JBL IVX-DC808, IVX-DS808, IVX-DS1608, IVX-DC1608 User Manual

0 (0)
JBL IVX-DC808, IVX-DS808, IVX-DS1608, IVX-DC1608 User Manual

Installation Manual

AXYS® Intellivox - DC/DS 808 & 1608 models*

Models Ivx-DC808, Ivx-DS808, Ivx-DC1608, Ivx-DS1608

(Part Nos. 585860, 587860, 585880, 587880)

* For early serial numbers with input board equipped with WAGO connectors.

AXYS® Intellivox 808/1608 Installation Manual Rev 1.1

REFERENCE TO EC STATEMENT OF CONFORMITY

This document confirms that products manufactured by Duran Audio bearing the CE label meet all the requirements in the EMC directive 2004/108/EC and LV directive 2006/95/ EC laid down by the Member States Council for adjustment of legal requirements. Furthermore the products comply with the rules and regulations from 30 August 1995 referring to the electromagnetic compatibility of devices. Duran Audio products bearing the CE label comply with the following harmonised or national standards:

EMC:

EN 55103-1 :1996

EN 55103-2 :1996

Safety:

IEC 60065 :2002

Mains Harmonics:

EN 61000-3-2 :2001

Insulation:

Class1

Duran Audio BV

Koxkampseweg 10

5301 KK Zaltbommel

The Netherlands

Tel: +31 418 515583

Fax: +31 418 518077

Zaltbommel, December 2011.

User’s Notice and disclaimer:

No part of this manual including the software described in it may be reproduced, transmitted, transcribed, stored in a database system or translated without the express written permission of Duran Audio BV.

Documentation kept by the end user for back-up purposes is excluded from the above.

All products and corporate names mentioned in this manual may be registered trademarks or copyrights of their respective companies. They are used here for indicative purposes only.

The information contained in this manual has been carefully checked for accuracy; however no guarantee is given with respect to its correctness. Duran Audio BV accepts no responsibility or liability for any errors or inaccuracies that may appear in this manual or the products and software described in it.

Specifications and information contained in this manual are subject to change at any time without notice.

© 1998-2011 Duran Audio BV. All rights reserved.

201112/IvxHPIM_v1.1

2

AXYS® Intellivox 808/1608 Installation Manual Rev 1.1

TABLE OF CONTENTS

Reference to Statements of Conformity . . . . .

. . .

.

.2

User’s Notice and disclaimer . . . . . . . . .

. . .

.

.2

1. Important Safety Instructions . . . . . . . .

. . .

.

4

2. Introduction . . . . . . . . . . . . . . .

. . .

.

5

Applicable models and variants . . . . . .

. . . . 5

What’s in the packaging . . . . . . . . .

. . . . 6

3. Installation Guide . . . . . . . . . . . . .

. .

.

. 7

Preparing for Installation . . . . . . . .

. . .

.

.7

Signal and Control cables . . . . . . . .

. . .

. 7-8

Mechanical Installation of the Amplifier . . .

. . . . 8

Connector and wiring details . . . . . . .

. . . . 9

AC Mains . . . . . . . . . . . . . .

. . .

.

.9

WAGO connectors . . . . . . . . . . . . . . .10

Audio inputs . . . . . . . . . . . . .

. . .

.

11

Network connection . . . . . . . . . .

. . .

.

12

Fault monitoring relay connector . . . . .

. . .

.

13

External Ambient SPL/Temperature Sensor . . .

. . . . .

. . .14

Loudspeaker connections . . . . . . . .

. . .

.

15

Cable Specifications . . . . . . . . . .

. . .

.

15

Mechanical Installation of the Loudspeaker .

. . .

.

16

- Acoustic centre . . . . . . . . . .

. . . .16

- Mounting Options . . . . . . . . .

. . . .17

- Mounting Procedure . . . . . . . .

. . . .18

4. System checks . . . . . . . . . . . . . .

. . .

.

19

Connecting the PC to the IntelliAmp . . . . . . . .19

Settings file upload . . . . . . . . . . . . . 20-21

5. Appendix . . . . . . . . . . . . . . . . . . . . 22

Optional accessories . . . . . . . . . . . . . . 22

Common analogue grounding issues . . . . . . . .23

Software and firmware updates . . . . . . . . . .23

Network cables . . . . . . . . . . . . . . . . 23

201112/IvxHPIM_v1.1

3

AXYS® Intellivox 808/1608 Installation Manual Rev 1.1

1. IMPORTANT SAFETY INSTRUCTIONS

This symbol is intended to alert you to the presence of uninsulated dangerous voltages within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock.

This symbol is used throughout this manual and is intended to alert you to the presence of important instructions.

1)Read these instructions.

2)Keep these instructions.

3)Heed all warnings.

4)Follow all instructions.

5)Do not use this apparatus near water.

6)Clean only with dry cloth.

7)Do not block any ventilation openings*. Install in accordance with the manufacturer’s instructions.

8)Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9)Do not defeat the safety purpose of the polarised or grounding-type plug*. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10)Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus*.

11)Only use attachments/accessories specified by the manufacturer.

12)Use only with the cart, stand, tripod, bracket or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution

when moving the cart/apparatus combination to avoid injury from tip-over.

13)Unplug this apparatus during lightning storms or when unused for long periods of time*.

14)Refer servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

Warning -To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such

as vases, should not be placed on this apparatus.

Warning - To disconnect this apparatus from the mains power supply, turn off the power at the switch labelled Circuit Breaker on the front

panel of the amplifier and remove the connector from the mains input socket labelled Mains on the rear panel*.

Warning - the PowerCon® connector should never be plugged or unplugged when there is power on the connector, regardless of whether

the amplifier is switched on or not. ALWAYS ensure that the mains supply is turned off at source before inserting or removing the PowerCon®*.

Warning - This apparatus is a Class I device and must be connected to a mains socket outlet that provides a safety ground connection*.

Warning - The installer should ensure that the mechanical mounting method employed for the loudspeaker column should be capable of supporting four times the weight of the unit (i.e., with a safety factor of 4x). Always use both the brackets

provided with the unit.

* These safety warnings are applicable to the IntellliAmp amplifier only

201112/IvxHPIM_v1.1

4

AXYS® Intellivox 808/1608 Installation Manual Rev 1.1

2. INTRODUCTION

This manual describes the recommended installation procedure for the AXYS® Intellivox DC (DDC2.0) and DS (DDS) range of loudspeakers, Models DC/DS 808 and 1608.

The AXYS® Intellivox is a type of loudspeaker known as an active DSP-controlled loudspeaker array, which utilises the principle of mounting multiple, individually-driven loudspeaker drive units in the vertical plane at specific spacings. All the Intellivox models covered by this manual consist of two components: the column loudspeaker unit and a mains-powered multi-channel power amplifier which includes a Digital Signal Processing (DSP) section.

The DC/DS 808/1608 models have been specifically designed for applications where a high SPL is required, and/or an extended audio frequency response suitable for high quality music reproduction is desirable.

This manual describes the following aspects of an installation:

Necessary cabling

Connector wiring

Mechanical installation

After installation, the amplifier and loudspeaker should be tested for basic functionality using the supplied AXYS® WinControl software; the manual also

describes this procedure. (Note that full configuration and control of the loudspeaker is beyond the scope of this manual; this topic is fully documented in the WinControl Help files.)

APPLICABLE MODELS, AND VARIANTS

This manual applies to the following AXYS® Intellivox models*:

Intellivox-DC808 and DC1608

Intellivox-DS808 and DS1608

Note that later serial numbers are equipped with an input board with Phoenix in stead of WAGO connectors. This manual describes the WAGO

version (early serial numbers). The Phoenix input board is used from the following serial numbers:

Ivx-DC808 : 011600013

Ivx-DC1608 : 011700010

Ivx-DS808 : 010700016

Ivx-DS1608 : 010800036

The DC/DS808 loudspeaker unit is fitted with six 6.5” lo/ mid-range drivers and two 1” hi-frequency compression drivers. The DC/DS IntelliAmp supplied with these models has 8 separate audio channels.

The DC/DS1608 loudspeaker unit is fitted with fourteen 6.5” lo/mid-range drivers and two 1” hi-frequency compression drivers. The DC/DS IntelliAmp supplied with these models has 16 separate audio channels.

The DS models use a different DSP algorithm from the DC models. This difference may be ignored for the purposes of installation and commissioning.

DC/DS 1608 DC/DS 808

fig.1 The Intellivox models covered by this manual

*Other members of the Intellivox range, including DC/DS 115 and DC/DS/DSX 180, 280, 430 and 500 models have different installation procedures and this manual should NOT be used when installing them. Refer instead to Intellivox Installation Manual Ref. 2008 10/IvxIM_v2.0.

201112/IvxHPIM_v1.1

5

AXYS® Intellivox 808/1608 Installation Manual Rev 1.1

WHAT’S IN THE PACKAGING

The Intellivox is shipped in two separate shipping cartons: the loudspeaker unit and the amplifier/DSP section.

Loudspeaker:

In addition to the loudspeaker itself, each unit is shipped with the following items:

Two mounting brackets, pre-attached* to the loudspeaker

Box containing speaker cable (5 m), fitted with 20-way (DC/DS808) or 40-way (DC/DS1608) Harting connectors at each end (male-to-female)

Amplifier:

In addition to the IntelliAmp itself, each unit is shipped with the following items:

Installation manual (this document)

Datasheet specific to the model

AC power cable (2 m), fitted with a Neutrik® PowerCon® connector and a European mains plug

Package of small parts, consisting of:

REF

ITEM

QTY

USE

 

 

 

 

A

M8 x 45 mm hex-head screws with washers and wall plugs

8

Mounting bracket fixings* (wall)

 

 

 

 

B

5-pole female WAGO connector, with cover

1

Mating connector for rear panel

RS-485 control port

 

 

 

 

 

 

 

C

5-pin XLR male connector

1

Connector for front panel

RS-485 interface

 

 

 

 

 

 

 

D

6-pole female WAGO connector, with cover

1

Mating connector for rear

panel audio inputs

 

 

 

 

 

 

 

E, F

Set of PVC inserts for WAGO connectors, with wire insertion tool

1

WAGO connector wiring

 

 

 

 

A

 

B

 

C

 

D

 

 

 

 

 

 

 

fig.2 - Box contents

E

F

*The mounting brackets are fitted to the loudspeaker at the factory in order to provide protection during shipment of the HF compression drivers.

201112/IvxHPIM_v1.1

6

AXYS® Intellivox 808/1608 Installation Manual Rev 1.1

3. INSTALLATION GUIDE

PREPARING FOR INSTALLATION

Before starting to install the Intellivox loudspeaker, a number of points should be considered.

It is assumed that the installation site has been the subject of an extensive DDA investigation or optimisation prior to the actual install. (DDA = Digital Directivity Analysis, the AXYS® proprietary simulation and optimisation software for these products*). This procedure will have identified the optimum physical location for the Intellivox loudspeaker, to accurately achieve the desired acoustic coverage. In particular, the “acoustic centre” position will have been specified, in terms of height above the finished floor. The installer should confirm that he/she has this information.

Unlessspecified otherwisebythesoundsystemdesigner, the Intellivox column should be installed at a position exactly perpendicular to the listening plane (i.e. vertical if the floor is horizontal). Unlike conventional loudspeaker systems, minor mechanical misalignment may lead to degraded coverage and intelligibility. Ensure (by use of a levelling device such as a spirit level) that the surfaces to which the mounting brackets will be attached are absolutely vertical and in the same plane, and that all the individual fixing holes are themselves in the same plane.

The only electrical connection to be made to the

Intellivox loudspeaker is the multicore cable from the amplifier. Consideration should be given to its cable route and also to ease of rear access to the connector. The Harting connector is quite large and allowance for its size needs to be made when preparing the mounting location.

The separate IntelliAmp is intended to be mounted in a standard 19” rack; this should be as near as practical to the loudspeaker column. The standard speaker cable supplied is 5 m in length, but longer versions, up to 25 m, are available to special order; please contact JBL for more information. The amplifier operates from 230 V as well as 115 V AC mains; a suitable AC mains outlet will be required at the rack location. The outlet must be on a circuit able to supply the

full-load current and the maximum short-term in-rush current drawn by the amplifier. Refer to the datasheet supplied for the actual figures specific to the model being installed. The third terminal of the mains outlet must be connected to a proper safety ground. Local safety regulations may require a separate mains distribution network or an uninterruptible mains power supply (UPS).

SIGNAL AND CONTROL CABLES

REQUIRED CONNECTIONS

Audio

RS-485

AC Mains

supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

via Harting connector

Amplifier

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External

Failure Relay

Ambient noise

 

+ Temperature

 

sensor

 

OPTIONAL CONNECTIONS

fig.3 - Connections

In addition to the mains supply and the multicore cable to the loudspeaker, some or all of the following cables will need to be run to the rack location. The necessity for each of these will have been determined by the system designer; the installer should ensure that he/she has these details to hand. All wiring details can be found on pages 9-15.

Network connection: the IntelliAmp is configured, and may also be monitored, from a PC running AXYS® WinControl software. With all installations it will be necessary to upload the correct settings for each unit (loudspeaker/amplifier combination) to obtain the desired acoustic coverage. Once this has been done, there is strictly no longer an operational need to have the IntelliAmp connected to a PC because all

*Authorised electro-acoustic consultants or ‘build & design’ sound contractors can apply for a DDA License free of charge. This license can be obtained through our website at http://www.duran-audio.com/

For further information please refer to the Help files and manual with the DDA software.

201112/IvxHPIM_v1.1

7

AXYS® Intellivox 808/1608 Installation Manual Rev 1.1

settings are stored locally within the unit’s memory and in the event of a power failure will be automatically reloaded on power-up. The system designer will have determined whether a permanent network connection needs to be provided. This will be the case if the Intellivox is to be monitored remotely during normal operation. Otherwise, the network wiring can be omitted, but consideration should still be given to the amplifier’s location with regard to ease of both initial and future access for a PC connection. It may be appropriate to install network wiring in order to provide a network access point at a location more easily accessible than at the rack. A cable with two individually foil-screened twisted pairs should be used. Details of suitable cables can be found at page 23.

Audio inputs: the IntelliAmp accepts line level audio (0 dBV)*. Two separate transformer-balanced audio inputs are provided; however, units are shipped with only input 1 active. Input 2 can be made active via WinControl.

Fault monitoring: if network monitoring is not to be used, a simple surveillance function may be realised by means of the IntelliAmp’s ‘failure detect’ volt-free relay. This connection requires a 2-core cable.

Ambient Noise Sensing: the DSP section of the IntelliAmp incorporates an autogain algorithm which can adjust the gain of the system in response to changing ambient noise levels. If this feature is to be used, an external ambient microphone (available as an option**) should be connected if specified by the system designer. Standard screened twocore microphone cable should be used for this purpose.

Frost protection: The IntelliAmp is equipped with a frost protection system which activates an internally generated pilot tone if the ambient temperature drops below a predetermined threshold. The frost protection threshold can be set using WinControl. If this function is required, an external ambient temperature sensor (available as an option**) should be connected with screened two-core cable (or similar) for its correct operation.

MECHANICAL INSTALLATION OF THE AMPLIFIER

The IntelliAmp is designed to be mounted in a standard 19” equipment rack. The front panel is fitted with rackmount ears for this purpose. The IntelliAmp occupies 3U of vertical rack space.

Note that due to the weight of the amplifier, the use of additional rear supports is strongly recommended. The rear of the unit has additional

mounting points to facilitate this.

Ventilation

The IntelliAmp is forced-air cooled by two internal temperature-controlled fans. This ventilation method should ensure that the amplifier remains within its operational temperature range under most circumstances, but if it is to be installed in a location of high ambient temperature, and/ or in a rack containing a significant quantity of other heatgenerating equipment (see below), consideration should be given to climate-controlling the room in which the equipment rack is situated.

Do not install the IntelliAmp in a 19” rack immediately above or below another item of equipment generating a significant amount of heat (e.g. another power amplifier). Plain 1U blank panels

should be used as spacers. Note that slotted or perforated ventilation panels should not be used, as these will reduce the effect of forced-air cooling. Also, be aware of the rear- to-front direction of airflow of the IntelliAmp ; it is not good practice to install equipment employing forced-air cooling with different directions of airflow in the same enclosed rack.

Airflow is via the grilles at the rear (intake) and front (exhaust) of the amplifier. Ensure that both sets of grilles are completely clear of any obstructions within 100 mm (4”) in order to maintain the

necessary airflow.

See page 16 for details regarding the mechanical installation of the loudspeaker enclosure.

*The IntelliAmp may be ordered with alternative input modules which accept signals directly from 70/100 V distribution systems. Two modules are available: a) with one normal 0 dBV balanced line level input and one 70/100 V input, b) with two 70/100 V inputs. These options need to be specified at the time of ordering. See page 22 for order codes.

**Note that the optional external ANS microphone is combined with a temperature sensor in a single unit (JBL Order Code 97661101). If both functions are required, the use of 2-pair screened cable is recommended.

201112/IvxHPIM_v1.1