Kenmore 625.385200, Elite 625.385200 Use & Care Manual

Use & Care Guide Manual de Uso y Cuidado
English / Espa_ol
Model ,/Modelo No. 625.385200
Ilenmore Elite
System tested and certifed by NSIF nternat onal
against NSIF/AIIqSI Standard 42 for the reductio_'_
of chlorine taste and odor, and Star_da_'d 44 for hardness reductiorb elf ciency and the reduct on
of barium arid radium 226/228o
NSIF nternat orK,_lde acuerdo a Norma II",,,,I,SIF::!ANSI 42
para la reducci6n dd sabor y el olor a cloro, y
Irqorma 44 para la reducci6n de la dureza_ ef ciencia
y la reducci6n dd baio y del radio 226/228,
@
A w_"lllll'@_sef'lllll'@n@__nd _ who_e home fi_"lllll'@_in en@
÷ ° Agu
Un ab_andado_ de agua con fi_o in_eg_ado papa toda _a casa
Sears Brands Management Corporation 3333 Beverly Road Hoffman Estates, IL 60179 U.S.A. www.kenmorewater.com
www.kenmore.com www.sears.com
I_ II II I/:
®
Printed on recycled paper/ Impreso en papel reciclado
P/N 7329853 (Rev. A 7/25/11)
WARRANTY ON KENMORE ELITE®HYBRID WATER SOFTENER
ONE YEAR LIMITED WARRANTY ON HYBRID WATER SOFTENER
When installed, operated and maintained according to all instructions supplied with the product, if this
Kenmore appliance fails due to a defect in material and workmanship within one year from the date of pur-
chase, call 1-800-4-MY-HOME ® to arrange for free repair. THREE YEAR LIMITED WARRANTY ON ELECTRONIC PARTS
When installed, operated and maintained according to all instructions supplied with the product, if any of the following electronic parts fail due to a defect in material or workmanship, call 1-800-4-MY-HOME ®to arrange
for free part replacement: Brine Tank Light, Electronic Board, Sensor Housing, Wiring Harness, Transformer, Micro Switch, Drive Motor, Power Cable. After the first year you must pay an initial trip charge.
TEN YEAR LIMITED WARRANTY AGAINST LEAKS When installed, operated and maintained according to all instructions supplied with the product, if the water
softener tank or salt storage drum develops a leak within ten years from the date of purchase, call 1-800-4-MY-HOME ® to arrange for free tank or drum replacement. After the first year you must pay an
initial trip charge. All warranty coverage does not include water softener resin or carbon, which are expendable items.
If this appliance is used for other than private family purposes, this warranty applies for only 90 days from
the date of purchase.
This warranty covers only defects in material and workmanship. Sears will NOT pay for:
1. A service technician to instruct the user in correct product installation, operation or maintenance.
2. A service technician to clean or maintain this product.
3. Damage to or failure of this product if it is not installed, operated or maintained according to the all instructions supplied with the product.
4. Damage to or failure of this product resulting from accident, abuse, misuse or use for other than its intend-
ed purpose.
5. Damage to or failure of this product caused by the use of detergents, cleaners, chemicals or utensils other than those recommended in all instructions supplied with the product.
6. Damage to or failure of parts or systems resulting from unauthorized modifications made to this product.
Disclaimer of implied warranties; limitation of remedies
Customer's sole and exclusive remedy under this limited warranty shall be product repair as provided herein.
Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to
one year or the shortest period allowed by law. Sears shall not be liable for incidental or consequential dam- ages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential dam-
ages, or limitation on the duration of implied warranties of merchantability or fitness, so these exclusions or limitations may not apply to you.
This warranty applies only while this appliance is used in the United States or Canada. This warranty gives you specific legal rights, and you may also have other rights which vary from state to
state.
Sears Brands Management Corporation, Hoffman Estates, IL 60179 U.S.A.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
Warranty ..................................................................................... 2
Safety Guides .................................................................................. 3
Specifications & Dimensions ...................................................................... 4
Packing List ................................................................................... 5
Plan Your Installation .......................................................................... 5-7
Installation .................................................................................. 7-11
Programming the Softener ..................................................................... 12-13
Flushing the System ............................................................................. 14
Adding Salt to the Storage Tank .................................................................. 14
What Your Hybrid Water Softener Will Do .......................................................... 15
Controller Features ........................................................................... 15-19
Care of Your Water Softener ..................................................................... 20
Service Information .......................................................................... 20-23
Exploded View & Parts List ................................................................... 24-27
Read all steps and guides carefully before installing and using your new water softener. Follow all steps exactly to correctly install. Failure to follow them
could cause personal injury or property damage.
Reading this manual will also help you to get all the
benefits from your water softener.
Your Kenmore Elite ® Hybrid Water Softener will reduce hardness minerals from water. This is meas-
ured in grains per gallon (gpg). It will also remove some clear water iron _. This is measured in parts
per million (ppm). See the specifications page for the maximum limit of hardness removal. It will also
reduce taste and odor in water, and will reduce bar- ium and radium 226/228 in water (see performance
data sheet for details).
A water softener will not improve other water problems such as acidity or iron other than clear water iron.
Do not attempt to use this product to make safe drinking water from non-potable water sources. Do
not use the system on microbiologically unsafe water, or water of unknown quality without adequate disin-
fection before or after the system.
Check with your local public works department for plumbing and sanitation codes. You must follow
their guides as you install the system. Follow your local codes if they differ with guides in this manual.
In Massachusetts, plumbing code 248-CMR 3.00 and
10.00 shall be adhered to. Consult with a licensed plumber.
Use only lead-free solder and flux for all sweat-solder connections, as required by federal codes, when installing soldered copper plumbing.
Use care when handling the water softener. Do not turn upside down or drop.
Avoid installing in direct sunlight. Excessive heat may cause distortion or other damage to non-metallic parts.
This water softener works on water pressures of 20 psi (minimum) to 125 psi (maximum). If your house water
pressure is over the maximum, install a pressure reduc- ing valve in the water supply pipe to the softener.
Temperature of the water supply to the softener must be between 40°F and 120°F. Do not install on hot water.
If installing the water softener outdoors, do not locate
where it will be exposed to wet weather, direct sunlight or extreme hot or cold temperatures.
This softener works on 24 volt, 60 Hz electrical power only, supplied by a direct plug-in transformer (includ-
ed). Be sure to use the included transformer and plug it into a nominal 120V, 60 cycle household outlet that
is properly protected by an overcurrent device such as a circuit breaker or fuse. If transformer is replaced,
use only the authorized service, Class II, 24V 10VA transformer.
The capacity to reduce clear water iron is substantiated by Water Quality Association test data.
European Directive 2002/96/EC requires all electrical and electronic equipment to be disposed of according to Waste Electrical and Electronic Equipment (WEEE) requirements. This directive or similar laws are in place nationally and can vary from region to region. Please refer to your state and local laws for proper disposal of this equipment.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
3
Model No. 625.385200
Model Code
520
11,000 @ 2.6 Ibs.
Rated Softening Capacity (Grains @ Salt Dose)
24,700 @ Z8 Ibs. 31,100 @ 13.4 Ibs.
Rated Efficiency (Grains/Pound of Salt @ Minimum Salt Dose)
Water Used During Regeneration @ Minimum Salt Dose
Rated Service Flow Rate
Amount of High Capacity Ion Exchange Resin
Pressure Drop at Rated Service Flow
Water Supply Max. Hardness Water Supply Max. Clear Water Iron
Water Pressure Limits (minimum / maximum) Water Temperature Limits (minimum / maximum)
Minimum Water Supply Flow Rate
Intermittent Flow @ 15 psi
Maximum Drain Flow Rate
0.50 ppm
0.75 ppm
Rated Capacity at Chlorine Concentration*** of-
1.0 ppm
1.5 ppm
2.0 ppm
4,230 @ 2.6 Ibs.
5.0 gallons / 1,000 grains
8.0 gpm
0.98 cu. ft.
6.5 psig
120 gpg
3 ppm*
20 - 125 psi
40 - 120 °F
3 gpm
13.7 gpm**
2.0 gpm
2,280,000 gal.§
1,520,000 gal.§
1,140,000 gal.§
760,000 gal.§ 570,000 gal.
*Capacity to reduce clear water iron is substantiated by WQA test data. State of Wisconsin
requires additional treatment if water supply contains clear water iron exceeding 5 ppm.
**Intermittent flow rate does not represent the maximum service flow rate used for determin-
ing the softener's rated capacity and efficiency. Continuous operation at flow rates greater
than the service flow rate may affect capacity and efficiency performance.
***Typical residential chlorine concentration is 0.5 to 1.0 ppm.
§ From independent laboratory test data. These systems conform to NSF/ANSI Standards 42 and 44 for the specific performance
claims as verified and substantiated by test data. The efficiency rating is only valid at the stated salt dose. These softeners were efficiency
rated according to NSF/ANSI Standard 44.
Variable Salt Dose: The salt dose is selected by the electronic controls at regeneration time
based on the amount needed.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
4
_17"_
3-3/4"
IN - OUT
]_
34 _
L J
FRONT VIEW SIDE WEW Figure 1
The parts required to assemble and install the water softener are included with the unit. Thoroughly check
the water softener for possible shipping damage and parts loss. Also inspect and note any damage to the
shipping carton.
Remove and discard (or recycle) all packing materials.
To avoid loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use
them.
iiiiilHliiiii!! l!!!ii ....
Ground Clamp
Kit
O-rings
Cold Water
to House
Hot Water
to House
Installation
Bypass Valve
Hose Clamps
THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT
(Shows sequence of equipment only - not all items are needed in all applications)
Untreated Water to _.,,,____
Outside Faucets
20 ft. Drain Hose
Adaptor Elbow
J
Sediment
Cartridge
Filter
Adaptors
Grommet
City Water Supply
Pressure
Tank
Clips
(including 1 spare)
Figure 2
t
Water Hybrid Iron Heater Water Filter
Softener
Always locate an Iron Filter UPSTREAM of the Hybrid Water Softener.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
J
Well Water Supply
I
Well
Pump
t
Figure 3
5
TYPICAL INSTALLATION
WHERE TO INSTALL THE HYBRID WATER SOFTENER
Review the following points before you choose a place
to put your softener:
1. Place as close as possible to, but always downstream from, the pressure tank (well water) or water meter
(city water).
2. Place as close as possible to a water drain such as a
floor drain, laundry tub, sump or standpipe (See Fig. 4).
3. Connect to the house main water pipe UPSTREAM
OF THE WATER HEATER (See Fig. 3). The tempera-
ture of water going through the softener must not be
more than 120°F (49°C). Hot water will damage inner softener parts. To reduce the risk of hot water
backup, piping between the softener and water heater should be as long as possible.
4. Keep outside faucets on hard water to save soft
water and salt. See Fig. 4.
5. Do not install in a place where the softener could freeze. Damage caused by freezing voids the war-
ranty by Sears Brands Management Corporation.
6. Put the softener in a place where water damage is
least likely to occur if it develops a leak. Sears or
the manufacturer will not repair or pay for water damage.
7. A grounded, 120V, 60 Hz. electrical outlet is needed
within 10 feet of the softener to plug in the trans- former (See Fig. 4). Be sure the outlet and trans-
former are in an inside location, protected from wet weather. Use a continuously "live" outlet, which can-
not be accidentally switched off.
8. When installing in an outside location, you must take
the steps necessary to assure the softener, installation plumbing, and wiring, are protected from the ele- ments, direct sunlight, contamination, vandalism, etc.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
6
CHECK YOUR WATER PRESSURE BEFORE INSTALLING
For your water softener to work properly, incoming
water pressure in your house pipes must be no lower than 20 pounds per square inch (psi). The highest
allowable pressure is 125 psi. If pressure is above 125
psi, buy and install a pressure reducing valve in the pipe supplying water to the softener's inlet.
NOTE: If water pressure during the day is 100 psi or
more, pressure during the night may go above 125 psi.
INSTALL SINGLE BYPASS VALVE AND/OR THREADED INSTALLATION ADAPTORS
Complete the following steps to assemble the adaptors and/or the included single bypass valve.
1. Close the shutoff valve on the house main water pipe, near the water meter or pressure tank, to turn off the water.
2. Shut off the gas or electric supply to the water
heater.
3. Open the highest and lowest water faucets in your
house. This will let water drain from the pipes. Close faucets after water has drained.
4. Remove the top cover. Pull outward on the two tabs
to release top cover (see Fig. 5). The salt lid remains
attached to the top cover when removed. Set both covers aside so they will not get scratched or broken.
Salt Lid
Top
SINGLE BYPASS VALVE:
6. Lightly coat the o-rings with silicone grease and slide
them onto the bypass valve. Push the bypass valve into the softener valve's inlet and outlet ports as far
as it will go. Snap the two large holding clips into
place, from the top down as shown (see Fig. 8).
CAUTION: Be sure the clips snap firmly into place so
the bypass valve will not pull out.
INLET AND OUTLET THREADED ADAPTORS:
7. Lightly coat the o-rings with silicone grease and slide them onto the installation adaptors. Push the adap-
tors into the valve inlet and outlet ports, or bypass valve ports, as far as they will go. Both adaptors are
the same and fit either port. Snap the two large
holding clips into place, as shown (see Fig. 8).
CAUTION: Be sure the clips snap firmly into place so
the adaptors will not pull out.
5. Visually check and remove any foreign mate- rials from the valve inlet and outlet ports (see
Fig. 6). Carefully remove the two large plastic
clips (you will use them). Check to be sure the turbine and support are firmly in place
(see Fig. 7).
NOTE: If you will not install the included bypass
valve because you will have a 3-valve bypass in your plumbing, skip step 6, but perform step 7.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
Figure 5
Valve Inlet'_ _
O-Rings
Clip
Clips
Threaded
Valve Installation Outlet Adaptors
O-Rings
Clip
Single
Bypass Valve
Figure 6
7
INSTALL SINGLE BYPASS VALVE (cont.)
Before installing the bypass valve and/or installation
adaptors, make sure that the turbine and support are firmly in place inside the softener valve's outlet port.
Turbine
Support
Valve Outlet j Turbine /
Figure 7
INSTALL HOLDING CLIPS
Bypass Valve or
Installation Adaptor
Plastic Clip
\
ASSEMBLE INLET AND OUTLET PLUMBING
Measure, cut (thread if needed) and put together all
pipe and fittings up to the main water pipe. Make sure
that the incoming water supply pipe goes to the valve inlet side.
CAUTION: Never solder fittings while connected to
nonmetallic parts. Wait until soldered pipe has cooled before connection. See Fig. 10.
CAUTION: Be careful when putting pipe fittings togeth-
er. Do not cross thread, and do not over- tighten.
______ /Vlain Water
_ _ Hard
4. Solder. _ Water NOTE: To be certain
that heat will not travel down the pipe
and into the bypass valve or installation
adaptors, wrap the 2. Solder. When
bottom of the pip_ / cool, do step 3.
and the bypass v_lve with a wet rag. L_
Pipe
Incoming
1. Cut pipe to correct length
Valve Inlet or Outlet
Plastic clip snaps
into groove in
bypass or adaptor
O-Ring
Figure 8
ALTERNATE BYPASS VALVE INSTALLATION
If connecting to floor level plumbing, install the bypass valve turned
downward, as shown.
OUT
iN Figure 9
__ -_ 3. Put threaded
J
adaptor into
bypass valve
port.
Figure 10
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
CONNECT THE VALVE DRAIN HOSE
Take a length of 3/8" inside diameter drain tubing (supplied) and attach one end to the drain fitting (see
Fig. 11). Use a tube clamp from the parts bag to hold it
in place. Put the other end of the tubing over a floor drain, into a laundry tub, standpipe, or other suitable
drain. Check your local codes.
Leave an air gap of about 1-1/2" between the end of
the hose and the drain. This gap is needed so you don't get a backflow of sewer water into the softener.
Do not put the end of the hose into the drain or con-
nect without the air gap.
Locate and support the hose so it does not kink or have
sharp bends. Secure the hose end so water pressure does not cause the hose to "whip". Tie or wire it in
place. Do not pinch the hose shut. The softener will not work if this drain hose is pinched, plugged, closed
or restricted in any way. Direct drain flow down into drain from drain line as flow could possibly overshoot
the drain cover.
Keep the hose lower than the drain fitting. In some
homes, to get to a drain you must raise the hose and run it overhead. Do not raise the hose more than 8 feet
above the floor.
COPPER DRAIN TUBE: Local plumbing codes may
require the use a copper valve drain tube. A copper
tube is also best to use if running a drain line overhead. To adapt a copper drain tube to the softener, purchase
a compression fitting (1/4" female pipe threads x 1/2" O.D. tube) and tubing from your local hardware store.
CONNECT SALT TANK OVERFLOW HOSE
1. Locate the rubber grommet, adaptor elbow and tube clamp (see Fig. 11) that are in the parts bag.
2. Push the grommet into the hole in the salt tank wall
so that half is inside and half is outside.
3. Push the larger end of the adaptor into the grommet.
4. Push one end of a length of 3/8" I.D. tubing (sup-
plied) onto the tube adaptor, using a tube clamp from the parts bag to hold it in place.
5. Put the other end of the tubing over the floor drain.
IMPORTANT: Overflow water must run down by gravity
through the tubing. Do not raise the tub- ing higher than the adaptor (see Fig. 11).
IMPORTANT: Do not connect this hose to the valve
drain hose you just installed (see above). Both drains must have a separate hose.
Grommet Tube
I Adaptor
NOTE: Drain Hose
(20 ft.) is included. See also parts list.
_t Drain
ring
Tube ...._ _
Clamp Y_
Salt Tank
Overflow Hose
Clip 1/4 NPT
Threads CompressionFitting, 1/4 NPTx
Barbs 1/2" O.D. Tube(not supplied)
\\
\\
xx
\\
\\
\\
--_,_V'_lv_ _ than floor Drain Hose
Cut barbs from drain fit- 1/2" Outside
ring {pull clip and remove Diameter Copper
fitting from valve) Tube (not supplied)
\\
\\ Todrain
\\
\\ point other
\\
drain.
Support tub-
ing in place
Tie or wire 1-1/2" as needed.
tubing in Air Gap
place
FLOOR DRAIN
_ LAUNDRY TUB
SUBSTITUTING RIGID DRAIN LINE
..... STANDPIPE
.... _ ._.____L
Gap
. , Gap
Figure 11
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
9
METALPIPEGROUNDING
RINSE OUT CARBON FINES
TO
Valve Inlet
Ground
Clamp
(2 halves)
Screw with I Iockwasher
& nut
FROM
Valve Inlet
g
Figure 12
INSTALL GROUNDING CLAMP
The house cold water pipe (iron or copper) is often used to ground all electrical outlets in the home. To maintain
this ground, use the ground clamp kit included in the parts bag. Install the ground clamp across the inlet
and outlet metal pipes (see Fig. 14). Make sure good contact is made between the pipe and the clamps.
INSTALL COVERS
After installing your water softener, put the covers on. Angle the covers so the top cover clips onto the back
first, then bring down in front and clip on the tabs inside the rim and lower the salt lid closed (See Fig. 5).
CONNECT TO ELECTRICAL POWER
The softener works on 24 volt, 60 Hz electrical power. The included transformer changes standard 120 volt AC
house power to 24 volts. You must plug the water soft- ener's transformer into a grounded, 120 volt outlet only.
Be sure the outlet is always "live" so it cannot be
switched off by mistake. NOTE: The electrical outlet you plug the transformer
into must be indoors, protected from weather.
Small particles of carbon filtration material are gener- ated during manufacturing and shipping, which will exit
the media tank with the first water flow. These carbon
"fines" are not harmful, but give the water a gray color
and should be rinsed down the drain before any water from the softener is directed to the home's faucets or
water heater.
CAUTION: To avoid water or air pressure damage to
softener inner parts, and to flush pipe chips or other residue from the water pipes, be
sure to do the following steps exactly as instructed.
1. Make sure the softener's valve drain hose is hooked up and the open end directed to a floor drain, laun-
dry tub or other suitable type of drain.
2. The system should be connected to electrical power.
3. Place bypass valve(s) in "bypass" position (see
Figures 13 & 14). On a single valve, slide the stem inward to bypass. On a 3-valve bypass, close the
inlet and outlet valves and open the bypass valve.
4. Fully open the house main water pipe shutoff valve.
5. Initiate a regeneration by pressing and holding for 3
seconds the REGENERATION button (see Figure 15 on page 12). The valve motor will start running and
the valve will advance to the "Fill" position.
6. After you hear the valve motor stop running (valve in
"Fill" position), press, but do not hold, the REGENER- ATION button. The valve will advance to the "Brine"
position.
7. After you hear the valve motor stop running (valve in
"Brine" position), press, but do not hold, the REGEN-
ERATION button. The valve will advance to the
"Backwash" position.
8. Once the unit is in backwash, place bypass valve(s)
in SERVICE, EXACTLY as follows: a. Single Bypass Valve: Slowly, slide pull the valve
stem outward toward service, pausing several times to allow the softener to pressurize gradually.
b. 3-Valve Bypass: Fully close the bypass valve and open the outlet valve. Slowl_z open the inlet valve,
pausing several times to allow the softener to pres- surize gradually.
9. Let the softener complete the backwash and fast
rinse cycles (takes about 20 minutes). When the regeneration ends, the softener's valve returns to the
service position.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
10
LEAK TEST
To check for leaks, complete the following steps:
1. Fully open two nearby cold water faucets down- stream from the softener.
2. Observe steady weater flow from both open faucets.
3 After about three minutes, open a hot water faucet
for about one minute, or until all air is expelled, then close.
4. Close both cold water faucets.
5. Check your plumbing work for leaks, and fix right
away if any are found. Be sure to observe previous caution notes.
SINGLE BYPASS VALVE
Pull stem outward
for Service
7
7
Push inward
for Bypass
NOTE: If this procedure is performed on a new softener,
water coming from the taps may initially be dis- colored. This normally occurs the first time
water runs through the resin bed. The discol- ored water is not harmful, and the discoloration will not last more than a few minutes.
RESTART THE WATER HEATER
Turn on the gas (or electric) supply to the water heater and light the pilot.
YOUR PLUMBING INSTALLATION AND
ELECTRICAL WORK ARE NOW COMPLETE.
FOR SERVICE
Close bypass valve.
Open inlet & outlet
valves.
FOR BYPASS
Open bypass valve.
Close inlet & outlet
valves.
3-VALVE BYPASS
Outlet
Valve
Figure 13
Bypass Valve
Inlet Valve
Figure 14
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
11
REGENERATION button Display SELECT button UP button
/ / / \
SET SALT LEVEL button BLUE LIGHT (see below) WATER USE button
DOWN button Figure 15
BLUE LIGHT
When the Kenmore Elite ® Hybrid Water Softener is connected to electrical power, the blue light on the con-
trol panel will be on or flashing, as follows:
Blue light flashing rapidly, with "PRESENT TIME" shown in the display and the clock flashing slowly -
The present time needs to be set, either during initial start up or after a long power outage. See "Set
Present Time of Day", at right.
Blue light flashing slowly, along with the salt level indicators in the display - The salt monitor system
indicates a low salt level and needs to be set. See "Salt Monitor System" on Page 16.
Blue light flashing rapidly, with "Err" shown in the display - The electronic self-diagnostics have detect-
ed a problem. See "Troubleshooting" on Page 21.
Blue light on steady (not flashing) - The system has power applied and does not require any attention.
PROGRAM THE SOFTENER
When the transformer is plugged into the electrical out- let, the model code (520) and a test number (example:
J3.0), are briefly shown in the display. Then the words "PRESENT TIME" appear and 12:00 PM begins to flash.
SALTSIGNAL L-- _tFI
L=_2=_-LJ2L2_C !__t
8
7 6
5
4 t _-t Ft
2
1
SALT SIGNAL LEVEL LEVEL
8
7
6 5 4
3
2
I
l 71.Fl Fl P,
_C,uu
PRESENT TIME
Figure 16
SET PRESENT TIME OF DAY
If the words "PRESENT TIME" do not show in the dis- play, press the SELECT button a few times until they do.
SALT SIGNAL LEVEL LEVEL
8
7
6 5
4 3
2
1
I I,Z!F A"
PRESENT TIME
SALT SIGNAL
LEVELLEVEL
8 7
6
5
4
3
2
I
J I.F Fe..
-i.30
PRESENT TIME
Figure 17
1. Press the /X UP or V DOWN buttons to set the present time. Up moves the display ahead; down
sets the time back. Be sure AM or PM is correct.
NOTE: Press buttons and quickly release to slowly
advance the display. Hold the buttons down for fast advance.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewaterocom
12
2. When the correct time is displayed, press the SELECT
button, and the display will change to show the "Hardness" screen.
SETWATERHARDNESSNUMBER
If you completed the previous step, the word "HARD- NESS" should show in the display. Otherwise, press the
SELECT button several times until it does.
SALT SIGNAL
LEVELLEVEL
8
7
6 5
4 3
2
1
_C
G_
HARDNESS
Figure 18
The softener's default recharge start time is 2:00 AM. This is normally a time of day when water is not
being used in the household. Hard water bypasses the softener if the household draws water during the
recharge cycle. If a different recharge start time is desired, press the f UP or V DOWN buttons to
change the time, in 1-hour increments. Be sure AM or PM is correct.
.
When the desired recharge start time is displayed, press the SELECT button, and the display will change
to show one of the "Salt Type" screens shown below.
1. Press the f UP or V DOWN buttons to set the hardness of your water supply, in grains per gallon.
The default is 25.
NOTE: If your water supply contains iron, compensate
for it by adding to the water hardness number.
For example, assume your water is 20 gpg hard
and contains 2 ppm iron. Add 5 to the hardness number for each 1 ppm of iron. In this example,
you would use 30 for your hardness number.
20 gpg hardness
2ppmironx5-- 10
(times)
+10
30 HARDNESS NUMBER
If your water supply contains iron, it is recom-
mended that you clean your water softener resin bed at least every 6 months. Your local Sears
store has Water Softener Cleaner (Part Number
34427) available.
2. When finished setting your water's hardness number,
press the SELECT button, and the display will change to show the "Recharge Time" screen.
SET RECHARGE (REGENERATION) START TIME
If you completed the previous step, the words "RE-
CHARGE TIME" should show in the display. Otherwise, press the SELECT button several times until they do.
SALT SIGNAL LEVEL LEVEL
8
7
6
5
4
3 2
1
TI,Fl FI AM
C'uu
RECHARGE
TIME
Figure 19
SALT SIGNAL LEVELLEVEL
8
7
6
5 4 3
2 1
SALT SIGNAL
LEVELLEVEL
8 7
6
5 4 3
2
I
FJ
NCl
Figure 20
SET SALT TYPE
If you completed the previous step, either "NaCI" (for
Sodium Chloride) or "KCI" (for Potassium Chloride) should show in the display. Otherwise, press the
SELECT button several times until one of them does.
1. Press the f UP or V DOWN buttons to set the type of salt you will be using in your water softener. The
default is NaCI (standard Sodium Chloride water sof- tener salt). If you will be using I<CI (Potassium
Chloride) instead, be sure to set salt type to KCI. This setting adjusts the regeneration cycle times to com-
pensate for the different rate at which KCI dissolves. See also the following page for more information on
salt types.
2. When the correct salt type is displayed, press the
SELECT button, and the display will return to the nor- mal run (time of day) screen.
SALT SIGNAL
LEVEL LEVEL
8 OFF 7
6
5
4
3 2
1
Figure 21
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
13
After all installation steps have been completed: I. Make sure the bypass valve(s) is in the "service"
(open) position.
2. Start a recharge: Press the REGENERATION button and hold for 3 seconds, until "RECHARGE", "Serv"
and "Fill" begin to flash in the display. The recharge will take about 2 hours to complete.
3. After the recharge has completed, fully open a cold water faucet, downstream from the softener, and
allow 50 gallons of water to pass through the system. This should take at least 20 minutes.
4. Close the faucet.
Your new Sears softener is now softening the water for your household needs. However, your WATER HEATER
is filled with hard water. To have fully soft water right away, you can drain the water heater so it refills with
soft water. If you don't drain the water heater, it will take a few days before you have fully soft water.
NOTE: If this procedure is performed on a new softener,
water coming from the taps may initially be dis- colored. This normally occurs the first time
water runs through the resin bed. The discol- ored water is not harmful, and the discoloration will not last more than a few minutes.
ADDING SALT TO THE STORAGE TANK
You must keep salt in the tank, but it is not necessary to fill it full. Especially in humid areas, it is best to fill the
storage tank no more than half full, and to add salt more often. Salt "bridging" occurs more often when
conditions are humid. Use NUGGET or PELLET water softener salt. DO NOT
use rock salts, as they have dirt and sediments that will stop the softener from working. To maintain optimum
performance of your water softener, the salt tank should be cleaned out every 2 to 3 years.
POTASSIUM CHLORIDE (I(CI) SALT
If you choose Potassium Chloride (KCI) as a regenerant,
following these suggestions will help give you years of maintenance free service.
1. Place only one bag of KCI in your softener at a time
(the salt storage tank should contain no more than 60 pounds of KCI at any one time).
2. A softener using I<CI should not be placed in areas with temperature fluctuations and high humidity (KCI
will harden in these environments and may make the
softener inoperable).
3. Check the brine tank and brinewell (black tube in
salt storage tank) monthly. If hardening is present, pour small amounts of warm water onto hardened
areas until they loosen.
4. Be sure to set "Salt Type" on the controller to "KCI". This setting adjusts the regeneration cycle times to
compensate for the different rate at which KCI dis- solves. See "Set Salt Type" on the previous page.
Persons who are on sodium restricted diets should con- sider the added sodium as part of their overall sodium intake. For example, if your water supply is 15 grains
hard, and you drank 3 quarts of softened water you would consume 335 milligrams of sodium. That is
equivalent to eating 2-I/2 slices of white bread.
Persons who are concerned about their drinking water should consider a Kenmore reverse osmosis drinking
water system that will remove in excess of 90°/o of the sodium and other drinking water contaminants.
WATER SOFTENING SALT WITH IRON
REMOVING ADDITIVES
Some salts have an additive to help the softener handle iron in the water supply. These salts may be used if
your water supply has a high iron content. It is recom-
mended to use Sears Water Softener Cleaner (refer to the parts list in back of manual for part number) for
periodic treatments to keep your resin bed clean. This is available at your local Sears store.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
14
The Kenmore Elite ® Hybrid Water Softener has been designed to include two different types of media, a
high quality media that reduces tastes and odors and a high efficiency media to remove hardness minerals.
This Hybrid Water Softener will provide you and your home all the benefits of soft water, while providing
whole home chlorine taste and odor reduction and bar- ium and radium 226/228 reduction. You can have fil-
tered water from your kitchen faucet for food prepara- tion and drink, in the bath and shower which will
reduce chlorine's aesthetic effect on your skin and hair, and at every bathroom sink for brushing your teeth.
There are no filters to change.
Based on NSF-tested rated capacity under NSF/ANSI Standard 423, the Kenmore Elite® Hybrid Water
Softener has an estimated useful life for chlorine taste and odor reduction of over 10 years.
*NSF rated capacity is 570,000 gallons.
EXTRA RECHARGE
Sometimes, a manually initiated recharge (regeneration) may be desired, or needed. Two examples are:
You have used more water than usual (guests visiting) and you may run out of soft water before the next
automatic regeneration.
You did not add salt to the softener before it ran out. Add salt to the softener before regenerating.
You can start a regeneration immediately, or you can set the controller to regenerate at the next preset
recharge time (2:00 AM, or as set).
RECHARGE NOW
Press the REGENERATION button and hold for 3 sec-
until the words "RECHARGE", "Serv" and "Fill"
begin to flash in the display. The softener enters the fill cycle of regeneration immediately. This regeneration
will take about 2 hours to complete. Then, you will have soft water again.
NOTE: If the "Clean Feature" is set ON, the normal
regeneration cycle is preceded by a cleaning backwash and rinse. The words "CLEAN" and
"Bkwsh" or "Rinse" flash in the display, along with the minutes of the clean cycle remaining.
SALT SIGNAL se_
LEVEL LEVEL Fill
8
7
6
5
_4 _3
_ _P__--
RECHARGE
Figure 22
RECHARGE TONIGHT
Press and release (do not hold) the REGENERATION
button. "RECHARGE TONIGHT" will begin flashing in
the display, and the softener will begin regeneration at
the next preset recharge time (2:00 AM, or as set). If you decide to cancel the regeneration before it starts,
press and release the REGENERATION button once more. "RECHARGE TONIGHT" will stop flashing in the
display.
LEVEL LEVEL
SALT SIGNAL _: _ T_ PM
....... _G
8 _
7
6
5
_4
_3
RECHARGETONIGHT
Figure 23
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
15
SALT MONITOR SYSTEM
OPTIONAL SETTINGS:
The water softener has a blue light that will flash to remind you to add salt to the storage tank.
NOTE: You must set salt level each time salt is added
to the water softener.
NOTE: The salt monitor system estimates salt levels, and
accuracy will vary with different salts.
To set this monitor system:
1. Lift the salt lid and level the salt in the storage tank.
2. The yellow salt level decal, on the brinewell inside
the tank, has numbers from 0 to 8 (see Fig. 24).
Observe the highest number the leveled salt is at, or closest to.
Salt Level _v__L
ALTs
/il °a s
/5 _IBrinewell
eca,
Figure 24
3. Press the SET SALT LEVEL button as many times as necessary to make the salt level bars in the display
(see Fig. 24) match the number on the decal. At level 2 or below, the salt level bars, signal level indi-
cators and blue light will flash.
4. If you want to turn the salt monitor off, press the SET
SALT LEVEL button past 8, until "OFF" shows in the display next to the number 8.
SALT EFFICIENCY
CLEAN FEATURE
CLEAN FEATURE MINUTES
97°/o FEATURE
12 / 24 HOUR CLOCK
GALLONS / LITERS
MAXIMUM DAYS BETWEEN REGENERA-
TIONS
BACKWASH & FAST RINSE TIMES
To set any of these options, press and hold SELECT for 3 seconds until "000" shows in the display. Then
press (do not hold) SELECT again to display one of
the "Salt Efficiency" screens shown below.
LEVEL LEVEL
S,ONAL'-'FF
===;=== W_t
7
5 4
3 2
I
SALT SIGNAL
LEVEL LEVEL
8
7 6
5
4
3
_2,_/__
n
u_
, /
Efficiency
SALT EFFICIENCY: When this feature is ON, the water softener will operate at salt efficiencies of 4000 grains of hardness per pound of salt or higher.
The softener may recharge more often using smaller salt dosage and less water. This softener is shipped
with the efficiency feature set OFF. Installations in the State of California require this setting to be
turned ON. Use the /X UP or V DOWN buttons to change between OFF and ON.
Icon
Figure 26
SALT SIGNAL
LEVEL LEVEL
8 OFF
7
6 5
4 3
2
1
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
16
Figure 25
California Efficiency Requirement
Your Kenmore Water Softener has a "High
Efficiency" feature that can be set ON or OFF.
This softener is shipped with the efficiency feature set OFF, which will utilize the maximum rated
capacity while most often achieving maximum salt efficiencies. When installing this unit in the State
of California, you MUST turn the efficiency feature ON. The softener may initiate more frequent
recharges, but it will operate at 4000 grains per pound of salt or higher.
2. Press SELECT again to display one of the "Clean" screens shown below.
SALT SIGNAL
LEVELLEVEL
8
7 6
5 4
3 2
t
F, C C
w__FF
CLEAR
SALT SIGNAL
LEVEL LEVEL
8
7
6 5
4
3
2 1
CLEAN
UF_
Figure 27
CLEAN: This feature is beneficial on water supplies containing iron and/or high amounts of sediments
(sand, silt, dirt, etc.). When set to ON, a backwash and fast rinse cycle will occur first, preceding the
normal regeneration sequence. This provides extra cleaning of the resin bed before it is regenerated
with the salt brine. To conserve water, if your water
supply does not contain iron or sediments, be sure
this feature is set to OFF. The default is OFF. Use the A UP or V DOWN buttons to change between
OFF and ON.
3. Press SELECT again to display the "Clean Time" screen shown below.
SALT SIGNAL
LEVEL LEVEL
8
7
6 5
4
3 2
1
CLEAR
CLEAN FEATURE MINUTES: If you have set the Clean Feature ON, the length of the extra backwash
cycle automatically is set to 2 minutes. However, you can adjust this time from 1 to 15 minutes in length.
To change this cycle time, use the /_ UP button to increase the time, or the V DOWN button to short-
en the time. If no change is desired, continue to next step.
MIN
TIME
Figure 28
4. Press SELECT again to display the "97%" screen.
SALT SIGNAL
LEVELLEVEL
8
7
6
5 4
3 2
I
FtF_ F_
UFF
RECHARGE
SALT SIGNAL LEVELLEVEL
8
7
6
5
4
3 2
1
RECHARGE
Figure 29
97°/o FEATURE: The 97% Feature can save salt and water by regenerating when 97% of the softener's capacity has been used up. With this feature ON,
the regeneration can occur at any time (whenever the system has reached 97% of its capacity). The
default is OFF. If this feature is desired, turn it on by pressing the /_ UP button.
5. Press SELECT again to display the "12 or 24 hr"
screen.
SALT SIGNAL
LEVELLEVEL
8
7
6
5
4
3 2
1
_C F
TIME
SALT SIGNAL
PM
LEVELLEVEL
8
7
6
5 4
3 2
1
_"3mt m
C -_F_F
TIME
Figure 30
12 OR 24 HOUR CLOCK: All time displays are shown in standard clock time (1 to 12 AM; and 1 to 12 PM)
at the 12 hr default setting. If 24 hour time format is desired, set to 24 hr by pressing the /_ UP button.
continued on next page
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com