed during the "HEATER",
"
"FAN , "DRY", "VENTILATION" and "AIR-CARE" mode.
!
Setting time will be changed back to the default after each
use.
!
"HEATER": the default time is 3 hours, minimum time is
30 minutes, and maximum time is 6 hours.
!
If press "Stop" when the heater is working, the heater will
continue to work for next 30 seconds to protect the
machine and the remote control will show the count down.
!
"FAN": the default time is 3 hours, minimum time is 30
minutes, and maximum time is 6 hours.
!
!
!
!
!
"
"DRY : the default time is 3 hours, minimum time is 30
minutes, and maximum time is 6 hours.
If press "Stop" when hot dry is working, the heater will
continue to work for next 30 seconds to protect the
machine and the remote control will show the count down.
"VENTILATION": the default time is 3 hours, minimum
time is 30 minutes, and maximum time is 6 hours.
"AIR-CARE": the default time is 3 hours, minimum time is
30 minutes, and maximum time is 6 hours.
"24H VENTILATION": the default time is 6 hours, the
setting time cannot be changed.
E.
!
K-21464T-0 K-21464T-X-0
K-21466T-0"00:00" 10
!
!
F.
!
!
!
6
!
!
6
!
!
!
!
!
/330
6
30
6
6
2424
+-
330
30
330
330
330
1367689-T01-A
-13-
Page 15
G. Temperature Setting
Press "Heater" after the remote control is activated, and
!
the screen will show temperature setting. Pressing "+" or
"-" can increase or decrease the heating temperature.
Pressing "Heater" again within 10 seconds will turn to time
set.
"Heater": Default temperature is 40 C, maximum
!
temperature is 40 C while the minimum is 30 C.
°°
°
TROUBLESHOOTING
G.
!
!
30 C
°
40 C+-
°
10
40 C40 C
°°
ProblemDiagnosis
Bathroom Heater does not
work.
The remote controller
does not display.
The remote controller
does not work.
A "Beep" alarm is on when
turn on "Heater",
"Ventilation", "Air-Care"
and "Cloth Dry".
A. A power failure occurred.
B. The power cord is disconnected.
C. Circuit breaker is in the "Off" position.
A. The battery has been used up.
B. The polarity of battery was installed inversely.
C. No wake-up.
A. No pairing with the bathroom heater.
B. The remote controller is used in an
inappropriate position or angle.
C. Low battery.
A. Dust filter need be cleaned.
Solution
A. Wait until the power is restored.
B. Connect the power cord into the junction box
of bathroom heater.
C. Turn on the power at the breaker.
A. Please replace the battery.
B. Please install the battery correctly.
C. Press any key to wake-up.
A. Make the pairing.
B. Change the using position or angle to make
the controller towards the bathroom heater.
C. Change the battery.
A. Clean the filter or press the "+" for 2 seconds
in the Activated Mode.
A.
B.
C.
A.
B.
C.
A.
B.
C.
A.
A.
B.
C.
A.
B.
C.
A.
B.
C.
A.+2
1367689-T01-A
-14-
Page 16
CARE & CLEAN
1. Shut off the power source, and turn around the wind swing
assembly manually.
2. Hold the two ends of the filter, and take it off by pulling the
assembly.
Filter
Holding Here
3. After the filter is cleaned, put it back to the wind swing
assembly, on which there is an arrow symbol. Please make
sure that the printed point is well matched with the mark to
install the filter correctly. Finally, turn on the power and the
wind swing assembly will restore automatically in 5
seconds.
Filter Printed Point
1.
Wind Swing Assy.
2.
Filter
3.
(
)5
Filter Mark
IMPORTANT CONSUMER INFORMATION
1. When AC power unit is connected to 220V AC power
supply, corresponding protective measures should be
taken.
2. Please confirm no water penetration at the connection area
of AC wire, and the connection area is not easy to be
affected by damp.
3. The head AC power supply must be protected with
appropriate fuse.
4. Please confirm the AC power supply should be shut off
before maintaining the products with AC power related.
5. All electrical connection must be compliance with related
regulation and codes.
6. All installation staff should be well familiar with installation
instruction.
Notice: Troubleshooting needs to be done by
professional of KOHLER CHINA. Users are not suggested
to do this without help. Please remember that the
checking and repairs done by users themselves could
easily cause damage to the machine or cause physical
harm to the person.
1.220V
2.
3.
4.
5.
6.
1367689-T01-A
-15-
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.