Jenn-Air JGC9536BDS Installation Instruction

INSTALLATION INSTRUCTIONS
30" (76.2 CM) AND 36" (91.4 CM)
GAS BUILT-IN COOKTOP
INSTRUCTIONS D'INSTALLATION
DE LA TABLE DE CUISSON À GAZ ENCASTRÉE DE
30" (76,2 CM) ET 36" (91,4 CM)
Table of Contents/Table des matières
INSTALLATION REQUIREMENTS................................................2
Tools and Parts ............................................................................2
Location Requirements................................................................3
Electrical Requirements ...............................................................4
Gas Supply Requirements...........................................................5
INSTALLATION INSTRUCTIONS..................................................6
Install Cooktop .............................................................................6
Make Gas Connection .................................................................6
Complete Installation ...................................................................8
SÉCURITÉ DE LA TABLE DE CUISSON ......................................9
EXIGENCES D'INSTALLATION...................................................10
Outillage et pièces......................................................................10
Exigences d'emplacement.........................................................10
Spécifications électriques ..........................................................12
Spécifications de l'alimentation en gaz .....................................12
INSTRUCTIONS D'INSTALLATION.............................................14
Préparation de la table de cuisson pour l'installation................14
Raccordement au gaz................................................................14
Achever l'installation ..................................................................16
COOKTOP SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
IMPORTANT:
Installer: Leave installation instructions with the homeowner. Homeowner: Keep installation instructions for future reference.
follow instructions.
can be killed or seriously injured if you don't
You instructions.
follow
IMPORTANT :
Installateur : Remettre les instructions d'installation au propriétaire. Propriétaire : Conserver les instructions d'installation pour référence ultérieure.
W10203804B
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions. If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell. Gas suppliers recommend that you use a gas detector approved by UL or CSA. For more information, contact your gas supplier. If a gas leak is detected, follow the “What to do if you smell gas” instructions.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
If using a ball valve, it shall be a T-handle type.
A flexible gas connector, when used, must not exceed 3 feet.
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Too ls n ee ded
Tape measure
Flat-blade screwdriver
¹⁵⁄₁₆" combination wrench
Pipe wrench
Wrench or pliers
Marker or pencil
Pipe-joint compound
resistant to LP gas
Noncorrosive leak-detection
solution
Parts supplied
Gas pressure regulator
Burner grates
Burner caps
Parts needed
Check local codes and consult gas supplier. Check existing gas supply and electrical supply. See “Electrical Requirements” and “Gas Supply Requirements” sections.
2
Location Requirements
C
C
IMPORTANT: Observe all governing codes and ordinances. Do not obstruct flow of combustion and ventilation air.
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The model/serial rating plate is located on the underside of the cooktop base.
A
A. Model/serial rating plate
Mobile Home - Additional Installation Requirements
The installation of this cooktop must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this cooktop must conform with the current standards CAN/CSA-A240-latest edition, or with local codes.
Product Dimensions
30" (76.2 cm) Model
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
The cooktop must be a specified cooktop that is approved to
be installed either alone or over an undercounter built-in oven. Check the cooktop base approved installation label for your cooktop model number and approved combinations of cooktops and ovens that can be installed. If you do not find this label, your cooktop may not be approved for use over an undercounter built-in oven. Contact your dealer to confirm that your cooktop is approved.
Ovens approved for this type of installation will have an
approval label located on the top of the oven. If you do not find this label, contact your dealer to confirm that your oven is approved. Refer to oven manufacturer’s Installation Instructions for approval for built-in undercounter use and proper cutout dimensions.
The cooktop should be installed in a location away from
strong draft areas, such as windows, doors and strong heating vents or fans.
All openings in the wall or floor where cooktop is to be
installed must be sealed.
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
Grounded electrical supply is required. See “Electrical
Requirements” section. Proper gas supply connection must be available. See “Gas Supply Requirements” section.
The cooktop is designed to hang from the countertop by its
side or rear flanges.
The gas and electric supply should be located as shown in
“Cabinet Dimensions” section so that they are accessible without requiring removal of the cooktop.
Provide cutout in right rear corner of cutout enclosure as
shown to provide clearance for gas inlet, power supply cord, and to allow the rating label to be visible.
IMPORTANT: To avoid damage, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage.
D
36" (91.4 cm) Model
D
A
E
A. 30" (76.2 cm) B. 21½" (54.6 cm) C.3
¹³⁄₁₆
" (9.7 cm) D. 5¼" (13.3 cm) E. 12¼" (31.1 cm)
A
E
⁵⁄₁₆
A. 35 B. 21" (53.3 cm) C.3
¹³⁄₁₆
" (9.7 cm) D. 5¼" (13.3 cm) E. 15¼" (38.7 cm)
B
B
" (89.7 cm)
3
Cabinet Dimensions
IMPORTANT: If installing a range hood or microwave hood
combination above the cooktop, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
A
C
M
B
K
F
E
L
J
A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models B. Combustible area above countertop (shown by dashed
box above)
C. 30
" (76.2 cm) minimum clearance between top of cooktop
platform and bottom of uncovered wood or metal cabinet
" [61 cm] minimum clearance if bottom of wood or metal
(24 cabinet is covered by not less than millboard covered with not less than No. 28 MSG sheet steel, 0.015
" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
0.024
" (33 cm) recommended upper cabinet depth
D. 13
¹⁄₈
" (5.4 cm)
E. 2
F. 1 9
¹⁵⁄₁₆
G. 18" (45.7 cm) minimum clearance from upper cabinet to
H. Grounded outlet - Locate within 24" (61 cm) of right rear
M. 23
" (50.6 cm)
countertop within minimum horizontal clearances to cooktop
corner of cutout (with no undercounter built-in oven installed below cooktop)
I. 28½" (72.4 cm) on 30" models; 34½" (87.6 cm) on 36" models
J. 6" (15.2 cm) minimum distance to nearest left and right side
combustible surface
K. 1" (2.5 cm) minimum distance to rear combustible surface
L. Gas line opening - Wall: Anywhere 6" (15.2 cm) below
underside of countertop. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall is recommended (with no undercounter built-in oven installed below cooktop)
¹⁄₁₆
" (58.6 cm) minimum countertop depth is required
" [0.04 cm] stainless steel, or
I
¹⁄₄
D
G
H
" [0.6 cm] flame retardant
Electrical Requirements
IMPORTANT: The cooktop must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system that will not operate if plugged into an outlet that is not properly polarized.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
J
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is
required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded.
The wiring diagrams are provided with this cooktop. See
“Wiring Diagrams” on a separate sheet.
NOTES: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the countertop to the top of the drawer (or other obstruction) in base cabinet is required. The drawer depth may need to be shortened to avoid interfering with the regulator.
IMPORTANT: If an undercounter built-in wall oven is to be installed below this cooktop, the grounded outlet (H) and gas supply piping must be located in an adjacent cabinet.
This cooktop and its gas and electrical supply sources must be installed before the undercounter built-in wall oven is installed.
4
Gas Supply Requirements
WARNING
Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include: licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances. IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest edition.
IMPORTANT: Leak testing of the cooktop must be conducted according to the manufacturer’s instructions.
Gas Supply Line
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the
cooktop location. A smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON ½" minimum. Usually, LP gas suppliers determine the size and materials used in the system.
Flexible metal appliance connector:
If local codes permit, use a ¹⁄₂" or ³⁄₄" I.D. flexible stainless
A ½" male pipe thread is needed for connection to the
Do not kink or damage the flexible metal tubing when
Rigid pipe connection: The rigid pipe connection requires a combination of pipe
fittings to obtain an in-line connection to the cooktop. The rigid pipe must be level with the cooktop connection. All strains must be removed from the supply and fuel lines so cooktop will be level and in line.
®†
tape. With LP gas, piping or tubing size should be
steel tubing gas connector, designed by CSA to connect the cooktop to the rigid gas supply line.
female pipe threads of the inlet to the cooktop pressure regulator.
moving the cooktop.
Type of Gas
Natural Gas:
This cooktop is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas.
This cooktop is factory set for use with Natural gas. If
converting to LP gas, see the “LP Gas Conversion” instructions provided in the package containing literature. The model/serial rating plate located on the underside of the cooktop base has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP Gas Conversion:
Conversion must be done by a qualified service technician. No attempt shall be made to convert the cooktop from the gas
specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See the Gas Conversion instructions provided in the package containing literature.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve should be located in the same room but external to the cooktop. It must be accessible without removing the cooktop, and it should be in a location that allows ease of opening and closing. Do not block access to shutoff valve. The valve is for turning on or shutting off gas to the cooktop.
B
A
C
A. Gas supply line B. Shutoff valve “open” position C. To cooktop
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
5
Loading...