www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
30" Gas Cooktops:
CCGX2420B and CCGX2420W
• Dimensions (Actual Size) •
Overall width:
Overall depth:
Distance from top of counter to bottom of unit:
Cut-Out width:
Cut-Out depth:
29 1/2"
20 9/16"
30 3/16"
21 1/8"
4 5/8"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the RIGHT:
2"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the LEFT:
2"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the REAR:
Minimum spacing to front edge of counter:
1"
2"
Minimum distance between cooktop
and cabinet directly above:
Minimum width of cabinet directly above:
30" min
30"
Maximum depth of cabinets directly
above and adjacent:
13"
Minimum distance between countertop
and adjacent cabinet above:
18"
• Additional Information •
• Distance from top of counter to bottom of gas stub is
3 7/16".
• Electrical requirements : 110/120 volt AC, 60hz. Must
be grounded. 15amp circuit required. Locate outlet
below the cooktop a minimum of 5" below the
countertop if not installing over an under counter oven.
Locate outlet below the oven or in an adjacent cabinet
when installing over an adjacent under counter oven.
• Minimum clearance from top of counter to combustible
material below is 4 7/16"
• Countertop must be supported within 3" of cutout.
• Unit may be installed over a Jenn-Air under counter
oven.
See page 2 for additional information
Side View (not to scale)
20 9/16"
18"
Top view of cutout
(not to scale)
4 5/8"
29 1/2"
30" min
30 3/16"
21 1/8"
Overall Dimensions
Top View (not to scale)
Cut-Out Dimensions
Countertop View
(not to scale)
Cabinet Requirements
Wall View
(not to scale)
30"
Minimum horizontal
clearance between the
edge of the appliance
and combustible
construction extending
from the cooking
surface to 18" above
the cooking surface is
2" (see solid areas)
1 3/4" from right
side of cutout to
centerline of pipe.
Gas inlet location
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
321
Cooktop supplied with 1/2" NPT female inlet on regulator (shipped loose)
BN182.34 • A321B149 • 31469 • 000107 • 104936 • 72451
8 1/2" to centerline of pipe from
front edge of cutout
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• Gas requirements : The Appliance pressure regulator supplied with
this appliance is pre-set and fixed for correct outlet pressure: 5"W.C.
this model is equipped for use with natural gas; 10" W.C. when
converting to LP. The maximum inlet gas supply pressure for the
regulator is 14" W.C. The inlet test pressure for checking the regulator
must be at least 6" W.C if equipped for natural gas; 11" W.C. if
converted to LP gas.
• An individual gas shut-off valve must be used.
• Cabinetry over cooktop : 30' minimum clearance between the top of
the cooking surface and the bottom of an unprotected wood or metal
cabinet. 24" minimum when bottom of wood or metal cabinet is
protected by not less than 1/4" flame retardant millboard covered with
not less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024"
aluminum or copper.
• To eliminate the hazard of reaching over heated surface units,
cabinet storage space located above the surface units should be
avoided. If cabinet storage is to be provided, the hazard can be
reduced by installing a range hood that projects horizontally a
minimum of 5" beyond the bottom of the cabinets.
• Radius corners of cutout and file to insure smooth edges and prevent
corner cracking (1/4" radius).
• CCGX2420B : Black.
• CCGX2420W : White.
Page 2
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
30" Gas Cooktops:
CCGX2420B and CCGX2420W
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or
outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
BN182.34 • A321B149 • 31469 • 000107 • 104936 • 72451
149