JUMO 901006 User Manual

Page 1
Data Sheet 901006 Page 1/11
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
ww.
Thermocouples for Devices and Plants Inspected/ Tested According to DIN EN 14597
• For heat transmission plants according to DIN 4754
• For temperatures of up to 1500 °C
• As single or double thermocouples
• For water, oil, or air
• For tested control and limitation devices
The thermocouples specified in this data sheet can be used in connection with temperature control and limitation devices tested/inspected according to DIN EN 14597 (DIN 3440) in heat transmission systems according to DIN 4754.
Thermocouples are the preferred choice for measuring temperatures in liquids and gases. Ap­plication areas include heating, furnace/kiln, and apparatus engineering.
Form B terminal heads are suitable for ambient temperatures up to 100 °C. Protection tubes made of various materials protect the measuring insert against chemical influ-
ences and mechanical damage. The appropriate protection tube material is selected according to the conditions on site.
Thermocouples according to DIN EN 60584, class 2 and DIN 43710 are used as the measuring insert.
Changes to the described versions require new design approval.
Important information
: state the part no. from price sheet 901006 when ordering!
For heat transmission plants according
DIN EN 14597
to DIN 4754
For temperatures of up to 1500 °C
As single or double thermocouples
For water, oil, or air
For tested control and limitation devices
2013-02-25/00073486
Page 2
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Dimensions
Data Sheet 901006 Page 2/11
Pos. 1 Pos. 2 Pos. 3
Pos. 4 Pos. 5 Pos. 6
2013-02-25/00073486
Page 3
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Screw-in thermocouples with pipe screw connection and terminal head according to DIN 43729, form B M24 × 1.5
Data Sheet 901006 Page 3/11
Insertion length EL in mm
Nominal length NL in mm
Thread G in inches
Temperature range in °C
Typ e up to February 28, 2013 1 couple
Typ e up to February 28, 2013 2 couples
Typ e as of March 01, 2013
Order code
Stainless steel protection tube X 6 CrNiMoTi 17 12 2, material-no. 1.4571 Thermocouple NiCr-Ni "K"
65 to 670 710 G 1/2 -35 to +550 90.020-F03 - 901006/54-544-1043-15-710-254/000 65 to 670 710 G 1/2 -35 to +550 - 90.020-F02 901006/54-544-2043-15-710-254/000
Thermocouple Fe-CuNi "L"
65 to 670 710 G 1/2 -35 to +550 90.020-F13 - 901006/54-544-1042-15-710-254/000 65 to 670 710 G 1/2 -35 to +550 - 90.020-F12 901006/54-544-2042-15-710-254/000 Operating media: water and oil
Operating pressure: max. 27 bar up to 100 °C, 20 bar up to 400 °C, pressureless as of 400 °C Pos. 1
Versions only for connecting a JUMO safetyM STB/STW Ex type 701155
Insertion length EL in mm
Stainless steel protection tube X 6 CrNiMoTi 17 12 2, material-no. 1.4571 Thermocouple NiCr-Ni "K"
65 to 670 710 G 1/2 -35 to +550 x - 901006/54-544-1043-15-710-254/922 65 to 670 710 G 1/2 -35 to +550 - x 901006/54-544-2043-15-710-254/922
Thermocouple Fe-CuNi "L"
65 to 670 710 G 1/2 -35 to +550 x - 901006/54-544-1042-15-710-254/922 65 to 670 710 G 1/2 -35 to +550 - x 901006/54-544-2042-15-710-254/922 Operating media: water and oil
Operating pressure: max. 27 bar up to 100 °C, 20 bar up to 400 °C, pressureless as of 400 °C Pos. 1
2013-02-25/00073486
Nominal length NL in mm
Thread G in inches
Temperature range in °C
1 couple 2 couples Type
Order code
Page 4
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Screw-in thermocouples with weld-in sleeve and terminal head according to DIN 43729, form B M24 × 1.5
Data Sheet 901006 Page 4/11
Insertion
a
length EL in mm
Length L in mm
Temperature range in °C
Typ e up to February 28, 2013 1 couple
Typ e up to February 28, 2013 2 couples
Typ e as of March 01, 2013
Order code
Steel welding shoulder 15 Mo 3, material-no. 1.5415 Steel protection tube St 35.8, material-no. 1.0305
Thermocouple Fe-CuNi "L"
220 200 -35 to +480 90.111-F01 - 901006/53-543-1042-12-220-815/000 220 200 -35 to +480 - 90.111-F02 901006/53-543-2042-12-220-815/000 Operating media: water and oil
Operating pressure: max. 103 bar up to 100 °C, 30 bar up to 480 °C
Available from stock.
a
Insertion length of the thermocouple
Pos. 2
Versions only for connecting a JUMO safetyM STB/STW Ex type 701155
Insertion
a
length EL in mm
Steel welding shoulder 15 Mo 3, material-no. 1.5415 Steel protection tube St 35.8, material-no. 1.0305
Length L in mm
Thermocouple Fe-CuNi "L"
220 200 -35 to +480 x - 901006/53-543-1042-12-220-815/922 220 200 -35 to +480 - x 901006/53-543-2042-12-220-815/922 Operating media: water and oil
Operating pressure: max. 103 bar up to 100 °C, 30 bar up to 480 °C
a
Insertion length of the thermocouple
2013-02-25/00073486
Temperature range in °C
1 couple 2 couples Type
Order code
Pos. 2
Page 5
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Push-in thermocouple with displaceable stop flange and terminal head according to DIN 43729, form B M24 × 1.5
Data Sheet 901006 Page 5/11
Insertion length EL in mm
Nominal length NL in mm
Temperature range in °C
Typ e up to February 28, 2013 1 couple
Typ e up to February 28, 2013 2 couples
Typ e as of March 01, 2013
Order code
Stainless steel protection tube X 6 CrNiMoTi 17 12 2, material-no. 1.4571 Thermocouple NiCr-Ni "K"
50 to 460 500 -35 to +800 - 90.019-F01 901006/65-547-2043-15-500-668/000 50 to 670 710 -35 to +800 - 90.020-F01 901006/65-547-2043-15-710-668/000 50 to 960 1000 -35 to +800 - 90.021-F01 901006/65-547-2043-15-1000-668/000
Thermocouple Fe-CuNi "L"
50 to 460 500 -35 to +700 - 90.019-F11 901006/65-546-2042-15-500-668/000 50 to 670 710 -35 to +700 - 90.020-F11 901006/65-546-2042-15-710-668/000 50 to 960 1000 -35 to +700 - 90.021-F11 901006/65-546-2042-15-1000-668/000 Operating medium: air
Available from stock. Pos. 3
Versions only for connecting a JUMO safetyM STB/STW Ex type 701155
Insertion length EL in mm
Stainless steel protection tube X 6 CrNiMoTi 17 12 2, material-no. 1.4571 Thermocouple NiCr-Ni "K"
50 to 460 500 -35 to +800 - x 901006/65-547-2043-15-500-668/922 50 to 670 710 -35 to +800 - x 901006/65-547-2043-15-710-668/922 50 to 960 1000 -35 to +800 - x 901006/65-547-2043-15-1000-668/922
Thermocouple Fe-CuNi "L"
50 to 460 500 -35 to +700 - x 901006/65-546-2042-15-500-668/922 50 to 670 710 -35 to +700 - x 901006/65-546-2042-15-710-668/922 50 to 960 1000 -35 to +700 - x 901006/65-546-2042-15-1000-668/922 Operating medium: air
2013-02-25/00073486
Nominal length NL in mm
Temperature range in °C
1 couple 2 couples Type
Order code
Pos. 3
Page 6
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Push-in thermocouple with displaceable stop flange and terminal head according to DIN 43729, form B 15
Data Sheet 901006 Page 6/11
Insertion length EL in mm
Nominal length NL in mm
Diameter D in mm
Temperature range in °C
Typ e up to February 28, 2013 1 couple
Typ e up to February 28, 2013 2 couples
Typ e as of March 01, 2013
Order code
Ceramic protection tube KER 710 Thermocouple NiCr-Ni "K"
420 to 475 500 6 -35 to +1000 - 90.023-F01 901006/66-550-2043-6-500-668/000 275 to 320 355 6 -35 to +1000 - 90.023-F02 901006/66-550-2043-6-355-668/000 170 to 215 250 6 -35 to +1000 - 90.023-F03 901006/66-550-2043-6-250-668/000 Operating medium: air
Available from stock. Pos. 4
Versions only for connecting a JUMO safetyM STB/STW Ex type 701155
Insertion length EL in mm
Ceramic protection tube KER 710 Thermocouple NiCr-Ni "K"
420 to 475 500 6 -35 to +1000 - x 901006/66-550-2043-6-500-668/922 275 to 320 355 6 -35 to +1000 - x 901006/66-550-2043-6-355-668/922 170 to 215 250 6 -35 to +1000 - x 901006/66-550-2043-6-250-668/922 Operating medium: air
2013-02-25/00073486
Nominal length NL in mm
Diameter D in mm
Temperature range in °C
1 couple 2 couples Type
Order code
Pos. 4
Page 7
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Push-in thermocouple with displaceable stop flange and terminal head according to DIN 43729, form B 15
Data Sheet 901006 Page 7/11
Insertion length EL in mm
Nominal length NL in mm
Diameter D in mm
Temperature range in °C
Typ e up to February 28, 2013 1 couple
Typ e up to February 28, 2013 2 couples
Typ e as of March 01, 2013
Order code
Ceramic protection tube KER 710 Thermocouple Pt10Rh-Pt "S"
170 to 215 250 6 0 to 1300 90.021 - 901006/66-880-1044-6-250-668/000 275 to 320 355 6 0 to 1300 90.022 - 901006/66-880-1044-6-355-668/000 420 to 465 500 6 0 to 1300 90.023 - 901006/66-880-1044-6-500-668/000 170 to 215 250 6 0 to 1300 - 90 D 021 901006/66-880-2044-6-250-668/000 275 to 320 355 6 0 to 1300 - 90 D 022 901006/66-880-2044-6-355-668/000 420 to 465 500 6 0 to 1300 - 90 D 023 901006/66-880-2044-6-500-668/000
Thermocouple Pt30Rh-Pt6Rh "B"
170 to 215 250 6 600 to 1500 90.027 - 901006/66-953-1046-6-250-668/000 275 to 320 355 6 600 to 1500 90.028 - 901006/66-953-1046-6-355-668/000 420 to 465 500 6 600 to 1500 90.029 - 901006/66-953-1046-6-500-668/000 170 to 215 250 6 600 to 1500 - 90 D 027 901006/66-953-2046-6-250-668/000 275 to 320 355 6 600 to 1500 - 90 D 028 901006/66-953-2046-6-355-668/000 420 to 465 500 6 600 to 1500 - 90 D 029 901006/66-953-2046-6-500-668/000 Operating medium: air Pos. 5
Versions only for connecting a JUMO safetyM STB/STW Ex type 701155
Insertion length EL in mm
Nominal length NL in mm
Diameter D in mm
Temperature range in °C
1 couple 2 couples Type
Order code
Ceramic protection tube KER 710 Thermocouple Pt10Rh-Pt "S"
170 to 215 250 6 0 to 1300 x - 901006/66-880-1044-6-250-668/922 275 to 320 355 6 0 to 1300 x - 901006/66-880-1044-6-355-668/922 420 to 465 500 6 0 to 1300 x - 901006/66-880-1044-6-500-668/922 170 to 215 250 6 0 to 1300 - x 901006/66-880-2044-6-250-668/922 275 to 320 355 6 0 to 1300 - x 901006/66-880-2044-6-355-668/922 420 to 465 500 6 0 to 1300 - x 901006/66-880-2044-6-500-668/922
Thermocouple Pt30Rh-Pt6Rh "B"
170 to 215 250 6 600 to 1500 x - 901006/66-953-1046-6-250-668/922 275 to 320 355 6 600 to 1500 x - 901006/66-953-1046-6-355-668/922 420 to 465 500 6 600 to 1500 x - 901006/66-953-1046-6-500-668/922 170 to 215 250 6 600 to 1500 - x 901006/66-953-2046-6-250-668/922 275 to 320 355 6 600 to 1500 - x 901006/66-953-2046-6-355-668/922 420 to 465 500 6 600 to 1500 - x 901006/66-953-2046-6-500-668/922 Operating medium: air
2013-02-25/00073486
Pos. 5
Page 8
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Push-in mineral-insulated thermocouples with compensating cable
Data Sheet 901006 Page 8/11
Insertion length EL in mm
Compensating cable length AL in mm
Diameter D in mm
Temperature range in °C
Typ e 1 couple
Typ e 2 couples
Typ e Order code
Sheath cable Inconel 600, material-no. 2.4816 Thermocouple NiCr-Ni "K"
100 5000 2 -35 to +1150 - x 901006/45-551-2043-2-100-11-5000/000 200 2500 2 -35 to +1150 - x 901006/45-551-2043-2-200-11-2500/000 250 5000 2 -35 to +1150 - x 901006/45-551-2043-2-250-11-5000/000 1700 2500 2 -35 to +1150 - x 901006/45-551-2043-2-1700-11-2500/000 Operating media: water and oil
Operating pressure: max. 199 bar up to 100 °C, 188 bar up to 200 °C, 176 bar up to 400 °C
Operating media: air and flue gas Operating pressure: max. 197 bar up to 100 °C, 186 bar up to 200 °C, 175 bar up to 400 °C, 110 bar up to 650 °C, 35 bar up to 900 °C Additional design types from EL 50 to 2000 mm and AL 1000 to 20000 mm upon request.
Pos. 6
Versions only for connecting a JUMO safetyM STB/STW Ex type 701155
Insertion length EL in mm
Sheath cable Inconel 600, material-no. 2.4816 Thermocouple NiCr-Ni "K"
100 5000 2 -35 to +1150 - x 901006/45-551-2043-2-100-11-5000/922 200 2500 2 -35 to +1150 - x 901006/45-551-2043-2-200-11-2500/922 250 5000 2 -35 to +1150 - x 901006/45-551-2043-2-250-11-5000/922 1700 2500 2 -35 to +1150 - x 901006/45-551-2043-2-1700-11-2500/922 Operating media: water and oil
Operating pressure: max. 199 bar up to 100 °C, 188 bar up to 200 °C, 176 bar up to 400 °C
Operating medium: air Operating pressure: max. 197 bar up to 100 °C, 186 bar up to 200 °C, 175 bar up to 400 °C, 110 bar up to 650 °C, 35 bar up to 900 °C Additional design types from EL 50 to 2000 mm and AL 1000 to 20000 mm upon request.
2013-02-25/00073486
Compensating cable length AL in mm
Diameter D in mm
Temperature range in °C
1 couple 2 couples Type
Order code
Pos. 6
Page 9
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Data Sheet 901006 Page 9/11
Allocation list of temperature probes to the respective JUMO devices
For connection to...
JUMO safetyM STB/STW type 701150
The temperature probes are suitable for use according to DIN EN 14597. Based on the test report from TÜV-Nord no. SAS-110-2006TB-2.
Temperature probes for air
Type as of March 01, 2013 Order code
Typ e up to February 28, 2013
901006/65-547-2043-15-500-668/000 90.019-F01 2× NiCr-Ni "K" -35 to +800 ­901006/65-547-2043-15-710-668/000 90.020-F01 2× NiCr-Ni "K" -35 to +800 ­901006/65-547-2043-15-1000-668/000 90.021-F01 2× NiCr-Ni "K" -35 to +800 ­901006/65-546-2042-15-500-668/000 90.019-F11 2× Fe-CuNi "L" -35 to +700 ­901006/65-546-2042-15-710-668/000 90.020-F11 2× Fe-CuNi "L" -35 to +700 ­901006/65-546-2042-15-1000-668/000 90.021-F11 2× Fe-CuNi "L" -35 to +700 -
901006/66-550-2043-6-500-668/000 90.023-F01 2× NiCr-Ni "K" -35 to +1000 ­901006/66-550-2043-6-355-668/000 90.023-F02 2× NiCr-Ni "K" -35 to +1000 ­901006/66-550-2043-6-250-668/000 90.023-F03 2× NiCr-Ni "K" -35 to +1000 -
901006/66-880-1044-6-250-668/000 90.021 1× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-1044-6-355-668/000 90.022 1× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-1044-6-500-668/000 90.023 1× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-2044-6-250-668/000 90D021 2× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-2044-6-355-668/000 90D022 2× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-2044-6-500-668/000 90D023 2× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-953-1046-6-250-668/000 90.027 1× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-1046-6-355-668/000 90.028 1× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-1046-6-500-668/000 90.029 1× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-2046-6-250-668/000 90D027 2× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-2046-6-355-668/000 90D028 2× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-2046-6-500-668/000 90D029 2× Pt30Rh-Pt6Rh "B" 600 to 1500 -
Measuring probe Temperature range
in °C
Weld-in sleeve
901006/45-551-2043-2-100-11-5000/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-200-11-2500/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-250-11-5000/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-1700-11-2500/000 - 2× NiCr-Ni "K" -35 to +1150 -
Temperature probes for water and oil
Type as of March 01, 2013 Order code
Typ e up to February 28, 2013
901006/54-544-1043-15-710-254/000 90.020-F03 1× NiCr-Ni "K" -35 to +550 ­901006/54-544-2043-15-710-254/000 90.020-F02 2× NiCr-Ni "K" -35 to +550 ­901006/54-544-1042-15-710-254/000 90.020-F13 1× Fe-CuNi "L" -35 to +550 ­901006/54-544-2042-15-710-254/000 90.020-F12 2× Fe-CuNi "L" -35 to +550 -
901006/53-543-1042-12-220-815/000 90.111-F01 1× Fe-CuNi "L" -35 to +480 x 901006/53-543-2042-12-220-815/000 90.111-F02 2× Fe-CuNi "L" -35 to +480 x
901006/45-551-2043-2-100-11-5000/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-200-11-2500/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-250-11-5000/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-1700-11-2500/000 - 2× NiCr-Ni "K" -35 to +1150 -
2013-02-25/00073486
Measuring probe Temperature range
in °C
Weld-in sleeve
Page 10
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Data Sheet 901006 Page 10/11
For connection to...
JUMO safetyM TB/TW type 701160 JUMO safetyM TB/TW 08 type 701170 JUMO DICON 500 type 703570 JUMO DICON 501 type 703580
The temperature probes are suitable for use according to DIN EN 14597. Based on the test report from TÜV-Süd no. C-T 1487-00/12.
Temperature probes for air
Type as of March 01, 2013 Order code
Typ e up to February 28, 2013
901006/65-547-2043-15-500-668/000 90.019-F01 2× NiCr-Ni "K" -35 to +800 ­901006/65-547-2043-15-710-668/000 90.020-F01 2× NiCr-Ni "K" -35 to +800 ­901006/65-547-2043-15-1000-668/000 90.021-F01 2× NiCr-Ni "K" -35 to +800 ­901006/65-546-2042-15-500-668/000 90.019-F11 2× Fe-CuNi "L" -35 to +700 ­901006/65-546-2042-15-710-668/000 90.020-F11 2× Fe-CuNi "L" -35 to +700 ­901006/65-546-2042-15-1000-668/000 90.021-F11 2× Fe-CuNi "L" -35 to +700 -
901006/66-550-2043-6-500-668/000 90.023-F01 2× NiCr-Ni "K" -35 to +1000 ­901006/66-550-2043-6-355-668/000 90.023-F02 2× NiCr-Ni "K" -35 to +1000 ­901006/66-550-2043-6-250-668/000 90.023-F03 2× NiCr-Ni "K" -35 to +1000 -
Measuring probe Temperature range
in °C
Weld-in sleeve
901006/66-880-1044-6-250-668/000 90.021 1× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-1044-6-355-668/000 90.022 1× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-1044-6-500-668/000 90.023 1× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-2044-6-250-668/000 90D021 2× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-2044-6-355-668/000 90D022 2× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-2044-6-500-668/000 90D023 2× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-953-1046-6-250-668/000 90.027 1× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-1046-6-355-668/000 90.028 1× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-1046-6-500-668/000 90.029 1× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-2046-6-250-668/000 90D027 2× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-2046-6-355-668/000 90D028 2× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-2046-6-500-668/000 90D029 2× Pt30Rh-Pt6Rh "B" 600 to 1500 -
901006/45-551-2043-2-100-11-5000/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-200-11-2500/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-250-11-5000/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-1700-11-2500/000 - 2× NiCr-Ni "K" -35 to +1150 -
Temperature probes for water and oil
Type as of March 01, 2013 Order code
Typ e up to February 28, 2013
901006/54-544-1043-15-710-254/000 90.020-F03 1× NiCr-Ni "K" -35 to +550 ­901006/54-544-2043-15-710-254/000 90.020-F02 2× NiCr-Ni "K" -35 to +550 ­901006/54-544-1042-15-710-254/000 90.020-F13 1× NiCr-Ni "K" -35 to +550 ­901006/54-544-2042-15-710-254/000 90.020-F12 2× NiCr-Ni "K" -35 to +550 -
Measuring probe Temperature range
in °C
Weld-in sleeve
901006/53-543-1042-12-220-815/000 90.111-F01 1× Fe-CuNi "L" -35 to +480 x 901006/53-543-2042-12-220-815/000 90.111-F02 2× Fe-CuNi "L" -35 to +480 x
901006/45-551-2043-2-100-11-5000/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-200-11-5000/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-250-11-5000/000 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-1700-11-5000/000 - 2× NiCr-Ni "K" -35 to +1150 -
2013-02-25/00073486
Page 11
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road East Syracuse, NY 13057, USA Phone: 315-437-5866
1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com
Data Sheet 901006 Page 11/11
For connection to...
JUMO safetyM STB/STW Ex type 701155
The temperature probes are suitable for use in potentially explosive areas according to DIN EN 14597. Based on the test report from TÜV-Nord no. 12 203 556139.
Temperature probes for air
Type as of March 01, 2013 Order code
Typ e up to February 28, 2013
901006/65-547-2043-15-500-668/922 - 2× NiCr-Ni "K" -35 to +800 ­901006/65-547-2043-15-710-668/922 - 2× NiCr-Ni "K" -35 to +800 ­901006/65-547-2043-15-1000-668/922 - 2× NiCr-Ni "K" -35 to +800 ­901006/65-546-2042-15-500-668/922 - 2× Fe-CuNi "L" -35 to +700 ­901006/65-546-2042-15-710-668/922 - 2× Fe-CuNi "L" -35 to +700 ­901006/65-546-2042-15-1000-668/922 - 2× Fe-CuNi "L" -35 to +700 -
901006/66-550-2043-6-500-668/922 - 2× NiCr-Ni "K" -35 to +1000 ­901006/66-550-2043-6-355-668/922 - 2× NiCr-Ni "K" -35 to +1000 ­901006/66-550-2043-6-250-668/922 - 2× NiCr-Ni "K" -35 to +1000 -
901006/66-880-1044-6-250-668/922 - 1× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-1044-6-355-668/922 - 1× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-1044-6-500-668/922 - 1× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-2044-6-250-668/922 - 2× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-2044-6-355-668/922 - 2× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-880-2044-6-500-668/922 - 2× Pt10Rh-Pt "S" 0 to 1300 ­901006/66-953-1046-6-250-668/922 - 1× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-1046-6-355-668/922 - 1× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-1046-6-500-668/922 - 1× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-2046-6-250-668/922 - 2× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-2046-6-355-668/922 - 2× Pt30Rh-Pt6Rh "B" 600 to 1500 ­901006/66-953-2046-6-500-668/922 - 2× Pt30Rh-Pt6Rh "B" 600 to 1500 -
Measuring probe Temperature range
in °C
Weld-in sleeve
901006/45-551-2043-2-100-11-5000/922 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-200-11-2500/922 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-250-11-5000/922 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-551-2043-2-1700-11-2500/922 - 2× NiCr-Ni "K" -35 to +1150 -
Temperature probes for water and oil
Type as of March 01, 2013 Order code
Typ e up to February 28, 2013
901006/54-544-1043-15-710-254/922 - 1× NiCr-Ni "K" -35 to +550 ­901006/54-544-2043-15-710-254/922 - 2× NiCr-Ni "K" -35 to +550 ­901006/54-544-1042-15-710-254/922 - 1× Fe-CuNi "L" -35 to +550 ­901006/54-544-2042-15-710-254/922 - 2× Fe-CuNi "L" -35 to +550 -
901006/53-543-1042-12-220-815/922 - 1× Fe-CuNi "L" -35 to +480 x 901006/53-543-2042-12-220-815/922 - 2× Fe-CuNi "L" -35 to +480 x
901006/45-552-2043-2-100-11-5000/922 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-552-2043-2-200-11-2500/922 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-552-2043-2-250-11-5000/922 - 2× NiCr-Ni "K" -35 to +1150 ­901006/45-552-2043-2-1700-11-2500/922 - 2× NiCr-Ni "K" -35 to +1150 -
2013-02-25/00073486
Measuring probe Temperature range
in °C
Weld-in sleeve