https://harrissupplyind.com - To Order Parts Call 608-268-8080
Instructions for use and parts list
Kent/Euroclean MODEL 56649981
06/03 revised 8/08 Form Number 56041563
Page 2
INTRODUCTION
https://harrissupplyind.com - To Order Parts Call 608-268-8080
This manual will help you get the most from your Kent/Euroclean RainmakerTM H. Read thoroughly
before operating the machine.
NOTE: Bold numbers in parenthesis indicate an item illustrated on page 7.
This product is intended for commercial use only.
PARTS AND SERVICE
Repairs, when required, should be performed by your authorized Kent/Euroclean Service Center, who
employs factory-trained service personnel, and maintains an inventory of Kent/Euroclean original
replacement parts and accessories.
Call the Kent/Euroclean DEALER named below for parts or service. Please specify the Model and
Serial Number when discussing your machine.
(Dealer, affix service sticker here)
NAME PLATE
The Model and Serial Number of your machine are shown on the nameplate in the machine. This
information is needed when ordering repair parts for the machine. Use the space below to note the
Model and Serial Number of your machine for future reference.
MODEL : ________________________________________
SERIAL NUMBER : _____________________________________
UNCRATING
When the machine is delivered, carefully inspect the shipping carton and the machine for damage. If
damage is evident, save the shipping carton so that it can be inspected. Contact Kent/Euroclean
Customer Service Department immediately to file a freight damage claim.
DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ THIS SECTION.
IMPROPER USE WILL VOID THE WARRANTY.
• Always use a defoamer when foaming occurs to prevent vacuum motor damage.
• Never use water above 140° F (60°C).
• Do not store outdoors. Avoid extremes in temperature.
• Do not let the pump run dry. Turn the pump off and refill that tank when cleaning solution
gets low.
• Use approved chemicals only. All chemicals should be mixed thoroughly. Liquid chemicals
are recommended to prevent powder buildups. A pH between 6 and 9 is recommended.
The use of high alkaline detergents or strong acids will accelerate the wear of the pump
and seals, and will void the warranty.
• All extension cords must have a rating of at least 12/3 (#12 cord). Extension cords should
be no longer than 50 feet. Replace the plug immediately if the ground prong becomes
damaged or is broken off.
2 - FORM NO. 56041563 / Rainmaker™ H
Page 3
IMPORTANT SAFETY INSTRUCTIONS
https://harrissupplyind.com - To Order Parts Call 608-268-8080
This machine is only suitable for commercial use, for example in hotels, schools, hospitals,
factories, shops and offices other than normal residential housekeeping purposes.
When using an electrical appliance, basic precautions should always be followed, including
the following:
Read all instructions before using this appliance.
WARNING!
To reduce the risk of fire, electric shock, or injury:
•Do not leave the appliance when it is plugged in. Unplug the unit from the outlet when not in
use and before servicing.
•To avoid electric shock, do not expose to rain. Store indoors.
•Do not allow to be used as a toy. Close attention is necessary when used near children.
•Use only as described in this manual. Use only the manufacturer’s recommended attachments.
•Do not use with damaged cord or plug. If the appliance is not working as it should be, has
been dropped, damaged, left outdoors or dropped into water, return it to a service center.
•Do not pull or carry by the cord, use the cord as a handle, close a door on the cord, or pull the
cord around sharp edges or corners. Do not run the appliance over the cord. Keep the cord
away from heated surfaces.
•Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.
•Do not handle the plug, cord or appliance with wet hands.
•Do not put any object into openings. Do not use with any opening blocked; keep free of dust,
lint, hair, and anything that may reduce air flow.
•Keep loose clothing, hair, fingers, and all parts of body away from openings and moving parts.
•Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes,
or any health endangering dusts.
•Turn off all controls before unplugging.
•Use extra care when cleaning on stairs.
•Do not use to pick up flammable or combustible liquids such as gasoline or use in areas
where they may be present.
•Connect to a properly grounded outlet only. See Grounding Instructions.
•Liquid ejected at the spray nozzle could be dangerous as a result of its temperature, pressure
or chemical content.
SAVE THESE INSTRUCTIONS
FORM NO.56041563 / Rainmaker™ H - 3
Page 4
CONSIGNES DE SECURITE IMPORTANTES
https://harrissupplyind.com - To Order Parts Call 608-268-8080
Cette machine ne convient qu´à un usage industriel, par exemple dans des hôtels, écoles,
hôpitaux, usines, boutiques et bureaux et autres à l´exclusion de tout usage de maintenance
résidentielle normale.
L’utilisation d’un appareil électrique demande certaines précautions
LIRE TOUTES LES INSTRUCTIONS AVANT DE FAIRE FONCTIONNER (CET APPAREIL)
:
AVERTISSEMENT!
Pour réduire les risques d’incendie, de choc électrique ou de blessure:
•Ne pas laisser l’appareil sans surveillance lorsqu’il est branché. Débrancher lorsque l’appareil
n’est pas utilisé et avant l’entretien.
•Pour réduire les risques de choc électrique, utiliser à l’intérieur seulement.
•Ne pas permettre aux enfants de jouer avec l’appareil. Une attention particulière est
nécessaire lorsque l’appareil est utilisé par des enfants ou à proximité de ces derniers.
•N’utiliser que conformément à cette notice avec les accessoires recommandés par le fabricant.
•Ne pas utiliser si le cordon ou la fiche est endommagé. Retourner l’appareil à un atelier de
réparation s’il ne fonctionne pas bien, s’il est tombé ou s’il a été endommagé, oublié à l’extérieur
ou immergé.
•Ne pas tirer soulever ou traîner l’appareil par le cordon. Ne pas utiliser le cordon comme une
poignée, le coincer dans l’embrasure d’une porte ou l’appuyer contre des arêtes vives ou des
coins. Ne pas faire rouler l’appareil sur le cordon. Garder le cordon à l’écart des surfaces
chaudes.
•Ne pas débrancher en tirant sur le cordon. Tirer plutôt la fiche.
•Ne pas toucher la fiche ou l’appareil lorsque vos mains sont humides.
•N’insérer aucun objet dans les ouvertures. Ne pas utiliser l’appareil lorsqu’une ouverture est
bloquée. S’assurer que de la poussière, de la peluche, des cheveux ou d’autres matières ne
réduisent pas le débit d’air.
•Maintenir les cheveux, les vêtements amples, les doigts et toutes les parties du corps à l’écart des
ouvertures et des pièces mobiles.
•Ne pas aspirer de matières en combustion ou qui dégagent de la fumée, comme des cigarettes,
des allumettes ou des cendres chaudes.
•Mettre toutes les commandes à la position ARRÊT avant de débrancher l’appareil.
•User de prudence lors du nettoyage des escaliers.
•Ne pas aspirer des liquides inflammables or combustibles, comme de l’essence, et ne pas faire
fonctionner dans des endroits ou peuvent se trouver de tels liquides.
•Ne brancher qu’à une prise de courant avec mise à la terre. Voir les instructions visant la mise à
la terre.
•Le liquide qui sort de l’embout de vaporisation peut s’avérer dangereux en raison de sa
température, de sa pression ou du produit chimique qu’il contient.
CONSERVER CES INSTRUCTIONS
4 - FORM NO. 56041563 / Rainmaker™ H
Page 5
120VAC GROUNDING INSTRUCTIONS
https://harrissupplyind.com - To Order Parts Call 608-268-8080
This appliance must be grounded. If it should electrically malfunction, grounding provides a path of
least resistance for electric current to reduce the risk of electric shock. This appliance is equipped
with a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded in accordance with all local codes
and ordinances.
DANGER!
Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if you are in doubt as to whether the outlet is
properly grounded. Do not modify the plug provided with the appliance. If it will not fit the outlet, have
a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the
plug illustrated in Figure 1 below. A temporary adapter illustrated in Figures 2 and 3 may be used to
connect this plug to a 2-pole receptacle as shown in Figure 2 if a properly grounded outlet is not
available. The temporary adapter should be used only until a properly grounded outlet (Figure 1) can
be installed by a qualified electrician. The green-colored rigid ear, tab, or the like extending from the
adapter must be connected to a permanent ground such as a properly grounded outlet box cover.
Whenever the adapter is used, it must be held in place by a metal screw. Grounding adapters are not
approved for use in Canada.
Replace the plug if the grounding pin is damaged or broken.
The Green (or Green/Yellow) wire in the cord is the grounding wire. When replacing a plug, this wire
must be attached to the grounding pin only.
Extension cords connected to this machine should be 12 gauge, three-wire cords with three-prong
plugs and outlets. DO NOT use extension cords more than 50 feet (15 m) long.
PLEASE NOTE: FOR NORTH AMERICA ONLY
FORM NO.56041563 / Rainmaker™ H - 5
Page 6
INSTRUCTIONS VISANT LA MISE À LA TERRE (120VAC)
https://harrissupplyind.com - To Order Parts Call 608-268-8080
Cet appareil doit être mis à la terre. En cas de défaillance ou de panne éventuelles, la mise a la terre
fournit au courant un chemin de moindre résistance qui réduit le risque de choc électrique. Cet
appareil est pourvu d’un cordon muni d’un conducteur de terre et d’une fiche avec broche de terre.
La fiche doit être branchée dans une prise appropriee correctement installée et mise à la terre
conformément aux règlements et ordonnances municipaux.
AVERTISSEMENT !
Un conducteur de terre mal raccordé peut entraîner un risque de choc électrique. Consulter un
électricien ou un technicien d’entretien qualifié si vous n’êtes pas certain que la prise est correctement
mise à la terre. Ne pas modifier la fiche fournie avec l’appareil - si elle ne peut être insérée dans la
prise, faire installer une prise adéquate par un électricien qualifié.
Cet appareil est destiné à un circuit de 120 V et est muni d’une fiche de terre semblable à celle
illustrée par le croquis 1. Un adaptateur temporaire semblable à celui illustré par le croquis 2 et C
peut être utilisé pour brancher cette fiche à une prise bipolaire comme l’illustre le croquis 2 si une
prise avec mise à la terre n’est pas disponible. L’adaptateur temporaire devrait etre utilisé seulement
jusqu’à ce qu’une prise avec mise à la terre soit installée par un électricien qualifié. L’oreille rigide ou
le crochet ou autre dispositif semblable, de couleur verte, prolongeant l’adaptateur doit Iêtre raccordé
à un élément correctement mis à la terre comme le couvercle d’une boîte de sortie mise à la terre.
L’adaptateur doit être fixé par une vis métallique. Note: Au Canada, I’utilisation d’un adaptateur
temporaire n’est pas autorisée par le Code canadien de l’électricité.
Remplacez la prise si la prise de terre est abîmée ou cassée.
Le fil Vert (ou Vert/Jaune) dans la ganse est le fil de terre. Lors du remplacement d´une prise, ce fil
doit être raccordé à la prise de terre uniquement.
Les ralonges connectées à cette machine doivent avoir 12 mesures, trois ganses de fil ayant trois
fiches masculines féminines tree-prong plugs and outlets. N´UTILISEZ PAS de ralonge de plus de
15 m (50 pieds) de long.
VEUILLEZ NOTER: CES INSTRUCTIONS CONCERNENT UNIQUEMENT L’AMÉRIQUE DU
NORD
6 - FORM NO. 56041563 / Rainmaker™ H
Page 7
KNOW YOUR MACHINE
https://harrissupplyind.com - To Order Parts Call 608-268-8080
1
5
3
4
6
9
2
8
7
KNOW YOUR MACHINE DESCRIPTIONS
Operator Handle (1) - Operator holds this to move the machine from one location to another.
Lift Handle (2) - Operator grasps this handle when lifting the machine.
Solution Tank Lid (3) - Fill Solution Tank here with warm water and chemicals.
Recovery Tank Lid (4) - The Recovery Tank can be flushed out by running clean water into this
opening with the Recovery Tank Drain Hose open. The vacuum float Shut-OFF can also be
accessed through this opening for maintenance.
Switch Plate (5) - The switches that operate the motors and the heater are located here, as well
as indicator lights for the heater.
Vacuum Hose Connector (6) - This is where the vacuum hose attaches to the machine.
Solution Hose Connector (7) - This is where the solution hose attaches to the machine.
Latches (8) - These latches can be opened if the base compartment needs to be accessed. The
latches are normally closed to keep the machine sections held together tightly.
Drain Gate (9) - This gate is opened to allow the dirty recovered water to empty.
FORM NO.56041563 / Rainmaker™ H - 7
Page 8
SWITCH PLATE DESCRIPTIONS
https://harrissupplyind.com - To Order Parts Call 608-268-8080
Locator Light (1) - This green light will turn on when the two power cords are plugged into separate
circuits. Separate circuits are defined as outlets fed by circuit breakers on opposite sides of the
circuit breaker panel. This feature helps to prevent blown breakers. When the locator light (1) turns
on, the heat exchanger will automatically turn on. If you can not get the locator light to turn on, use
the Heat Switch (2) to turn the heat exchanger on.
Heat Switch (2) - This rocker switch turns the heat exchanger on and off, when the Locator light (1)
is not on. The switch will light when ON.
Mode Light (3) - This indicator light will turn on while the heat exchanger is actively heating. It will
turn off when the heater has reached operating temperature. Normally, this light will be on most of
the time as you do your job, but it may go out if you stop cleaning to move furniture or to empty or fill
the tanks.
Vacuum 1 Switch (4) - This switch turns one vacuum on and off. The switch will light when ON.
When operating with only one vacuum -- as when cleaning delicate fabric -- use Vacuum 1. When
cleaning carpet, use both Vacuum 1 and Vacuum 2 (5).
Vacuum 2 Switch (5) - This switch turns the second vacuum on and off. The switch will light when
ON. Use this switch when you want maximum vacuum lift. The CFM of both motors is the same as
it is for one motor alone, since the vacuums are operated in parallel; however, the vacuum lift
doubles when both vacuums are running.
Pump Switch (6) - This switch turns the pump on and off. The switch will light when ON.
The pump in this machine is a “demand” style pump. This means the pump only runs when you are
actually spraying. Once spraying stops, the pump stops running.
➀➀
➀
➀➀
➂➂
➂
➂➂
8 - FORM NO. 56041563 / Rainmaker™ H
212° F
➁➁
➁
➁➁
➃➃
➃
➃➃
O
II
O
➄➄
➄
➄➄
➅➅
➅
➅➅
OO
I
I
Page 9
MACHINE WIRING
https://harrissupplyind.com - To Order Parts Call 608-268-8080
White
115V
Power
Cord #1
∼
Neutral
Line
Green
Black
Black
SW
SW
SW
VAC 1
White
VAC 2
PUMP
White
FAN
115V
Power
Cord #2
∼
Black
Green
Black
Black
“LOCATOR”
•
LIGHT
P3
Dual Cord
Sensor Board
P1
P2
P5
White
“MODE”
LIGHT
Black
P4
P7
P6
Thermostat
White
•
Black
White
Thermal
Fuse
Black
∼
HEAT
EXCHANGER
FORM NO.56041563 / Rainmaker™ H - 9
Page 10
OPERATION
https://harrissupplyind.com - To Order Parts Call 608-268-8080
1Inspect the machine, hoses, and cleaning tools for cleanliness and completeness.
2Fill the solution tank with warm water. Using warm water may be a benefit in cleaning
effectiveness, but do not use hot water (above 140°F / 60°C) in the tank. Add liquid cleaning
solution with a pH of between 6 and 9.
3Plug in the power cords. Do not connect both cords to the same outlet; the circuit locator
light on the switch plate should light up. If the locator light does not come on, try different
outlets until it does. If you are certain the cords are on separate circuits, turn the heat
switch on. CAUTION: using the heat switch when the cords are on the same circuit may
cause the breaker to trip. NOTE: the cord with the red sleeve powers the heat exchanger.
4Attach the spray hose to the solution quick disconnect and the vacuum hose to the hose
barb on the recovery tank. Attach the other ends of the hoses to the cleaning tool.
5Turn the pump on and spray from the tool to make sure everything is working, and to fill the
heat exchanger with water. NOTE: the pump has a built in pressure switch; the pump only
runs when you are spraying.
6Allow the heat exchanger two minutes to reach operating temperature.
7Turn the pump on. Turn the vacuums on.
8Begin cleaning using the correct hoses and tool.
9Use defoamer in the recovery tank any time foaming occurs.
10 Monitor water level in the solution tank. Do not let the pump run dry.
11 When the solution tank gets low, turn off the pump, fill the solution tank, empty and clean the
recovery tank.
12 When finished with the job, remove any unused solution from the solution tank, and run a
few gallons of clean water through the system.
BALL FLOAT VACUUM SHUT-OFF
Prior to using the machine, always check that the float filter is clean and the ball can travel freely.
When the recovery tank is full, the ball float will rise and will shut off the vacuum flow to prevent
any more water from entering the tank. Turn off the vacuum, and empty the recovery tank.
NOTE: if foam is present, or if the ball float is prevented from rising, the float will not be able to
stop the air flow, and the tank may over fill.
CAUTION!
To avoid vacuum motor damage, always make sure the float filter is clean and the ball can travel
freely prior to using the machine. And always use a defoamer when foaming occurs.
ELECTRIC CIRCUIT LOCATOR
This unique, patented system is operated by a solid state circuit. It will inform the operator when
the two cords are plugged into separate circuits by turning the circuit locator light (1) on. This
helps to prevent tripping circuit breakers.
NOTE: if the circuit locator light does not illuminate when the cords are plugged in, then both
cords are on the same circuit. Try other outlets with one of the cords until you get the locator light
to come on.
CAUTION: if the Heat switch (2) is turned on when both cords are on the same circuit, the
breaker will trip.
10 - FORM NO. 56041563 / Rainmaker™ H
Page 11
USE AND MAINTENANCE
https://harrissupplyind.com - To Order Parts Call 608-268-8080
1Use only liquid chemicals with a pH between 6 and 9 at the recommended mix ratios. Improper
chemicals, or improperly mixed chemicals, can cause possible damage to the pump, seals, and
other components.
2Turn the pump “off” when the solution tank is low on fluid. Do not let the pump run dry.
3Regularly clean any mineral or chemical deposits in the heat exchanger, lines and pump with a
mild acid descaler. Rinse the descaler out of the machine with a few gallons of clear water.
4Prior to each job, inspect, and clean if needed, the solution filter, the recovery tank float filter,
and the drain hose.
5Make sure the airways are not blocked before each use.
6Inspect the carbon brushes on the vacuum motors once a year. Replace if worn down.
7Clean the Recovery Tank daily. Clean the body and wheels as needed.
8Keep the machine from extremes in temperatures.
MAINTENANCE SCHEDULE
PMUP&SENILHSULF
RETLIFTAOLFMUUCAVNAELC
RETLIFNOITULOSNAELC
SYAWRIATELNIKCEHC
ENIHCAMELACSED
Daily
X
X
X
X
SEHSURBROTOMMUUCAVKCEHC
MonthlyYearly
X
X
FORM NO.56041563 / Rainmaker™ H - 11
Page 12
12 - FORM NO. 56041563 / Rainmaker™ H
https://harrissupplyind.com - To Order Parts Call 608-268-8080
Page 13
PART LIST RAINMAKER
https://harrissupplyind.com - To Order Parts Call 608-268-8080
TM
H
ItemRef. No. QtyDescription
1566499871Drain Gate
1A566499871Spout
2561028168Screw, 8-32 x .50
3561080742Latch, Rubber W/Strike
4566499871O-Ring, Small
4A566499871O-Ring, Large
4B566499871Nut, Cast Aluminum, 1-1/2”
5566499831Recovery Tank, Blue
6561080611Hose Barb
7561028161Gasket
8561080551Lid, 6”, Clear Center, W/Ring
8A561080542Chain, 8”
8B561028161Screw, 10-32 x .62
8C561028121Screw, 10-32 x .38
9561028166Screw, 8-32 x .88
9A561028166Lock Nut, 8-32
10561080521Float, Ball and Cage on Manifold
13561080531PVC Elbow
14561028174Hose Clamp
15561028411Hose, Vacuum, 2” x 41”, Ribbed
16561028251Heat Exchanger, Complete
17561028171Hose Clamp
18561028691Mount Bracket, Heat Exchanger
19561028251Hose, Braided SS
20561028254Washer, Brass
20A561028133Washer, Fiber
21561028251Nipple, Stainless Steel
22561028251Bushing, Fiber
23561028251Heat Control Switch
24561028251Elbow, Brass
24A561028251Coupling, Brass
255610281618Washer, Flt 3/16
265610281618Lock Nut, 1/4
27561028182Vacuum Motor, 120V
28561028182Gasket, Vacuum Motor
29561028422Manifold
30561028166Bolt, 1/4-20 x 5.00
https://harrissupplyind.com - To Order Parts Call 608-268-8080
Vacuum Motor:
Water lift:
Air Flow:
Amp Draw:
Tank Construction:
Solution Tank Capacity:
Recovery Tank Capacity:
Application Flow:
Solution Hose Length:
Recovery Hose Length:
Power Cord:
Rear Wheels:
Front Castors:
Heat Exchanger:
Height:
Length:
Width:
Machine weight:
Two 2-Stage
150”
100 cfm
16 amps, each cord
Rotationally molded polyethylene
14 Gal. (53.2 L)
12 Gal.(45.4 L)
100 psi
15 ft. (4.5 m)
15 ft. (4.5 m)
Two 25 ft. (7.6 m), High visability yellow, removable
10 in. (25 cm)
4 in. (10.2 cm)
2000 Watt
38 in (96.5 cm)
36 in (91.4 cm)
17.6 in (44.7 cm)
83 lb (38 kg)
ItemRef. No. QtyDescription
561080961Fan Kit (#79, 80)
561028111Wheel Kit (1 each of #50, 51)
561028121Solution Lid Kit (#8C, 60 / also includes #8A)
561028161Hardware Kit (#2, 7, 8B, 9, 9A, 25, 26, 30, 31, 32, 39, 44, 70, 77, 78, 84, 85, 87-89, 92)
561028171Hose Clamp Kit (#14, 17, 61)
561028181Vacuum Motor Kit (1 each of #27, 28)
566499871Drain Gate Kit (#1, 1A, 4-4B)
566499891Cord Retainer Kit (1 each of #45, 46)
561028291Hose Barb Kit (#33, 63 / also includes #24)
561028131Quick Disconnect Kit (#20A, 40)
561028151Bracket Kit (#30A, 90, 91)
561028251Heat Exchanger, Complete (#16, 19, 20, 21-24A / also includes #20A, 40)
561028191Heat Repair Kit (#23)
561028041Single Bend Wand Assembly
561028051Double Bend Wand Assembly
561028071Extractor Hand Tool
561028611Vac Hose / Pressure Line 25ft.
561028711Vac Hose / Pressure Line 15ft.
14 - FORM NO. 56041563 / Rainmaker™ H
KITS
ACCESSORIES
Page 15
NOTES
https://harrissupplyind.com - To Order Parts Call 608-268-8080
FORM NO.56041563 / Rainmaker™ H - 15
Page 16
https://harrissupplyind.com - To Order Parts Call 608-268-8080
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.