Julabo F12-MA Data Sheet

Product data sheet 1/3
F12-MA Refrigerated/Heating Circulator
The general all-rounder for a broad spectrum of requirements
JULABO Refrigerated & Heating Circulators for heating and cooling are suitable for external temperature tasks and for temperature applications directly in the bath. A model from three different series’ with different capacities can be selected. Powerful circulating pump systems and high heating and cooling capacities guarantee short heat-up and cool-down times. The inevitable dust accumulation that occurs in refrigeration systems is solved by means of an easily removed venting grid, which allows for easy cleaning. Depending on the model, the units are equipped with handles or castors for an easy transportation. All models have a drain screw on the front allowing the fluid to be drained easily. The compact assembly of each unit enables space to be saved in the laboratory.
Your advantages
MULTI-DISPLAY (LED) for actual and setpoint values, warning/safety functions and pump stage Keypad for setpoints, warning/safety values and menu functions PID2 temperature control with drift compensation ATC3 3-Point-Calibration Early warning system for low liquid level (DBGM 203 06 059.8) Adjustable high temperature cut-out, visible via display RS232 interface for online communication SMART PUMP electronically adjustable pump stages Active Cooling Control
F12-MA
Technical Data
Order No. 9153612 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -20 ... +200 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 1 Cooling capacity (Medium Ethanol) °C 20 0 -20
kW 0.2 0.12 0.02 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (psi) 3.3-6.5 Bath opening / bath depth (W x L / D inch) 5.1 x 5.9 / 5.1 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume liters 4.5
Product data sheet 2/3
F12-MA
Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 55 Global Warming Potential for 1430 Carbon dioxide equivalent stage 1 (t) 0.079 Digital interface RS232
Optional: Profibus Ambient temperature 5...40 °C Dimensions W x L x H (inch) 7.9 x 14.2 x 22 Weight (LBS) 51 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia.
(pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 115/60/12 Available voltage versions 230 V / 50 Hz
115 V / 60 Hz
230 V / 60 Hz
100 V / 50 - 60 Hz
Characteristics
Display
Several values at a glance
Large Multi-Display (LED), easy to read across the room, for actual value and up to 3 setpoints, warning functions, high temperature cut-off, selected pump stages (resolution
0.01/0.1 °C)
Operation
Comfortable and detailed
Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc.
Temperature Control
Highly precise
PID Temperature control with drift compensation and adjustable control parameters, temperature stability ±0.01...±0.02 °C
Highest measuring accuracy
Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
Refrigeration Technology
Consistent cooling capacity
Easily removable venting grid for quick and easy cleaning
100 % Cooling capacity
Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
Technical Features
Clever pump system
Reliable and consistent pump capacity, electronically adjustable pump stages
Serial connection
RS232 interface for PC connection, e.g. for data communication and recording of measured values
Warning & Safety Functions
Early warning system for low liquid level
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
Early warning system for high/low temperature limits
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Enhanced protective functions
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments