Keating Of Chicago PRE-2000, Instant Recovery PRE-2000 Series Series Manual

INSTANT RECOVERY® GAS FRYER SERIES PRE-2000
MANUAL
IMPORTANT:
THE USER'S MANUAL PROVIDES SPECIFIC OPERATING INSTRUCTIONS FOR YOUR MODEL. USE THE INSTANT RECOVERY® GAS FRYER ONLY AS INSTRUCTED IN THIS MANUAL.
KEEP A COPY OF YOUR BILL OF SALE.
The date on the bill establishes the warranty period should service be required. If service is performed, it is in your interest to obtain and keep all receipts.
KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL.
Record the Serial number and Model number of this Instant Recovery® Gas Fryer in the spaces provided. Keep these numbers for future reference.
SERIAL NUMBER
MODEL NUMBER
Keating commercial fryers are not intended for household use.
As continuous product improvement occurs, specifi cations may be changed without notice.
1-800-KEATING | keatingofchicago.com
gasFryerPre2000_2013
10/13
PURCHASER SHOULD POST IN A PROMINENT LOCATION INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS. THIS INFORMATION SHALL BE OBTAINED BY CON­SULTING THE LOCAL GAS SUPPLIER.
WARNING
ShockBurnsGas
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this
Improper installation
can cause damage,
injury or death.
equipment.
WARNING
FOR YOUR SAFETY:
Do not store or use gasoline or other fl ammable vapors or liquids in the vicinity of this or any other appliance.
Do not store
flammable liquids
near this or
any other appliance.
IF NOT INSTALLED, OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANU­FACTURER’S INSTRUCTIONS, THIS PRODUCT COULD EXPOSE YOU TO SUBSTANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEATH OR SERIOUS ILLNESS AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.
PROPANE GAS MAY EVENTUALLY LOSE ITS ODOR AND PRECAUTIONS SHOULD BE TAKEN TO ASSURE THAT PROPANE GAS IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR. IF THERE IS ANY DOUBT, YOU SHOULD CALL YOUR LOCAL PRO­PANE GAS SUPPLIER FOR ASSISTANCE.
THE EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE BASIC PLUMBING CODE OF THE BUILDING OFFICIALS AND CODE ADMINISTRATORS INTERNATIONAL, INC. (BOCA) AND THE FOOD SERVICE SANITATION MANUAL OF THE FOOD AND DRUG ADMINISTRATION (FDA).
9902091 9902091
i
TABLE OF CONTENTS
Important Safety Instructions ............................................ i
INTRODUCTION .............................................................. 1
INSTALLATION
Damage During Shipment ................................................ 1
Safety Precautions .......................................................... 2
FIRST STEPS
National Code Requirement ............................................. 3
Leveling .......................................................................... 3
Restraining Devices .................................................... 3 - 4
Electrical Connection ....................................................... 4
Gas Connection .............................................................. 4
Gas Leak Testing ............................................................. 5
PLACING YOUR KEATING FRYER IN OPERATION
Filling ............................................................................. 5
Lighting ..................................................................... 5 - 6
Melting .......................................................................... 6
Cooking ..................................................................... 6 - 7
Shutdown ....................................................................... 7
GAS FRYER - SERIES PRE-2000
Draining .......................................................................... 7
Cleaning and Boil-Out ................................................. 8 - 9
Electronic Timers ..................................................... 9 - 10
PREVENTATIVE MAINTENANCE
Warranty Repairs .......................................................... 10
Preventive Maintenance Chart ....................................... 10
Oil Breakdown .............................................................. 11
Thermostat Calibration ................................................. 11
Thermostat Bulb Positioning ........................................... 11
Hi-Limit Check ............................................................... 12
SERVICE ...................................................................... 12
SERVICE DIAGNOSIS
Troubleshooting ...................................................... 13 - 15
ORDERING PARTS ........................................................ 15
Warning and Operating Plates......................................... 15
Parts List ............................................................... 16 - 23
Wiring Diagrams ..................................................... 24 - 27
Warranty Information ..................................................... 28
INTRODUCTION
Instructions in this manual should be read thoroughly before attempting to operate this Keating Gas Fryer. All installation and service on Keating equipment must be performed by qualifi ed, certifi ed, licensed and/or authorized installation or service personnel.
Operating information for Keating equipment has been prepared for use by qualifi ed and/or authorized personnel.
Keating equipment is made in the USA and has American sizes of hardware. All metric conversions are approximate.
INSTALLATION INSTRUCTIONS
Proper installation will assure top performance. Alterations of any kind to your equipment will void the warranty. Before uncrating, check equipment carefully for damage.
IF EQUIPMENT ARRIVES DAMAGED
Keating does not assume responsibility for loss or damage incurred in transit.
IMPORTANT
This merchandise has been thoroughly inspected and carefully packed before leaving our plant. Responsibility for its safe delivery was assumed by the carrier at the time of shipment. Claims for loss or damage to the contents should, therefore, be made upon the carrier, as follows:
CONCEALED LOSS OR DAMAGE
the carton may not show external damage. When the damage is discovered upon unpacking, make a writ­ten request for inspection by the carrier’s agent within fi fteen days of the delivery date. Then fi le a claim with the carrier since such damage is the carrier’s respon­sibility. By following these instructions carefully, we guarantee our full support of your claims to protect you against loss from concealed damage.
VISIBLE LOSS OR DAMAGE
Any external evidence of loss or damage must be noted on the freight bill or express receipt, and signed by the carrier’s agent. Failure to adequately de­scribe such external evidence of loss or damage may result in the carrier refusing to honor a damage claim. The form required to fi le such a claim will be supplied by the carrier.
DO NOT RETURN DAMAGED MERCHANDISE TO KEATING. FILE YOUR CLAIM AS STATED ABOVE.
Concealed loss or damage means loss or damage which does not become apparent until the mer­chandise has been unpacked. The contents may be damaged in transit due to rough handling even though
1-800-KEATING |
1
SAFETY PRECAUTIONS
THIS SYMBOL WARNS YOU THAT SERIOUS BURNS OR OTHER INJURIES MAY RESULT IF SAFETY IN­STRUCTIONS ARE NOT FOLLOWED.
• This service manual should be retained in a safe place for future reference. The installation of your new fryer must conform to local codes or in the absence of local codes, with the current National Fuel Gas Code ANSI Z223.1/NFPA 54 (latest edition), Natural Gas Installation Code CAN/CGA-B149.1 or Propane Installation Code CAN/CGA-B149.2.
• Your ventilation hood, when installed, must conform to the current ANSI/NFPA 96 standard (latest edition).
• No frame or restriction shall be constructed around the fryer that will restrict air movement into the fryer’s combustion area or prevent proper ventilation.
• Keating fryers are designed to operate on the gas fuel specified on the serial plate and must not be operated with another gas fuel. They cannot be converted to another gas fuel by turning or engaging a switch.
DO NOT STORE OR USE GASOLINE OR OTHER FLAM­MABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY APPLIANCE.
You will post, in a prominent location, instructions to be followed in the event the user smells gas. This information shall be obtained from your local gas supplier.
IMPORTANT: IN THE EVENT A GAS ODOR IS DE­TECTED, SHUT DOWN UNIT AT MAIN SHUT-OFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR EMERGENCY SERVICE.
• You must maintain this appliance free and clear from combustibles.
• You must maintain the following minimum clearances from combustible and non-combustible construction:
MINIMUM CLEARANCE
CONSTRUCTION CLEARANCES
COMBUSTIBLE NON-COMBUSTIBLE
BACK 6" 0"
RIGHT SIDE 6" 0"
LEFT SIDE 6" 0"
• You must install this appliance at least 16 inches away from any open flame.
• Adequate clearance for servicing and proper operation must be maintained. Your fryer is designed to be serviced from the front.
• Keating commercial fryers are not intended for household use.
• ALWAYS instruct new employees on proper fryer operation.
• A fryer should be operated ONLY by properly trained personnel.
• ALWAYS turn fryer off each night.
• ALWAYS turn fryer off at customer power panel before servicing.
• ALWAYS disconnect fuel source before servicing.
• NEVER leave a fryer unattended during operation.
• NEVER move a fryer when full of hot oil.
• NEVER introduce objects or liquids into fryer, while operational, which are not designed or made for cooking.
• THIS FRYER MAY NOT BE ALTERED, MODIFIED OR CHANGED IN ANY WAY.
The State of California enacted the California Safe drinking water and Toxic Enforcement Act of 1986, (Prop. 65), which “prohibits any person in the course of doing business from knowingly and intentionally exposing any individual to a chemical known to the State of California to cause cancer or reproductive toxicity without first giving clear and reasonable warn­ing to such individuals.” The Governor’s Scientific Advisory Panel added carbon monoxide to the list of hazardous chemicals known to cause reproductive harm.
Carbon monoxide would not be present in concentrations that would pose a “significant risk” to the consumer when the equipment is installed, oper­ated and maintained as follows:
• Installed in accordance with all local codes, or in the absence of local codes, with the current National Fuel Gas Code ANSI Z223.1/NFPA 54 (latest edition).
• Installed under a properly designed operating exhaust hood.
• Connected to the type of gas for which the appliance is manufactured.
• In-line pressure regulator, not supplied by Keating, must be installed outside the appliance to maintain proper incoming gas pressure (7" W.C. Natural, 11" W.C. L.P.).
SUITABLE FOR NON–COMBUSTIBLE FLOORS
| keatingofchicago.com
2
GAS FRYER - SERIES PRE-2000
• Pressure regulator installed in the appliance is adjusted for the manifold pressure marked on the serial plate.
• Adequate air supply to the appliance.
• Inline pressure regulator, not supplied by Keating, must be installed outside the appliance (when needed to maintain the specified manifold pressure marked on the serial plate.
• The equipment is operated in the manner intended using the proper utensils.
• Keep the equipment clean and have it checked periodically.
• Burner air adjustments, mechanical maintenance and repairs must be performed by qualified service personnel.
If the equipment is not installed, operated and main­tained in accordance with the above, concentrations of carbon monoxide in excess of the established limits could be present in the kitchen environment.
ALL PERSONNEL IN THE WORK PLACE WHO MAY BE SUBJECT TO ANY EXPOSURE OF CARBON MONOXIDE MUST BE WARNED OF SUCH POSSIBLE EXPOSURE. THIS WARNING SHOULD BE CONVEYED IN A MANNER SO THAT IT IS CLEARLY UNDERSTOOD BY THE EMPLOYEE, AND THE EMPLOYEE SHOULD BE ASKED IF IN FACT HE OR SHE UNDERSTANDS THE CORRECT METHOD OF OPERATION OF THE EQUIPMENT AND THAT A RISK OF EXPOSURE EXISTS IF THE EQUIPMENT IS OPERATED IMPROPERLY
POSITIONING
The fryer must be no closer than 6 inches from any combustible material and 16 inches away from any open fl ame. The fryer must be placed under an ex­haust hood with a fi re retardant system. Your ventila­tion hood, when installed, must conform to the current ANSI/NFPA 96 standard. ALL connections and place­ment must comply with local and national codes. It is the responsibility of the owner and local installer to comply with these regulations when installing the fryer.
Counter model and fl oor model fryers must be re­strained to prevent tipping when installed in order to avoid splashing, spilling, etc. of hot liquid. The re­straining method may be a manner of installation or by separate means.
LEVELING
The fryer will operate at its highest effi ciency when properly leveled. Place a level on fryer vessel from side to side. For fryers on legs, the bottom foot of the leg is adjustable. Turn counter clockwise to decrease height or clockwise to increase height until level. For fryers on casters, the casters are adjustable by loosening the jam nut and turning the caster in or out. When the desired level is reached, tighten the jam nut. Adjustments of more than 3/4" are not recommended on any caster. The same procedure should be followed to level the fryer from front to back.
Figure 1
Level
FIRST STEPS
NATIONAL CODE REQUIREMENT
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas code, ANSI Z223.1 or the Natural gas Installation Code, CAN/CGA-B149.1 or the Propane Installation Code, CAN/CGA-B149.2. Flexible connectors must comply to ANSI Z221.69/CAN/CGA1.16.
When pressure testing at test pressures less than or equal to 1/2 psig (3.45 KPA), fryer must be isolated from gas supply piping. When pressure testing at test pressures above 1/2 psig (3.45 KPA), fryer must be
disconnected from gas supply piping system.
Leg
Caster
RESTRAINING DEVICES
1. On fryer installations with casters, casters and jam nuts must be completely tightened. Adequate means must be provided to limit the movement of the ap­pliance without depending on the connector and the quick-disconnect device or its associated piping to limit the appliance movement.
Fryer must also be restrained to prevent tipping when installed so that hot liquid splashing is avoided.
1-800-KEATING |
3
NOTICE
2. The restraint means must be attached to the rear of the Keating Gas Fryer within 2" of the cen­ter line width and approximately 1-5/8" from the bottom of the cabinet back to allow the restrain­ing bolt to be anchored to the cabinet back between the cabinet
Restraining devices
required.
bottom and inner liner.
If disconnection of the restraint is necessary, it must
be reconnected when the Keating fryer is returned to its originally installed position.
NOTICE: WHEN THIS APPLIANCE IS INSTALLED WITH CASTERS, IT MUST BE INSTALLED WITH CASTERS SUPPLIED, A CONNECTOR COMPLYING WITH EITHER ANSI Z21.69 OR CAN/CGA-6.16 AND A QUICK-DIS­CONNECT DEVICE COMPLYING WITH EITHER ANSI Z21.41 OR CSA-6.9. IT MUST ALSO BE INSTALLED WITH RESTRAINING MEANS TO GUARD AGAINST TRANSMISSION OF STRAIN TO THE CONNECTOR, AS SPECIFIED IN THE APPLIANCE MANUFACTURER’S INSTRUCTIONS.
ELECTRICAL CONNECTION
The Keating fryer, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, the National Electrical Code, ANSI/NFPA No. 70. or the Canadian Electrical Code, CSAC-22.2 as applicable. A wiring diagram is located on the last page. In the USA and Canada, the electri­cal supply must be 120 VAC, 60 Hz.
Before plugging in the fryer, confi rm the outlet is properly polarized and grounded. If the hot and neutral terminals are reversed or the outlet is not properly grounded, the burners may not ignite (burner on light will go out after 2-1/2 seconds and the ignition pro­cesses will continue 3 times)
.
IF DISCONNECTION OF THE RESTRAINT IS NEC­ESSARY, IT MUST BE RECONNECTED WHEN THE FRYER IS RETURNED TO ITS ORIGINALLY INSTALLED
POSITION.
GAS CONNECTION
• PIPE JOINT COMPOUNDS RESISTANT TO PROPANE GASES MUST BE USED.
• BEFORE OPERATING THIS FRYER, CHECK PIPE JOINTS FOR LEAKS BY USING A SOAP AND WATER SOLUTION ONLY. DO NOT USE AN OPEN FLAME!
ON AN AA OR CMG (MILLIVOLT) FRYER, DO NOT SHORT GAS VALVE TERMINALS WHEN TESTING WIRING AS THERMOSTAT AND GAS VALVE DAMAGE MAY OCCUR AND CAUSE UNSAFE CONDITIONS.
Figure 2
Main Gas Connection
The Keating Instant Recovery® Gas Fryer is equipped with a 9' neoprene covered, 3 wire electrical cord with a three-pronged grounded plug for protection against electrical shock. This plug must be placed into a 120V properly grounded three-pronged polarized outlet. For proper grounding procedures see local codes, or in the absence of local codes, the National Electrical Code ANSI/NFPA 70 (latest edition) or Canadian Elec­trical Code CAN 22.2 (latest edition) as applicable.
NOTE: The electrical wiring diagram for the fryer is located on the inside of the fryer door or in the back of this manual.
WARNING
Plug into a
properly grounded
three-prong receptacle.
THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG 120 VOLT NEMA 5-15 (GROUNDING) PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROP­ERLY GROUNDED AND POLAR­IZED THREE-PRONG RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG.
Connect the fryer to the main gas supply line at the rear of the fryer. The piping should be a minimum of 3/4" NPT supply pipe for a single fryer at the burner manifold. Batteries require larger supply lines. Instal­lation must conform to the current local codes and National Fuel Gas Code (U.S.) ANSI Z223. 1/NFPA 54 (latest edition), Natural Gas Installation Code CAN/ CGA-B149.1 or Propane Installation Code CAN/CGA­B149.2 (latest edition).
A 3/4" NPT manual gas valve is factory installed with each fl oor model fryer (for single fryers and batter­ies), except for 10x11AA – 20AA models which use a 1/2" NPT valve. The required gas pressure for proper operation of each fryer is 4" water column for natural gas and 10" water column for Propane gas at the burner manifold. Remove the allen head test plug on the gas manifold and use a manometer to check the gas pressure.
| keatingofchicago.com
4
GAS FRYER - SERIES PRE-2000
In-line pressure regulators are not supplied by Keat­ing. They are to be provided and installed by others as directed by local codes.
NOTE: If more than one gas fryer is on the same sup­ply line, you may require a larger line. Consult your local gas company to assure adequate volume and pressure. Refer to serial plate for proper gas require­ments for your particular model.
NOTE: Piping for a battery should be at least 1-1/4" to 1-1/2" IPS, depending on total BTU input. Consult your local gas supplier for appropriate battery piping size.
GAS LEAK TESTING
Prior to lighting your fryer:
1. Make sure all thermostats, switches and safety valves are in the “OFF” position.
2. Turn main On/Off manual gas valve to the “ON” position.
3. Have your plumber or gas company check for leaks with a soap solution or sniffer. (NEVER check with an open fl ame!)
4. Have your plumber or gas company representative light the constant pilot. (Not necessary if your fryer has a spark ignitor.)
GAS PRESSURE AT MANIFOLD
NATURAL Gas - 3.0 in. W.C.
LP Gas - 10.0 in. W.C.
NOTE: We recommend that solid shortening not be used in AA and CMG Model fryers as they are not equipped with a melt cycle. If solid shortening is used, it should be melted prior to fi lling the fryer vessel. Damage done by melting solid shortening in the fryer vessel will void the warranty.
BE SURE THE HEAT TRANSFER TUBES ARE COM­PLETELY COVERED WITH OIL BEFORE SWITCHING THE FRYER ON. IF OIL LEVEL DROPS BELOW TOP OF HEAT TRANSFER TUBES, SEVERE DAMAGE TO FRYER AND INJURY TO OPERATOR MAY RESULT.
WATER IN ANY FORM AND HOT OIL DON'T MIX!
OIL EXPANDS WHEN HEATED. THE FILL LEVEL LINE HAS BEEN PROVIDED TO ENSURE OPTIMUM COOK­ING WHILE ENSURING THE SAFETY OF THE OPERA-
TOR. DO NOT OVERFILL THE FRYER VESSEL.
Figure 3
Fill Level Line
MINIMUM INCOMING GAS PRESSURE
NATURAL Gas - 7.0 in. W.C.
LP Gas - 11.0 in. W.C.
NOTE: It is estimated that half of all service calls made on Keating Instant Recovery® Fryer result from an inadequate gas supply. During installation, have a gas company representative make certain that the fryer is receiving adequate gas pressure and volume (see “Installation” or your serial plate on the fryer door).
PROPANE GAS MAY EVENTUALLY LOSE ITS ODOR AND PRECAUTIONS SHOULD BE TAKEN TO ASSURE THAT IT IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR. IF THERE IS ANY DOUBT, YOU SHOULD CALL YOUR LOCAL PROPANE GAS SUPPLIER FOR ASSISTANCE.
OPERATING
FILLING
NOTE: Before fi lling the fryer make certain the fryer
vessel is sanitized, dry and the drain valve is com­pletely closed. Refer to Figure 6 on page 8 for location of drain valve.
A. AA and CMG Models
1. Fill the fryer vessel with oil or MELTED solid shortening up to the “Fill Level” line.
B. BB, TS, CPU and Basket-Lift Models
1. Fill the fryer vessel with oil up to “Fill Level” line. (See Figure 3).
2. If solid shortening is used, remove screen and fi rmly pack solid shortening between the heat transfer tubes. After this has been done and the fryer has been lit, proceed to melting instructions (Page 6) for use of the melt cycle.
LIGHTING
BEFORE ATTEMPTING TO LIGHT THE FRYER, MAKE SURE THE GAS CONNECTIONS ARE SECURE AND HAVE BEEN LEAK TESTED AND THE FRYER HAS BEEN PROPERLY FILLED WITH OIL.
1-800-KEATING |
5
NOTE: For safety purposes, all Hi-Limit controls are
manually reset. Always check the Hi-Limit reset button before attempting to use the fryer. If the Hi-Limit has tripped, the fryer will not operate. (Located behind the fryer door underneath the front panel).
NOTE: For a fryer with a Central or Zero-Space™ Filter, always check the rear drain operating handle before attempting to use the fryer. A safety switch prevents the fryer from operating if the handle is not pushed in completely and latched. (See Figure 4)
Figure 4
A. AA and CMG Models
1. Open the main gas supply to unit (usually at rear) by turning handle in-line with gas piping or hose. Also open manual valve (red gas cock) on gas piping inside unit where applicable.
2. Rotate the tan gas valve knob to the “PILOT” position.
3. Light the constant pilot (located near far left burner) with a match.
4. Set the On/Off switch to the “ON” position.
5. Push in knob and the constant pilot will ignite the runner pilot tube. Hold the knob for 45 seconds and release slowly. If the runner pilot tube fails to stay lit, wait fi ve minutes before attempting to re-light to allow any accumulated gas to escape.
6. After runner pilot tube stays lit, release knob and rotate it to the “ON” position.
7. Set thermostat to desired temperature (325°F - 335°F).
B. BB, TS, CPU and Basket-Lift Models
1. Open main gas supply to unit. Open manual valve (red gas cock) on piping inside unit where applicable.
2. Light the constant pilot (located near far left burner) with a match. If your fryer has an optional spark ignitor, omit this step.
3. Turn on main power On/Off switch to the “ON” position.
4. Set the Fry/Off/Melt switch (BB model) or Cook/ Idle/Melt switch (TS and Basket-Lift models) to the “OFF” (BB) or “IDLE” (TS and Basket-Lift) position.
5. Activate pilot light momentary switch (for runner pilot) and hold about 30 seconds, releasing it after pilot indicating light is illuminated. If the runner pilot tube fails to stay lit, wait 5 minutes before attempting to re-light to allow any accumulated gas to escape.
6. Set the Fry/Off/Melt switch (BB model) or Cook/ Idle/Melt switch (TS and Basket-Lift models) to the “FRY” (BB) or “COOK” (TS and Basket-Lift) position.
7. Set the thermostat to the desired temperature (325°F - 335°F).
NOTE: The fryer cannot be operated during a power failure as the electronic ignition system cannot be
operated.
MELTING
The Keating Melt Cycle safely melts solid shortening in the fryer vessel without scorching.
BEFORE ATTEMPTING TO USE THE FRYER, MAKE SURE THE FRYER HAS BEEN PROPERLY FILLED WITH OIL.
A. BB, TS and Basket-Lift Models
1. Set the thermostat to the desired frying temperature (325°F - 335°F).
2. If using solid shortening, set the Fry/Off/Melt switch (BB Model) or Cook/Idle/Melt switch (TS and Basket-Lift Models) to the “Melt” position. Stay in the “Melt” cycle until the shortening has melted completely and is at the “Fill Level” line before switching to the “Fry” (BB Model) or “Cook” (TS and Basket-Lift Models) position for cooking.
A. CPU Model
See separate fryer instructions or call 1-800-KEATING.
NOTE: During the “Melt” cycle, the burners are on for approximately 5 seconds and off for approximately 55 seconds.
BE SURE THE HEAT TRANSFER TUBES ARE COM­PLETELY COVERED WITH MELTED SHORTENING BEFORE ATTEMPTING TO FRY. IF THE TUBES ARE NOT COMPLETELY COVERED WITH MELTED SHORTENING, SEVERE DAMAGE TO FRYER AND INJURY TO OPERA­TOR MAY RESULT
COOKING
Keating Instant Recovery® Gas Fryers are designed to provide maximum production effi ciency and deliver high quality food products.
Low- temperature cooking, highly polished stainless steel and a true COLD ZONE mean extended oil life. Follow the cooking procedures for your model.
| keatingofchicago.com
6
• OPERATION OF THIS FRYER SHOULD BE LIMITED TO PERSONNEL WHO HAVE BEEN THOROUGHLY TRAINED IN OPERATING PROCEDURES.
• USE ONLY KEATING APPROVED BASKETS IN YOUR FRYER. NEVER OVERFILL FRY BASKETS. DO NOT BANG BASKETS ON BASKET HANGERS OR ON FRYER VESSEL.
GAS FRYER - SERIES PRE-2000
6. Push “start/STOP” button on timers(s). Basket(s) will automatically lower into fryer vessel.
7. When cooking cycle is complete, an audible alarm will sound and the basket(s) will raise automatically. Allow oil to drain before removing baskets.
D. CPU Model
See separate fryer instructions or call 1-800-KEATING.
• CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER TO PREVENT SPLASHING HOT OIL FROM FRYER VESSEL.
• NEVER LIFT BASKETS DIRECTLY OUT OF THE FRYER VESSEL WITHOUT DRAINING, AS SEVERE INJURY MAY RESULT.
A. AA, CMG and BB Models
1. Fill fryer as described on page 5 – Filling.
2. Set thermostat to the desired frying temperature (between 325°F - 335°F).
3. When the oil reaches the desired frying tempera­ture, lower fi lled basket(s) slowly into the hot oil.
4. When cooking cycle is complete, carefully lift basket(s) out of oil and place them on basket hanger rods (on splashback of fryer) to allow draining of excess oil.
B. TS Model
1. Fill fryer as described on page 5 - Filling.
2. Set thermostat to the desired frying temperature een 325°F - 335°F).
(betw
3. When the oil reaches the desired temperature,
the “HEAT” light will go off and the “COOK” light will illuminate.
4. Lower fi lled basket(s) slowly into the hot oil.
5. Set timer for left or right side basket, whichever is
being lowered into oil.
6. When timer(s) sounds, carefully lift basket(s) out of
oil and place them on basket hanger rods (on splash­back of fryer) to allow draining of excess oil.
C. Basket-Lift Model
1. Fill fryer as described on page 5 - Filling.
2. Set thermostat to the desired frying temperature
(between 325°F - 335°F).
3. When the oil reaches the desired temperature,
the “HEAT” light will go off and the “COOK” light will illuminate.
4. Fill basket(s) to proper level and place on upper bar
of lift rod(s).
5. Set timer(s) to desired cooking time using up or
down arrow buttons. For programming timers, see pages 9-10.
SHUT DOWN
A. AA, CMG Models
1. Turn fryer On/Off switch to “OFF” position.
2. Rotate tan gas valve knob to “PILOT” position, push it in slightly, and rotate it to “OFF” position.
B. BB, TS, CPU and Basket-Lift Models
1. Set Fry/Off/Melt switch (BB Model), Cook/Idle/ Melt switch (TS and Basket-Lift Models) or Fry/On/Off switch (CPU Model) to the “OFF” (BB and CPU Models) or “IDLE” (TS and Basket-Lift Models) position.
2. Turn main power On/Off switch to the “OFF” position.
DRAINING
ALWAYS SHUT THE FRYER OFF COMPLETELY BEFORE DRAINING. THE FRYER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL. A DRAIN PIPE AND COVERED CONTAINER SUITABLE FOR USE WITH HOT OIL SHOULD BE USED TO ENSURE THE SAFETY OF THE OPERATOR.
1. Operator should be outfi tted with proper attire including:
– Oil and heat resistant gloves
– Oil and heat resistant apron
– Safety goggles
– Oil and heat resistant footwear
Figure 5
Operator in Safety Gear
1-800-KEATING |
7
Figure 6 - Drain and Drain Valve
Front Drain
Rear Drain
RETURN VALVE
HANDLE
DRAIN VALVE
HANDLE
2. Turn off the fryer and open the door.
3. For front drain fryers, put approved container
under drain valve. For fryers with a central fi lter, slide fi lter drawer in completely.
4. • Front Drain:
Slowly turn handle forward to avoid splashing. The drain will be completely open after 1/4 turn.
• Rear Drain:
Slowly pull drain valve operating handle straight out (unhook from metal latch fi rst).
5. After fryer drains, close the drain valve.
6. Filtering may be done at this step - refer to fi lter
manual.
Figure 7 ­Nutroilator Filter and Fryer
UNDER NO CIRCUMSTANCES SHOULD YOU PERMIT HOT OIL TO COME IN CONTACT WITH WATER OR ICE. ALL DRAINING SHOULD BE DONE UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL. A DRAIN PIPE AND COVERED CONTAINER SUITABLE FOR USE WITH HOT OIL SHOULD BE USED WHENEVER A FRYER IS DRAINED. ALWAYS DRAIN OIL INTO A COVERED RECEPTACLE.
CLEANING AND BOIL-OUT
When cleaning and boiling out your fryer use Keating Sea Powder and Keating Klenzer to keep your fryer in top condition. Keating Sea Powder dissolves any grease build up - even carbonized grease in fryer vessels - one of the leading causes of premature oil breakdown. Once your fryer vessel is clean, use Keating Klenzer, the fi nest dry stainless steel polish available, to restore your Keating Instant Recovery® Gas Fryer’s exterior to its original luster.
Disconnect electric power source before cleaning.
To avoid damaging the fryer, do not power wash, spray or hose it down while cleaning it.
Figure 8
Keating Klenzer and Sea Powder
1. Put on safety attire. See Draining.
2. Turn the fryer off.
3. Drain oil from fryer. Filtering may be done at this step.
4. Remove oil container to a secure area to prevent accidental spillage.
5. Fill fryer vessel to “Fill Level” line with water.
| keatingofchicago.com
8
UNDER NO CIRCUMSTANCES SHOULD THE FRYER BE LEFT UNATTENDED DURING BOIL-OUT. TRAINED PERSONNEL MUST BE PRESENT DURING THE PROCEDURE TO PREVENT BOIL OVER OR TO TURN OFF THE POWER IF WATER DROPS BELOW HEAT TRANSFER TUBES.
6. Set thermostat and turn fryer on to bring water to a gentle boil.
7. Once boil has been reached, turn fryer off.
Loading...