Kohler S300, K-21464T-X-0, K-21464T-0, K-21466T-0, K-24619T-0 owner's Manual

...
Page 1
Installation and Homeowners Guide
Veil Bathroom Heater S300
S300
K-21464T-0
(Aircare)
K-21464T-X-0(Cloud)
K-21466T-0
KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD,
1367689-T01-A
JING'AN DISTRICT, SHANGHAI, PRC POST CODE: 200436
Page 2
BEFORE YOU BEGIN
Please read these instructions carefully to familiarize
!
yourself with the required tools, materials, and installation sequences. Follow the sections that pertain to your particular installation. This will help you avoid costly mistakes. In addition to proper installation, read all operation and safety instructions. All information in these instructions is based upon the
!
latest product information available at the time of publication. Kohler China reserves the right to make changes in product characteristics, packaging, or availability at any time without notice. These instructions contain important care, cleaning, and
!
warranty information -
consumer
This product complies with GB 4706.1-2005, GB4706.23-
!
.
please leave instructions for the
2007, GB 4706.27-2008, GB7000.1, GB7000.202 and GB/T17743.
WARNING: Risk of electrical shock.
A licensed
electrician should make all electrical connections.
WARNING: Risk of electrical shock.
Connect only to
a circuit protected by a typical two-pole circuit breaker.
WARNING: Risk of electrical shock.
Disconnect
power before servicing.
!
,
!
!
!
GB 4706.1-2005 GB4706.23-2007 GB
4706.27-2008 GB7000.1 GB7000.202 GB/T17743
-
RECOMMENDED TOOLS AND MATERIALSRECOMMENDED TOOLS AND MATERIALS
!
Tape measure
!
Level
!
Screw driver
!
Connection wire
!
Wire cutter
!
Insulation tape
!
Bushing
!
Percussion Drill
!
Pen Knife
!
Wrench
ROUGHING-IN
Reference Value
Hot Air Outlet
300
300
294 272
!
!
!
!
!
!
!
!
!
!
289
Ventilation Outlet
Unit: mm
:
268
Junction Box Cover
1367689-T01-A
162
180
Kohler reserves the right to change marked dimensions without prior notice.
-1-
©©Copyright Kohler China Investment Co., Ltd. 2018
2018
Page 3
SPECIFICATIONS
Model
Voltage/Frequency
Rated Input Power
Heater Power
Fan Power
Dry Clothing Power
Ventilation Power
Air-care Power
Lighting Power
Ventilation Volume
Ventilation Noise
K-21464T-0/K-21464T-X-0/ K-21466T-0
220V~/50Hz
2150W 2150W
2137W 2137W
35W 35W
2137W(Hot)/35W(Cool) 2137W( )/35W( )
38W 38W
36W(K-21464T-0/K-21464T-X-0 Only)
13W 2 (72pcs 0.2W) 13W 2 (72 0.2W)
3
3.0m /min
44dB 44dB
IPX2 (Bathroom Heater) IPX2 ( )
Ingress Protection
IPX4 (Remote Control)
IP20 (LED)
SIMPLIFIED DIAGRAM OF THE UNIT
K-21464T-0/K-21464T-X-0/ K-21466T-0
/
220V~/50Hz
36W( K-21464T-0/K-21464T-X-0)
3
m /min
3.0
IPX4 ( )
IP20 (LED )
Expansion Pipe
M6 Screw Rod M6
Air Outlet Window
Clamp
Air Exhaust Pipe
Ventilation Outlet Assy.
BTP4*8 Triangle Self-tapping Screws BTP4*8
M6 Nut M6
M6 Butterfly Nut M6
Hanger
BTP4*8 Triangle Self-tapping Screws BTP4*8
Keel
6 Washer
6 6 Cushion 6
1367689-T01-A
-2-
Page 4
WIRING DIAGRAM
K-21464T-0
220V 50Hz
ALL-POLE SWITCH (OPTIONAL)
THE RATE OF THE POWER SWITCH MUST NOT BE LOWER THAN 250V 16A
250V 16A
K-21466T-0
220V 50Hz
ALL-POLE SWITCH (OPTIONAL)
THE RATE OF THE POWER SWITCH MUST NOT BE LOWER THAN 250V 16A
250V 16A
YELLOW/GREEN
/
YELLOW/GREEN
/
OVER CURRENT FUSE
THERMAL FUSE
HEATER 1 1
HEATER 2 2
LED POWER
LED
TEMPERATURE
AND HUMIDITY
SENSOR MODULE
ANION GENERATOR
OVER CURRENT FUSE
THERMAL FUSE
HEATER 1 1
HEATER 2 2
LED POWER
LED
THERMOSTAT
BROWN
BROWN
YELLOW
ORANGE
THERMOSTAT
BROWN
BROWN
RED
BLUE
BLUE
GRAY
WHITE
GRAY
WHITE BLACK
PINK
RED
BLACK
RED
RED
BLUE
BLUE
GRAY
WHITE
GRAY
WHITE BLACK
P1
P2
P3
P4
P5
CN4
CN14
CN11
CN12
CN5
P1
P2
P3
P4
P5
CN4
CN14
CN11
CN12
CN5
MAIN CONTROL CIRCUIT BOARD
MAIN CONTROL CIRCUIT BOARD
CN3
CN8
CN6
CN7
CN3
CN8
CN6
CN7
RED
CAPACITOR
YELLOW
BLUE
WHITE
BLUE
PINK
YELLOW
ORANGE
RED
BLUE
PINK
YELLOW
ORANGE
RED
RED
CAPACITOR
YELLOW
BLUE
WHITE
BLUE
PINK
YELLOW
ORANGE
RED
BLUE
PINK
YELLOW
ORANGE
RED
MOTOR
STEPPER MOTOR
STEPPER MOTOR
MOTOR
STEPPER MOTOR
STEPPER MOTOR
1367689-T01-A
K-21464T-X-0
220V 50Hz
ALL-POLE SWITCH (OPTIONAL)
THE RATE OF THE POWER SWITCH MUST NOT BE LOWER THAN 250V 16A
250V 16A
YELLOW/GREEN
/
OVER CURRENT FUSE
THERMAL FUSE
HEATER 1 1
HEATER 2 2
LED POWER
LED
TEMPERATURE
AND HUMIDITY
SENSOR MODULE
ANION GENERATOR
THERMOSTAT
BROWN
BROWN
YELLOW
ORANGE
-3-
RED
BLUE
BLUE
GRAY
WHITE
GRAY
WHITE BLACK
PINK
RED
BLACK
RED
P1
P2
P3
P4
P5
CN4
CN14
CN11
CN12
CN5
MAIN CONTROL CIRCUIT BOARD
CN3
CN8
CN6
CN7
RED
CAPACITOR
YELLOW
BLUE
WHITE
BLUE
PINK
YELLOW
ORANGE
RED
BLUE
PINK
YELLOW
ORANGE
RED
WHITE WHITE WHITE WHITE
RED
MOTOR
STEPPER MOTOR
STEPPER MOTOR
CLOUD
COMMUNICATION
ASSEMBLY
Page 5
Conductor
Earth
8
8
10
13
Make sure the power cord installed firmly, otherwise it may catch fire.
Power Cord
Terminal
Conductor
Insulation
(Unit: mm) (: )
+
+
+
+
+
8
+
There's no risk of damage to the insulation of power cord. Copper cord must be inserted into the pillar terminal hole, and make sure all the cords under the terminal are inserted into the pillar terminal completely. Suggest using a power cord which with specification 60227 IEC 53 Model's powercord Specified in GB/T 5023.5 and with cross section of 3X1.0mm .
2
GB/T 5023.5 60227 IEC 53 ,
3X1.0mm
2
PREPARATIONS BEFORE INSTALLATION
A. Preparation before the installation A.
WARNING
,
1. Open the hole of outlet window Make sure that the outlet window s position (it should be lower than the outlet of the bathroom heater to prevent the water come back to the bathroom heater from the outlet window), and open a round hole on the wall.
2. Outlet window installation Fix the air exhaust pipe to the outlet window on the wall with the clamp as the preparation of bathroom heater installation. Seal the pipe and the outlet window with foaming agent.
Ceiling
The situation of outlet window on the
wall outside.
Outlet Window
1.
2.
Air Exhaust Pipe
(
Wall
Inside
The situation of outlet window on the
Outside
Outlet Window
wall inside.
)
1367689-T01-A
Hole on the Wall
120mm
120mm
-4-
Outlet Window
Hole on the Wall
110mm
110mm
Page 6
B. Take out the bathroom from package. B.
Bathromm Heater
C. Packing List C.
1367446
100 Air Outlet Window 100
1367447
100 Air Exhasut Pipe 100
1285549 Clamp
*2
1367445 Ventilation Outlet Assy.
Note: Initial Length: 140mm
Stretch Length: 2000mm
140mm 2000mm
1322379 Fixed Column Assy. (2pcs)
(2 )
Expansion Pipe
M6 Screw Rod M6
305mm
1285553 Lock Assy. /
M6 Butterfly Nut M6
6 Washer 6
6Spring Washer 6
M6 Nut M6
Triangular Self-tapping Screw BTP4*8
1367691 Heater Accessories Assy.
Hanger
Triangular Self-tapping Screw BTP4*8
1367689-T01-A
1367443 Remote Control Assy.
Remote Control
(Only K-21466T-0 ( K-21466T-0)
-5-
Remote Control Base Assy.
Base
)
M4*25 Screw
*2
Cover
*2
6 Plastic
Expansion Pipe
6*2
Page 7
1367690 Installation Template
S300
1367442 Remote Control Assy.
Remote Control
(Only K-21464T-0/ K-21464T-X-0 ( K-21464T-0/ K-21464T-X-0)
)
Remote Control Base Assy.
Base
M4*25 Screw
*2
INSTALLATION
Caution before installation:
!
The installed product must be 200mm or above away from curtains or other combustible materials.
!
The distance between the ceiling where the product is mounted and the roof shall be 200mm or above.
!
Ensure that the gap between the product edge and the wall is 300mm or above. The power cord to the product shall have enough length
!
for the installation. The distance between the product and the air outlet
!
window shall be 2000mm or lower. Cut the screw rod(M6) to suit the distance between the
!
ceiling and the roof.
Air Exhaust Pipe
Wall
!
!
!
!
!
!
Air Outlet Window
Cover
*2
200mm
2000mm
Lower than 2000mm
2000
6 Plastic
Expansion Pipe
6*2
200mm
300mm
(M6)
300mm above 300
1. Connecting the power cord
(1) Pass the power cord through the ceiling.
1367689-T01-A
300mm above 300
1.
(1)
Power cord
Decorated Plate
-6-
Page 8
2. Fix the power cord to the bathroom heater (1) Remove the screw on the wiring cover plate. (2) Open the wiring cover plate. (3) Lift the terminal protection cover. (4) Loosen the screw fixing the power cord clip. (5) Loosen the screw on the wiring terminal, insert the
power cord (not supplied) connected to the indoor fixed line into the wiring terminal, tighten the wring terminal screw.
(6) Fix the power cord with power cord clips. (The power
cord clip must pin the insulation sheath of power cord.)
(7) Use the screw removed in step (1) to fix the wiring
cover plate again.
2. (1) (2) (3) (4) (5) (
)
(6) (
)
(7) (1)
N
L
Wiring Terminal
Power cord
3. Installing the Main Body Method 1 integrated ceiling. integrated ceiling should be 300*300, 300*450, 300*600
(1) Disassembly the decorated plate around the position of
the product installation.
Disassembly 6 pieces
6
300mm*300mm integrated ceiling
300mm*300mm
(2) Bend the installation template to 90 at the bending line.
° (2) 90
300mm*450mm integrated ceiling
300mm*450mm
Push the template to the location of fixed hole A in the ceiling as the diagram shows.
Install Template
Bending Line
3.
(1)
Disassembly 6 pieces
6
Install Template
300*300 300*450 300*600
()
Disassembly 3 pieces
3
300mm*600mm integrated ceiling
300mm*600mm
A( )
Install Template
Install Template
1367689-T01-A
Fixed Hole A
A
Cement Board
150
288
300mm*300mm integrated ceiling
300mm*300mm
-7-
Page 9
(3) Fix the suspender on the right position of the cement
board, use the install template to adjust the M6 nut on the suspender.
(3)
M6
M6 Butterfly Nut
Suspender
Cement Board
M6
6 Washer 6
6 Spring Washer 6
M6 Nut M6
(4) Fix the suspension bracket on the suspender by 8
BTP4*8 screw.
(4) 8 BTP4*8
BTP4*8 Triangular Self Tapping Screw BTP4*8 (4 )
Ceiling Surface
M6 Nut M6
Install template datum line
(5) Fix the product on the M6 suspender by the suspension
bracket.
(5) M6
M6 Butterfly Nut M6
6 Washer 6
6 Spring Washer 6
M6 Nut M6
1367689-T01-A
-8-
Page 10
(6) Install the air exhaust pipe
1) Fix the air exhaust pipe on the ventilation outlet assy. by the clamp. The pipeline connected to outside of the room must be slanted to prevent rain or condensed water from flowing backwards.
(6)
1)
Ventilation Outlet Assy.
BTP4*8 Triangular Self Tapping Screw BTP4*8 (1 )
(7) Install the decorated plate and adjust the nut on the
suspender to keep them on the same horizontal surface. Lock the nut after the adjustment.
Ventilation Outlet
Clamp
Air Exhaust Pipe
Indoors
Outdoors
Slant Taper
(7) M6 M6
Base
Decorated Plate
1
()
~
100150
(8) Install the remaining decorated plate (finish the product
installation)
1367689-T01-A
(8) ( )
300mm*300mm integrated ceiling
300mm*300mm
-9-
Page 11
4. Installing the Main Body Method 2 Ceiling mounting has not been installed. (1) Positioning and installation of the suspenders
1) Put the installation template to the position of fixed hole A and B on where the bathroom heater is going to be installed.
Cement Board
Install Template
Fixed Hole A
A
4.
(1)
1) AB
Fixed Hole B
B
2) According to the marked positions of screw rods, fix the rods on the ceiling.
Cement Board
Suspender
(2) Fix the ventilation outlet assy. to the main body using
the BTP4*8 self-tapping screw.
(3) Fix the suspension bracket to the main body using the 8
BTP4*8 self-tapping screws.
2)
(2) 1 BTP4*8
BTP4*8 Self Tapping Screw BTP4*8 (1 )
(3) 8 BTP4*8
(4) Fix the product on the M6 suspender by the suspension
bracket. Lock the nut after the installation.
1367689-T01-A
BTP4*8 Triangular Self Tapping Screw BTP4*8 (4 )
(4)
M6 Butterfly Nut M6
6 Spring Washer 6
6 Washer 6
M6 Nut M6
-10-
Page 12
(5) Install the air exhaust pipe
1) Fix the air exhaust pipe on the ventilation outlet assy. by the clamp. The pipeline connected to outside of the room must be slanted to prevent rain or condensed water from flowing backwards.
Ventilation Outlet
Clamp
(5)
1)
Air Exhaust Pipe
Indoors
Outdoors
INSTALLATION OF REMOTE CONTROLLER HOLDERINSTALLATION OF REMOTE CONTROLLER HOLDER
NOTE:
(such as wood board, density board and etc.), suitable fixing methods shall be adopted.
NOTE:
easily splashed by water.
Choose a mounting location for the remote holder.
Drilling two holes with depth larger than 45mm on the wall by drill with a diameter of 6mm in accordance with the position of screw holes on the remote control holder. Installing the expansion tube into the holes.
Placing the installation holder on the fixing hole.
Fixing the holder with screws and install it.
Installing the screw covers on the screws.
Placing the remote controller on the holder.
If the wall for installation is made of special material
The place to install the remote controller shall not be
Base
45mm
Slant Taper
1
()
~
100150
6mm
Remote Control
INSTALLATION OF COIN BATTERYINSTALLATION OF COIN BATTERY
Please follow the installation diagram.
Head
Bottom
Bottom
1367689-T01-A
Head
Cover
-11-
Screw
Expansion Tube
Head
Coin Battery (CR2430)
Bottom
Page 13
USER'S GUIDE
A. Before Using
Before using the remote control, please take off the
!
battery insulating strip. Before using the remote controller, please wait for 5
!
seconds after the power source is connected.
B. Paring
!
Please press "Light" and "Light Off" together within 3 minutes after connecting to power source. If "Beep, Beep, Beep" can be heard and the LED light is on, it means paring is successful.
A.
!
!
Battery Insulating Strip
B.
!
3
5
LED
C. Button Function C.
DOWN : Timer Down/Temperature Down.
UP : Timer Up/Temperature ON.
HEATER : Turn on the heater mode
FAN : Turn on the fan mode
DRY : Turn on the hot /cool dry clothes mode
VENTILATION : Turn on the ventilation/long time vent mode
AIR FLOW : Set the air flow swing or fixed
AIR-CARE : Turn on the air-care mode
LIGHT : Lighting on and off/chang the light color
Light Off :
STOP : Stop certain function
Turning off the light.
/
/
24
/
()
1367689-T01-A
-12-
Page 14
D. Display Information D.
Current
Set
Hour
Minute
Celsius
Humidity
HEATER
FAN
HOT DRY
COOL DRY
24H VENTILATION 24
VENTILATION
AIR-CARE
AIR FLOW FIXED
SWING MODE
E. Activated mode
During the standby mode, press any button to the
!
activated mode
, K-21464T-0 and K-21464T-X-0 will display room temperature and humidity, K-21466T-0 will display "00:00". Display will be turned off if not any further action is taken with 10 seconds. During the working mode, display the room temperature
!
and humidity. Display will be turned off after the countdown finish. Press the function button, the "beep will be heard.
!
"
F. Time setting
!
Setting time could be changed during the "HEATER",
"
"FAN , "DRY", "VENTILATION" and "AIR-CARE" mode.
!
Setting time will be changed back to the default after each use.
!
"HEATER": the default time is 3 hours, minimum time is 30 minutes, and maximum time is 6 hours.
!
If press "Stop" when the heater is working, the heater will continue to work for next 30 seconds to protect the machine and the remote control will show the count down.
!
"FAN": the default time is 3 hours, minimum time is 30 minutes, and maximum time is 6 hours.
!
!
!
!
!
"
"DRY : the default time is 3 hours, minimum time is 30 minutes, and maximum time is 6 hours. If press "Stop" when hot dry is working, the heater will continue to work for next 30 seconds to protect the machine and the remote control will show the count down. "VENTILATION": the default time is 3 hours, minimum time is 30 minutes, and maximum time is 6 hours. "AIR-CARE": the default time is 3 hours, minimum time is 30 minutes, and maximum time is 6 hours. "24H VENTILATION": the default time is 6 hours, the setting time cannot be changed.
E.
!
K-21464T-0 K-21464T-X-0
K-21466T-0 "00:00" 10
!
!
F.
!
!
!
6
!
!
6
!
!
!
!
!
/330
6
30
6
6
24 24
+-
330
30
330
330
330
1367689-T01-A
-13-
Page 15
G. Temperature Setting
Press "Heater" after the remote control is activated, and
!
the screen will show temperature setting. Pressing "+" or "-" can increase or decrease the heating temperature. Pressing "Heater" again within 10 seconds will turn to time set. "Heater": Default temperature is 40 C, maximum
!
temperature is 40 C while the minimum is 30 C.
°°
°
TROUBLESHOOTING
G.
!
!
30 C
°
40 C + -
°
10
40 C 40 C
°°
Problem Diagnosis
Bathroom Heater does not work.
The remote controller does not display.
The remote controller does not work.
A "Beep" alarm is on when turn on "Heater", "Ventilation", "Air-Care" and "Cloth Dry".
A. A power failure occurred.
B. The power cord is disconnected.
C. Circuit breaker is in the "Off" position.
A. The battery has been used up.
B. The polarity of battery was installed inversely.
C. No wake-up.
A. No pairing with the bathroom heater.
B. The remote controller is used in an
inappropriate position or angle.
C. Low battery.
A. Dust filter need be cleaned.
Solution
A. Wait until the power is restored.
B. Connect the power cord into the junction box
of bathroom heater.
C. Turn on the power at the breaker.
A. Please replace the battery.
B. Please install the battery correctly.
C. Press any key to wake-up.
A. Make the pairing.
B. Change the using position or angle to make
the controller towards the bathroom heater.
C. Change the battery.
A. Clean the filter or press the "+" for 2 seconds
in the Activated Mode.
A.
B.
C.
A.
B.
C.
A.
B.
C.
A.
A.
B.
C.
A.
B.
C.
A.
B.
C.
A. + 2
1367689-T01-A
-14-
Page 16
CARE & CLEAN
1. Shut off the power source, and turn around the wind swing assembly manually.
2. Hold the two ends of the filter, and take it off by pulling the assembly.
Filter
Holding Here
3. After the filter is cleaned, put it back to the wind swing assembly, on which there is an arrow symbol. Please make sure that the printed point is well matched with the mark to install the filter correctly. Finally, turn on the power and the wind swing assembly will restore automatically in 5 seconds.
Filter Printed Point
1.
Wind Swing Assy.
2.
Filter
3. (
)5
Filter Mark
IMPORTANT CONSUMER INFORMATION
1. When AC power unit is connected to 220V AC power supply, corresponding protective measures should be taken.
2. Please confirm no water penetration at the connection area of AC wire, and the connection area is not easy to be affected by damp.
3. The head AC power supply must be protected with appropriate fuse.
4. Please confirm the AC power supply should be shut off before maintaining the products with AC power related.
5. All electrical connection must be compliance with related regulation and codes.
6. All installation staff should be well familiar with installation instruction.
Notice: Troubleshooting needs to be done by professional of KOHLER CHINA. Users are not suggested to do this without help. Please remember that the checking and repairs done by users themselves could easily cause damage to the machine or cause physical harm to the person.
1. 220V
2.
3.
4.
5.
6.
1367689-T01-A
-15-
Loading...