Jenn-Air CCGP2820P, CCGP2820PF, CCGP2820PG, CCGP2820PK, CCGP2820PR Dimension Guide

...
www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
Prostyle™ Cooktop:
CCGP2820P, CCGP2820PF, CCGP2820PG,
CCGP2820PK, CCGP2820PR and CCGP2820PU
• Dimensions (Actual Size) •
Overall width:
Overall depth:
46 13/16" 24 9/16"
Minimum distance from top of countertop to
bottom cutout:
6 7/8"
Maximum distance from countertop to
bottom cutout:
9"
Recommended distance from countertop to
bottom cutout:
Cutout width and depth:
8" see pg 3
Min. spacing from cooktop edge to nearest
2"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the LEFT:
6"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the REAR:
15/16"
Minimum distance between cooktop and
cabinet directly above:
Minimum width of cabinet directly above:
30" 48"
Maximum depth of cabinets directly
above and adjacent:
13"
• Additional Information •
• Cabinetry over cooktop : 30' minimum clearance
between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet. 24" minimum when bottom of wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or copper.
• To eliminate the hazard of reaching over heated
surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the hazard can be reduced by installing a range hood that projects horizontally a minimum of 5" beyond the bottom of the cabinets.
• Countertop must be supported within 3" of cutout.
• See page 3 for special cutout instructions. For some
cabinet styles, it may be necessary to reinforce the front of the cabinet by attaching a brace from front to rear inside the cabinet under the burner box.
48"
30"
18"
Prostyle™ Cooktop
2 1/2"
Gas inlet
8 3/8" to center of gas inlet
Cabinet Requirements
Wall View
(not to scale)
Minimum horizontal clearance between the edge of the appliance and combustible construction extending from the cooking surface to 18" above the cooking surface is 2" on the right side and 6" on the left side.
Center of Gas inlet
46 13/16"
6 7/8"
Front View of Cooktop
(not to scale)
See page 2-3 for additional information
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of deter­mining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
231
BN182.34 • A231B149C150 • • 032603 • 95655 • 50217
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• Radius corners of cutout and file to insure smooth edges and prevent
corner cracking (1/4" radius).
• Electric supply for pilotless ignition: 110/120VAC, 60Hz. 15 amp
grounded circuit is required, Power cord is supplied. It is recommended that the outlet is placed a maximum 16" below the burner box.
• Gas requirements : Regulator connection 1/2" N.P.T. (male pipe).
The pressure regulator supplied with this appliance is pre-set and fixed for use with natural gas at 5"W.C. The minimum inlet gas supply pressure for the regulator is 6" W.C. The maximum inlet gas supply pressure for the regulator is 14" W.C. It is recommended that the gas stub is placed at least 16" below the countertop. If LP gas is the fuel of choice, follow the conversion to LP procedure found in the installation instructions.
• An individual gas shut-off valve must be used and located in an
accessible location.
• This appliance is designed to be vented outdoors
• Under counter access must be provided to remove and empty
grease container.
Page 2
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
Prostyle™ Cooktop:
CCGP2820P, CCGP2820PF, CCGP2820PG,
CCGP2820PK, CCGP2820PR and CCGP2820PU
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
BN182.34 • A231B149C150 • • 032603 • 95655 • 50217
149
Loading...
+ 1 hidden pages