Jenn-AirDualFuel
UpdraftSlide-In Range
Cuisini6reencastrable_ deux6nergies _ circulationascendanteJenn-Air/
Estufadeslizantededoblecombustiblede corrienteascendenteJenn-Air
.f
Printed in USA ©2005 MaytagCorporation Rev0-10/05 8101P698-60
Jenn-AirDualFuelUpdraftSlide-InRange
PLEASEKEEPTHIS MANUALFORFUTUREREFERENCE
Only qualified personnel should install or service this range.
Read "Safety Instructions" in Use & Care book before using range.
Improper installation, adjustment, alteration, service, maintenance or use of range can result in serious injury or property damage.
Installer, take care not to damage flooring.
S
Donot lift or moverangebygraspingdoor handles,main
top, or backguard.
,Arisk of rangetip-over exists if the appliance is not installed in accordance with the
providedinstallation instructions. The proper use of the ANTI-TIPdevice minimizes
the risk of TIP-OVER.Inusingthis device the consumer must still observethe safety
precautionsasstated inthe USEandCAREMANUALand avoid using the ovendoors
Thisrangehasbeendesignedin accordancewith the
requirementsof varioussafety agenciesandcomplies
with the maximumallowable woodcabinet temperatures of 194°EIfthis range is installedwith
cabinetsthat havea lower working temperature than 194°F,discoloration,delaminationor melting may occur.
Placerange in a well lit area.Donot setrange over holesin the floor or other locationswhere it may be
subject to strong drafts. Anyopening in the wa I behind the rangeandinthe floor underthe rangeshould be
sealed.Makesure theflow of cooling/ventilationair is not obstructed below the range. Note:A rangeshould
NOTbe installed over kitchen carpeting. HighAltitudeNotice:Thespecified gasburner ratings
typically applyto e!evatonsupto 2000 feet. For higher
a!titudes,the rates mayneedtobe reducedto achieve satisfactoryoperation.Alocal certified gasservicer will
be ableto adviseif a reduction is necessary, RequirementsforPropane,AppliancesandEquipmentinR.V.'s(CS,AStandard
as a step stool. Installation instructions are providedfor woodand cement in either floor or wall. Anyother type of construction may require special installation techniques as deemed necessaryto provide adequate fastening of the ANTI-TIP
bracketto the floor or wall. The bracket may be installed to engage the LEFTor RIGHTrear leveling foot. NOTE:The bracket provided is designed for use with flush mount and non-flush mount outlet receptacles. Install the bracket with the
orientation hole in the longer leg against the wall or floor as shown insteps 14-19.
MOBILEHOMES
The installation of a range designed for mobile homeinstallation must conform with the Manufactured HomeConstructionand SafetyStandard,Title24 CFR,Part 3280
(formerlythe Federal Standardfor Mobile HomeConstructionand Safety,Title24 HUD,Part280)or,when such standardis not applicable,theStandardfor Manufactured HomeInstallationsANSIA225.1/NFP,A501,A,or with local codes. InCanadathe range
must be installed in accordancewith the current CS,AStandardC22.1- Canadian Electrical Code Part 1 and Section Z240.4.1 - Installation Requirementsfor Gas
Burning,Appliancesin MobilHomes(CS,AStandard C,AN/CS,A- Z240MH).
RECREATIONALPARKTRAILERS
The installation of a range designed for recreational parktrailers must conform with state or other codes or,in the absenceof suchcodes,with the Standard for
RecreationalParkTrailers,ANSI,A119.5-latestedition. InCanadathe range must be installed in accordance with C,AN/CS,A- Z240.6.2 - Electrical Requirementsfor R.V.'s
(CS,AStandard C,AN/CS,A- Z240 RVSeries)and SectionZ240.4.2- Installation
C,AN/CSA- Z240 RVSeries).
ii; I=11
Therangemustbe installedinaccordancewithLocalandNational ElectricCode (NEC)ANSI/NFP,ANo.70-latestedition,or CanadianElectricCodeCSASTB.C221
latestedition.Seerating platefor total connectedKWrating.
ElectricalSupply Connection
The rangerequires120 volts,60 cyclealternatingcurrentfrom a dedicated groundedoutletwitha 15 amp circuit breaker. See serial platefor rating,located on front frame behindstorage drawer.Usermay experienceoccasionalcircuit trippingif Ground FaultCircuit Interrupter (GFCl)outletor breakeris inuse.
MostlocalBuildingRegulationsandCodesrequirethatall electricalwiringbedoneby
licensedelectricians.,Allwiring shouldconformto Local andNational ElectricalCodes. Thisrangerequiresa singlephasethree wire 120/240or a 120/208volt,60 Hz,AC
circuit.Wiringcodes requireaseparatecircuit be runfrom themainentrancepanelto the rangeandthat it beequippedwith separatedisconnectswitch and fuses,eitherin the mainentrancepanelor in a separateswitch and fuse box.
Theelectricalconnectiontothis unitisdesignedonlyforusewith aflexiblepowercord.All
unitsareshippedwith aspeciallydesigned4-wireservicecord.Thiscordshouldbeusedon
allnewbranchcircuits,mobilehomesandwhenlocalcodesprohibitgroundingthrough
theneutral.Fora3-wirecordreplacement,servicekit P/N74011285mustbeused.
In The CommonwealthOf Massachusetts Thisproduct must be installedby a licensed plumberor gasfitter when installed
within the Commonwealth of Massachusetts.A "T" handle type manual gasvalve must be installed in the gas supply line tothis appliance.Aflexible gas connector, when used, must net exceed a length of three (3)feet / 36 inches.
Gas Supply Installationof thisrangemust conform with localcodes or,intheabsenceof
localcodes,with the NationalFuelGasCode,ANSIZ223.1-1atestedition.In
Canadathe rangemustbe installedin accordancewith the current CGA Standard CAN/CGA-B149- Installation Codesfor GasBurningAppliancesand
Equipment and/or local codes.
A QUALIFIEDSERVICEMANORGASAPPLIANCEINSTALLERMUST MAKETHEGASSUPPLYCONNECTION.Leaktestingof theappliance shall be conductedbythe installer accordingto the instructions givenin step6,
Apply a non-corrosive leakdetection fluid to all joints andfittings in the gas connection between the supply line shut-off valve and the range.Include gas
fittings and joints inthe rangeif connections were disturbed during installation. Checkfor leaks! Bubblesappearing around fittings and connectionswill
indicate a leak. Ifa leak appears, turn off supply line gasshut-off valve, tighten connections, turn on the supply line gas shut off valve, and retest for leaks.
CAUTION: NEVER CHECK FOR LEAKS WITH A FLAME. WHEN LEAK CHECK IS COMPLETE, WIPE OFF ALL RESIDUE.
NATURALGASSUPPLYLINEMUSTHAVEA NATURALGASSERVICEREGULATOR. INLETPRESSURETOTHISAPPLIANCESHOULDBEREDUCEDTOA MAXIMUMOF
14 INCHESWATERCOLUMN(0.5 POUNDSPERSQUAREINCH(RS.I.)LIQUEFIED PETROLEUM(L.R)/PROPANEGASSUPPLYLINEMUSTHAVEA L.RGAS
PRESSUREREGULATOR.INLETPRESSURETOTHISAPPLIANCESHOULDBE REDUCEDTOAMAXIMUMOF14 INCHESWATERCOLUMN(0.5 RS.I.).INLET
PRESSURESINEXCESSOF0.5 P.S.I.CANDAMAGETHEAPPLIANCEPRESSURE REGULATORANDOTHERGASCOMPONENTSINTHISAPPLIANCEANDCAN
RESULTINA GASLEAK.
(]as supply pressure for testing regulator must be at least 1" water column pressure above manifold pressure shown on serial plate.
Check Pressure of House Piping System
1.The appliance anditsindividualshutoffvalvemustbe disconnectedfrom the gassupplypipingsystemduringany pressuretestingofthatsystemat test pressuresin excessof 1/2 Ibs./sq. in.(3.5 kPa) (13.8in. watercolumn).
2.The appliance mustbe isolatedfromthe gassupplypipingsystemby
closingitsindividualmanual shutoff valveduringanypressuretestingof
the gassupplypipingsystemat test pressuresequalto or lessthan1/2
Ibs./sq.in. (3.5 kPa)(13.8 in. water column).
AGASSHUT-OFFVALVESHOULDBEPUTIN ANACCESSIBLELOCATIONINTHE
SUPPLYLINEAHEADOFTHERANGE,FORTURNINGONANDTURNINGOFFGAS SUPPLY.Range is to be connectedto house pipingwith flexible metal connectors for gas appliances. CONNECTORNUTSMUSTNOTBECONNECTEDDIRECTLYTO
PIPETHREADS.THECONNECTORSMUSTBE INSTALLEDWITHADAPTORSPROVIDED WITHTHECONNECTOR.
Thehouse piping and/or range connector used to connectthe rangeto the main gas supply must be clean, free ef metal shavings,rust,dirt and liquids(oiler water). Dirt, etc. in the supply lines can work its way into the range manifold and in turn cause failure ofthe gas valves orcontrols and clog burners and/or pilot orifices.
Always use a new flexible connector. Donot use existing flexible connector.
NOTE:Itis recommendedto use a CSAcertified flexible connectornolongerthan36" (91.4cm) with a minimum BTU/HRrating of 60,000.
II [llv vl I[ll .'1=1LvA[llVj=11.'L'I[H=11;[I] =1.'kVJ[HI [€
Followtheseproceduresto removeappliancefor servicing:
1. Slide rangeforward todisengagerangefrom the anti-tipbracket.
2. Shutoff gassupplyto appliance.
3. Disconnectelectricalsupplyto appliance,if equipped.
4. Disconnectgassupplytubingto appliance.
5. Reverseproceduretoreinstall.If gaslinehasbeendisconnected,
checkfor gasleaksafter reconnection.
6.Topreventrangefrom accidentallytipping,rangemust be securedto the floor bysliding rearlevelinglegintotheanti-tipbracket.
NOTE:A qualified servicer should disconnect and reconnect the gas supply. Theservicer MUSTfollow installation instructions provided with the gas appliance connector and the warning label attached to theconnector,
Whenyour range requires service or replacementparts, contact your dealer or authorized service agency. Pleasegivethe complete model and serial number of the range which is located on flip-up plate at the rear of upper left-hand corner or center of backguard.
I Yourrange may not be equippedwith some of the features referred to in this manual. I
THEAPPLIANCE.
Cuisini6reencastrable(zdeux6nergies (zcirculationascendanteJenn-Air
VEUILLEZCONSERVERCE MANUELPOUR CONSULTATIONULTIERIEURE
Ce manuel est pr_vu pour vous aider darts I'installation et les r_glages de la cuisini_re.
Seul du personnel qualifi_ dolt installer ou faire I'entretien de cette cuisini_re.
Lisez les ,, Instructions de s_curit_ ,, darts le guide d'utilisation et d'entretien avant d'utiliser la cuisiniere.
Une installation, des r_glages, des modifications, une utilisation ou un entretien, effectu6s de fa§on inappropri_e, peuvent entrainer de graves blessures ou des d_g&ts mat6riels.
Installateur : Faites attention de ne pas endommager le sol.
ATTENTIO
Nesoulevezpaset nedeplacezpas lacuisiniereenla prenantparlapoigneedela porte,ledessusouledosseret.
QO
Cettecuisinierea etecon(;ueconformementauxexigencesde diversesagencesconcerneesparlasecuriteetrespecteles
temperaturesmaximalespermisesde90°C(194°F)pourles
armoiresen bois.Sicettecuisiniereestinstalleepres
1 1 o
darmoiresnesupportantquunetemperatureinferieurea90 C
o
(194 F),il ya risqueded_coloration,d_laminationoufusion.
Placezlacuisinibredansunendroitbienbclair_.NeI'installez pasau-dessusdetrousdanse pancherou&d'autresendroits
ouellerisqued'etresournise_defortscourantsd'air."route ouverturedansletourderribrelacuisinibreetdanslesolsous
lacuisinibredolt_treferm_eherm_tiquement.Assurez-vous quela circulationdeI'airderefroidissement!ventilationn'est pasentraveesous a cus n_re REMARQUEN'nsta ez PAS
une cuisinibre sur de la moquette de cu sine.
Avis pout altitude _lev6e : Les caract_ristiques nominales
des bn31eurs & gaz pr_cis_essontpr_vuespour des altitudes de 610 rn (2000pieds)max.Ades altitudes plusimportantes, ces valeurs peuventavoir & _tre r_duites pour obtenir un r_sultat satisfaisant. Un r_parateur/installateurcertifi_ pour le gaz sera en mesure de vous indiquersi cela est n_cessaire.
Unrisquequelacuisinibreserenverseexistesi rappareiln'estpasinstallbconform_ment aux instructions d'installation feurnies. Eutilisationcerrecte du dispositif ANTIRENMERSEMENTminimisele risquede RENMERSEMENT.M_me avec cedispositif,
le censemmateur dolt teujours observer les mesures de sbcuritb pr_cis_es darts le
MANUELD'UTILISATIONET D'ENTRETIENet _viter de reentersur les portes des fours.
Lesinstructions d'installation sont fournies pour des endreitsou les murs et lessels sont en boisou en ciment. Toutautre type deconstruction peut n_cessiterdes techniques d'installatien spbciales, pour permettre la fixation du support
ANTIRENVERSEMENTautour ou au sol. Labride dolt _tre install_e afin deretenir le
piedARRIEREGAUCHEou DROIT.REMARQUE: Labride feurnie est cen(;ue pour _tre
utilisbeavecdesprises mouthes ou non en affleurement.Installezla bride en mettant
le treu d'erientation de raile la plus lenguede la bride contre le mur ou le plancher, comme I'illustrent les_tapes 14 _ 19.
MAISONSMOBILES
I'installation d'une cuisini_re con(;uepour une maison mobiledolt _tre conforme _ la
Manufactured HomeConstruction and Safety Standard (norme de s_curit_ et de construction des r_sidencespr_fabriqu_es),titre 24 CFR,pattie 3280 (ant_rieurement,
la FederalStandardfor Mobile HomeConstructionand Safety,titre 24 HUD,pattie280) ou, lersqu'une telle nerme n'est pas applicable, _ lanerme pour les installations de
r_sidencespr_fabriqu_esANSIA225.1/NFPA501A,oucenform_mentauxcodes Iocaux. Au Canada,la cuisini_re dolt _tre install_eselon la nerme courante CSAC22.1- Code canadien de I'_lectricit_, pattie 1 et section Z240.4.1- exigencesd'installatien pour appareils _ gazdes maisons mobiles : (norme CSACAN/CSA- Z240MH).
MAISONSMOBILESPOURPARCRECRE4TIF
I_installationd'une cuisini_re con(;uepourles maisons mobilesde parc r_cr_atif dolt
_.treconferme aux r_glements de I'_tat ou fi d'autres codes, eu en rabsence detels codes,conferme &la norme Standard for RecreationalPark Trailers,(norme pour
maisens mobiles de parc r_cr_atif) ANSIA119.5, _dition laplus r_cente.Au Canada,
la cuisini_re deit _tre install_e selon CAN/CSAZ240.6.2- exigences _lectriques
pourv_hicules r_cr_atifs (nerme CSACAN/CSA- Z240 s_ries VR)et section Z240.4.2- exigencesd'installation pour _quipement et appareilsau propane darts v_hicules r_cr_atifs (nerme CSACAN/CSA- Z240 s_riesVR).
i "| ! _ i i ,I
Lacuisini_redoit _tre install_econform_mentau NationalElectricalCode(NEC) ANSI/NFPAno70- _dition la plusr_cente,ou conformeau Codecauadiende I'_lectricit_,normeCSAC22.1,_ditionlaplusr_cente.Voyezsurlaplaquesignal_tique la puissancenominaletotaleen kW.
RaccordementElectrique
L'alimentation nbcessairedoit _tre un courantalternatifde 120 V,60 Hz provenantd'unepriserbserv_eraise_ laterreet dot_ed'uncoupe-circuitde
15ampbres.Veuillezconsulterla plaquesignal_tique situ_e sur lecadreavant, derribrele tiroir de rangement.Si lecircuitest_quip_ d'un coupe-circuitou d'une prise_ disjoncteurdiffbrentiel,ceux-cipeuventsed_clencherdetemps
autre.
Certainsmodulessont livr_sdirectementde I'usineavecun cordond'alimentation.Aucun raccordementn'est n_cessairesnrcesmodules.II suffit debrancherlecordondanslaprise
murale.Sur les modulessanscordon,le raccordement_.I'alimentationestn_cessaire conform_mentauxcodesIocanx.IIestpossibled'utilisersoitunconduitsoituncordonsouple.
Avecun cordonsouple,pourcnisini_res,neI'utilisezqu'avecdescossesferrulesprevuessoit
pour240volts,40A,soitpour240volts, 50A - ouverturede 34,94mm(1-3/8po)de diam_tre.Uncordon_.4 conducteursdolt _treutilisesnrlesnouvellesinstallations_.circuit
ded_rivation(NEC1996),demaisonsmobiles,de vehiculesr_creatifset I&05lescodes Iocauxinterdisentlaraise&la terreparlene_tre.Unealimentation&3filspeut_treutiliseeI& o_elleestautoris_eparlescodesIocaux.Lorsqu'uncordond'alimentationest utilis_,celui-ci nedoit pasdepasser1,20m(4pieds)enIongueur.