
SAFETY RULES
To avoid personal or environmental damages and to guarantee a proper
operation of the equipment, the staff in charge of the installation, set up and
maintenance of the equipment must follow the instructions of this manual,
specially recommendations and warnings explicitly detailed. In additon, specific
instructions for the chemical products to be dosed should be followed.
INDEX
1.- GENERAL DESCRIPTION 4
2.- SHIPMENT 4
3.- TECHNICAL FEATURES 5
4.- OPERATION 6
5.- INSTALLATION 7
Generalities 7
Hydraulic connection 7
Electric conection
8
6.- START UP 10
DOSITEC - MP 11
DOSITEC - MD 12
DOSITEC - mA 13
DOSITEC - Q 16
DOSITEC - PRC
7.- MAINTENANCE
List of parts
34
C.E. APPROVAL DECLARATION 39
WARRANTY 39
36

4
1.- GENERAL DESCRIPTION
The dosing pumps DOSITEC are heavy duty, high precission, electric
diaphragm pumps for dosing liquid products.
DOSITEC models:
DOSITEC -MP: Manual Regulation from 0 to100% by potentiometer
DOSITEC -MD: Manual Regulation from 0 to100% by keyboard
DOSITEC - Q: Proportional regulation
DOSITEC - mA: Analogic regulation by a current signal
DOSITEC - PRC: Control PH or ORP(Redox)
DOSITEC - MF: Multifuntion (Manual flow regulation / proportinonal / Analogical
4-20mA / with timer)
DOSITEC dosing pumps are manufactured with materials that can resist most
chemicals products, even acids. They are designed for all sorts of processes
where it is necessary to dose a product into a hydraulic network, such as: food,
textile, chemical industry, water treatments, etc. (See materials in Technical
Features). In case there is any doubt about compatibility of materials with the
products to be used please contact ITC S.L. Technical Service.
The metering pump has been designed to feed liquids with capacities from 0 to
15 l/h and pressures from 0 to 10 bar. They also include a conexion for a level
switch..
2.- SHIPMENT
The original packaging is prepared to transport and storage the goods, if it is
done in dry, aired spaces and far from sources of heat, always keeping the
pump in vertical position.
Inside the pack it is included:
Dosing pump.
Semirigid PE hose, white, lenght 2m.
Flexible PVC hose transparent crystal type, lenght 2m.
Injection valve 3/8” BSP-M
Filter
Manual of instructions

5
3.- TECHNICAL FEATURES
Maximum suction high: 2 m
Minimum injection pressure: 0,5 Bar
• IP 65 protection.
• Ambient temperature temperature: 5-40 ºC
• Standard power supply: 230 V (+/-10%) a.c.50 / 60 Hz single phase.
• Optional power supply:120 V a.c. 50 / 60 Hz single phase. / 12V d.c.
• Liquid temperature temperature: 5-40 ºC
LIQUID ENDS MATERIALS:
DIAPHRAGM: PTFE.
PUMP HEAD: PVDF
NIPPLES: PVDF.
VÁLVES BODY: PVDF
VALVES BALL: Ceramic
O-RINGS: FPM ( available in EPDM)
SUCTION HOSE: PVC flexible.
DISCHARGE HOSE : Polyethylene.
FILTER: Polypropylene
FLOW - PRESSURE
bar2 64 8 10
l/h
10
6
2
14
12 1614 18 20
12
8
4
16
1 53 7 9 11 1513 17 19
9 l/h@10 bar
6 l/h@ 7 bar
2 l/h@ 20 bar
2,5 l/h@ 10 bar
Flow
l/h
2.5
2
6
9
2.5
6
C/min
120
120
120
120
120
120
Pressure
Bar
10
20
7
10
10
7
Stroke
length mm
0.8
1.0
1.0
1.4
0.8
1.0
Power
Watts
37
(0.16A)
58 (0.30A)
37 (0.16A)
58 (0.30A)
24 (2 A)
24 (2 A)
Power
supply Volts
230V AC
230V AC
230V AC
230V AC
12V DC
12V DC
Weight
Kg
3
3.8
3
3.8
3
3
Volum
ml/cycle
0.35
0.28
0.83
1.25
0.35
0.83

130
001
5
172
4.- OPERATION
6
The metering pump is activated by a PTFE diaphragm mounted on a piston of
an electromagnet.
When the piston of the electromagnet is attracted, a pressure is produced in
the pump body with an expulsion of liquid from the discharge valve.
Once the electric impulse is finished a spring brings the piston back to the
initial position, with a recall of liquid through the suction valve.
As the operation is simple the pump does not need lubrication, therefore
maintenance is reduced almost to zero.
The materials used for the construction of the pump make it particularly
suitable for aggressive products.
DIMENSIONS
190
210

5.- INSTALLATION
GENERAL
7
Install the pump in a dry place and well away from sources of heat and, in any
case, at environmental temperatures not exceeding 40°C. The minimum
operating temperature depends on the liquid to be pumped,bearing in mind that
it must always remain in a liquid state.
Place the pump vertically over a rigid surface totally horizontal.
HYDRAULIC CONNECTION
Properly design either in the suction and injection pipe is required, avoiding long
lenght and bending pipes as much as possible.
1
6
4
3
2
1
3
2
4
5
6
1
2
3
4
5
6
PRIMING VALVE INJECTION VALVE
SUCTION PIPE COUNTER-PRESSURE VALVE
SUCTION FILTER INJECTION PIPE
a
b
c
d

ELECTRIC CONNECTION
The electric protection of the motor must be installed and adjusted
following its nominal intensity (overloaded switch disjuntor).
A disconnection dispositive must be installed in case of emergency.
The equipment must be protected to avoid untimely sudden starts.
8
Install a safety valve in a derivation as near as possible
from the pump , in order to protect it and the whole
installation from possible over-pressures. This derivation
Must derive the liquid to a safe place.
To prime the pump, first connect the priming
hose to the priming valve and drive the
other side of the hose to a safety place to
pour the air mixed with product.
Open the priming valve and start the pump
at maximum flow until having only liquid in
the priming outlet.
PRIMING
VALVE
PRIMING
HOSE
Select the most appropiate injection point in
the pipe to inject the product, and place
there a 3/8” part to connect the Injection
valve.

9
L1 (BLUE)
L2 (BROWN)
YELLOW /GREEN
230V AC
MD Q mA PRC
1
2
3
4
A
B
C
D
E
1
2
3
4
1
2
3
4
1
2
3
4
123- Pulse input (+)
4- Pulse input (-)
123- Level switch
4- Level switch
1-Output relay.AL3.NO
23-Output relay (Com)
4-
123- Signal mA (+)
4- Signal mA (-)
1- Alarm relay (NO)
2- Alarm relay (NC)
3- Alarm relay (Com)
4-
Connector BNC
pH sensor
ORP (redox) sensor
123- Level switch
4- Level switch
123- Level switch
4- Level switch
1- Output mA (+)
2- Output mA (-)
3- Level switch
4- Level switch
A
B
C
D
E
MF
123- Ground
4- Reset
1- Alarm relay (NO)
2- Alarm relay (NC)
3- Alarm relay (Com)
4-
1- Flow sensor.
2- Flow sensor.
3- Level switch
4- Level switchl
1
2- Signal input mA (-)
3- Pulse input (+)
4- Pulse input (-)
- Signal input mA (+)
Electrical connection of the dosing pump with electric loads (motors, pumps,
electrovalves...)
To avoid damaging the dosing pump (DP) at the disconnection of other pumps or
electric motors (M), the following diagrams must be used:
Option 1
Option 2
DP
DP

10
6.- START UP AND REGULATION
BASE: Check that the pump is properly secured to the base.
CHECKING THE HYDRAULIC CIRCUIT: Check that all valves are
open and the liquid from priming valves are derived correctly
CHECKING OF PUMP: Visually/hearing check the proper operation of
the pump.
OVER-PRESSURE PROTECTION: Adjust the safety valve to the
correct pressure to protect the installation without exceeding the pump
nominal pressure.
ELECTRIC PROTECTION: Ajust the electric protection to the pump
nominal current.
Replace crystal suction hose with a polyethilene discharge hose. Use
PTFE hose for the suction and discharge.
Previously, take away from inside the pump all water present (if water
is mixed with sulphuric acid, an overtemperature is caused, damaging
the pump.
SULPHURIC ACID DOSIFICATION

11
DOSITEC MP
MANUAL REGULATION DOSING PUMP
Flow regulated with a potentiometer, it control the impulsion frequency. Adjust of
the frequency from 0 to 100%. Special flow regulation at 0-20% frequencies.
1
3
4
2
5
6
7
8
9
1 START
2 STOP
3 Regulation at 20% maximum
4 Regulation at 100% maximum
5 Adjust of the potentiometer in percentage (0-100%)
6 Power LED
7 Injection LED
8 20% regulation LED
9 100% regulation LED
ACCESSORIES
- 1 flexible transparent PVC suction hose 2m
- 1 semirigid white PE injection hose 2m
- 1 injection valve 3/8”
- 1 filter
- 1 user manual
- 1 flexible transparent PVC priming hose.

12
DOSITEC MD
DIGITAL DOSING PUMP WITH MANUAL REGULATION
Flow set with keyboard, from 0 - 100%.
2
3
1
4
5
6
1 Increase value
2 Decrease value
3 START /STOP
4 Display
5 Power LED
6 Injection LED
ACCESSORIES
- 1 flexible transparent PVC suction hose 2m
- 1 semirigid white PE injection hose 2m
- 1 injection valve 3/8”
- 1 filter
- 1 user manual
- 1 flexible transparent PVC priming hose.
LEVEL ALARM
Pump stops, red LED is on when detects no product for 5 seconds. Level sensor
is required.

13
DOSITEC mA
ANALOGIC 4-20mA DOSING PUMP
Dosing pump, flow regulated through a 4-20mA external signal.
6
2
3
7
5
13
14
11
1
1 Displays mA or pulse
2 Increase value
3 Decrease value
4 Select function
5 Enter
6 Pulse LED display.
7 Manual selection LED
8 SET POINT 2 / STOP LED
9 SET POINT 1 / STOP LED
10 Meter LED
11 mA LED display
12 Display
13 Injection LED signal
14 Level alarm LED
ACCESSORIES
- 1 flexible transparent PVC suction hose 2m
- 1 semirigid white PE injection hose 2m
- 1 injection valve 3/8”
- 1 filter
- 1 user manual
- 1 flexible transparent PVC priming hose.
12
10
4 8 9

14
LEVEL ALARM (FAO)
Pump stops, displays FAO, and the alarm LED is on when detecting no product for
five seconds. A level sensor is required.
POWER ON THE PUMP
PRIMING
Select MANUAL function and select the frequency to prime the pump.
F to select MANUAL
+/- to change the injection/min ( a 75% of the maximum frequency is
recommended)
The pump starts with METER, pulse per minute is displayed.
Use mA / pulse, to display input signal / injections per minute.
PROGRAMMING
SET POINT 1
Sets the input signal value for the minimum flow, and the frecuency of the
injections.
F to select SET1/STOP, show the frecuency of the injections set.
+/- to change the frecuency of the injections (puls/min), for minimum flow (000 for
stop)
mA/pulse to select mA.
+/- to change the value of the input signal (mA) for the minimum flow.
Confirm with ENT.
F to select SET POINT 2.

15
SET POINT 2
Sets the value of the input signal for the maximum flow, and the frecuency of the
injections.
F to select SET2/STOP, shows the frecuency of the injections.
+/- to change the frecuency of the injections (pulse/min), for maximum flow.
mA/pulse to select mA.
+/- to change the value of the input signal (mA) for the maximum flow.
Confirm with ENT.
Direct mode
The pump works with an input signal of a higher value than the minimum frecuency
(SET1), increasing the frecuency of the injections (flow), proportionally to the
increase of the signal, to the maximum frecuency of the injections (SET2).
Reverse mode
Increasing the value of the input signal means a reduction of the flow. Maximum
value of the input signal in mA at SET1, and the minimum value in SET2.
NOTE: A higher frecuency at SET1 than at SET2 is not allowed, so the reverse
mode can only be set setting a higher value of the signal (mA) at SET1.
Example 1:
Dositec mA, Flow 10 l/h, Pressure 5 Bar, Signal 4-20 mA
4 mA = 0 l/h = 0%
12 mA = 5 l/h = 50%
20 mA = 10 l/h =100%
Example 2:
Dositec mA, Flow 10 l/h, Pressure 5 Bar, Signal 4-20mA programmed in Reverse mode.
4 mA = 10 l/h = 100%
12 mA = 5 l/h = 50%
20 mA = 0 l/h = 0%

16
FF
START
STOP
1XN(M)
1XN
NN
1:N
Q
MAN
100%
DOSITEC Q
PROPORTIONAL DOSING PUMP
Dosing pump with a water counter input. Sets a proportion between the pulses
from the water counter and the injections of the dosing pump.
1
3
4
2
5
6
7
8
9
1 Decrease value
2 Increase value
3 Select function
4 START / STOP
5 Display
6 Manual LED
7 Injection LED
8 1xN LED 192.168.240.201:5
9 1xN(M) LED
10 1:N LED
ACCESSORIES
- 1 flexible transparent PVC suction hose 2m
- 1 semirigid white PE injection hose 2m
- 1 injection valve 3/8”
- 1 filter
- 1 user manual
- 1 flexible transparent PVC priming hose.
10

17
MAN
1:N
1XN
1XN MODE
FF
LEVEL ALARM (AL1)
Pump stops, displays AL1 and the alarm LED is on when detecting no product for
five seconds. A level sensor is required.
PROGRAMMING
MANUAL MODE
F to select function.
1)Select injection frequency with .
2)Confirm with START/STOP.
3)START/STOP to start.
PROPORTIONAL MODE
F to select function.
1)Set proportion value with
2)Confirm with START/STOP.
3)START/STOP to start
Note: N max. = 999.
1XN MODE
.
For each pulse received by the water counter, injects N times. Frecuency of the
injections is set in manual mode.
Example:
- Pump in 1XN mode.
- Value N=20
1XN(M) MODE
1XN(M)
1:N MODE
FF

18
Water counter gives a pulse to the pump. The pump dosifies 20 injection strokes,
while the pump is dosing pulses from water counter are ignored. Once the pump
has finished 20 strokes, it waits for another pulse of the water counter to start
again.
1XN (M) MODE
Example:
Pump receives a pulse and injects "N" times at the maximum frecuency
(120pulse/min).
When it receives a second pulse, time between both pulses is used to calculate
the injection frecuency so injection strokes are spaced in time, the limit is the
maximum frecuency.
When the pending injection cycles are higher than 4, AL3 is displayed, pump
continues dosifying, but the pending cycles are missed.
1:N MODE
The pump needs to receive N pulses to inject once. N is set for the user.
Example:
- Pump set mode 1:N
- Value: N=20
After receiving 20 pulses of the watermeter, the pump injects once.
The same as 1xN mode, but injection frequency is adapted to the time between
each pulse received. If the pump receives pulses while it is dosing, injection
frecuency is increased if possible.
Overpulse Alarm (AL3)
NOTE: 70 pulses/second is the maximum frecuency accepted from the
watercounter.
PRIMING
Pump fast priming, press at the same time
.

19
DOSITEC PRC
PH, ORP (REDOX) DOSING PUMP
Microcontrolled dosing pump for PH or ORP (redox) control.
1
3
4
2
6
7
8
9
1 Decrease value
2 Increase value
3 ESCAPE
4 On/Off
5 ENTER
6 Display
7 Power LED
8 Injection LED
9 Alarm LED
ACCESSORIES
- 1 flexible transparent PVC suction hose 2m
- 1 semirigid white PE injection hose 2m
- 1 injection valve 3/8”
- 1 filter
- 1 user manual
- 1 flexible transparent PVC priming hose.
5

20
DEFAULT PARAMETERS
Measure selection pH
Setpoint 7.2
Hysteresis 0.1
Control ácido
ON/OFF - Proporcional control ON/OFF
Proportional control start value Set point+1pH
First point calibration procedure --Second point calibration procedure --Lowest Alarm value 0.00
Highest Alarm value 14.00
Over-dosing alarm value 99:59 (h:m)
Menu: BASE / FULL BASE
Password Disabled
Delay powering on 00:03 (m:s)
Delay exit calibration menu 05:00 (m:s)
Calibration 4 mA output 4 mA
Calibration 20 mA output 20 mA
TYPICAL CHARACTERISTICS
Room temperature 0-40ºC
Max. Current relay output 6A (resistive load)
1A (inductive load)
4-20mA output 4-20mA (dynamic 0-500Ohm)
pH measure 0-14 (0.01 pH)
ORP (mV) measure -1000 - +1400 (+/-1mV)

21
LEVEL ALARM
Pump stops, LEVEL and ALARM are displayed, and yellow LED is on when the
pump detects no product for 5 seconds. A sensor level is required.
PROGRAMATION
Selection of the parameter to control.
First time pump is on, the parameter is flashing
(default parameter is pH).
+/- to change parameter.
Press ENT, use +/- to select the menu:
SETUP ENT to select
Menu available: BASE(default) / FULL
Press ENT to enter SETUP menu:
+/- to select parameter to control pH, mV
Confirm with ENT.
Confirm with ENT.
SETUP
pH
pH
SETUP
MENU
CALIB
MENU
ALARM
MENU
SETUP
MENU
SETUP
MENU
SETUP
SETUP
pH
MENU
SETPOINT
MENU

22
Password:
OFF: password disabled
Use +/- to set a password first digit, press ? to
go to the next digit.
Confirm with ENT.
Level or flow sensor. +/- to select LEVEL to connect
a level sensor, or for a flow sensor.
Confirm with ENT.
Time to exit the menu after the last button pressed.
+/- to change value.
Confirm with ENT.
Delay time to activate the pump.
+/- to change value.
Confirm with ENT.
To solve problems of inertia of some electrodes, or installations, the delay time
switch on of the pump can be set.
CALIBRATION press ENT to calibrate
pH calibration:
POINT 1.
Put the sensor in buffer solution pH7.
+/-, to modify value on the display to get 7.00.
Confirm with ENT.
POINT 2
Wash the sensor with water and put it in the second
buffer solution (pH 4 or pH9).
+/- to modify value on the display to get the value of
the buffer solution.
Confirm with ENT.
INPUT MODE
LEVEL
MENU
SETUP
MENU
SETUP
MENU
CALIB
DELAY h:m:s
DELAY h:m:s
STARTUP
MENU
CALIB
CALIB
pH
2
POINT
CALIB
pH
1
POINT

23
ORP (redox) calibration:
POINT 1: Short circuit the BNC connector.
+/- to select 0.
Confirm with ENT.
Point 2: Connect the sensor and put it in the chemical solution (250, 475, 650 mV).
+/- to select the same value of the chemical solution used.
Confirm with ENT
SET POINT ENT to set the setpoint.
+/- to set the set point value.
Confirm with ENT
Select dosing method. If the pump has to dosify to
increase the reading to reach the set point or
decrease the reading. To dosify acid, select , to
dosify alkaline product .
+/- to select. Confirm with ENT.
HYSTERESIS (only in FULL menu) , is the diference
from the set point where the pump starts or stops.
+/- to change value.
Confirm with ENT.
Type of control.
ON-OFF: to get the set point, the pump works at a
fixed frecuency.
+/- to select. Confirm with ENT.
PROP: Frecuency of the dosing depends on the
reading and the set point distance.
+/- to select. Confirm with ENT.
MENU
SETPOINT
SET
pH
POINT
SET
DIRECTION
POINT
HYST
POINT
SET
pH
MODE
SET
ON-OFF
POINT
MODE
SET
PROP.
POINT

25
Minimum value where the alarm is on, and stops the
dosing. When the reading goes to a correct value the
pump is on with the alarm registered on the screen.
+/- to change.
Confirm with ENT.
OVER DELAY, maximum time to get the set point.
If this time is over
OVER DELAY alarm is on, and the
dosing is stop.
+/- to change. Confirm with ENT.
RESET (partial or total)
Switch off and on.
Press ENT press + and -
simultaneously
Partial Reset parcial gets default settings, but the calibration parameters are not
lost.
Press: -, -, .
Total reset gets all the default settings..
Press: +, +, .
STAND-BY pump is stop
Press + and - simultaneously untill
Press + and - to exit.
ALARM
pH
min
MENU
SETPOINT
RESET
RESET
RESET
ALARM
OVER DELAY
pH
h:m

26
DOSITEC MF
MULTI-FUNCTION DOSING PUMP
Dosing pump allows a manual flow regulation, a proportional dosing refered to a
pulse input rate, 4-20mA analogical external signal, o with a timer.
1
3
4
2
6
7
8
9
1 Decrease
2 Increase
3 Previous program
4 Next program
5 START / STOP
6 Display
7 Power LED
8 Injection LED
9 Alarm LED
ACCESORIES
- 1 flexible transparent PVC suction hose of 2m (6.56 feet)
- 1 semi rigid white PE injection hose of 2m (6.56 feet)
- 1 injection valve 3/8”
- 1 filter
- 1 user manual
- 1 flexible transparent PVC priming hose.
5
MF
START
STOP

27
MENU SELECT
MANUAL
LEVEL ALARM
Pump stops when the pump detects no product for 5 seconds. A sensor level is
required.
PROGRAMMING
First screens
Confirm with START/STOP.
Pump starts at the selected frecuency.
MENU SELECT
1xN
MENU SELECT
1xN(M)
MENU SELECT
mA
MENU SELECT
PPM
MENU SELECT
MANUAL
MENU SELECT
PULSE / MIN.
MENU SELECT
PULSE / HR.
MENU SELECT
PULSE / DAY
to select
pulse/minute
PULSE / MINUTE
120
to select pulse/hour
PULSE / HOUR
120
to select pulse/day
PULSE / DAY
48
Dosing control modes. MANUAL / 1xN / 1xN(M) / 1:N / mA / PPM
MANUAL MODE
Pump runs a constant dosing. Frecuency of the injections can be set upon three
different scales.
MAN. 120P/M
00:00
MENU SELECT
1-N
MENU SELECT
ALARM
MENU SELECT
REMOTE
MENU SELECT
BUZZER
MENU SELECT
CLOCK
MENU SELECT
TIMER
MENU SELECT
LENGUAGE

28
PROPORTIONAL MODE
Proportional dosing between the pulses of the water counter, and the pump
injections.
1XN MODE
For each pulse received, the pump injects "N" times. N is set by the user,
frecuency is set in manual mode.
Example:
- Pump set on 1XN mode.
- N= 20
- When the pump receives a pulse, it starts dosing 20 injections. If the pump
receives another pulse while it is dosing, the pulse is ignored. When the pump
finishes the 20 injections, it can accept another pulse.
1XN (M) MODE
Works as 1xN mode, but frecuency of the pump is adjusted to time between pulses
received. If the pump received a pulse while it is dosing, it is memorized and
adjusts the frecuency again.
Overpulse alarm (AL3)
When the number of pulses remaining to inject is higher than 4xN, AL3 is
activated. The pump continues working, but the pending injections are not done.
Example:
Pump receives a pulse, dose "N" injections at the maximum frecuency (120
injection/minute).
At the second pulse received, the pump adjust the injection frecuency to the time
between first and second pulse. Maximum límit is maximum frecuency.
MENU SELECT
1xN(M)
MENU1xN(M)
10
to set “N” injections .
Confirm with START /STOP.
1xN(M) n=10
12:00
to set “N” injections.
Confirm with START/STOP
1x N n= 10
12:00
MENU SELECT
1xN
MENU 1xN
10

29
1:N MODE
For each N pulses received the pump injects once. N is set for the user.
Example:
- Pump set on 1:N mode.
- N= 20
- When the pump receives 20 pulses, injects once.
to select the number of
pulses.
Confirm with START /STOP.
1- N n= 10
12:00
MENU SELECT
1-N
MENU 1-N
10
mA MODE (4-20mA)
Frecuency of the injection is adjusted by an external 4-20mA signal. Minimum and
maximum injection frecuency can be set.
MENU SELECT
mA
SET mA (1)
4.0
SET mA (2)
20.0
PULSE / MIN (1)
0
to select flow(injections/ minute) of the
signal SET mA (1).
Confirm with .
PULSE / MIN (2)
120
to select flow (injections/ minute) of the
signal SET mA(2).
Confirm with .
BELOW mA (1)
CONTINUE
to select STOP or CONTINUE the
dosing when signal value is below SET mA
(1).
Confirm with .
BELOW mA (1)
STOP
to select minimum mA of the signal.
Confirm with .
to select maximum mA of the signal.
Confirm with
.

30
OVER mA (2)
CONTINUE
OVER mA (2)
STOP
Pres START/STOP to start running according the
configuration set.
mA :00.0
12:00
PPM MODE
. Doses in Parts Per Million
MENU SELECT
PPM
L/P W.METER
0.10
to select liters/pulse of the flowmeter.
Confirm with .
cc/ INJECTION
0,01
to select the injection volume/cycle
(ml/cycle) (page 5).
Confirm with .
SOLUTION %
100
to select the concentration value (%) of
the product to inject.
Confirm with .
SET PPM
1.0
to select the set point in p.p.m (Parts
Per Milion), between 0,01-2000 ppm.
Confirm with .
START/STOP, to start running according the configuration
set.
PPM = 1.0
12:00
ALARM
Pump stops, yellow led is on, and the buzzer is activated when the pump detects
no injects product programmed (some parameters must be set). A flow sensor is
required.
MENU SELECT
ALARM
REF. PULSES
0
MAX DIFF.
0
number of reference pulses.
Confirm with .
select maximum distance of the ref
pulses accepted.
Confirm with .
to select STOP or CONTINUE the
dosing when signal value is over SET mA
(2).
Confirm with .

31
REMOTE ACTIVATION
The pump can be activated with a contact at a maximum distance of 100 meters.
(3-4 Connector C, page 9).
Open contact activation(NORMAL), close contact activation(REVERSED).
MENU SELECT
REMOTE
MENU REMOTE
NORMAL
MENU REMOTE
REVERSED
REVERSED
Open contact: pump off
Close contact: pump on
Confirm with .
to select.
NORMAL
Open contact: pump on
Close contact: pump off
select.
Confirm with .
to
BUZZER
Buzzer shows if the pump alarm is on.
MENU SELECT
BUZZER
MENU BUZZER
ENABLED
MENU BUZZER
DISABLED
ENABLED
to select.
Confirm with .
DISABLED
select.
Confirm with
.
to
CLOCK
MENU SELECT
CLOCK
CLOCK SET
“12:00" - MON
select time.
Confirm with .
CLOCK SET
“2007" JAN 01
select year
Confirm with .
CLOCK SET
12:00 - “MON”
select day.
Confirm with
.

32
TIMER
Timer in a day can activate 8 cycles start-stop of the pump.
MENU SELECT
TIMER
MENU TIMER
TIMER OFF
TIMER OFF
select the function.
Confirm with .
SUNDAY SET1
ON 1:00
SUNDAY SET 1 ON .
select time.
Confirm with .
MENU TIMER
WEEK SETS
WEEK SETS maximum of 8 start-stop cycles
in a week.
select function.
Confirm with .
MENU TIMER
DAILY SETS
DAILY SETS number of cycles start-stop in a
day (max 8).
select function.
Confirm with .
SET1
OFF 1:20
SET1 OFF stop time.
select time, hour: minute.
Confirm with .
SET1
ON 1:00
SET1 ON start time.
select time hour:minute.
Confirm with .
Repeate depending the number of cycles (max. 8) required
per day.
CLOCK SET
2007 JAN “01"
select the day.
Confirm with .
select the month.
Confirm with .
CLOCK SET
2007 “JAN” 01

33
SUNDAY SET1
OFF 1:20
Repeate for cycles number of each day of the week.
Maximum 8 for each day.
SUNDAY SET 1 OFF Sunday stop time.
.
Confirm with .
to select time
LANGUAGE
Select language.
MENU SELECT
LANGUAGE
SET LANGUAGE
ENGLISH
English.
select language.
Confirm with .
MENU LINGUA
ITALIANO
Italian.
select language.
Confirm with .

34
7.- MAINTENANCE
Periodically check the chemical tank level to avoid the pump
operates without liquid. This would not damage the pump, but
may damage the process plant due to lack of chemical.
DOSITEC series dosing pumps are all supplied with level control
setting. The level switch is not included therefore to be ordered
separately.
Level control stops pump operation once the level into the
chemical is lower then the level switch,activating a L.E.D. on the
pump .
Check the pump operating condition at least every 6 months,
pump head position,screws, bolts and seals; check more
frequently when aggressive chemicals are used.
Is recomended to clean periodically the hydraulic part(valves and
filter). Cleaning frecuency will depend on the aplication.
Before any maintenance operation check:
The pump is stopped and disconnected from the electric supply.
There is no pressure neither inside the head nor in the impulsion
pipe. It is advisable to empty the head before opening it.
The staff in charge of the maintenance will use the adequate
protection means in order to manipulate the dosed liquid.

CAUSE
Valves not clean
Damaged valves
Filter not clean
Power supply
failure
START failure
Power supply
failure
PROBLEM
The pump gives pulses but
doesn’t inject
The pump doesn’t give
any pulse and LED are off
The pump gives only one
pulse
The pump doesn’t give
any pulse and green LED
is on and red LED is off
Pump pulses are not
constant
TROUBLE SHOOTING
MECHANICAL FAULTS
As the system is quite robust there are no apparent mechanical problems.
Occasionally there might be a loss of liquid from the nipple because the tube nut
has loosened, or more simply the discharge tubing-has broken.
Very rarely there may be losses caused by the breakage of the membrane, or by
the membrane seals in which case they have to be replaced by disassembling the
four screws of the pump head, when re-mounting the pump head ensure that the
screws are replaced properly, along with “O” ring.
After repair, the metering pump will need to be cleaned of additive residues which
can damage the pump case.
35
SOLUTIÓN
Remove the suction and injection
valves, clean them , and assemble
them in the same position.
When the parts are swallen, check
valve material against a chemical
compatibility chart and fit the correct
material.
Clean the filter
Chech the power supply. If it still
doesn’t work contact with the
Technical Service
Press START/STOP.
If it still doesn’t work contact with the
Technical Service.
Check the input voltageis within +/10% rated voltage
Disconnect the pump and contact
immediately to the Technical Service

DOSITEC PARTS
36
59-050.1-F
59200
59215
59154
59631
59300
59602 59605 59608
59603 59606
59604 59607
59155
59310
59213
59158
59159
59160
59308
59212
59609
59610
59611
59203
59204
59205
59210
59211
59206
59207
59208
59612
59613
59614
59201
59615
59616
59617
Fusibles:
59315
59316
59161
59162
59307
59209
59-050.1-F
59-050.1-T
59-050.1-T

59817
59802
59813
59812
59824
59811
18-313
18-312
59-806
59-851-P
CHECK VALVE 4X6 PP
FOOT FILTER 4X6 PP
KIT ACCESORIOS DOSITEC PP 59-049-P
HOSE 4X6
PE
PVC
KIT ACCESORIOS PVDF 59-049-F
59-806-F
59-851-F
18-385
FOOT FILTER 4X6 PVDF
HOSE 4X6 PTFE
CHECK VALVE 4X6 PVDF
37

38
LIST OF PARTS
CODE DESCRIPTION UNITS
59154 Connector female 4 pins Dositec 2
59155 Conector g4a5m Dositec 2
59157 Cylinder cap 4
59158 Diaphragm backseat Dositec 2.5 1
59159 Diaphragm backseat Dositec 6 1
59160 Diaphragm backseat Dositec 9 1
59161 Diaphragm backseat Dositec 2-20 1
59162 Diaphragm backseat support Dositec 2-20 1
59200 Diaphragm PTFE Dositec 1
59201 Lower lexan Dositec 1
59203 Lexan MP 1
59204 Lexan MD 1
59205 Lexan Q 1
59206 Lexan mA 1
59207 Lexan MF 1
59208 Lexan PRC 1
59209 Cylinder cover 1
59210 Hydraulic case 1
59211 Electronic case Dositec 1
59212 Flow adjustment knob 1
59213 O-ring case 1
59215 Diaphragm PTFE Dositec 2-20 1
59300 Screw M4x8 A2 4
59303 O-ring 4,76 x 1,78 FPM priming valve 2
59307 O-ring 48.89x2.62 FPM 1
59308 Screw 2,9x9,5 4
59309 Screw 4x16 6
59310 Screw 2,9x13 2
59315 Fuse 1A Dositec Q/PRC 1
59316 Fuse 1A 20x5 Dositec MP/MD/mA/MF 1
59602 Electromagnet D80 2/12V 1
59603 Electromagnet D80 6-7 12V 1
59604 Electromagnet D90 9-5 12V 1
59605 Electromagnet D80 2-10 1
59606 Electromagnet D80 6-7 1
59607 Electromagnet D90 9-10 1
59608 Electromagnet 2-20 1
59609 Electronic card Dositec MP 12Vdc 1
59610 Electronic card Dositec MP 1
59611 Electronic card Dositec MD 1
59612 Electronic card Dositec Q 1
59613 Electronic card Dositec mA 1
59614 Electronic card Dositec MF 1
59615 Electronic card Dositec PRC 1
59616 Electronic card (power)12Vdc Dositec MF 1
59617 Electronic card (power) 230Vac Dositec MF 1
59631 Connector female 4 pins Dositec ALM 1
59800-F Drain connector Dositec PVDF 1
59801-F Spacer of injection valve PVDF 1
59802 Nut for 3/8"" lip valve connector 1
CODE DESCRIPTION UNITS
59807-F Drain knob PVDF 1
59809-F Screw for priming Dositec PVDF 1
59810-F Drain rod Dositec PVDF 1
59811 Cylinder for injections valve 1
59812 Body of injections valve 1
59813 PP fiber foot filter 4x6-3/8 1
59814 Lip valve for foot filter 1
59817 Foot filter body 1
59824 Connector for foot valve 4x6 with filter 1
59829 Nut for 3/8' valve connector PVDF 1
59830 Valve flange pipe 4x6 PVDF 1
59831 Valve connector pipe 4x6 PVDF 1
ASSEMBLIES
59-050.1-F Cylinder Dositec assembly PVDF FKM 1
59-806 Injection check valve 4x6 3/8 1
59-851-P Foot check valve 4x6 with PP fiber filter 1
OPTIONS & ACCESORIES
18311 Floating level switch
18385 Hose 4x6 PTFE Dositec
59-049-F Kit accessories Dositec PVDF
59-050.1-T Cylinder Dositec assembly PVDF EPDM
59-080-F Cylinder with automatic degassing valve
assembly PVDF
59101 Plate for level sensor stand
59-806-E Injection check valve 4x6 3/8 EPDM
59-806-F Injection check valve ball 4x6 ½ PVDF
59-851-F Foot check valve 4x6 with PVDF filter

I.T.C. S.L. warrants the product specified in this document for a period of 2
years fromt he purchase date except for the wearing parts such as valves,
seals, nipples, hoses and filter. This warranty obligation is limited to the
free replacement of the damaged parts due to any material or manufacture
defect. This warranty does not include periodic maintenance and damage
resulting from misuse.
The equipment must be sent to I.T.C. S.L. Service Center with prepaid
transport charges, and will be sent back with transport charges for
customer’s account.
The warranty document with sales date and shop stamp or an invoice copy
must be sent with the equipment.
W YTNARRA
Date of sale and shop stamp
DATE:
SERIAL #
MODEL
EC CONFORMITY DECLARATION
I.T.C S.L..
Mar Adriàtic, 1
Polígono Torre del Rector
08130 Santa Perpètua de Mogoda
Declares that all models DOSITEC products, identified by a serial number and
year of manufacture, strictly fulfill low voltages directives D2014/35/UE and
electromagnetic compatibility directives D2014/30/UE as long as installation,
use and maintenance are carried out following the prevailing regulation and
following the instructions contained in the handbook.
Antón Planas
Manager

C/ Del Mar Adriàtic nº 1 Pol. Ind. Torre del Rector
P.O. Box 60
08130 STA. PERPETUA DE MOGODA
BARCELONA - SPAIN
Tel. 935 44 30 40 Fax 935 544 31 61
e-mail: itc@itc.es www.itc.es
Ed:19/05/2017-AN