Kodak UPB10011 Owner Manual

Page 1
KODAK Smart Air Puriier
AP550 DUAL FAN
User Manual
The features described in this User Manual are subject to modiications without prior notice.
AP550_User Manual_V1.8
P.1
Page 2
TABLE OF CONTENTS
1. IMPORTANT SAFETY INSTRUCTIONS
2. PRODUCT PARTS OVERVIEW
3. CONTROL PANEL
4. DISPLAY ICONS
5. OPERATION INSTRUCTIONS
6. MOBILE APP DISPLAY ICONS
4
10
11
12
14
24
8. GRANT ACCESS
9. TROUBLESHOOTING
10. SPECIFICATIONS
11. EXCLUSION FROM COVERAGE
12. FCC, IC AND CE REGULATIONS
13. WARNING
52
54
56
57
59
61
7. OPERATION INSTRUCTIONS
(MOBILE APP)
26
14. EC DECLARATION OF CONFORMITY
63
P.2 P.3
Page 3
1. IMPORTANT SAFETY INSTRUCTIONS
WARNING:
Danger
• Do not let water or any other liquid or lammable de­BEFORE USING THE KODAK SMART AIR PURIFIER, PLEASE READ THROUGH ALL THE INSTRUCTIONS AND CAUTIONARY MARKINGS IN THE MANUAL AND ON THE AIR PURIFIER. PLEASE KEEP IT FOR FUTURE REFERENCE.
This appliance can be used by children aged from 8+ years old and people with reduced physical, sensory or mental abilities or lack of experience and knowledge, only if they are under supervision or have been given instructions concern­ing the use of the appliance in a safe way and understanding the hazards involved. Children shall not play with the appli­ance. Cleaning and user maintenance shall not be undertak-
tergent enter the air puriier to avoid electric shock and/or a ire hazard.
• Do not clean the WHOLE air puriier with water, any
other liquid, or a (lammable) detergent to avoid electric shock and/or a ire hazard.
• Do not spray any lammable materials such as insec-
ticides or fragrance around the air puriier.
Warning
en by children without supervision.
Please place at least 30cm away from any metal surfaces or objects.
Any metal surface or
Recommend >30cm
objects
• Check if the voltage indicated on the air puriier corre-
sponds to the local power voltage before you connect the appliance.
• Do not use the air puriier if the plug, the power cord,
or the appliance itself is damaged.
• Do not block the air inlet and outlet, e.g. by placing
items on the air outlet or in front of the air inlet.
• Make sure that foreign objects do not fall into the air
puriier through the air outlet.
P.4 P.5
Page 4
Caution
• Leave at least 30 cm free space all around the device (back,front & sides) and at least 40cm above the air puriier.
• This air puriier is not a substitute for proper ventila­tion, regular vacuum cleaning, or use of an extractor hood or fan while cooking.
• If the power socket used to power the air puriier has poor connections, the plug of the air puriier becomes hot. Make sure that you plug the air puriier into a properly connected power socket.
• Avoid knocking against the air puriier (the air inlet and outlet in particular) with hard objects.
• Always lift or move the air puriier by the handle on top of the device.
• Do not insert your ingers or objects into the air outlet or the air inlet to prevent physical injury or malfunc­tioning of the air puriier.
• Do not use this air puriier when you have used indoor smoke-type insect repellents or in places with oily resi­dues, burning incense, or chemical fumes.
• Always place and use the air puriier on a dry, stable, level, and horizontal surface.
• Do not place anything on top of the air puriier.
• Do not sit or stand on the air puriier. Sitting or stand­ing on the appliance may lead to potential injury.
• Make sure the reusable ilter, front cover and back cov­er are properly installed before you switch on the air puriier.
• Only use the original reusable ilter specially intended
• Do not use the air puriier near gas appliances, heating devices or ireplaces.
• Always unplug the air puriier after use and before cleaning or carrying out other maintenance.
• Do not use the air puriier in a room with major tem­perature changes, as this may cause condensation inside the air puriier.
• To prevent interference, place the air puriier at least 2 meters away from other electrical appliances that
for this KODAK Smart Air Puriier. Do not use any other ilters or add any extra ilters in the device.
P.6 P.7
use airborne radio waves such as TVs, radios, and ra­dio-controlled clocks.
Page 5
• The air puriier is only intended for household use
• Suitable for dry location ONLY. Do not use outdoors or
under normal operating conditions.
• If you need to move the air puriier, disconnect it from the power supply irst.
• When moving the air puriier, do it slowly and do not push it rapidly.
• Do not move the air puriier by pulling its power cord.
• This KODAK Smart Air Puriier is not intended for use by people (including children) with reduced physical, sen­sory or reasoning capabilities, or lack of experience and
on wet surfaces and do not expose to water or rain.
• Do not handle any part of the plug or device with wet hands.
• Do not operate any device with a damaged cord or plug. Discard the device or return to an authorized ser­vice facility for examination and/or repair. If the supply cord is damaged it must be replaced by oicial chan­nel, its service agent or similarly qualiied person in order to avoid a hazard.
• If the device is not working as it should, has received
knowledge, unless they are under supervision or have been given instructions concerning the use of the de­vice by a person responsible for their safety.
• Ensure the device is fully assembled in line with the instructions before use.
• Do not allow to be used as a toy. Close attention is nec­essary when used by or near children. Children should be supervised to ensure that they do not play with the device.
• Use only as described in this KODAK Smart Air Puriier
a sharp blow, has been dropped, damaged, left out­doors, or dropped into water, do not use it and con­tact the Kodak Smart Home Customer Support team.
• Do not stretch the cord or place it under any strain. Keep the cord away from any heated surfaces.
• Do not run the cord under carpeting. Do not cover the cord with rugs, runners or similar coverings. Do not route the cord under furniture or any appliances. Place the cord away from any traic area and where it will not be tripped over.
User Manual. Do not carry out any maintenance other than the one shown in this User Manual, or advise given by the Kodak Smart Home Customer Support
• Do not use any cleaning agents or lubricants on this device. Unplug it before cleaning or carrying out any maintenance .
team.
P.8 P.9
Page 6
2. PRODUCT PARTS OVERVIEW 3. CONTROL PANEL
Screen Button
Reusable and Washable Filter
Power On/O
Button
Front
Cover
Back Cover
P.10 P.11
Page 7
4. DISPLAY ICONS
PM2.5 Reading
Air Quality Rings
Mode Display
29
˚C
89
Good
%
000-050
Temperature
Reading
Mode Display
˚C
89
29
˚C
29
Capital letter “A” indicates that the air puriier is in Auto mode.
%
89
%
Humidity Reading
29
29
˚C
˚C
89
89
Moderate
%
051-100
Unhealthy
%
101-300
Hazardous
“No WiFi connection icon” indicates that the air
29
29
˚C
˚C
89
89
puriier cannot connect to the WiFi (router)
%
“No Internet connection icon” indicates that the air puriier cannot connect to the Internet
%
29
˚C
89
%
P.12 P.13
301-500
This view shows that the device is not able to detect the air quality correctly. Please Re­set the device. If the problem persists contact the KODAK Smart Home Customer Support team.
Page 8
5. OPERATION INSTRUCTIONS
Setup
• Plug in the provided power adaptor to a power socket, then plug in the DC plug into the DC jack located at bottom of the air puriier to power up the device.
Power ON
• Press the power button once to turn ON the air puriier.
x1
Power OFF
• Press the power button for 3 sec to turn OFF the air puriier.
3 sec
P.14 P.15
Page 9
Change fan speed and auto mode
Sleep mode
• Press the Screen button to switch the fan speed and auto mode. The change sequence is Fan Speed 1
-> Fan Speed 2 -> Fan Speed 3 -> Auto Mode -> Fan speed 1 -> ... (loop) See igure below
• Press the screen button for 2 seconds, to enter sleep mode.
• In sleep mode, the LCD display will turn o. And the fan speed will also change according to PM2.5 read­ing, just like auto mode, but the power of the fans is relatively reduced to provide a quieter environment for sleep.
2 sec
• In auto mode, the fan speed will change according to PM2.5 reading. If the PM2.5 reading increases, the fan speed will automatically and progressively increase. The same will happen if in the meantime the PM2.5 reading decreases, then the fan speed will automat­ically and progressively decrease according to the PM2.5 reading.
• Press the Screen button once to exit sleep mode if the air purifier is in sleep mode.
x1
P.16 P.17
Page 10
Cleaning
P.18 P.19
Page 11
Pairing mode
• Press the Screen button and power button simultaneously for 2 seconds to enter pairing mode.
2sec
KODAK
Smart Home App
• Pairing Flow
1. Select Air Puriier op­tion to start pairing
2. Tap Continue after holding 2 buttons and hearing a beep sound
3. (For IOS only) Tap the Go to Settings to access to the Wi-Fi settings
P.20 P.21
Page 12
4. (For IOS only) In the
Wi-Fi settings, connect to Puriier-VXXXXXXXXX and return to the app
5. Wait while pairing in progress
6. You may choose one of the recommended names or customise it.
7. Tap Continue after customizing your name
8. Waiting while the app is setting up the names
9. Tap Done to conirm the setup
P.22 P.23
Page 13
6. MOBILE DISPLAY APP ICONS
Swipe Left or Right to view
other air puriier devices
Quick Start Guide
Move up or down to show outdoor weather information
Auto Mode
Sleep Mode Timer
Graph
Air Quality Indicator
Power On/ O
Fan Speed
Sleep Mode
Schedule
P.24 P.25
Page 14
7. OPERATION INSTRUCTIONS ( MOBILE APP)
• Sign up or Login KODAK Air Puriier app
To download the KODAK Smart Home app:
• On your mobile device, visit the App Store (iOS) or Google Play (Android)
• Search for KODAK Smart Home app
• Download and install the KODAK Smart Home app on your mobile device
scan to install
P.26 P.27
Page 15
• Create or Login to Your Account
If this is your irst KODAK Smart Home product, you will be asked to create an account. To set up an account:
• On your mobile device, open the KODAK Smart Home app
• Tap SIGN UP
• Follow the in-app instructions to create a new account
If you already have another KODAK Smart Home prod- uct installed, simply select LOGIN:
P.28 P.29
Page 16
• Pairing
1. Select Add New Device
P.30 P.31
2. Select Air Puriier
option
3. Tap Continue after following the steps 12 above
4. (For IOS only)
Go to settings
and connect to WiFi Puriier-Vxxxxxxxx
5. (For IOS only)
Return to the app and proceed to the next step
Page 17
6. Wait while pairing in
7. You may choose one
8. Tap Continue after cus-
9. Tap Done to conirm the
progress
P.32 P.33
of the recommended names or customise it.
tomizing your name
setup
Page 18
• Observe the Filter Usage
1. Tap to open the side menu
P.34 P.35
2. Tap Filter Usage
3. When the status bar of the Filter Usage is 100%, it means that the device ilter needs to be cleaned
Page 19
• Power On/O
1. Tap to Power on
P.36 P. 37
2. Tap to Power o
Page 20
• Change the Fan Speed
Indicates that the fan
1. Tap to activate to
2. speed is low
fan speed
P.38 P.39
3. Indicates that the fan speed is middle
4. Indicates that the fan speed is high
Page 21
• Set Auto Mode
• Set Sleep Mode
1. Tap to activate the auto mode
P.40 P.41
2. auto mode is on
Indicates that the
1. Tap to activate the sleep mode
2. sleep mode is on
indicates that the
Page 22
• Set a Sleep Mode Timer
• Delete a Sleep Mode Timer
1. Tap to activate the sleep timer
P.42 P.43
2. A timer will pop up, select the time and tap
conirm
1. Tap to show the sleep timer again
2. A timer will pop up, tap Delete to delete the timer previously set
Page 23
• Cleaning
1. When this shows the device filter needs to be cleaned, just tap on the screen, to view the cleaning guide steps
P.44 P.45
2. Follow the cleaning guide steps to clean the ilter
3. Cleaning Finished will show when the user has followed all steps of cleaning guide
Page 24
• Graph
1. Tap to read the
2. Tap
average PM2.5 data
average temperature data
P.46 P.47
to read the
3. Tap to read the average humidity data
4. Tap the average humidity and temperature data
and to read
Page 25
• Schedule
Schedule
Start
End
Repeat
1. Toggle to activate the schedule
2. Press Start or End to setup the duration
3. Select the time period and press Conirm to
4. Press Repeat to setup the time schedule
activate the duration
P.48 P.49
Page 26
5. Press Conirm to setup the time schedule
P.50 P.51
Page 27
8. GRANT ACCESS
8.1 Add Friend
You may grant access to your family and friends using the feature called Grant Access which is located on the side menu of the Dashboard.
1. Click on “ ” which is located on the Dashboard
P.52 P.53
2. Select Grant Access under
Devices
3. Click on + which is located on the top right
4. Simply follow the instructions on the app and click Save to add a friend
Page 28
• Check the front cover to see if it is properly in-
9. TROUBLESHOOTING
No Screen display, no light indicator
• Check the power plug to see if it is properly plugged at your power socket.
• Check the DC connector to see if it is properly plugged in the air puriier’s DC jack located under the air puriier.
• Check the reusable ilter to see if it is properly in-
stalled. The front cover should be all the way up and locked at the front of the air puriier, and the foam is located underneath the front cover as shown.
stalled in the air puriier. The reusable ilter should be at same level as the front panel if it is properly installed as shown.
• Check the back cover to see if it is properly in­stalled. The back cover should be all the way up and locked at the back of the air puriier, and the stopper should be well screwed underneath the back cover as shown.
P.54 P.55
Page 29
10. SPECIFICATIONS
Power Adaptor Input: 100240v, 50/60Hz
11. EXCLUSION FROM COVERAGE
Output: DC 15V, 1.5A
CARD 180+cmf
Suggested Room
450550sq.ft
Area
Dimensions 8.9” (W) x 6”(D) x 15.5”(H);
226mm(W) x 152mm (D) x 394mm
(H)
Net Weight 9.36LBS ; 4.3kg
Frequency Band 24122472MHz for b, g, n20 (
24222462MHz for n40 (CE)
24122462MHz for b, g, n20 (
24222452MHz for n40 (FCC&IC)
CE)
FCC&IC)
• Normal Wear and Tear: Regular maintenance, repair and replacement of parts and components due to normal wear and tear are not covered.
• Abuse & Misuse: Defects or damage due to: (a) improper operation, storage, misuse or abuse, accident or neglect, such as physical damage (such as cracks and scratches) to the surface of the product resulting from misuse; (b) contact with liquid, water, rain, extreme humidity or heavy perspiration, sand, dirt or the like, extreme heat, or food; (c) use of the Products or Accessories for commercial purposes or subjecting the Product
Operating
0 to 40 deg.C
Temperature
Maximum RF Power
Storage
EIRP 15dBm (
CE)
Conduct Power 18dBm (FCC & IC)
-10 to 70 deg.C
Temperature
*The above speciication are only for reference. With
more advanced development and innovation, the speciications will be changed.
or any Accessory to abnormal usage or conditions; or (d) other acts which are not the fault of eBuyNow or its authorised distributor, are not covered.
P.56 P.57
Page 30
12. FCC, IC AND CE REGULATIONS
• Use of Non-eBuyNow branded Products and Accessories: Defects or damage due to the use
of non-eBuyNow branded or certiied Products or Accessories or other peripheral equipment are not covered.
• Unauthorised Service or Modiication: Defects or damage due to service, testing, adjustment, installation, maintenance, alteration, or modiication in any way by someone other than eBuyNow, or its authorised service centers, are not covered.
Trade Name: Model:
FCC IC HVIN
FCC Part l5
NOTE: This equipment has been tested and found
KODAK
AP550 / Kodak Air Puriier Duo / Kodak Smart Air Puriier AP550 DUAL FAN
2AT76AP550 22297AP550 AP550
• Altered Products: Products or Accessories with (a) serial numbers or date tags that have been removed, altered or obliterated; (b) broken seals or that show evidence of tampering; (c) mismatched board serial numbers; or (d) nonconforming or eBuyNow branded housings, or parts, are not covered.
• Communication Services: Defects, damages, or the failure of Products or Accessories resulting from any communication service or signal you may subscribe
to comply with the limits for a Class B digital device, pursuant to Part 15 of the Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment to or use with the Products or Accessories are not covered.
P.58 P.59
o and on, the user is encouraged to try to correct
the interference by one or more of the following
measures:
Page 31
• Reorient or relocate the receiving antenna.
• Increase the distance between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Changes or modiications to this equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
• This device complies with Part 15 of the FCC rules.
13. WARNING
Changes or modiications, to this equipment not expressively approved by the party responsible for compliance could void the user’s authority to operate the equipment.
The socket-outlet shall be installed near the equipment and shall be easily accessible.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference,and (2) this device must accept any interference received, including interference that may cause undesired operation.
To ensure safety of users, the FCC has established criteria for the amount of radio frequency energy that can be safely absorbed by a user or bystander according to the intended usage of the product. This product has been tested and found to comply with the FCC criteria.
Industry Canada
This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.
This Class B digital apparatus complies with Canadian ICES003. CAN ICES3(B)/NMB3(B)
P.60 P.61
Page 32
14. EC DECLARATION OF CONFORMITY
We the manufacturer/ Importer: PerimeterSafe/eBuyNow
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
declare under our sole responsibility that the following product
Type of equipment: Air Puriier Model: AP550 / Kodak Smart Air Puriier AP550 DUAL FAN / Kodak Air Puriier Duo Brand: KODAK
complies with the essential protection requirements of RED Directive 2014/53/EU on the approximation of the laws of the Member States relating to Radio Spectrum Matters, the Council Directive 2004/108/EC on the approximation of the laws of the Member States
RF Radiation Exposure Statement Caution:
This Transmitter must be installed to provide a separation distance of at least 20cm from all persons.
IC Radiation Déclaration d’exposition Attention:
Cet émetteur doit être installé pour fournir une distance de séparation d’au moins 20cm de toute personne.
relating to electromagnetic compatibility (EMC) and the European Community Directive 2006/95/EC relating to Electrical Safety. Directive 2011/65/EC on the restriction of use of hazardous substances (RoHS).
P.62 P.63
Page 33
Assessment of compliance of the product with the requirements relating to the essential requirements:
Radio Spectrum: EN300328 V2.1.1
EMC: EN3014891 V2.1.1
EN30148917 V3.1.1 EN550141:2017 EN550142:2015 EN6100032:2014 EN6100033:2013
Electrical Safety: EN603351:2012/A11:2012
EN503352165:2003/A13:2017
RF Safety: EN62311:2008
Ozone test: UL867, section 40 CSA C22.2 No.187
The product is labeled with the European Approval Marking CE as shown. Any unauthorized modiication of the product voids this Declaration.
The Kodak trademark, logo and trade dress are used under license from Kodak
P.64 P.65
AP550_User Manual_V1.8