Thank You For Choosing Engleeld
Before You Begin
Tools and Materials
CAUTION: Risk of personal injury or product damage. Handle
with care. Vitreous china can break or chip if the product is handled
carelessly.
Thank You For Choosing Engleeld. We appreciate your commitment to
Engleeld quality. Please take a few minutes to review this manual before
you start installation. If you encounter any installation or performance
problems, please don’t hesitate to contact us. Our phone numbers and
website are listed on the back cover. Thanks again for choosing Engleeld.
Observe all local plumbing and building codes.
Carefully inspect the new toilet for damage.
If the existing toilet does not have a supply shut-o valve below the
cistern, install one before installing the new toilet.
Install sucient backing behind the nished wall to provide a secure
material for the anchoring devices.
Check that you have recieved the correct toilet pan, tank and seat, as
outlined in the following table on page 3.
1104782-A2-D 2 ENGLEFIELD

Description
Suite code
Image
Included components
Pan
Tank
Seat
Domani link piece
S-Trap 4 star
Emerald CC
S-Trap 4 star
45541A-0 18304A-0 18309A-0 16998A-0
Emerald CC
P-Trap 4 star
12754A-0 18302A-0 18303A-0 1063069
45542A-0 18305A-0 18309A-0 16998A-0
Delano CC
S-Trap 3 star
8833A-0 8831A-0 1833A-0 16998A-0
Delano CC
P-Trap 3 star
8835A-0 8831A-0 1833A-0 16998A-0
Delano CC
S-Trap 4 star
12758A-0 18307A-0 18309A-0 16998A-0
Delano CC
P-Trap 4 star
12759A-0 18308A-0 18309A-0 16998A-0
Mirage CC
S-Trap 4 star
12756A-0 18304A-0 18306A-0 16998A-0
Mirage CC
P-Trap 4 star
12757A-0 18305A-0 18306A-0 16998A-0
Milano Elite
BTW Vario 4 star
7380A-0 17485A-SST-0 15568A-0 7379A-0
Milano
BTW Vario 4 star
12695A-0 17485A-SST-0 15568A-0 16999A-0
ENGLEFIELD 3 1104782-A2-D

Installation
2 Dene the position of connector: Place the connector onto the pan, position
between outlet and waste pipe.
1 Remove the existing toilet: Turn o the water supply and ush the toilet, then
sponge out all remaining water from the cistern. Disconnect the supply shut-o
valve (if present), and remove the old pan and cistern.
CAUTION: Risk of hazardous gases. If the new toilet is not installed immediately,
temporarity stu a rag in the closet ange.
1104782-A2-D 4 ENGLEFIELD
Case 1 Case 2
Finished
Wall
Finished
Wall
Pan
Connector
Straight Pipe
Connector
Vario Pipe
Connector
Setout
Pan
Setout
Case 3
Finished
Wall
Connector
Vario Pipe
Connector
Pan
Setout
Offset Pan Collar

3 Bracket
Drill 3/8” (10 mm) mounting hole between the mark locations on the oor
and insert the anchor. Install the washer and insert the hexagon screw into
the bracket then tighten the screw. Install the sleeves, tighten the screw and
aach the caps.
4 Screw
Drill 5/16” (8 mm) mounting hole at the marked locations. Insert anchors into
the holes. Place the toilet and aligh anchoring holes position. Tighten screws and
aach the bolt caps.
Floor xing option
ENGLEFIELD 5 1104782-A2-D
Anchor
Screw
Sleeve
Hole
Cap
Hexagon
Lag Screw
Bracket
Washer
Anchor
Fixing Holes
Screw Cap
Screw
Anchor
Sleeve
Drill

5 Cistern Mounting Hole: Install
sucient backing behind the nished
wall. Mark the cistern mounting hole
according to the rough-in.
(Alpha cistern only)
6 Install the Cistern to Wall: Drill
15/16” (8 mm) mounting hole on
mark location, insert the anchors.
Position the cistern, tighten the
screw and aach the caps. Assembly
ush valve as picture below.
(Alpha cistern only)
7 Install the seat as per the supplied seat instructions
1104782-A2-D 6 ENGLEFIELD
2-3/8"
(6 cm)
Rear
Water
Inlet
31-1/2"
(80 cm)
Anchor
Screw
Link Holder
Holder
Nut
Cistern
Rubber Washer
Plastic
Washer
Pipe
Gasket
Cover
Washer
Sleeve

9 Connect the supply shut-o valve to the supply hose and connect supply hose
to toilet supply shank.
8 Position the cistern on the pan by centering the gasket on the pan inlet. As-
semble the retaining washing and sealing washer to the screw. Securely tighten
the screw so the cistern is level.
Tank xing
ENGLEFIELD 7 1104782-A2-D
Screw
Plan Washer
Sealing Washer
Nut
Plastic Nut
Gasket
Screw
Retaining Washer
Plan Washer
Fiber Washer
Sealing Washer
Screw
Washer
Screw
Nut
Plastic*
Brass*
* Optional for different product
Brass*
Water
Supply
Hose
Water Supply Hose
(Not supplied)
Rear Inlet TypeBottom Inlet Type

Installation
10 Cistern details.
1104782-A2-D 8 ENGLEFIELD
Models: 12754A-0
Bottom Water Inlet - Link Piece
Inlet Valve
Flush Valve
Models: 7380A-0,
12695A-0
Rear Water Inlet - Close Coupled
Inlet Valve
Flush Valve
Hose
Models: 12756A-0, 12757A-0,
8833A-0, 8835A-0,
12758A-0, 12759A-0,
45541A-0, 45542A-0
Bottom Water Inlet - Close Coupled
Inlet Valve
Flush Valve
For use with models: 7380A-0
12695A-0
Stop Valve
Tank Hose
Bottom Water Inlet - Coversion Kit
(148794A-NA)
Inlet Valve
Flush Valve

Install the Push Buttons
1 Disassemble the push rods.
2 Using the push rod, measure the
distance between the ush valve and
the top of the tank lid. Mark this
lengh and cut the push rod to length.
Cut the push rod to length.
3 Reassemble the push rods. 4 Fit the lid and test the buons. Adjust
the rods as required.
ENGLEFIELD 9 1104782-A2-D

Install Flush Valve
2 Assemble ush valve by pushing
straight down into the canister and
turning left.
Flush Valve B
1 Release ush valve by squeezing
the tabs on both sides of the
canister and pulling straight up
out of the ush valve.
2 Assemble ush valve by pressing it
into the ush valve base so it snaps
into place.
Flush Valve A
1 Release flush valve by turning
right and pulling straight up on the
canister.
1104782-A2-D 10 ENGLEFIELD
1
2
1
2

ENGLEFIELD 11 1104782-A2-C

1104782-A2-D
CALL US FOR HELP
NEW ZEALAND
KOHLER NZ LTD
Free Ph: 0800 100 382
Free Fax: 0800 664 488
www.englefield.co.nz
AUSTRALIA
KOHLER CO.
Free Ph: 1 800 228 476
www.englefield.com
CONTACT AND WARRANTY INFORMATION
For warranty information, please visit our website
Australia
www.englefield.com
New Zealand
www.englefield.co.nz