JBL IVX-DC808, IVX-DS808, IVX-DS1608, IVX-DC1608 User Manual

Installation Manual
AXYS® Intellivox - DC/DS 808 & 1608 models*
Models Ivx-DC808, Ivx-DS808, Ivx-DC1608, Ivx-DS1608
(Part Nos. 585860, 587860, 585880, 587880)
* For early serial numbers with input board equipped with WAGO connectors.
AXYS® Intellivox 808/1608 Installation Manual Rev 1.1
REFERENCE TO EC STATEMENT OF CONFORMITY
This document confirms that products manufactured by
Duran Audio bearing the CE label meet all the requirements
in the EMC directive 2004/108/EC and LV directive 2006/95/
EC laid down by the Member States Council for adjustment
of legal requirements. Furthermore the products comply
with the rules and regulations from 30 August 1995
referring to the electromagnetic compatibility of devices.
Duran Audio products bearing the CE label comply with the
following harmonised or national standards:
EMC:
EN 55103-1 :1996
EN 55103-2 :1996
Safety:
IEC 60065 :2002
Mains Harmonics:
EN 61000-3-2 :2001
Insulation:
Class1
USER’S NOTICE AND DISCLAIMER:
No part of this manual including the software described in
it may be reproduced, transmitted, transcribed, stored in a
database system or translated without the express written
permission of Duran Audio BV.
Documentation kept by the end user for back-up purposes
is excluded from the above.
All products and corporate names mentioned in this
manual may be registered trademarks or copyrights of their
respective companies. They are used here for indicative
purposes only.
The information contained in this manual has been carefully
checked for accuracy; however no guarantee is given with
respect to its correctness. Duran Audio BV accepts no
responsibility or liability for any errors or inaccuracies that
may appear in this manual or the products and software
described in it.
Specifications and information contained in this manual
are subject to change at any time without notice.
Duran Audio BV
Koxkampseweg 10
5301 KK Zaltbommel
The Netherlands
Tel: +31 418 515583
Fax: +31 418 518077
Zaltbommel, December 2011.
© 1998-2011 Duran Audio BV. All rights reserved.
2
AXYS® Intellivox 808/1608 Installation Manual Rev 1.1
TABLE OF CONTENTS
Reference to Statements of Conformity ...................2
User’s Notice and disclaimer............................2
1. Important Safety Instructions ........................ 4
2. Introduction ...................................... 5
Applicable models and variants.....................5
What’s in the packaging ..........................6
3. Installation Guide.................................. 7
Preparing for Installation..........................7
Signal and Control cables .......................7-8
Mechanical Installation of the Amplifier ..............8
Connector and wiring details ......................9
AC Mains......................................9
WAGO connectors ..............................10
Audio inputs ..................................11
Network connection ............................12
Fault monitoring relay connector...................13
External Ambient SPL/Temperature Sensor . . . . . . . . . . .14
Loudspeaker connections ........................15
Cable Specifications ............................15
Mechanical Installation of the Loudspeaker ..........16
- Acoustic centre ............................16
- Mounting Options..........................17
- Mounting Procedure ........................18
4. System checks ................................... 19
Connecting the PC to the IntelliAmp ................19
Settings file upload ..........................20-21
5. Appendix ....................................... 22
Optional accessories ............................22
Common analogue grounding issues ...............23
Software and firmware updates ...................23
Network cables ................................23
3
1. IMPORTANT SAFETY INSTRUCTIONS
®
Intellivox 808/1608 Installation Manual Rev 1.1
AXYS
This symbol is intended to alert you to the
presence of uninsulated dangerous voltages
within the product’s enclosure that may be
of sufficient magnitude to constitute a risk of
electric shock.
This symbol is used throughout this manual
and is intended to alert you to the presence of
important instructions.
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with dry cloth.
7) Do not block any ventilation openings*. Install in
accordance with the manufacturer’s instructions.
8) Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9) Do not defeat the safety purpose of the polarised or
grounding-type plug*. A grounding-type plug has two
blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10) Protect the power cord from being walked on or
pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus*.
11) Only use attachments/accessories specified by the
manufacturer.
12) Use only with the cart, stand, tripod, bracket
or table specified by the manufacturer, or sold with
the apparatus. When a cart is used, use caution
when moving the cart/apparatus combination to avoid
injury from tip-over.
13) Unplug this apparatus during lightning storms or when
unused for long periods of time*.
14) Refer servicing to qualified service personnel. Servicing
is required when the apparatus has been damaged in any
way, such as power-supply cord or plug is damaged, liquid
has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.
Warning -To reduce the risk of fire or electric
shock, do not expose this apparatus to rain or
moisture and objects filled with liquids, such
as vases, should not be placed on this apparatus.
Warning - To disconnect this apparatus from
the mains power supply, turn off the power at
the switch labelled Circuit Breaker on the front
panel of the amplifier and remove the connector from the
mains input socket labelled Mains on the rear panel*.
®
Warning - the PowerCon
connector should
never be plugged or unplugged when there is
power on the connector, regardless of whether
the amplifier is switched on or not. ALWAYS ensure that
the mains supply is turned off at source before inserting
or removing the PowerCon®*.
Warning - This apparatus is a Class I device and
must be connected to a mains socket outlet that
provides a safety ground connection*.
Warning - The installer should ensure that the
mechanical mounting method employed for
the loudspeaker column should be capable of
supporting four times the weight of the unit (i.e., with
a safety factor of 4x). Always use both the brackets
provided with the unit.
* These safety warnings are applicable to the IntellliAmp amplifier only
4
®
Intellivox 808/1608 Installation Manual Rev 1.1
AXYS
2. INTRODUCTION
This manual describes the recommended installation
procedure for the AXYS® Intellivox DC (DDC2.0) and DS
(DDS) range of loudspeakers, Models DC/DS 808 and 1608.
®
The AXYS
Intellivox is a type of loudspeaker known as
an active DSP-controlled loudspeaker array, which utilises
the principle of mounting multiple, individually-driven
loudspeaker drive units in the vertical plane at specific
spacings. All the Intellivox models covered by this manual
consist of two components: the column loudspeaker unit
and a mains-powered multi-channel power amplifier which
includes a Digital Signal Processing (DSP) section.
The DC/DS 808/1608 models have been specifically
designed for applications where a high SPL is required,
and/or an extended audio frequency response suitable for
high quality music reproduction is desirable.
This manual describes the following aspects of an
installation:
Note that later serial numbers are equipped
with an input board with Phoenix in stead
of WAGO connectors. This manual describes the WAGO
version (early serial numbers). The Phoenix input board is
used from the following serial numbers:
Ivx-DC808 : 011600013
Ivx-DC1608 : 011700010
Ivx-DS808 : 010700016
Ivx-DS1608 : 010800036
The DC/DS808 loudspeaker unit is fitted with six 6.5” lo/
mid-range drivers and two 1” hi-frequency compression
drivers. The DC/DS IntelliAmp supplied with these models
has 8 separate audio channels.
The DC/DS1608 loudspeaker unit is fitted with fourteen
6.5” lo/mid-range drivers and two 1” hi-frequency
compression drivers. The DC/DS IntelliAmp supplied with
these models has 16 separate audio channels.
• Necessarycabling
• Connectorwiring
• Mechanicalinstallation
After installation, the amplifier and
loudspeaker should be tested for basic
functionality using the supplied AXYS
®
WinControl software; the manual also
describes this procedure. (Note that full configuration
and control of the loudspeaker is beyond the scope of this
manual; this topic is fully documented in the WinControl
Help files.)
APPLICABLE MODELS, AND VARIANTS
This manual applies to the following AXYS® Intellivox
models*:
Intellivox-DC808 and DC1608
Intellivox-DS808 and DS1608
The DS models use a different DSP algorithm from the DC
models. This difference may be ignored for the purposes of
installation and commissioning.
DC/DS 1608 DC/DS 808
fig.1 The Intellivox models covered by this manual
* Other members of the Intellivox range, including DC/DS 115 and DC/DS/DSX 180, 280, 430 and 500 models have different
installation procedures and this manual should NOT be used when installing them. Refer instead to Intellivox Installation Manual Ref. 2008 10/IvxIM_v2.0.
5
AXYS® Intellivox 808/1608 Installation Manual Rev 1.1
WHAT’S IN THE PACKAGING
The Intellivox is shipped in two separate shipping cartons: the loudspeaker unit and the amplifier/DSP section.
Loudspeaker:
In addition to the loudspeaker itself, each unit is shipped with the following items:
• Twomountingbrackets,pre-attached*totheloudspeaker
• Boxcontainingspeakercable(5m),ttedwith20-way(DC/DS808)or40-way(DC/DS1608)Hartingconnectorsateach
end (male-to-female)
Amplifier:
In addition to the IntelliAmp itself, each unit is shipped with the following items:
• Installationmanual(thisdocument)
• Datasheetspecictothemodel
®
• ACpowercable(2m),ttedwithaNeutrik
• Packageofsmallparts,consistingof:
PowerCon® connector and a European mains plug
REF ITEM QTY USE
A M8 x 45 mm hex-head screws with washers and wall plugs 8 Mounting bracket fixings* (wall)
B 5-pole female WAGO connector, with cover 1
C 5-pin XLR male connector 1
D 6-pole female WAGO connector, with cover 1
Mating connector for rear panel
RS-485 control port
Connector for front panel
RS-485 interface
Mating connector for rear
panel audio inputs
E, F Set of PVC inserts for WAGO connectors, with wire insertion tool 1 WAGO connector wiring
A B C
D
fig.2 - Box contents
E F
* The mounting brackets are fitted to the loudspeaker at the factory in order to provide protection during shipment of the
HF compression drivers.
6
AXYS® Intellivox 808/1608 Installation Manual Rev 1.1
Ambient noise
3. INSTALLATION GUIDE
PREPARING FOR INSTALLATION
Before starting to install the Intellivox loudspeaker, a
number of points should be considered.
• It is assumed that the installation site has been the
subject of an extensive DDA investigation or optimisation
prior to the actual install. (DDA = Digital Directivity Analysis,
®
the AXYS
for these products*). This procedure will have identified the
optimum physical location for the Intellivox loudspeaker,
to accurately achieve the desired acoustic coverage. In
particular, the “acoustic centre” position will have been
specified, in terms of height above the finished floor. The
installer should confirm that he/she has this information.
• Unlessspeciedotherwisebythesoundsystemdesigner,
the Intellivox column should be installed at a position exactly
perpendicular to the listening plane (i.e. vertical if the floor is
horizontal). Unlike conventional loudspeaker systems, minor
mechanical misalignment may lead to degraded coverage
and intelligibility. Ensure (by use of a levelling device such
as a spirit level) that the surfaces to which the mounting
brackets will be attached are absolutely vertical and in
the same plane, and that all the individual fixing holes are
themselves in the same plane.
• The only electrical connection to be made to the
Intellivox loudspeaker is the multicore cable from the
amplifier. Consideration should be given to its cable route
and also to ease of rear access to the connector. The Harting
connector is quite large and allowance for its size needs to
be made when preparing the mounting location.
• TheseparateIntelliAmpisintendedtobemountedina
standard 19” rack; this should be as near as practical to the
loudspeaker column. The standard speaker cable supplied is
5 m in length, but longer versions, up to 25 m, are available
to special order; please contact JBL for more information.
The amplifier operates from 230 V as well as 115 V AC
mains; a suitable AC mains outlet will be required at the rack
location. The outlet must be on a circuit able to supply the
proprietary simulation and optimisation software
full-load current and the maximum short-term in-rush current
drawn by the amplifier. Refer to the datasheet supplied for
the actual figures specific to the model being installed. The
third terminal of the mains outlet must be connected to a
proper safety ground. Local safety regulations may require
a separate mains distribution network or an uninterruptible
mains power supply (UPS).
SIGNAL AND CONTROL CABLES
REQUIRED CONNECTIONS
Audio
External
+ Temperature
sensor
OPTIONAL CONNECTIONS
fig.3 - Connections
RS-485
Amplifier
• Inadditiontothemainssupplyandthemulticorecable
to the loudspeaker, some or all of the following cables will
need to be run to the rack location. The necessity for each
of these will have been determined by the system designer;
the installer should ensure that he/she has these details to
hand. All wiring details can be found on pages 9-15.
• Networkconnection:the IntelliAmpiscongured,and
may also be monitored, from a PC running AXYS
software. With all installations it will be necessary to upload
the correct settings for each unit (loudspeaker/amplifier
combination) to obtain the desired acoustic coverage. Once
this has been done, there is strictly no longer an operational
need to have the IntelliAmp connected to a PC because all
AC Mains
supply
Failure Relay
via
Harting
connector
®
WinControl
* Authorised electro-acoustic consultants or ‘build & design’ sound contractors can apply for a DDA License free of charge.
This license can be obtained through our website at http://www.duran-audio.com/ For further information please refer to the Help files and manual with the DDA software.
7
®
Intellivox 808/1608 Installation Manual Rev 1.1
AXYS
settings are stored locally within the unit’s memory and in
the event of a power failure will be automatically reloaded
on power-up. The system designer will have determined
whether a permanent network connection needs to be
provided. This will be the case if the Intellivox is to be
monitored remotely during normal operation. Otherwise,
the network wiring can be omitted, but consideration should
still be given to the amplifier’s location with regard to ease
of both initial and future access for a PC connection. It may
be appropriate to install network wiring in order to provide
a network access point at a location more easily accessible
than at the rack. A cable with two individually foil-screened
twisted pairs should be used. Details of suitable cables can
be found at page 23.
• Audioinputs:the IntelliAmpacceptslinelevelaudio(0
dBV)*. Two separate transformer-balanced audio inputs
are provided; however, units are shipped with only input 1
active. Input 2 can be made active via WinControl.
• Fault monitoring: if network monitoring is not to be
used, a simple surveillance function may be realised by
means of the IntelliAmp’s ‘failure detect’ volt-free relay. This
connection requires a 2-core cable.
• AmbientNoiseSensing:theDSPsectionoftheIntelliAmp
incorporates an autogain algorithm which can adjust the
gain of the system in response to changing ambient noise
levels. If this feature is to be used, an external ambient
microphone (available as an option**) should be connected
if specified by the system designer. Standard screened two-
core microphone cable should be used for this purpose.
• Frostprotection:TheIntelliAmpisequippedwithafrost
protection system which activates an internally generated
pilot tone if the ambient temperature drops below a pre-
determined threshold. The frost protection threshold can be
set using WinControl. If this function is required, an external
ambient temperature sensor (available as an option**)
should be connected with screened two-core cable (or
similar) for its correct operation.
MECHANICAL INSTALLATION OF THE AMPLIFIER
The IntelliAmp is designed to be mounted in a standard 19”
equipment rack. The front panel is fitted with rackmount ears
for this purpose. The IntelliAmp occupies 3U of vertical rack
space.
Note that due to the weight of the amplifier,
the use of additional rear supports is strongly
recommended. The rear of the unit has additional
mounting points to facilitate this.
Ventilation
The IntelliAmp is forced-air cooled by two internal
temperature-controlled fans. This ventilation method should
ensure that the amplifier remains within its operational
temperature range under most circumstances, but if it is to
be installed in a location of high ambient temperature, and/
or in a rack containing a significant quantity of other heat-
generating equipment (see below), consideration should be
given to climate-controlling the room in which the equipment
rack is situated.
Do not install the IntelliAmp in a 19” rack
immediately above or below another item of
equipment generating a significant amount of
heat (e.g. another power amplifier). Plain 1U blank panels
should be used as spacers. Note that slotted or perforated
ventilation panels should not be used, as these will reduce
the effect of forced-air cooling. Also, be aware of the rear-
to-front direction of airflow of the IntelliAmp ; it is not good
practice to install equipment employing forced-air cooling
with different directions of airflow in the same enclosed rack.
Airflow is via the grilles at the rear (intake) and
front (exhaust) of the amplifier. Ensure that
both sets of grilles are completely clear of any
obstructions within 100 mm (4”) in order to maintain the
necessary airflow.
See page 16 for details regarding the mechanical installation
of the loudspeaker enclosure.
* The IntelliAmp may be ordered with alternative input modules which accept signals directly from 70/100 V distribution
systems. Two modules are available: a) with one normal 0 dBV balanced line level input and one 70/100 V input, b) with two 70/100 V inputs. These options need to be specified at the time of ordering. See page 22 for order codes.
** Note that the optional external ANS microphone is combined with a temperature sensor in a single unit (JBL Order Code
97661101). If both functions are required, the use of 2-pair screened cable is recommended.
8
Loading...
+ 16 hidden pages