Jenn-Air JEC0530 User Manual

0 (0)
INSTALLATION
Radiant Cooktop
INSTRUCTIONS
Models JEC0530 & JEC0536
403 WEST FOURTH STREET, NORTH D NEWTON, IA 50208
IMPORTANT - SAVE FOR THE LOCAL ELECTRICAL INSPECTOR’S USE
IMPORTANT: Installation should be performed only by an authorized Jenn-Air Service Contractor or other qualified
installer. Read safety precautions in the Use & Care Manual before using this appliance.
(Dimensions shown in both inches and centimeters)
JEC0530
FOUR-ELEMENT RADIANT COOKTOPS
DIMENSIONS
A 29-1/16 + B20-3/8+ C2-1/8 5.4 D 4-1/4 min. clear 10.8 E 29-15/16 76.0 F 21-1/2 54.6 G3-5/8 7.6
FIGURE 1
1/16 74.0 + 0.2
1/16 51.9 + 0.2
D
NOTE: “D” is clearance needed for unit depth measure down from top of countertop. Typical for all units.
JEC0536
FIVE-ELEMENT RADIANT COOKTOPS
DIMENSIONS
A 34-9/16 + B20-3/8+ C2-1/8 5.4 D 4-1/4 min.clear 10.8 E 35-5/16 89.7 F 21-1/2 54.6 G3-5/8 7.6
1/16 87.9 + 0.2
1/16 51.9 + 0.2
IMPORTANT
CUTOUT
FIGURE 2
UNITS PROVIDED WITH 1/2² (1.3 cm) I.D. FLEXIBLE CABLE 48² (121.9 cm) LONG WITH 6² (15.2 cm) WIRE LEADS AT END, FURNISHED AND INSTALLED BY MANUFACTURER (CONNECT TO 240 VOLT ELECTRICAL SERVICE).
DIMENSIONS ARE
CRITICAL
INSTRUCTIONS TO INSTALLER:
S Side and Back Wall Clearance: Unit may be safely installed as near as 2 1/2 inches (6.35 centimeters) from side
walls and 3/4 inch (1.91 centimeters) from back wall.
Notice To Installer: Leave these instructions with the appliance.
Notice To Consumer: Retain these instructions for future reference.
8101P645-60
(03-04-00)
Installing Cabinetry Over Your Cooktop
A= 30²²²² (76.2 cm) minimum
clearance between the top of the cooktop and the bottom of an unprotected wood or metal cabinet.
A= 24²²²² (60.96 cm) minimum when
bottom of wood or metal cabinet is protected by not less than 1/4² (0.635 cm). FLAME RETARDANT millboard covered with not less than no. 28 MSG sheet steel, 0.015² (0.038 cm) stainless steel, 0.024² (0.061 cm) aluminum or copper.
* To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets.
Important Installation Suggestions
1. Chamfer all exposed edges of decorative laminate to prevent damage from chipping.
2. Radius corners of cutout and file to insure smooth edges and prevent corner cracking.
3. Rough edges, inside corners which have not been rounded and forced fits can contribute to cracking of the countertop laminate.
4. Countertop must be supported within 3² (7.62 cm) of cutout.
CAUTION
Warrantyis void onequipment installed other than as recommended by manufacturer.
Electrical Wiring Information
If used on new branch-circuit installations (1996 NEC), mobile homes, recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor, connect the ground wire to ground in accordance with local code. Connect all wires to the branch circuit with approved connectors. Use copper or aluminum wire. If aluminum wire is used, use connectors recognized for joining aluminum to copper.
CAUTION
This is a two wirewith copper ground 208/240volt AC appliance. Copper ground is chassis ground and must be connected to supply ground.
National Electrical Code, NFPA No. 70, can be obtained by writing to:
National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
This is a 2-wire, 240-volt unit. Connect only to a 3-wire, 120/240-volt power supply; the neutral conductor is not required for the operation of the appliance. The potential at the power supply electrical connections shall be 150-volts-to-ground or less. The grounding (bare) wire is connected to the frame of the unit; connect it to a separate ground. The chart below recommends the minimum circuit protector and wire size if the appliance is the only unit on the circuit. If smaller sizes of wire are used, the unit efficiency will be reduced and a fire hazard may be created. It is advisable that the electrical wiring and hookup be accomplished by a competent electrician.
RECOMMENDED MINIMUM
K.W.RATING CIRCUIT PROTECTION WIRE SIZE
ON SERIAL PLATE IN AMPRES (AWG)
0-4.8 20 12
4.9 - 6.9 30 10
7.0 - 9.9 40 8
10.0 - 11.9 50 8
12.0 - 14.9 60 6
Notice To Installer
Follow accompanying instruction carefully.
Preparation Of Countertop
The cutout in the countertop into which the appliance is to be installed should be prepared according to the cutout dimensions given on page 1 of these instructions.
CAUTION
Cutout dimensions are critical. Dimensions must be measured and cut accurately to within +
1/16²
(.16 cm) to insure proper fit.
Installation Of Appliance
1. Remove the cooktop from the carton.
2. Provide cutout in countertop as required per page 1.
3. Place unit in the cutout.
4. Optional - Foam Tape Installation - see illustration figure 3. Apply foam tape to cook top as shown in figure 3 if counter top is not flat.
5. Make electrical wire connection to unit. Consult local codes for proper power hook-up.
6. Test to insure touch controls operate all elements properly.
Proper Electrical Supply
You must provide an adequate electrical supply system as required for your cooktop. All wire connections must be in accordance with local codes and properly insulated. Check with local utility for governing electrical codes and ordinances. In the absence of local electrical codes, the National Electrical Code, NFPA No. 70, governing electric range installations must be followed. A copy of the
FIGURE 3
2