CD RECEIVER
KDC-225/MR
KDC-2025
SERVICE MANUAL
Panel assy
KDC-225 (A64-3172-02)
D
LOU
AUD
AUTO
AME
OFF
Front glass
KDC-225 (B10-4465-01)
© 2003-12 PRINTED IN JAPAN
B53-0112-00 (N) 764
CD mechanism extension cord (24PIN) : W05-0934-00
+
C.S.
SCRL
-
M.RDM
SCAN
RDM REP
CLK ADJ
DC cord
(E30-6322-05)
(E30-6323-05)
Panel assy
KDC-225MR (A64-3361-02)
D
LOU
AUD
AUTO
AME
Panel assy
KDC-2025 (A64-3305-02)
D
LOU
AUD
AUTO
AME
* Escutcheon
(B07-3097-02)
(B07-3098-02)
Front glass
KDC-225MR (B10-4559-01)
OFF
Front glass
KDC-2025 (B10-4548-01)
OFF
Mounting hardware assy
(J21-9716-03)
SCAN
SCAN
RDM REP
RDM REP
Lever
(D10-4589-04) x 2
M.RDM
M.RDM
CRSC
DISP ADJ
CRSC
CLK ADJ
-
-
Screw
(N84-4016-46)
+
+
Plastic cabinet assy
(A02-1486-13)
Screw set
* Not supplied
(N99-1719-05)
* Depends on model. Refer to the parts list.
* Remote controller assy
(A70-2040-05) : RC-505
TDF PANEL INFORMATION
MODEL PARTS NO. PANEL NAME
KDC-225 Y33-1940-60 TDF-42D
KDC-225MR Y33-1940-62 TDF-42DMR
KDC-2025 Y33-1940-61 TDF-42DB
KDC-225/225MR/2025
COMPONENTS DESCRIPTION
● SWITCH UNIT (X16-2640-11/12)
Ref. No. Application / Function Operation / Condition / Compatibility
IC1 LCD driver Drive for LCD unit
IC2 Remote control IC Receiving for the remote control unit
Q1 KEY scan detector key scan start at base gose “L”.
● ELECTRIC UNIT (X25-9980-11/12/21)
Ref. No. Application / Function Operation / Condition / Compatibility
IC1 System microcomputer
IC2 Electronic volume & N.C.MPX Control for source selector, volume & tone, and FM multiplex detector.
IC3 Power supply IC
Control for TUNER unit, CD mechanism, volume & tone, LCD driver and external CD changer unit
Power supply for the units (Bu5V, Audio8V, FM+B, AM+B, P-con and ANT-con)
SW1 OUT
1.5~3.0V Audio ON
3.5~5.0V Audio P-con ON
7.0V~ Audio P-con, P-ant ON
SW2 OUT
2.0~3.0V Illumination, FM ON
4.0V~ Illumination, AM ON
IC4 Audio power amp IC Amplifier for audio signal to derive for 4channel speakers (50W maximum for each channel)
IC6 Muting control IC Control for timing for mute
IC8 Reset IC When detection voltage goes below 3.5V or less Reset IC output change to “L” signal
Q1 Serge detection
Q2 Backup detection
Q3 ACC detection When ACC voltage supplied output is “L”
Q4 SW 5V When base voltage is “L” Q4 is ON
Q21,24 AVR Servo regulator
Q22 SW Servo SW
Q151 DSI driver
Q201 Buffer amp Noise buffer amp
Q252
Q350 Pre & NF mute SW When base voltage to “L”, drive to pre & NF mute SW (Q351)
Q351 Pre mute SW When base voltage to “H”, muting to the pre Lch or NF Lch line
Q352 Pre mute SW When base voltage to “H”, muting to the pre Rch or NF Rch line
Q401 DSI illumination SW When base voltage to “H”, DSI illumination is light up.
For surge measure of audio power IC
When backup voltage become more than 24V output is “L” (momentary power down) /
When backup voltage become less than 24V output is “H”
When BU voltage supplied output is “L” /
When BU voltage not supplied or momentary power down is detected output is “H”
When base voltage level is “L” DSI LED is light up / When base voltage level is “H” DSI LED
turns off / When panel assy is pull off, cut off the supply to panel 5V AVR.
When base voltage to “L”, for control to power IC function (STAND BY)
3