Kenmore 110.6707 User Manual [en, es]

I ■

Electric Diyer

IJs6/ & Ciir© CjuicJcS/

Secadora eléctrica

i¥iC4i
ri ■
Models/Modelos 110.6705í§í, 6706í§í, 6707^ íjí = color number/número de color
TABLE OF CONTENTS
PROTECTION AGREEMENTS
PROTECTION AGREEMENTS..................................................2
WARRANTY...............................................................................3
DRYER SAFETY........................................................................4
INSTALLATION INSTRUCTIONS
Tools and Parts.......................................................................5
Location Requirements ..........................................................5
Electrical Requirements..........................................................7
Electrical Connection..............................................................8
Venting Requirements...........................................................13
Plan Vent System
Install Vent System...............................................................15
Install Leveling Legs
Connect Vent
Level Dryer
Reverse Door Swing.............................................................16
Complete Installation
DRYER USE.............................................................................18
Starting Your Dryer Stopping, Pausing or Restarting
Drying and Cycle Tips...........................................................19
Status Lights
Cycles...................................................................................20
Modifiers...............................................................................21
Options..................................................................................22
Cycle Signal..........................................................................22
Changing Cycles, Modifiers and Options..............................22
Dryer Rack............................................................................23
DRYER CARE.........................................................................24
Cleaning the Dryer Location
Cleaning the Lint Screen.......................................................24
Cleaning the Dryer Interior....................................................24
Removing Accumulated Lint
Vacation and Moving Care....................................................24
Changing the Drum Light
TROUBLESHOOTING SERVICE NUMBERS
.................................................................
.............................................................
........................................................................
...........................................................................
............................................................
...............................................................
.........................................................................
.............................................................
............................................
.............................................
...........................................
.................................................
.................................................
......................................................
BACK COVER
14 15
15 16
17
18 19
20
24
24 25
26
Master Protection Agreements
Congratulations on making a smart purchase. Your new Kenmore® product is designed and manufactured for years of dependable operation. But like all products, it may require
5
preventive maintenance or repair from time to time. That’s when having a Master Protection Agreement can save you money and aggravation.
Purchase a Master Protection Agreement now and protect
yourself from unexpected hassle and expense.
The Master Protection Agreement also helps extend the life of your new product. Here’s what’s included in the Agreement:
✓ Expert service by our 12,000 professional repair specialists ✓ Unlimited service and no charge for parts and labor on all
covered repairs
✓ “No-lemon” guarantee - replacement of your covered
product if four or more product failures occur within twelve months
✓ Product replacement if your covered product can’t be fixed ✓ Annual Preventive Maintenance Check at your request - no
extra charge
Fast help by phone - phone support from a Sears technician
on products requiring in-home repair, plus convenient repair scheduling
✓ Power surge protection against electrical damage due to
power fluctuations
✓ Rental reimbursement if repair of your covered product takes
longer than promised
Once you purchase the Agreement, a simple phone call is all that it takes for you to schedule service. You can call anytime day or night, or schedule a service appointment online.
Sears has over 12,000 professional repair specialists, who have access to over 4.5 million quality parts and accessories. That's
the kind of professionalism you can count on to help prolong the
life of your new purchase for years to come. Purchase your Master Protection Agreement today!
Some limitations and exclusions apply. For prices and additional information, call 1-800-827-6655.
Sears Installation Service
For Sears professional installation of home appliances, garage door openers, water heaters, and other major home items, in the U.S.A. call 1-800-4-MY-HOME®.
KENMORE ELITP APPLIANCE WARRANTY

ONE YEAR LIMITED WARRANTY

When installed, operated and maintained according to all instructions supplied with the product, if this appliance fails due to a defect in material or workmanship within one year from the date of purchase, call 1-800-4-MY-HOME® to arrange for free repair.
If this appliance is used for other than private family purposes, this warranty applies for only 90 days from the date of purchase.
THIS WARRANTY COVERS ONLY DEFECTS IN MATERIAL AND WORKMANSHIP. SEARS WILL NOT PAY FOR:
1.6.Expendable items that can wear out from normal use,
including but not limited to filters, belts, light bulbs, and bags. A service technician to instruct the user in correct product
installation, operation or maintenance. A service technician to clean or maintain this product. Damage to or failure of this product if it is not installed,
operated or maintained according to all instructions supplied with the product.
Damage to or failure of this product resulting from accident, abuse, misuse or use for other than its intended purpose.
Damage to or failure of this product caused by the use of detergents, cleaners, chemicals or utensils other than those recommended in all instructions supplied with the product.
Damage to or failure of parts or systems resulting from unauthorized modifications made to this product.
wmmmmmrmmrmmmmmmmmmm/mm/mm

DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES

Customer’s sole and exclusive remedy under this limited warranty shall be product repair as provided herein. Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. Sears shall not be liable for incidental or consequential damages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, or limitations on the duration of implied warranties of merchantability or fitness, so these exclusions or limitations may not apply to you.
This warranty applies only while this appliance is used in the United States and Canada.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co.
Dept. 817WA, Hoffman Estates, IL 60179
Sears Canada Inc.
Toronto, Ontario, Canada MSB 2B8

PRODUCT RECORD

In the space below, record your complete model number, serial number, and purchase date. You can find this information on the model and serial number label located on the product.
Have this information available to help you obtain assistance or service more quickly whenever you contact Sears concerning your appliance.
Model number_______.
______________________________________ Serial number Purchase date .
_______ _______________ ________________

Save these instructions and your sales receipt for future reference.

DRYER SAFETY

Your safety and the safety of others are very important.

We have provided many important safety messages in this manuai and on your appliance. Aiways read and obey ali safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:

You can be killed or seriously injured if you don't immediately follow instructions.

You can be killed or seriously injured if you don't follow
AWARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
Read all instructions before using the dryer. Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.
Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or explode.
Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.
Before the dryer is removed from service or discarded, remove the door to the drying compartment.
Do not reach into the dryer if the drum is moving. Do not install or store the dryer where it will be exposed
to the weather. Do not tamper with controls.
instructions.
Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.
Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.
Clean lint screen before or after each load. Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust, and dirt.
The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.
See installation instructions for grounding requirements.

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
^ ■c.. i€nts
AWARNING
Flat-blade screwdriver #2 Phillips screwdriver Adjustable wrench that
opens to 1" (2.5 cm) or hex-head socket wrench (for adjusting dryer feet)
Wire stripper (for direct wire installations)
Parts supplied:
Remove parts package from dryer drum. Check that all parts were included.
4 leveling legs
Parts needed:
Check local codes, check existing eiectrical suppiy and venting and see “Eiectrical Requirements” and “Venting Requirements” before purchasing parts.
Mobile home installations require metal exhaust system hardware available for purchase from your local Sears store or Sears Service Center. For further information, please call
1-800-4-MY-HOME® (1-800-469-4663).
Tin snips (new vent
installations)
Level Vent clamps Caulking gun and
compound (for installing
new exhaust vent) Tape measure
w
Explosion Hazard
Keep flammable materials and vapors, such as gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation. Failure to do so can result in death, explosion, or fire.
You will need
■ A location that allows for proper exhaust installation. See “Venting Requirements.”
■ A separate 30-amp circuit.
■ If you are using a power supply cord, a grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See “Electrical Requirements."
■ A sturdy floor to support the total weight (dryer and load) of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered.
■ A level floor with a maximum slope of 1" (2.5 cm) under entire dryer.
Do not operate your dryer at temperatures below 45“E (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door to open fully.
Dryer Dimensions
*Most installations require a minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:
■ Additional spacing should be considered for ease of installation and servicing.
■ Additional clearances might be required for wall, door and
floor moldings.
■ Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered. Additional spacing is required If you exhaust out the rear of
the dryer to either the right or left side.
(73.7 cm)
(2.5 cm)
(2.5 cm) (2.5 cm) (74.3 cm) (12.7 cm)
A
A. Recessed area B. Side view - closet or confined area C. Closet door with vents
B c
* Required spacing
Mobile Home - Additional Installation Requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).
Mobile home installations require:
■ Metal exhaust system hardware, which is available for purchase from your local Sears store or Sears Service Center.
■ Special provisions must be made In mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

fciecitncal I'

:|yirBf'fi€irits

It is your responsibility

■ To contact a qualified electrical installer.
■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances.
The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.
■ To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on fhe serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
■ Do not use an extension cord.
■ If codes permit and a separate ground wire Is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for It here.
■ If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section.
■ This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanentiy connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw {green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.
■ A 4-wlre power supply connection must be used when the appliance is installed In a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:
■ A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.
■ A UL listed strain relief.

If your outlet looks like this:

4-wire receptacle (14-30R)
Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a whife cover.

If your outlet looks like this:

3-wire receptacle (10-30R)
Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:
■ Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.
■ 10-gauge solid copper wire (do not use aluminum).
■ At least 5 ft (1.52 m) long.
GROUNDING INSTRUCTIONS
■ For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
■ For a permanently connected dryer: This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.
WARNING: Improper connection of the equipment
grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS

Electrical Connection

Power Supply Cord Direct Wire
M
Fire Hazard
Use a new UL listed 30 amp power supply cord. Use a UL listed strain reiief. Disconnect power before making electrical connections. Connect neutrai wire (white or center wire) to center
terminal (silver). Ground wire (green or bare wire) must be connected to
green ground connector. Connect remaining 2 supply wires to remaining
2 terminals (gold). Securely tighten all electrical connections. Failure to do so can result In death, fire, or
electrical shock.
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover.
/A B
C D
M
Fire Hazard Use 10 gauge solid copper wire. Use a UL listed strain reiief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center
terminal (silver). Ground wire (green or bare wire) must be connected to
green ground connector. Connect remaining 2 supply wires to remaining
2 terminals (gold). Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
3. Install strain relief.
Style 1: Power supply cord strain relief
■ Remove the screws from a %" {1.9 cm) UL listed strain relief (UL marking on strain relief). Put the tabs of the two clamp sections into the hole below the terminal block opening so that one tab is pointing up and the other is pointing down, and hold In place. Tighten strain relief screws just enough to hold the two clamp sections together.
A. Terminal block cover B. Hold-down screw C. External ground conductor screw D. Center, silver-colored terminal block screw
E. Neutral ground wire F. Hole below terminal block opening
E
F
A. Strain relief tab pointing up B. Hole below terminal block opening C. Clamp section D. Strain relief tab pointing down
B C
D
Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tighf fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point.
Electrical Connection Options
If your home has;

And you will be connecting to:

4-wire receptacle {NEMAtype 14-30R)
A UL listed,
120/240-volt minimum, 30-amp, dryer
( D D ]
power supply cord*

Go to Section:

4-wire connection; Power Supply
Cord

Style 2: Direct wire strain relief

Unscrew the removable conduit connector and any screws from a %" (1.9 cm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief through the hole below the terminal block opening. Reaching Inside the terminal block opening, screw the removable conduit connector onto the strain relief threads.
A. Removable conduit connector B. Hole below terminal block opening C. Strain relief threads
4-wire direct A fused 4-wire connection;
disconnect or circuit breaker
Direct Wire
box*
(12.7 cm)
3-wire receptacle {NEMAtype 10-30R)
A UL listed,
120/240-volt minimum, 30-amp, dryer
3-wire connection: Power Supply
Cord
power supply cord*
3-wire direct
I
---
(8.9 cm)
3V4’—I
A fused disconnect or circuit breaker box*
3-wire connection; Direct Wire
*lf local codes do not permit the connection of a cabinet-ground
conductor to the neutral wire, go to “Optional 3-wire connection” section.

4-wire connection: Power supply cord

IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3-wire connections.
Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable.
4. Now complete installation following instructions for your type of electrical connection:
4-wire (recommended) 3-wire (if 4-wire is not available)
C ^ E
A. 4-wire receptacle (NEMA type 14-30R)
B. 4-prong plug C. Ground prong D. Neutral prong
E. Spade terminals with upturned ends
F. %" (1.9 cm) UL listed strain relief G. Ring terminals
1.2.Remove center silver-colored terminal block screw. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord under center, silver-colored terminal block screw. Tighten screw.
A. Neutral ground wire
B. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center silver-colored terminal block screw. C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)
E. %" (1.9 cm) UL listed strain relief
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Seoure cover with hold-down screw.
7. You have completed your eleofrical connection. Now go to “Venting Requirements.”

4-wire connection: Direct Wire

IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not permit the use of 3 wire connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5" (12.7 cm). Cut VA" (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends of wires info a hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
3. Connect ground wire (green or bare) of power supply cord to external ground conductor screw. Tighten screw.
A. External ground conductor screw B. Neutral ground wire C. Ground wire (green or bare) of power supply cord D. ¥4" (1.9 cm) UL listed strain relief
E. Center silver-colored terminal block screw F. Neutral wire (white or center wire)
4. Connect the other wires to outer terminal block screws. Tighten screws.
1.
Remove center silver-colored terminal block screw.
2.
Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.
10
t f
A. Neutral ground wire B. External ground conductor screw - Dotted line shows
position of NEUTRAL ground wire before being moved to
center sliver-colored terminal block screw. C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)
E. ¥4" (1.9 cm) UL listed strain relief
3. Connect ground wire (green or bare) of direct wire cable to external ground conductor screw. Tighten screw.
1. Loosen or remove center silver-colored terminal block screw.
2. Connect neutral wire (white or center wire) of power supply cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.
A. External ground conductor screw B. Neutral ground wire C. Ground wire (green or bare) of power supply cord D. (1.9 cm) UL listed strain relief
E. Center silver-colored terminal block screw F. Neutral wire (white or center wire)
4. Place the hooked ends of the other direct wire cable wires under the outer terminal blook screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to “Venting Requirements."

3-wire connection: Power suppiy cord

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)
E. (1.9 cm) UL listed strain relief
3. Connect the other wires to outer terminal block screws. Tighten screws.
Tighten strain relief screws. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw. You have completed your electrical connection. Now go to
“Venting Requirements."

3-wire connection: Direct Wire

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved If needed.
Strip 3V2" (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape.
B. 3-wire plug C. Neutral prong D. Spade terminals with upturned ends E. W (1.9 cm) UL listed strain relief F. Ring terminals
G. Neutral wire (white or center wire)
11
When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.
1.2.Loosen or remove center silver-colored terminal block screw. Place the hooked end of the neutral wire (white or center wire)
of direct wire cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do not permit connecting cabinet-ground conductor to neutral wire.
1.2.Remove center silver-colored terminal block screw. Remove neutral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire (white or center wire) of power supply cord/cable under center, silver-colored terminal block screw. Tighten screw.
A. External ground conductor screw B. Neutral ground wire
C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)
E. ¥4 (1.9 cm) UL listed strain relief
3. Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to
“Venting Requirements.”
A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw D. Neutral wire (white or center wire)
E. W (1.9 cm) UL listed strain relief F. Grounding path determined by a qualified electrician
3. Connect the other wires to outer terminal blook screws. Tighten screws.
4.5.Tighten strain relief screws.
Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.
Connect a separate copper ground wire from the external ground conductor screw to an adequate ground.
12

Verting ReqoireiTients

i^WARNING
ш

Fire Hazard

Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can resuit in death
or fire.
■ Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.
■ Do not install flexible metal vent in enclosed walls, ceilings or floors.

Elbows

45° elbows provide better airflow than 90° elbows.
Good Better
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling or a concealed space of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.
Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance.

If this is a new vent system

Vent material

■ Use a heavy metal vent. Do not use plastic or metal foil vent.
■ 4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE™ venting products are recommended.
Clamps
■ Use clamps to seal all joints.
■ Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct. Do not use duct tape.
Clamp
Exhaust
Recommended hood styles are shown here.
A, Louvered hood style B. Box hood style
4" (10.2 cm) heavy metal exhaust vent
DURASAFE™ vent products can be purchased from your dealer. For further information, please call
1-800-4-MY-HOME® (1 -800-469-4663) or visit our website at
www.sears.com.
Rigid metai vent
■ For best drying performance, rigid metal vents are recommended.
■ Rigid metal vent is recommended to avoid crushing and kinking.
Flexible metal vent
■ Flexible metal vents are acceptable only if accessible for cleaning.
■ Flexible metal vent must be fully extended and supported when the dryer is in its final location.
The angled hood style (shown here) is acceptable.
An exhaust hood should cap the vent to keep rodents and insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).
13
Do not use an exhaust hood with a magnetic latch.
Improper venting can cause moisture and iint to collect
indoors, which may result in:
n Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
■ Housecleaning problems and health problems.
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other installations are possible.
B
C
A, Standard rear offset exhaust installation B. Rear exhaust installation to left or right side
h D
E F
G
H
B. Elbow F. Rigid metal or flexible metal vent C. Walt G. Vent length necessary to connect D. Exhaust hood elbows
H. Exhaust outlet
Optional exhaust installations
Venting systems come in many varieties. Select the type best for your installation.
AWARNING
M
Fire Hazard
Cover unused exhaust hole with the following kit: 8212503
Contact your local dealer. Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
D
C. Bottom exhaust installation D. Over-the-top installation (also available with one
offset elbow)
NOTE: The following kits for alternate installations are available
for purchase. For further information, please call
1-800-4-MY-HOME® {1 -800-469-4663).
■ Rear exhaust installation to left or right side: Part Number 8212504
■ Bottom exhaust installation: Part Number 8212503
■ Over-the-Top installation: Part Number 26-49900
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.
This dryer can be converted to exhaust out the bottom. If you prefer, you may contact your local dealer to have the dryer converted. This dryer can also be exhausted from the rear to either the right or left side. Optional kits for these exhaust installations are needed. Refer to the manufacturer’s instructions for kit installation instructions.
14
Determine vent path
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and
turns. When using elbows or making turns, allow as much room as
possible.
Bend vent gradually to avoid kinking. Use the fewest 90° turns possible.

Determine vent length and elbows needed for best drying performance

■ Use the following Vent system chart to determine type of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will:
■ Shorten the life of the dryer.
■ Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will help to achieve the best drying performance.

install Leveling Legs

Excessive Weight Hazard
Use two or more people to move and install dryer. Failure to do so can result in back or other injury.
To protect the floor, use a large, flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer.
Firmly grasp the body of the dryer (not the top or console panel). Gently lay the dryer on the cardboard. See illustration.
3. Examine the leveling legs. Find the diamond marking.
Vent system chart NOTE: Bottom exhaust performance is equivalent to adding two
elbows. To determine maximum exhaust length, add two elbows to the chart.
NOTE: Performance of rear exhaust to either side of the dryer is equivalent to adding one elbow. To determine maximum exhaust length, add one elbow to the chart.
Number of 90“ turns or elbows
0 Rigid metal
1 Rigid metal
2 Rigid metal
3 Rigid metal
4 Rigid metal
Type of vent
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Flexible metal
Box or Louvered hoods
64 ft (20 m) 36 ft (11 m)
54 ft (16.5 m) 31 ft (9.4 m)
44 ft (13.4 m) 27 ft (8.2 m)
35 ft (10.7 m) 25 ft (7.6 m)
27 ft (8.2 m) 23 ft (7 m)
Angled hoods
58 ft (17.7 m) 28 ft (8.5 m)
48 ft (14.6 m) 23 ft (7 m)
38 ft (11.6 m) 19 ft (5.8 m)
29 ft (8.8 m) 17 ft (5.2 m)
21 ft (6.4 m) 15 ft (4.6 m)
4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible.
5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Make sure the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Make sure that there are no kinks in the
flexible gas line.
4. Once the exhaust vent connection is made, remove the corner posts and cardboard.
Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
Run vent to dryer location. Use the straightest path possible. See “Determine vent path” in “Plan Vent System.” Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent.
15
Check the levelness of the dryer. Check levelness first side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or down and check again for
levelness.

Re¥erse Door Swing

You can change your door swing from a right-side opening to a left-side opening, if desired.
i. Place a towel or soft cloth on top of the dryer or work space
to protect the surface.
Remove the door assembly
1. Open the dryer door.
2. Remove the bottom screw from each of the 2 hinges that attach the dryer door to the front panel of the dryer.
3. Loosen the top screw from each of the 2 hinges in Step 2.
5. Remove the 4 plastic plugs located outside the dryer door opening.
6. Install 4 plastic plugs into screw holes in the dryer left when the hinges were removed in Step 4.
Reverse the strike
1. Remove the door strike from the dryer door opening.
2. Remove the cosmetic screw opposite the door strike.
4. Remove the dryer door and the hinges by lifting upward on
the door. Lay the door on a flat, protected surface, with the
inside of the door facing up. Remove remaining 2 loose
screws from dryer front panel.
A. Door strike B. Cosmetic screw
3. Reinstall the door strike and cosmetic screw on the opposite side of the dryer door opening from where they were removed. NOTE: Door strike and plugs must be on the same side of the dryer door opening.
Reinstall the door
1. Remove the 4 screws and 2 hinges from the dryer door.
2. Replace the 4 screws in the same holes.
16
3. Remove the 4 screws from the opposite side of the door.
6. Hang door by placing screw heads into top slotted holes of
hinges and slide door down. Align bottom screw holes in hinge and door. Install two bottom screws. Tighten all hinge screws.
7. Close door to engage door strike.
Install the 2 hinges to the front panel of the dryer using 4 screws. Use the non-slotted side to attach the hinge to the front panel.
Install screws in the top hinge holes in the door. Do not tighten screws. Leave approximately 'A" (5 mm) of screw exposed.
Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.
2.
Check that you have all of your tools.
3.
Dispose of/recycle all packaging materials.
4.
Check the dryer’s final location. Be sure the vent is not crushed or kinked.
5.
Check that the dryer is level. See “Level Dryer.”
6.
For power supply cord installation, plug into an outlet. For direct wire installation, turn on power.
7. Remove any protective film or tape remaining on the dryer. NOTE: Glass door models have a protective film on the
window that should be removed.
8. Read “Dryer Use.”
9. Wipe the dryer drum interior thoroughly with a damp cloth to
remove any dust.
10. Test dryer operation by selecting a Timed Dry heated cycle and starting the dryer. For this test, do not select the Air Only modifier.
If the dryer will not start, check the following:
■ Controls are set in a running or “On” position.
■ Start button has been pushed firmly.
■ Dryer is plugged into an outlet and/or electrical supply
is on.
■ Household fuse is intact and tight, or circuit breaker has
not tripped.
■ Dryer door is closed.
11. When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close the door.
If you do not feel heat, turn off the dryer and check the following:
■ There may be 2 household fuses or circuit breakers for
the dryer. Check that both fuses are intact and tight, or that both circuit breakers have not tripped. If there is still no heat, contact a qualified technician.
NOTE: You may notice an odor when the dryer is first heated. This odor is common when the heating element is first used. The odor will go away.
17
Loading...
+ 39 hidden pages