M product numbers are for Mexico (i.e. K-12345M)
Los números de productos seguidos de
M corresponden a México (Ej.
K-12345M)
Français, page ″Français-1″
Español, página ″Español-1″
1006741-2-G
Tools and Materials
Tape
Measure
DrillSolder
Pencil
Adjustable
Wrench
Level
Tape
Measure
Silicone
Sealant
Plus:
• 2x4 Lumber
• 1x3 Lumber
• Pipe Strap
Propane
Torch
Before You Begin
Shut off the main water supply.
Observe all local plumbing and building codes.
Do not use this flow spout as a showerhead because it will cause
excessive splashing and does not meet showerhead codes.
This flow spout is available in two orifice sizes: 3/4″ (2 cm) and
15/16″ (2.4 cm). The smaller orifice size is designed for a 5-10
gpm (19-38 lpm) flow rate, and Kohler K-400-K, K-401-K, or
K-306-KS supply valves are recommended. The larger orifice size
is designed for a 7-15 gpm (26-57 lpm) flow rate, and Kohler
K-300-K or K-301-K supply valves are recommended.
Screwdrivers
NOTE: A flow rate lower than the flow rate listed on the
specification sheet may disrupt the water flow.
The drip tray is an optional accessory available for the wall
mount but not for the ceiling mount.
A water hammer arrestor is recommended in ceiling mounted
applications using a high flow, deck mounted valve. Kohler
recommends that a Sioux Chief 652-AD vacuum breaker arrester
be located near the outlet side of the valve. Contact Sioux Chief at
1-800-821-3944 or www.siouxchief.com.
For ceiling mount applications, the height from the bottom of the
bath to the spout should not exceed 9’ (2.7 m).
1006741-2-G2Kohler Co.
Before You Begin (cont.)
In applications where excessive air could enter the water supply,
install an air separator.
When a deck mounted transfer valve (K-408-K or K-409-K) is
used for a ceiling mount, install a check valve between the spout
and the diverter.
Remove the mounting sleeve and cartridge before installing the
spout body.
Kohler Co. reserves the right to make revisions in the design of
products without notice, as specified in the Price Book.
Kohler Co.31006741-2-G
7" (17.8 cm)
Enter
Offset Installation
Bath
Center Installation
Bath
1. Determine the Location
CAUTION: Risk of property damage. When employing a
wall mount installation, install this spout at the end of the
bathing fixture so the water stream projection stays within
the bathing fixture.
There are three recommended installation configurations for the
spout: 1) offset wall mount, 2) center wall mount, and 3) ceiling
mount. The offset wall mount is highly recommended for the
safety of the user.
Offset Installation
The spout assembly is placed 7″ (17.8 cm) from the center of the
bathing fixture, away from the entry side of the fixture.
The offset configuration allows users to avoid the stream of water
when entering or using the bathing fixture.
Center Installation
The spout assembly is positioned directly above and on the
centerline of the bathing fixture.
This installation should only be used when the offset installation
is not possible.
1006741-2-G4Kohler Co.
One Bather
Ceiling Installation Range
Enter
Two Bathers
Enter
2. Ceiling Installation Layout
Install the spout in the ceiling over the bathing fixture at the
shaded areas shown in the illustration.
Mount the spout so it is 9’ (2.7 m) or less from the bottom of the
bathing fixture.
Locate the spout so the water stream contacts the flat bottom of
the bathing fixture. Excess splashing will occur if the water
stream contacts whirlpool jets or bathing fixture corners.
Kohler Co.51006741-2-G
Backup
2x4's
5-5/8"
(14.3 cm)
2"
(5.1 cm)
Bathing
Fixture
Plate
Mounting
Plate
3. Install the Drip Tray Mounting Plate
NOTE: The drip tray is an optional accessory available for wall
mount but not for ceiling mount.
Install nut
and
washer.
Stud
Drywall or
#10 Wood
Screws
NOTE: Install the 2x4’s so the drip tray is level or has a slight
forward slope to ensure proper drainage.
Attach a 2x4 flush to the back of the wall stud to support the
lower lip of the drip tray mounting plate. Position the 2x4 so it
will be 2″ (5.1 cm) above the top of the bathing fixture.
Attach a second 2x4 so it is 5-5/8″ (14.3 cm) above the first 2x4.
NOTE: When 2x6 wall studs are present, install the 2x4’s so they are
supported 2″ (5.1 cm) from the back of the wall stud.
Attach the drip tray mounting plate to the 2x4’s using six drywall
or #10x1″ screws. Make sure the mounting plate is centered under
the spout’s location.
1006741-2-G6Kohler Co.
Valve Outlet Tubing
Pipe Strap
3/8"
(1 cm)
1x3
4"
(10.2 cm)
Intake
Pipe
Spout
Assembly
7-5/8"
(19.4 cm)
2x4
4. Install the Spout – Wall Installation
Install a 2x4 for spout support so it lays flush against the top
support of the drip tray. If the drip tray is installed, the spout
center must be 7-5/8″ (19.4 cm) from the drip tray mounting
studs. If the drip tray is not installed, the spout center must be
14-16″ (35.6-40.6 cm) from the deck of the bathing fixture.
NOTE: When 2x6 wall studs are present, the front of the 2x4 must
be flush with the front of the wall stud.
Install a 1x3 so it is 4″ (10.2 cm) above the 2x4 and inset 3/8″ (1
cm) from the back of the studs. The larger side of the 1x3 must
face outward.
NOTE: When 2x6 wall studs are present, install the 1x3 so it is
2-3/8″ (6 cm) from the back of the wall stud.
Place the spout assembly into position. Verify that the spout and
drip tray mounting plate (if installed) are centered.
Remove the boot cap from the end of the intake pipe.
Remove the mounting sleeve and cartridge.
Kohler Co.71006741-2-G
Install the Spout – Wall Installation (cont.)
Solder the intake pipe to the valve outlet tubing.
Secure the valve outlet tubing to the 1x3 using a pipe strap.
1006741-2-G8Kohler Co.
Back Plate
2x4
Screw
3-3/4"
(9.5 cm)
Intake Pipe
Spout
Assembly
5. Install the Spout – Ceiling Installation
Install a 2x4 for support in the location where the spout will be
mounted. Position the 2x4 support so it is 3-3/4″ (9.5 cm) from
the bottom of the joist.
Install the spout assembly to the 2x4 using two wood screws,
inserted at the angles shown, through the holes in the back plate.
Remove the boot cap from the end of the intake pipe.
Remove the mounting sleeve and cartridge.
Solder the intake pipe to the valve outlet tubing.
Kohler Co.91006741-2-G
3-3/8" D. (8.6 cm)
(spout hole)
Finished
Wall
Add sealant
to groove.
7-5/8"
(19.4 cm)
3" (7.6 cm)
Installed
Spout
Mounting
Sleeve
Mounting
Plate
1-1/2"
(3.8 cm)
1/2" D. (1.3 cm) holes
(optional drip tray studs)
6. Complete the Installation
Complete the finished wall and/or ceiling.
If installing the optional drip tray, make sure the studs are
positioned and tightened correctly.
Apply silicone sealant to the groove in the flange of the mounting
sleeve.
Insert the mounting sleeve in the spout. Align the three screw
holes.
1006741-2-G10Kohler Co.
Installed Mounting
Sleeve
Cartridge Assembly
Orifice
Screw
O-Ring
Decorative
Flange
7. Assemble the Spout
Slide the cartridge assembly onto the orifice O-ring until it fits
snugly. Install the cartridge assembly/orifice into the mounting
sleeve and align the holes.
Install the three screws and tighten until the sleeve and orifice are
tight against the wall.
Thread the decorative flange clockwise into the orifice and
hand-tighten until secure against the wall.
Kohler Co.111006741-2-G
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.