Keyence FS-V31, FS-V30, FS-V31P, FS-V31C, FS-V31CP Instruction Manual

...
1
DIGITAL FIBER SENSOR
FS-V30/31(P)/31C(P)/31M/32(P)/32C(P)
Instruction Manual
Part Names
I/O Circuit
FS-V31/32/31M FS-V31P/32P
FS-V31C/32C
Output Circuit Diagram Input Circuit Diagram
FS-V31CP/32CP
Output Circuit Diagram Input Circuit Diagram
Socket Cable (Sold Separately)
For FS-V31C(P)/32C(P) Pin and wire color table
Mounting Unit
Mounting on a DIN Rail
1
Align the claw at the bottom of the main body with the DIN rail. While pushing the main body in the direction of the arrow 1, slant it in the direction of the arrow 2.
2
To dismount the sensor, raise the main body in the direction of the arrow 3 while pushing the main body in the direction of the arrow 1.
Installation on a Wall (Main Unit Only)
Attach the unit to the optional mounting bracket (OP-73880), mount them together, and secure them with two M3 screws as shown in the illus­tration.
Connecting Multiple Amplifiers
Up to 16 sub units can be connected to one main unit.
1 Remove the protection cover on the side of
the main unit.
2 Install the amplifier one by one on the DIN rail.
3 Engage the two claws of the child unit with the
recesses on the main unit side until you hear a click sound.
4 Attach the end units (option: OP-26751) to the
both ends of the connected amplifiers in the same way as in step (2).
5 Sandwich the amplifiers between the end
units. Tighten the screws at the top (two screws x two units) with a Phillips screwdriver to fix the end units.
Connecting Fiber Unit
1 Open the dust cover in the direction
shown by arrow 1.
2
Move down the fiber lock lever in the direction shown by arrow 2.
3
Insert a fiber unit into the fiber insertion holes to a length of the fiber insertion sign (i.e., approximately 14 mm).
4
Move down the fiber lock lever in the direction shown by arrow 4.
Note
If a thin fiber unit is used, an adapter provided with the thin fiber unit will be required. Unless the right adapter is connected, the thin fiber unit will not detect targets correctly. (The adapter is supplied with the fiber unit.)
To connect the coaxial reflective type fiber unit to the amplifier, connect the single-core fiber to the transmitter side, and connect the multiple-core fiber to the receiver side.
Warning
• This product is used to detect targets. Do not apply the product to safety circuits for human protection.
• This product is not of explosion-proof construction. Do not use the products in places with flammable gas, liquid, or dust.
This product is a sensor of DC power supply type. Do not apply AC power. The product may explode or burn if an AC voltage is applied.
SEL
M
S E L
M
DSC
DSC
Operation status indicators
Digital monitor
Setting value (Displayed in green)
Current value (Displayed in red)
Dust cover
Fiber lock lever
Set button (SET)
DSC indicator
Manual button
Mode button
Power selection switch*1
Expansion protective cover
Expansion connector
Output selector
Cable*2
*1 When set to “M”, the power mode is fixed to Mega Turbo. *2 FS-V30 does not have the cable. M8 connector for FS-V31C(P)/32C(P)
Max. 100mA
0 VDC
12 to 24 VDC
(Control output)
Brown *1
Orange
Monitor output (1 to 5 V)*2
Blue *1
Black
Photoelectric sensor main circuit
Overcurrent
protection circuit
Protection
circuit
Load
5 to 40 VDC
Devices with 10 k input impedance min.
Photoelectric sensor main circuit
Max. 100mA
0 VDC
12 to 24 VDC
(Control output)
Brown *3
Blue *3
Black
Load
Overcurrent
protection circuit
0 VDC
12-24 VDC
5-40 VDC
1
*
4
Sensor main circuit
Overcurrent protection circuit
Load
3
*
DC3.3 V
3
*
2
(Short-circuit current 1 mA or less)
PLC, etc.
0 VDC
Sensor main circuit
123
4
Pin assignment
* FS-V31C only
1
*
3
*
4
0 VDC
12-24 VDC
Sensor main circuit
Overcurrent protection circuit
Load
1
*
2
(Short-circuit current 2 mA or less)
PLC, etc.
12-24 VDC
Sensor main circuit
* FS-V31CP only
123
4
Pin assignment
Connected pin No. Core wire cover color
q Brown
w White
e Blue
r Black
3
412
OP-73864 (cable length:2 m) OP-73865 (cable length:10 m)
Cable outer dia. Adapter Appearance
ø1.3
Adapter A
(OP-26500)
ø1.0
Adapter B
(OP-26501)
OP-73880
OP-26751 (a set of two)
Fiber insertion sign
Receiver
Transmitter
Single-core fiber
Multi-core fiber
96M1557
2
Making Sensitivity Settings
Two-point Calibration
In this mode, the PV used will be the mean value of two sensing values obtained with and without a workpiece.
1
Press the SET button without any workpiece placed in front of the fiber unit.
2
Place a workpiece placed in front of the fiber unit, and press the SET button.
If the sensitivity difference does not have enough room, “----” flashes for about two seconds after the calibration is complete. The set value is stored in memory even in that case.
Maximum Sensitivity Setting
Set the sensitivity without a workpiece in the case of the reflective type, and with a workpiece in the case of the through-beam or retro-reflective type.
Press the SET button for three seconds in the state as shown in the above figure. (Release the button when SET flashes.)
When setting the sensitivity, set the value slightly higher than the received light intensity.
Full Auto Calibration
In this mode, the PV will be set to the mean value of the maximum and minimum incident val­ues obtained within a certain period. Use this mode to detect moving workpieces.
1 Press the set button for a minimum of three seconds while the target
workpiece is passing the sensing area of the fiber unit.
• While the SET button is pressed, the sensitivity of the sensor will be set according to the incident values.
• After the setting is completed, the setting value is displayed on the digital monitor.
Positioning Calibration
1
Press the SET button without any workpiece placed in front of the fiber unit.
2 Place a workpiece on the position where you want to perform positioning.
Press the SET button for 3 seconds or longer until the display flashes.
Fine-adjusting Sensitivity
The setting value can be directly changed by pressing the manual button.
Percentage (%) Calibration
This is a calibration method that can set the setting value by percentage with ref­erence to the received light intensity at the time of sensitivity setting. For example, if the target value is set to –10P, the setting value is determined 10% lower than the received light intensity when the SET button is pressed.
1 When selecting the sensitivity setting method (page 4, No. 2), select the %
calibration, and set the target value of calibration.
2 Taking the desired light intensity as a reference (normally without a
workpiece), press the SET button.
* While the % calibration is in use, other calibrations (sensitivity setting) cannot
be used.
* With FS-V31C(P)/32C(P), by periodically performing external calibration from
PLC or other devices, stable detection can be performed even with a small sensitivity difference.
Output Selection
Either light-ON mode or dark-ON mode is selectable.
Dynamic Sensitivity Correction (DSC) Function
DSC automatically corrects the setting value according to the changes in the received light intensity when there is no workpiece (output OFF). This function is effective when the light intensity difference is small when judging whether or not there is a workpiece. At Detection mode selection (page 4, No.4), select “Dynamic sensitivity correction mode” beforehand.* How to set the sensitivity is the same as in the normal mode.
The DSC indicator illuminates when the DSC function is set.
* When Light ON is selected, the upper limit of the correctable range is twice as
much as the initial setting value. * The value is stored in memory even after the power is turned off. *
The DSC indicator flashes when the light intensity during output OFF greatly fluctuates
or the L/D ON selection is inappropriate. In such a case, check the setting again.
Edge Detection Mode
This mode detects the change in the received light intensity during a given period of time.
Filter Setting
Basically, leave this setting as its initial value. If the passage interval of workpieces is too short for the unit to respond, strengthen the level and try again. The selectable filter level differs depending on the power modes.
*HSP: HIGH SPEED As the number becomes smaller, the filter becomes stronger, which makes the unit difficult to respond to gradual changes in light intensity.
Making Sensitivity Settings
The sensitivity is set to maximum when the SET button is pressed quickly once. When the setting value is too low and the unit detects objects other than the work­piece, fine-adjust the setting value to a higher number.
Operation When Switching Outputs
When extension display (page 5, No.8) is set for the number of digits to be displayed for the received light intensity
1
Press the manual button quickly once, and check that the setting value flashes.
2
While the setting value is flashing, change the setting value with the Manual button.
DSC
DSC
When the setting is completed, the setting value is displayed.
Workpiece
DSC
3 sec or longer
"Reflective model"
"Through-beam model"
DSC
Workpiece
DSC
Workpiece
DSC
When the setting is completed, the setting value is displayed.
Head
Workpiece
SEL
M
DSC
Rising edge detection Detects the increase (rising edge) of the
received light intensity
Falling edge detection Detects the decrease (falling edge) of the
received light intensity
Filter level HSP* FINE
TURBO
SUPER ULTRA MEGA
Default state 589999
Setting range 1 to 5 4 to 8 5 to 9 6 to 9 8 to 9 9 only
Setting Operation
L-ON Normally OFF. Turns ON only when the light intensity changes.
D-ON Normally ON. Turns OFF only when the light intensity changes.
SEL
M
DSC
Press
Press 2 within five seconds after pressing 1.
1
2
SEL
M
When the area detection mode is selected, the selection options are NO and NC.
DSC
SEL
M
DSC
DSC indicator