Keithley 2450 User Manual

SOURCE MEASURE UNITS
The Broadest Choice of SMU Instruments Available
Selector Guide
S
o
u
r
e
M
e
a
s
u
r
e
U
n
i
t
(
S
M
U
)
S
o
u
r
c
e
M
e
t
e
r
®
Precision DMM
Tru e
Current Source
Pulse Generator
Electronic
Load
Precision Power Supply
L
MAKE MULTIPLE MEASUREMENTS ACCURATELY USING A SINGLE INSTRUMENT
A source measure unit (SMU) instrument is a
ve-in-one tool. It combines the useful features of
a digital multimeter (DMM), power supply,
current source, electronic load and pulse generator,
all in a compact form factor. This empowers you to:
• Precisely source and measure voltage and/or current at the same time
• Measure resistance vs. current/voltage directly or indirectly
• Source and measure across a very broad range of current
(100aA to 50A) and voltage (100nV to 3 kV) with 6½ digits of measurement resolution
Run production tests 60% faster and gain up to 10X more throughput
Save time, maximize speed and get jobs done quickly.
WHY A KEITHLEY SOURCE MEASURE UNIT?
For more than 70 years, Tektronix the manufacturer of Keithley SMUs has been
designing, manufacturing and marketing advanced electrical test instruments and systems for
the specialized needs of electronics manufacturers in high performance production testing,
process monitoring, product development and research.
2 |
• Repeatability Guaranteed
High Accuracy and Sensitivity
• Fast and Precise
• Broadest Choices
TEK.COM/KEITHLEY-SOURCE-MEASURE-UNITS
KEITHLEY’S WIDE SELECTION OF SOURCE MEASURE UNIT SMU INSTRUMENTS
Touch, Test, InventTM with a Graphical Touchscreen SMU
245 0 SourceMeter® SMU Instrument .............................................................................4
2460 High Current SourceMeter® SMU Instrument ........................................................... 4
2461 High Current Pulse SourceMeter® SMU Instrument .................................................. 4
2470 High Voltage SourceMeter® SMU Instrument ............................................................ 4
Standard Performance SMUs for the Most Basic Needs
2400 SourceMeter® SMU Instrument ................................................................................ 5
2401 Low Cost SourceMeter
2410 High Voltage SourceMeter® SMU Instrument ........................................................... 5
2420 3 Amp SourceMeter® SMU Instrument ..................................................................... 5
2440 5 Amp SourceMeter® SMU Instrument ..................................................................... 5
High Speed System SMUs for Demanding Applications
2601B/2602B/2604B Single/Dual Channel System SourceMeter® SMU Instrument ......... 6
2611B/2612B/2614B Single/Dual Channel System SourceMeter
2634B/2635B/2636B Low Current Single/Dual Channel System SourceMeter
SMU Instrument ........................................................................... 6
2601B-PULSE System SourceMeter 10μs Pulser/SMU Instrument ................................. 7
®
SMU Instrument ................................................................ 5
®
SMU Instrument ......... 6
®
High Power SMUs with Unprecedented Power, Precision, and Speed
26 51A 50 Amp High Power System SourceMeter® SMU Instrument ................................. 8
2657A 3000 Volt High Power System SourceMeter® SMU Instrument .............................. 8
High Density, More Channels in a Smaller Form Factor
2606B 4-Channel System SourceMeter® SMU Instrument ............................................... 9
Specialty SMUs for Very Low Current and Optoelectronics Testing
6430 Sub-femtoamp Remote SourceMeter® SMU Instrument ..........................................10
2510 TEC SourceMeter® SMU Instrument ........................................................................10
®
2510-AT Autotuning TEC SourceMeter
2520 Pulsed Laser Diode Test System .............................................................................10
Determine which Keithley SMU Is Right For You ........................................ 11
SMU Instrument ................................................10
TEK.COM/KEITHLEY-SOURCE-MEASURE-UNITS
| 3
TOUCH, TEST, INVENT WITH A GRAPHICAL TOUCHSCREEN SMU
2450, 2460, 2461, and 2470 SourceMeter SMU Instruments
Five-inch, high resolution capacitive touchscreen GUI
0.012% basic measure accuracy with 6½-digit resolution
Wide coverage up to 1100 V, 7 A DC, 10A pulse, 1000 W max.
Source and sink (4-quadrant) operation
Dual 1MS/s digitizers for fast sampling measurements (2461 only)
Enhanced sensitivity with 20mV and 10nA source/measure ranges (2450 only)
• Built-in, context-sensitive front panel help
SCPI and Test Script Processor (TSP®) programming modes
Front-panel USB 2.0 memory I/O port for transferring data, test scripts, or testcongurations
Model 2450 2460 2461 2470
Max Current Source/Measure Range 1 A 7 A 10A 1 A Max Voltage Source/Measure Range 200 V 100 V 10 0 V 1000 V Measurement Resolution (Current / Voltage) 10 fA / 10nV 10 pA / 100nV 1 pA / 100nV 10 fA / 100nV
Max Output Power 20 W 100 W 1000 W 20 W
2450
LEARN MORE
2460
LEARN MORE
2461
LEARN MORE
2470
LEARN MORE
Save Time, Maximize Speed, and Get Jobs Done Quickly
SMU models that use familiar graphical interfaces, like icon-based menu structures, are easier to use for all experience levels. You’ll make measurements faster by reducing the learning curve and conguration steps,
enabling you to learn faster, work smarter, and invent easier.
TEK.COM/KEITHLEY-SOURCE-MEASURE-UNITS
4 |
STANDARD PERFORMANCE SMUS FOR THE MOST BASIC NEEDS
Series 2400 SourceMeter SMUInstruments
Five models: 20–100 W DC, 1100 V to 1 μV; single channel
Source and sink (4-quadrant) operation
0.012% basic measure accuracy with 6½-digit resolution
2-, 4-, and 6-wire remote V-source and measure sensing
1700 readings/second at 4½ digits via GPIB
• Pass/Fail comparator for fast sorting/binning
Programmable DIO port for automation/handler/
prober control (except 2401)
Standard SCPI GPIB, RS-232 and Keithley Trigger Link interfaces
LEARN MORE
2400
Model 2400 2401 2410 2420 2440
Max Current Source/Measure Range
Max Voltage Source/Measure Range
Measurement Resolution (Current/Voltage)
Max Output Power 20 W 20 W 20 W 60 W 50 W
1 A 1 A 1 A 3 A 5 A
200 V 20 V 110 0 V 60 V 40 V
1 pA / 100nV 1 pA / 100nV 1 pA / 100nV 10 pA / 100nV 10 pA / 100nV
MORE USEFUL THAN THE COMBINATION OF INDIVIDUAL INSTRUMENTS
SMU VS. POWER SUPPLIES
SMUs can automatically sweep voltage or current to and from negative and positive
outputs when the source crosses zero.
During these operations, there is no need to change test leads.
Output of a SMU can settle to within
0.01% of the specied accuracy in as little as 50 ms.
SMU has higher precision and wider operating ranges.
SMU is a more exible option
VS.
SMU VS. THE DMM AND POWER SUPPLY COMBO
SMU tightly integrates the source and measure capability into one instrument, eliminating the
need for a separate DMM and power supply.
Improves test times, simplies overall test system design and increases usability
SMUs can outperform the DMM and Power
Supply Combo on current vs. voltage (IV)
measurements for a variety of applications.
VS.
TEK.COM/KEITHLEY-SOURCE-MEASURE-UNITS
| 5