Jackson HH-GPX User Manual

Page 1
TempStar™ HH/GPX
Models
Te mpSt ar™ HH/G PX
Standard Features
Multi-cycle timer (Extra Heavy,
Heavy, Medium, Normal) Built-in pressure regulator and
gauge Extended 15 second high tempera-
ture rinse provides superior cover­age and rapid drying 20 3/4” (527 mm) wide X 27” (686
mm) high opening accommodates 18” (457 mm) X 26” (660 mm) sheet pans and 60 quart mixing bowls Auto-fill / auto-start
Safety door switch
External gas booster heater
- Capable of minimum 70˚F (21˚C) degree temperature rise
- Recirculates water through stain­less steel coils in wash tank to main­tain 150˚F (66˚C) degree minimum temperature Hi-limit thermostat and low water
protection Top mounted controls for ease of
installation Unique lower counter-rotating
wash arms and upper wash arm provide optimum spray coverage and superior cleaning action Unique split-door design for installa-
tions with low ceiling heights Large scrap tray
Self-draining stainless steel pump
Detergent/rinse additive signal
connection fuse box
Project
Item
Quantity
CSI Sec tion 11400
Date
Delime/manual wash switch
Adjustable bullet feet
Uses standard 20” X 20”
(508 mm X 508 mm) racks Front dress panel
Mandator y Specs
Specify incoming water
temperature
Specify how far booster
will be placed from unit
Specify altitude for
proper booster size
Optional Features
Water hammer arrestor Flanged feet Drain quench system Scaltrol
Accessories
36” (914 mm) compartment
rack 4 1/6” (4 mm) tall
36” (914 mm) compartment
rack 5 5/8” (16 mm) tall
36” (914 mm) compartment
rack 7” (178 mm) tall
Combination rack Peg rack
Sheet pan rack 18” X 26” / (457 mm X 660 mm) baking pans
Specifications
U s e s 1 . 3 6 g a l l o n s ( 5 l i t e r s ) o f 1 8 0 ˚F
(82˚C) w a t e r p e r r a c k
T ot a l a u t o m a t i c n o r m a l c y c l e - 6 2 s e c o n d s
5 3 r a c k s p er h o u r n o r m a l c y c l e
2 H P Wa s h P u m p M o t o r
Highway 25E
P. O. Box 1060
Barbourville, KY 40906
Tel: 606-523-9795
Tel: 1-888-800-5672
Fax: 606-523-9196
E-mail: info@jacksonmsc.com
S i n g l e Po i n t c o n n e c t i o n s f o r a l l u t i l i t i e s
B u i l t - i n w a t e r p r e s s u r e r e g u l a t o r a n d p r e s s u re g a u g e
F i e l d c o n v e r t i b l e f r o m s t r a i g h t t h r o u g h t o c o r n e r o p e r a t i o n s
H e a v y d u t y s t a i n l e s s s t e e l c o n s t r u c t i o n
www.jacksonmsc.com
07610-002-66-62 (09/07)
Page 2
WATER REQUIREMENTS
Inlet Tempterature
40˚F / (4˚ C) Rise 140˚ F / (82˚C)
70˚F / (21 ˚C) Rise 110˚F / (60˚ C)
Gallons per hour 72.1 / 2 73 Ltr.
Waterline Size IPS (Minimum-inches) 3/4
Drainline Size IPS (Minimum-Inches) 1-1/2
Flow Pressure (PSI) 15-25
Tank Capacity
Wash Tank 8 Gal . / (30 ltr )
Booster Tank 3 Gal . / (11 ltr )
Pump Capacity (GPM) 73 Ga l / (276 lt r)
4 [102mm]
4 [102mm]
34 [861mm]
25 [637mm]
86
3 4
[2202mm]
17 [432mm]
C
73 [1856mm]
27 [687mm]
10
3 4
[274mm]
11
3 4
[298mm]
A
3
1 2
[92mm]
E
1 [25mm]
7
3 4
[194mm]
LEGEND A - DRAIN 1 1/2” NPT B - WATER INLET 1/2” NPT C - ELECTRICAL CONNECTION D - OUTLET TO BOOSTER HEATER 3/4” NPT E - INLET FROM BOOSTER HEATER 3/4” NPT
All vertical dimensions are +/- 1/2" due to adjustable bullet feet.
34 [866mm]
A
25
1 4
[639mm]
3 [79mm]
C
15
1 4
[387mm]
11
3 4
[298mm]
B
D
E
18 [456mm]
16
3 4
[426mm]
5 [126mm]
25
1 4
[642mm]
32 [813mm]
3 [77mm]
C
DIMENSIONS--STANDARD MODEL
MODEL NO.
HE IGH T WI DTH DE PTH WE IGH T CL ASS CU BE HEI GHT WI DTH D EPT H
SI ZE
DR AIN
HE IGH T
SH IPP ING IN FO DI MEN SIO NS
Temp Star™ H H/GPX
76-3/ 4”
(1949 mm)
25-1/ 4”
(641 mm)
DIMENSION REQUIREMENTS
Minimum Ceiling Height (Recommended)
Wall Clearance (Minimum) 4” / (1 02 m m)
Standard Table Height 34” / ( 864 mm)
Inside Clearance 17-1/ 4”/ (43 8 m m)
OPERATING CAPACITY
Racks per Hour
OPERATING CYCLE (sec)
Normal 45 15 2 62
Medium 103 15 2 120
Heavy 1 63 15 2 180
Extra Heavy 283 15 2 300
OPERATING TEMPERATURES
Wash (Minimum) 150˚F / (66 ˚C)
Rinse (Minimum) 180˚F / (82˚ C)
WASH PUMP MOTOR
Wash Pump Motor Horsepower 2 HP
How To Specify - TempStar™ HH/GPX
Highway 25E
P. O. Box 1060
Barbourville, KY 40906
We reserve the right to change specications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.
Norma l53Mediu m28Heavy19Extra Heavy
Was h Rin se
Tel: 606-523-9795
Tel: 1-888-800-5672
Fax: 606-523-9196
E-mail: info@jacksonmsc.com
25-1/ 4”
(641 mm)
11-3/ 4”
(298 mm)
88” / ( 2 me ters)
11
Dwell Tota l Cyc le
420 l bs
(191 kg)
92.5 71.4 cu. ft.
85”
(2159 mm)
44”
(1118 mm)
33”
(838 mm)
GAS REQUIREMENTS
Maximum M inim um
Natural Gas (Inches-water column) 10.5 / (267 mm) 5.0 / (1 27 mm)
LP Propane Gas (Inches-water column) 13.0 / (33 0 mm ) 11.0 / 292 mm)
Gas Booster Capacity (BTU)
Input 105,0 00
Output 84,80 0
APPROXIMATE TOTAL LOAD AMPS
AMPS
115V/60HZ/1PH
208V/60HZ/1PH
230V/60HZ/3PH 13
230V/60HZ/1PH 13
230V/60HZ/3PH 13
www.jacksonmsc.com
07610-002-66-62 (09/07)
25
13
Loading...