WARNING: Risk of scalding or other severe injury.
•
Before completing installation, the installer must set the
maximum water temperature setting of this valve to minimize the
risks associated with scalding hazards according to ASTM F 444.
•
Do not install a shut-off device on either outlet of this valve. The
installation of any such device may create a cross-flow condition
at the valve and affect the water temperature.
•
Factors that change the temperature of the water supplied to the
valve, such as seasonal water temperature changes, and water
heater replacement or servicing, will change the maximum water
temperature supplied by the valve and may create a scalding
hazard.
•
The pressure-balanced valve will not compensate for changes in
the water supply temperature; adjust the maximum water
temperature setting of this pressure-balanced valve when such
changes occur.
•
Pressure-balanced valves may not provide protection against
scalding if there is a failure of other temperature-limiting devices
elsewhere in the plumbing system.
The installer is responsible for installing the valve and adjusting the
maximum water temperature of this pressure-balanced valve
according to instructions.
This valve meets or exceeds ANSI A112.18.1 and ASSE 1016.
If you do not understand any of the installation or temperature
adjustment instructions in this document, in the United States please
contact our Customer Service Department at 1-800-4-KOHLER.
Outside the U.S., please contact your distributor.
IMPORTANT NOTICE TO INSTALLERS! Please fill in the blanks in
the information box in the Homeowners Guide and on the valve label.
Retain the Homeowners Guide for future reference.
1006260-2-C2Kohler Co.
Tools and Materials
Strap
Wrench
Assorted
Screwdrivers
Thermometer
Plumbers
Putty
Thread
Sealant
Hex
Wrench
Thank You For Choosing Kohler Company
We appreciate your commitment to Kohler quality. Please take a few
minutes to review this manual before you start installation. If you
encounter any installation or performance problems, please don’t
hesitate to contact us. Our phone numbers and website are listed on
the back cover. Thanks again for choosing Kohler Company.
Before You Begin
Observe all local plumbing and building codes.
The finished wall or bath/shower unit must be installed prior to
installing this trim.
We recommend that you determine if the maximum water
temperature is acceptable before installing this trim. If
temperature adjustment is needed, refer to the ″Water
Temperature Adjustment″ section.
The valve shuts off by water pressure. Do not force the handle in
any direction. To turn the valve off, gently turn it to the ″Off″
position.
Shut off the main water supply.
Kohler Co. reserves the right to make revisions in the design of
products without notice, as specified in the Price Book.
Kohler Co.31006260-2-C
Copper
Tube
Apply
plumbers
putty.
Nipple
3-7/8"
(9.8 cm)
Apply plumbers
putty.
Standard
Length
Spouts
1-1/2" (3.8
cm) - 2-7/8"
(7.3 cm)
Setscrew
5/32" Hex Wrench
Nipple
Slip-Fit
Spouts
7"
(17.8 cm)
Apply plumbers
putty.
Large Spouts
1. Install the Spout
CAUTION: Risk of internal seal damage. Do not use
petroleum-based lubricants when installing slip-fit spouts. If the
spout will not slide over the tubing, use soapy water or a
silicone-based lubricant.
CAUTION: Risk of internal seal damage. Loosen the spout
setscrew with a 5/32″ hex wrench prior to installing the spout.
Slip Fit Spouts
Remove the temporary nipple from the bath elbow.
Apply thread sealant and install a 1/2″ copper tube so it extends
1-1/2″ (3.8 cm) to 2-7/8″ (7.3 cm) beyond the finished wall.
Deburr the copper tubing.
Loosen the setscrew with a 5/32″ hex wrench.
Apply a bead of plumbers putty or other sealant around the inlet
end of the spout according to the manufacturer’s instructions.
Install the spout and carefully retighten the setscrew. Do not
overtighten the setscrew.
Remove all excess putty.
For Threaded Spouts
Remove the temporary nipple from the bath elbow.
1006260-2-C4Kohler Co.
Install the Spout (cont.)
Apply thread sealant, and install a 1/2″ nipple so it extends
3-7/8″ (9.8 cm) beyond the finished wall for standard spouts and
7″ (17.8 cm) for large spouts.
Apply a bead of plumbers putty or other sealant to the back of
the spout according to the manufacturer’s instructions.
Apply thread sealant to the nipple, and install the spout to the
nipple. Carefully tighten with a clean strap wrench.
Remove excess putty.
Kohler Co.51006260-2-C
Shower
Elbow
Escutcheon
Shower Elbow
Escutcheon
Shower Arm
Apply
plumbers
Screen Washer
putty.
Showerhead
Showerhead
2. Install Showerhead
CAUTION: Risk of product damage. To avoid plugging the
showerhead spray outlets, use thread sealant tape on the shower
arm threads. Do not use thread sealant compound (pipe dope).
Remove the temporary nipple from the shower elbow.
Apply a bead of plumbers putty or other sealant to the back of
the escutcheon according to the manufacturer’s instructions.
Slide the escutcheon over the shower arm.
Apply thread sealant tape and install the shower arm to the
shower elbow.
Carefully tighten with a clean strap wrench.
Press the escutcheon against the finished wall.
Remove all excess putty.
With the showerhead off, flush out the system.
Apply thread sealant tape to the shower arm. Install the screen
washer (if required for your model) and thread the showerhead
to the shower arm.
Shower Arm
1006260-2-C6Kohler Co.
Standard
High Flow
Valve
Setscrew
Tab
Collar
Setscrew
Valve
Stem
O-Ring
Valve
Tab
Collar
Valve
Label
3. Water Temperature Adjustment
CAUTION: Risk of personal injury. The water temperature
should never be set above 120° F (49° C).
NOTE: Do not remove the O-ring and collar at this time. Removing
the O-ring and collar will change the factory setting for the
maximum water temperature.
Turn the valve clockwise to the full open position and let the hot
water run for several minutes. Position a thermometer in the
water stream and check the temperature.
For minor water temperature changes, adjust the setscrew, and
recheck the water temperature.
For major water temperature changes, remove the O-ring and
collar from the valve stem. Slowly rotate the valve stem until the
desired maximum water temperature is reached.
Reinstall the collar on the valve stem with the setscrew against
the side of the tab.
Reinstall the O-ring, rotate the valve stem counterclockwise to
shut the water off.
Recheck the water temperature to ensure desired maximum water
temperature.
NOTE: After adjustment, complete the required information on the
valve label (if supplied).
Kohler Co.71006260-2-C
Valve Stem
Discard plaster guard
with dome.
Screw
Sleeve
Faceplate
Screw
Washer
Insert
Handle
Screw
Insert
O-Ring
Handle
Washer
Screw
Plug Button
4. Install the Faceplate and Handle
CAUTION: Risk of product damage to the K-306–KS valve
assembly. When using this valve in a fiberglass or acrylic
installation, use the Thin Wall Installation Kit (88526).
Remove and discard the plaster guard and/or dome, if installed.
Install the faceplate onto the valve. Secure with two screws. Do
not overtighten.
Rotate the valve stem fully counterclockwise.
Slide the sleeve over the valve stem.
Lever Handle
Properly align the handle downward.
Press the handle and insert firmly onto the valve stem.
Secure the handle in place with the washer and screw.
Press the plug button firmly into place in the handle.
Acrylic Handle
Attach the insert and align it so the dot on the front edge is
facing downward in the 6 o’clock position.
Slide the O-ring into position and attach the handle. Make sure
the handle is aligned identically to the insert.
Secure the handle in place with the washer and screw.
Push the plug button firmly into place in the handle.
1006260-2-C8Kohler Co.
Guide d’installation
Baignoiremono-contrôleetgarniturede
douche
INSTRUCTIONS IMPORTANTES
À LIRE ET À LAISSER AU CLIENT
AVERTISSEMENT : Risque de brûlures ou de blessures graves.
•
Avant de commencer l’installation, l’installateur doit régler la
température maximale de l’eau de cette valve pour réduire au
minimum les risques de brûlures, ceci conformément à la norme
ASTM F 444.
•
Ne pas installer un dispositif d’arrêt sur les sorties de cette valve.
L’installation d’un tel dispositif peut créer une condition
d’écoulement croisé au régulateur et modifier la température de
l’eau.
•
Les facteurs qui changent la température de l’eau alimentée à
cette valve, tels que les changements de température d’eau
saisonniers, et le remplacement ou l’entretien du chauffeau,
changeront la température maximale de l’eau fournie par le
régulateur et pourront présenter un danger de brûlures.
•
La valve à pression équilibrée ne compensera pas les
changements de température d’alimentation d’eau; ajuster la
température maximale de cette valve à pression équilibrée si de
tels changements se produisent.
•
Les valves à pression équilibrée peuvent ne pas assurer une
protection contre les brûlures en cas de défaillance d’autres
dispositifs de limitation de température installés ailleurs sur le
réseau de plomberie.
L’installateur est responsable de l’installation de la valve et du
réglage de la température maximale de l’eau de cette valve à pression
équilibrée conformément aux instructions.
Cette valve satisfait ou excède les exigences des normes ANSI
A112.18.1M et ASSE 1016.
S’il ne vous est pas possible de comprendre les instructions
d’installation ou de réglage de la température données par ce
document, veuillez contacter notre département du service clientèle
aux États-Unis.1-800-4-KOHLER. Hors des États-Unis, veuillez
contacter votre distributeur.
Kohler Co.Français-11006260-2-C
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.