Digital Fiberoptic Sensor
Fiber
Always insert fiber from the side with writing
Fiber cutter
(OP-87098)
(2)
(1)
Singlecore
Transmission
Reception
Multicore
Brown*1
Black (output 1)
White
*2
(output 2)
Pink
*2
Load
Load
10 to 30 VDC
0 V
Blue
*1
Brown*1
Black (output 1)
White
*2
(output 2)
Pink
*2
Load
Load
10 to 30 VDC
0 V
Blue
*1
FS-N40 Series
Instruction Manual
Read this manual before using the product
in order to achieve maximum performance.
Keep this manual in a safe place after reading it so that it can be used at any time.
For detailed FS-N40 Series setting methods and for details on the functions of the FS-N40
Series, see the “FS-N40 Series User's Manual”.
Symbols
The following symbols are used in this instruction manual to enable the recognition
of important information at a glance. Be sure to read these messages carefully.
It indicates a hazardous situation which, if not avoided, will result
DANGER
in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
WARNING
result in death or serious injury.
It indicates a hazardous situation which, if not avoided, could
CAUTION
result in minor or moderate injury.
It indicates a situation which, if not avoided, could result in product
NOTICE
damage as well as property damage.
2 Installation and Wiring
Mounting the Main Unit
Mounting the Main Unit on a DIN rail
1 Align the claw at the bottom of the main unit with the
DIN rail, as shown in the figure. While pushing the
main body in the direction of arrow 1, push down in
the direction of arrow 2.
2 To remove the sensor, raise the main body in the
direction of arrow 3 while pushing the main body in
the direction of arrow 1.
Installation on a wall (main unit only)
1 Attach the main unit to the optional mounting
adapter (OP-88245), and then insert M3 screws into
the two locations shown in the figure to secure the
main unit in place.
Connecting Multiple Amplifiers
Up to 16 expansion units can be connected to 1 main unit. However, each dual
output type will be treated as 2 expansion units.
When connecting to multiple amplifiers or when mounting main units
together, mount the units on a DIN rail installed on a metal surface.
•
Be sure to turn the power off before connecting multiple expansion units.
•
Do not touch the expansion connector.
1 Remove the protection covers from the main unit
and expansion unit(s).
(3)
(2)
(1)
1 Before Operation
Safety Precautions
•
This product is only intended to detect objects. Do not use this product for
the purpose of protecting a human body or a part of a human body.
•
This product is not intended for use as an explosion-proof product. Do not
DANGER
use this product in a hazardous location and/or potentially explosive
atmosphere.
•
WARNING
NOTICE
Precautions on Regulations and Standards
CE Marking
KEYENCE Corporation has confirmed, on the basis of the following specifications,
that this product complies with the essential requirements of the applicable EU
Directive(s). Be sure to consider the following specifications when using this
product in the member states of the European Union.
z EMC Directive, applicable standard: EN60947-5-2, Class A
Ensure that the cable length is 30 meters or less.
These specifications do not give any guarantee that the end-product with this
product incorporated complies with the essential requirements of the EMC
Directive. The manufacturer of the end-product is solely responsible for confirming
the compliance of the end-product itself according to the EMC Directive.
UL Certificate
This product is a UL/c-UL certified product.
• UL File No.: E301717
• Category: NRKH/NRKH7(NRKH2/NRKH8: FS-N42N(P))
• Enclosure Type 1 (based on UL50)
Be sure to consider the following specifications when using this product as a UL/
c-UL certified product.
• Use a power supply with Class 2 output defined in NFPA70 (NEC: National
Electrical Code).
• Connect the power supply, external input, and control output to a single power
supply with Class 2 output.
• Use OP-73864, OP-73865 or OP-85498 cable with FS-N41C when the field
wiring is required.
FCC Regulations
This product complies with the following regulations specified by the FCC.
• Applicable regulation FCC Part 15 Subpart B Class A
• This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interface, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
• FCC Caution
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Package Contents
• Main unit • Instruction manual
This is a direct current (DC) power supply type sensor. Application of an
alternating current may result in explosion or fire.
•
Use separate conduits for power lines and high-voltage lines. Use of a
common conduit may result in device malfunction due to noise or damage
to the sensor.
•
Always ground the frame ground terminal when using an off-the-shelf
switching regulator.
•
Do not use this product outdoors.
2 Install the amplifiers on the DIN rail one at a time.
3 Slide the main unit and expansion unit(s) together.
Mate the two claws of the expansion unit with the
recesses on the main unit side until a click is heard/
felt.
4 Attach the end units (optional, sold separately:
OP-26751) to the DIN rail on both sides of the
amplifiers in the same way as step (2).
5 Secure the amplifiers between the end units.
Tighten the screws from the top (two screws × two
units) with a Phillips screwdriver to fix the end
units in place.
Fiber Unit Installation
Using a fiber cutter
1 Insert the fiber into the cutter hole.
2 Bring down the blade in a single, swift
motion to cut the fiber.
(Do not use a hole that has already been
used.)
Connecting to the amplifier unit
1 Open the cover (1), and then lower the lever in the
direction indicated by (2).
2 Insert the fiber unit into the installation holes
(approximately 14 mm). (3)
3 Move the lever back in the direction indicated by
(4).
When installing a coaxial reflective fiber in
the main unit, install the single-core fiber in
the transmission installation hole and the
multi-core fiber in the reception installation
hole.
(4)
(2)
(3)
Wiring (Cable Type)
z FS-N41N/N42N/N43N/N44N z FS-N41P/N42P/N43P/N44P
*1 FS-N41N/N43N only
*2 FS-N43N/N44N only
*1 FS-N41P/N43P only
*2 FS-N43P/N44P only
1
(2)
(1)
(1)
E FS-N40 IM

Wiring (M8 Connector Type: FS-N41C)
FS-N41C supports "IO-Link: Specification V.1.1/COM2 (38.4 kbps)".
The setting file (IODD) can be downloaded from Keyence's web site
(http://www.keyence.com).
(1) Brown
Load
Load
10 to 30 VDC
0 V
(4) Black
(output 1)
(2) White
(output 2)
(3) Blue
(1) Brown
Load
10 to 30 VDC
0 V
(4) Black
(2) White
(3) Blue
(1) Brown
Load
10 to 30 VDC
0 V
(4) Black
(2) White
(3) Blue
Power select switch
*3
Standard <=> TERA fixed
Output indicator
*1
L/D ON setting status indicator
*2
MODE button
Setting
value
SET button
This button is used to
perform calibration.
Manual button
This button is used to
fine-tune the setting value.
ACT-R button
This button is used to set the
active receiver function.
Current value
(received light
intensity)
When turning on the sensor for the first time, or when the sensor has been
initialized, select the initial settings shown below.
Settings complete
Use to select PNP or NPN.
Use to select the I/O.
(OUT1 + OUT2/OUT1 + INPUT)
Use to select this item.
After completion, if these setting need to be
changed again, perform initialization (page 3).
PNP
OUT1 + OUT2
[
END
] WX
BacK
z Switching the output style (Light ON/Dark ON)
1 Press once.
2 Use to switch the output style.
3 Press three times.
z Switching the display language
1 Press twice.
2 Use to select the language.
3 Press twice.
z Fine-tuning the setting value (threshold)
Use to adjust the value. Hold down the button to make
adjustments more quickly.
Decrease the setting value.Increase the setting value.
z 2-point calibration (the most basic setting method)
1 Press with no object to detect present.
2 Press with an object to detect present.
This sets the setting value to the midpoint
between the received light intensities of
points 1 and 2. If “---” blinks for 2 seconds
on the display, the difference between the
received light intensities is small, and
detection may be unstable.
Object to
detect
Object
to detect
z Maximum sensitivity calibration
1 With the items arranged as shown in the figures on the left, hold down for 3 seconds
or more. When SET blinks, release this button.
The setting value is set slightly higher than
the received light intensity when the
setting was configured.
Object
to detect
Thrubeam model : With an obje ct to detect
present
Reflective model : With no object to detect
present
Select NPN or PNP and the function of I/O pin (2) during the initial settings.
z When using the sensor in PNP mode z When using the sensor in NPN mode
OUT1 + OUT2
OUT1 + INPUT
OUT1 + OUT2 OUT1 + INPUT
(1) Brown
(4) Black
(output 1)
(2) White
(output 2)
(3) Blue
Load
Load
10 to 30 VDC
0 V
The wire colors indicate the colors when using an OP-73864/73865 M8 connector cable (sold separately).
3 Basic Settings
Names and functions
*1 On dual output types (including the FS-N41C), the indicator operates
according to the output channel selected with the output channel selection
switch.
*2 On dual output types (including the FS-N41C), this becomes the output
indicator. It displays the current output status of channels 1 and 2.
*3 On dual output types (including the FS-N41C), this becomes the output
channel selection switch. It is not present on zero line types (FS-N40).
Initial settings (FS-N41C only)
Basic settings
Basic calibration methods
6(7
E FS-N40 IM
SET
2

4 Useful Functions
z Initialization
Initialize all the settings and return the sensor to its factory default state.
1 Hold down and for 3 seconds or more.
2 Press once.
3 Press once.
4 Press once.
z Key lock
Disable button operations.
1 Hold down and for 3 seconds or more.
Cancel: Use the same procedure.
z Saturation avoidance function
Use this function when the received light intensity does not change
from the maximum displayed value.
1 Press and simultaneously.
Cancel: Use the same procedure.
z Zero shift function
Use this function to change the received light intensity display to zero.
1 Press and simultaneously.
Cancel: Hold down and
for 3 seconds or more.
z Active receiver (ACT-R)
This function makes the fiber unit's receiver blink in green.
Operation when the sensor is shipped from the factory
When the sensor output is ON, the fiber unit's receiver lights in green.
(This is linked to the output.)
To change the normal lighting status of the receiver (change the
settings)
1 Press three times.
2 Use to select the status from those shown below.
Output Link: The receiver will light when the output is ON.
Reversed Op: The receiver will light when the output is OFF.
Always On: The receiver will be lit always.
Disable: The receiver will be off always.
3 Press twice to return to the normal status.
To force the receiver to blink in green (pairing mode)
1 Press once.
2 Press .
3 The light-receiving side blinks in green.
4 Press four times to return to the normal status.
To make it easy to perform optical-axis alignment (optical-axis
alignment assist mode)
1 Press twice.
2 Press to make the light-receiving side blink in green.
3 Move the tip of the fiber unit within the movable range.
The light-receiving side lights in green near the peak light intensity within the
range in which the tip moved.
Align the optical axis within the middle of the range in which the lightreceiving side lights.
4 When you finish the alignment, press three times.
The sensor returns to the normal status.
5 Specifications
Model
Cable/connector Cable M8 connector
Main unit/expansion unit Main unit
Number of control outputs 1 1 2 2 2
Number of external inputs - - 1 1 1
Light source LED Transmitter side: Red, four-element LED (wavel ength: 660 nm)
Control
output
External input Input time: 2 ms (ON)/20 ms (O FF) or longer
Unit expansion
(excluding the FS-N41C)
Protection circuit
Mutual interference
prevention
Power
supply
Ambient light Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less
Ambient temperature -20°C to +55°C (no freezi ng)
Vibration resistance 10 to 55 Hz; double amplitude 1.5 mm; 2 hours each for X, Y, and Z axes
Shock resistance 500 m/s2; 3 times each for X, Y, and Z axes
Case material Main unit and cover: polycarbonate
Weight Approx. 78 g Approx. 48 g Approx. 83 g Approx. 73 g Approx. 25 g Approx. 23 g
*1 IO-Link Specification V.1.1/COM2 (38.4 kbps) is support ed.
*2 Ensure the cable length is 30 m or less for the M8 connector type. In case of connecting with IO-Link, set it to 20 m or less.
*3 Output 2 and the external input are selectable.
*4 This counts as 1 output when connecting multiple units to the FS-MC8N/P, NU Series.
*5 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.
NPN output FS-N41N FS-N42N FS-N43N FS-N44N
PNP output FS-N41P FS-N42P FS-N43P FS-N44P
Expansion unit
Open-collector, 30 V or less
(when used as a solitary unit)/
20 mA (when used as an expansion unit)
NPN 1.4 V or less (output current: 10 mA or
2 V or less (output current: 10 to 100 mA)
PNP 1.6 V or less (output cu rrent: 10 mA or less)/
2.2 V or less (output current: 10 to 100 mA)
Up to 16 units (17 units conn ected in total including the main unit).
However, each two output type will be treated as two expansion units.
10 to 30 VDC (including 10% ripple (P-P) or less), class 2 or LPS
During normal opera tion: 870 mW or less
(34 mA or less at 24 V/62 mA or l ess at 12 V)
ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V)
ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)
One output type (FS-N41 P/N42P) and FS-N41C
During normal opera tion: 910 mW or less
(36 mA or less at 24 V/65 mA or l ess at 12 V)
ECO ON: 840 mW or less (33 mA or less at 24 V/60 mA or less at 12 V)
ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)
During normal opera tion: 990 mW or less
(39 mA or less at 24 V/72 mA or l ess at 12 V)
ECO ON: 920 mW or less (36 mA or less at 24 V/66 mA or less at 12 V)
ECO FULL: 830 mW or less (33 mA or less at 24 V/59 mA or less at 12 V)
Residual voltage
Power supply
voltage
NPN
FS-N40
*7
PNP
FS-N41C
Power consumption
(The mutual interference prevention values are twice those shown here when Double is set.)
100 mA or less per output, 100 mA or less total for 2 outputs
Protection against reverse power connection, output overcurrent, output surge,
S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units
The response times are listed
on the following page.
(selectable output )
Main unit
Expansion unit
less)/
and reverse output connection
Two output type (FS-N43P/N44P)
*8
FS-N41C
Main unit
*5
ACT
-R
ACT
-R
ACT
-R
*6 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.
*7 The load current is excluded. The power consumption including the load when the maximum number of units are connected
is 38 W max.
*8 When expanded by 1 to 2 units: -20°C to +55°C. When expanded by 3 to 10 units: -20°C to +50°C.
When expanded by 11 to 16 uni ts: -20°C to +45°C. When using 2 outputs, 1 unit is counted as 2 units.
Note that all the temperature prescriptions assume that the sensor has been mounted on a DIN rail installed on a metal
*1
FS-N40
*2
-
Expansion unit
*3
*3
*4
None
-
-
-
*6
surface.
Exercise special care when installing the product in an airtight space.
WARRANTIES AND DISCLAIMERS
(1) KEYENCE warrants the Products to be free of defects in material s and workmanship for a period of one (1)
year from the date of shipment. If any models or samples were shown to Buyer, such models or samp les were
used merely to illustrate the general type and quality of the Products and not to represent that the Products
would necessarily conform to said mod els or samples. Any Products found to be defective must be shipped to
KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon
examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace
at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any
action of Buyer, including but not limited to improper installation, improper inter facing, improper repair,
unauthorized modification, misapplication and mishandling, s uch as exposure to excessive current, heat,
coldness, moisture, vibration or outdoors air. Components which wear are not warranted.
(2) KEYE NCE is pleased to offer suggestions on the use of its various Products. They are only suggestions, and i t
is Buyer's responsibility to ascertain the fitness of the Produc ts for Buyer’s intended use. KEYENCE will not be
responsible for any damages that may result from the use of the Products.
(3) The Products and any samples ("Products/Samples") s upplied to Buyer are not to be used internally in
humans, for human transportation, as safety devices or fail-safe systems, unless their written speci fications
state otherwise. Should any Products/Samples be used in such a manner or misused in any way, KEYENCE
assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE har mless from
any liability or damage whatsoever arising out of any misuse of the Products/Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO OTHER
WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,
WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR
ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL
DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE,
BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF
PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES
OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR
INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS
ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST
BUYER. In some jurisdictions, som e of the foregoing warranty disclaimers or damage limitations may not apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or deli vered to a third party, Buyer must provide
such third party with a copy of this docu ment, all specifications, manuals, catalogs, leaflets and written
information provided to Buyer pertaining to the Pr oducts/Samples.
E 1101-3
3
E FS-N40 IM

Copyright (c) 2017 KEYENCE CORPORATION. All rights reserved.
14746E 1127-2a 96M14746 Printed in Japan
6 Detailed Settings
*3
Hold down for 3 seconds or more to enter the settings menu. Then, press
to change the item and press to switch the setting value.
Press + when an item is being set to return to the previous item.
Press to select the value.
Select from eight power modes. The initial setting is FINE.
Mode S-HSPD*1HSPD FINE TURBO
Response time 23 μs 50 μs250 μs 500 μs
Maximum displayable light intensity 9999
Mode SUPER ULTRA MEGA TERA
Response time 1 ms 4 ms 16 ms 64 ms
Maximum displayable light intensity 9999 99999
*2
Press to select the value.
Press to select the value.
Settings complete
End ADVANCE
Press to select the value.
Select from the following operation modes.
• Standard • Preset • Percent
• Zeroshift • Area detection • Area % Mode
• DATUM • Rising edge • Falling edge
Press to select the value.
Press to select the value.
This can only be used on types that support an external input. It is possible to
select from the following values.
• OFF • External Set • Zero shift
• Reset • LED OFF • Pause
• Sleep
When connected to the multi-output unit FS-MC8N/P or the communication unit
NU Series, this setting can be configured on types that do not support an
external input.
Press to select the value.
Press to select the value.
Press to select the value.
If Limit Detection is set to ON, a notification of a drop in light intensity is shown on the
display when the light intensity drops due to factors such as dirt.
With dual output types, it is also possible to output alarms to an external device.
When connected to the multi-output unit FS-MC8N/P, it is possible to output alarms from
the “common output” of the FS-MC8N/P even for types that do not support the alarm
output.
Press to select the value.
Press to select the value.
Press to
select the value.
Press to select the value.
Select from English (initial setting), Japanese, Chinese, and German.
Press to
select the value.
Press to
select the value.
Press to
select the value.
Press
to select the
value.
Press to
select the value.
Press to
select the value.
Press to
select the value.
Settings complete
Hold down for 3 seconds or more to enter setup mode.
When using a dual output type, if the output channel selection switch is
set to the "2" side, output 2 can be set.
*1 When S-HSPD is selected fo r Power Modes
Output 2 of dual output types is fixed to OFF.
IO-Link communication cannot be used (FS-N41C).
*2 This is 65535 when connected to an NU Series unit.
*3 When S-HSPD is selected fo r Power Modes
Area detection, Area % Mode, DATUM, Rising edge, or Falling edge cannot be selected.
*4 This cannot be used when S-HSPD is selected for Power Modes.
*5 This cannot be used when S-HSPD or HSPD is selected for Power Modes.
*6 When S-HSPD is selected for Power Modes, FULL cannot be selected for the ECO function.
The IO-Link communication cannot be used when FULL is selected for ECO (FS-N4 1C).
*7 This item is not displayed o n the FS-N41C.
*8 This item is only displayed on the FS-N41C.
A Power Modes
B Switch L-on/D-on
C Display Bar
[END]
W X
ADVANCE
D Detection Mode
E Output timer
F Ext. Input
G Saturate Cancel
H Attenuation
J Limit Detection
K Auto Power
L Hysteresis
MLanguage
N Flip Display
O Sub Display
PACT-R
Q Brightness
RECO
S Initialize
T
Custom Setting
U Interference
a
Second Output
b
Switch L-On/D-On
c
Output timer 2
V
Key Lock Method
W Display Gain
X IO-Link Mode
Y
IO Data Format
Z I/O Selection
*4
Press to select the value.
*4
Press to select the value.
*6
Press
to select the
value.
*5
*7
Press to
select the value.
Press to
select the value.
Press to
select the value.
Press
to select the
value.
*5
Press
to select the
value.
*8
Press
to select the
value.
*8
Press
to select the
value.
*8
IZero Shift
Output 2 setting
Settings complete
• Light ON • Dark ON
• OFF • ON
END
END