When the mechanism made an irregular action, follow the chart below for initializing.
Commence initializing
Switch ON MTR
(Wait for 1 sec.)
X-W320
No
Yes
Switch ON
"PLAY" SW
Yes
Switch ON SOL
(50 msec.)
Wait for 1 sec.
Switch ON
"PLAY" SW
No
Switch OFF MTR
Complete initializing
3. Test mode
3-1 Setting method
While pressing the STOP key (A DECK), turn the power switch ON.
After turned the power ON, all lights are illuminated for 1.5 seconds and return to normal display with
T indication.
3-2 Cancellation
Turn the power switch OFF.
3-3 Contents of the test mode
1) (4 / 8 / 12) seconds recording.
KEYST(SECONDS)
DECK B STOP 7 + DECK B REC ¶4
DECK B STOP 7 + DECK B PAUSE 88
DECK B STOP 7 + DOLBY NR12
REC
T(SEC)
PLAY
RWD
T
5
X-W320
RECINPLAY
OUT
LINE
R
L
SYSTEM
CONTROL
AC 110 120V
AC 220 240V
Oscilloscope
AC voltmeter
Frequency counter
AC voltmeter
AG
{
(A)(B)
1
2
REC/PB UNIT
TP201(L)
TP202(R)
GND
R404
To be added
a 1kΩ.
R524
Q404
VR502
VR501
(A DECK)
(B DECK)
1KΩ
1KΩ
ADJUSTMENT
No.ITEM
INPUT
SETTINGS
OUTPUT
SETTINGS
CASSETTE TAPE
DECK SETTINGS
ALIGNMENT
POINTS
ALIGN FOR
Unless otherwise specified : each ; switch should be set as follows :
TAPE : NORMAL, DOLBY : OFF, INPUT : LINE0dBs=0.775V
I.Cassette mechanism section (REC/PB head adjustment)
Demagnetize the REC /PB
head by head eraser.
Clean the REC/PB head,
erase head capstan and
pinch roller with a cotton
swab immersed in alcohol.
Maximize the output and
adjust so that the Lissajous figure nears a line
slanted 45°.
Demagnetization
[1]
and cleaning
REC/PB head
[2]
azimuth
––
MTT-114,
TCC-153
SCC-1727
Power OFF, demagnetization,
cleaning play
(B)PLAY
REC/PB
head, erase
head. cap-
stan, pinch
roller
Azimuth
adjustment
screw.
II. Printed circuit board adjustment. Note : First perform the high-speed adjustment.
1. Playback a TEST TAPE
<1>
Tape
speed
(A DECK)
Tape
speed
HIGH
NOR.3. Disconnect a 1kΩ.NOR. VR402
MTT-111
TCC-100
SCC-1727
HIGH
3kHz, -4dB
TP201
or
TP202
(B)
2. Connect collector (Q404)/
R404 to GND via1kΩ.
1. Playback a TEST TAPE.
2. Connect collector (Q508)
/R524 to GND via 1kΩ.
HIGH VR401
Adjust so that the frequency is 6kHz(HIGH), 3kHz
(NOR) at the tape center.
HIGH VR501
(B DECK)
NOR.3. Disconnect a 1kΩ.NOR. VR502
Playback level
<2>
(A DECK)
Playback level
TCC-130PLAY
(B DECK)
<3>MPX filter19kHz, -20dB
REC LEVEL 0dB
DOLBY B MODE
VR403(L)
VR404(R)
VR503(L)
VR504(R)
L 203(L)
L 204(R)
775mV
775mV ±2dB
• Adjust the REC LEVEL volume so that the recording
monitor output becomes
15mV at 1kHz.
• Record 1kHz and 10kHz alternately.
VR101(L)
VR102(R)
15mV ±1dB
<5>Bias current
1kHz,15mV
10kHz,15mV
TP201(L)
TP202(R)
(B)
• Rewind and playback recorded signal.
• Adjust the REC LEVEL vol-
<4>Recording level1kHz, 200mV
ume so that the recording
monitor output becomes
200mv at 1kHz.
• Record 1kHz.
• Rewind and playback record-
VR201(L)
VR202(R)
Adjust the variable resistors so that a playback
level of 200mV ±0.5dB is
obtained.
ed signal.
FIG.
(a)
SYSTEM CONNECTIONS(a) AZIMUTH ADJUSTMENT
SCREW
6
TAPE SPEED(HIGH)
TEST POINT