ITC Avoximeter 1000E User Manual

4.5 (4)

AVOXimeter® 1000E

Whole Blood Oximeter

Operator’s Manual

Manufacturing Company Location

International Technidyne Corp

8 Olsen Avenue, Edison, New Jersey USA

Phone: 1-732-548-5700 Fax: 1-732-248-1928

web site: www.itcmed.com

Copyright and Trademarks

Copyright© 2007 International Technidyne Corporation (ITC). All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of ITC.

ITC and AVOXimeter are registered trademarks of International Technidyne Corporation in the United States and other jurisdictions.

U.S. Patents. 5,430,542 and 6,262,798. Euro/UK Patent 0663070. Other patents pending.

Technical Support

Contact ITC Technical Support at (800) 631-5945 or (732) 548-5700, or by e-mail at techsupport@itcmed.com.

ii

Table of Contents

 

1

INTRODUCTION .......................................................................................................

1

 

Intended Use of the ITC AVOXimeter 1000E ............................................................

1

 

Summary and Explanation of the Test.......................................................................

1

 

Hemodynamic Calculations ...........................................................................

2

 

Saturation Step-Ups ......................................................................................

3

 

Operating Precautions and Warnings ........................................................................

5

 

Limitations..................................................................................................................

5

2

DESCRIPTION ..........................................................................................................

6

 

Front Panel ................................................................................................................

6

 

Keypad.......................................................................................................................

7

 

Menus .......................................................................................................................

8

 

Test Cuvettes.............................................................................................................

9

 

Connections .............................................................................................................

10

 

Automatic Standby and Shutdown...........................................................................

10

 

Instrument Lockouts.................................................................................................

10

 

Instrument Specifications.........................................................................................

11

 

Reportable Range........................................................................................

11

 

Accuracy ......................................................................................................

11

 

Precision ......................................................................................................

11

 

Interference..................................................................................................

11

 

Calibration................................................................................................................

12

3

GETTING STARTED ...............................................................................................

13

 

Unpacking and Inspection........................................................................................

13

 

Materials Provided .......................................................................................

13

 

Materials Required But Not Provided ..........................................................

13

 

Optional Materials........................................................................................

14

 

Charging the Batteries .............................................................................................

14

 

Setting Up the Instrument ........................................................................................

15

 

Setting Display Backlighting ........................................................................

15

 

Specifying Units for Total Hemoglobin (THb) ..............................................

15

 

Changing the Date and Time.......................................................................

16

 

Setting the Standby Delay ...........................................................................

17

 

Specifying Mandatory Entry of User ID and/or Patient ID........................................

18

 

Changing the QA User ID ............................................................................

21

 

Requiring Entry of a Patient ID ....................................................................

22

 

Specifying Oximetry Site Prompts............................................................................

23

 

Specifying Use of Oximetry Sites ................................................................

24

 

Entering a Different Value for Hüfner’s Number ..........................................

25

iii

4

OPERATION ...........................................................................................................

27

 

Startup .....................................................................................................................

27

 

Entering a User ID (Optional) ...................................................................................

27

 

Entering a Patient ID (Optional)................................................................................

27

 

Sample Collection and Preparation ..........................................................................

28

 

Sample Collection ........................................................................................

28

 

Sample Preparation......................................................................................

28

 

Running a Test .........................................................................................................

29

 

Using the Printer.......................................................................................................

30

 

Printing the Current Test Results .................................................................

30

 

Specifying Automatic Printing of Results......................................................

30

 

Changing the Serial Port Baud Rate and Parity ...........................................

30

 

Data Management ....................................................................................................

31

 

Printing all Stored Data ................................................................................

31

 

Printing All Optical Quality Control Data.......................................................

31

 

Reviewing and/or Printing the Last Sample .................................................

32

 

Locating, Reviewing, and/or Printing any Sample........................................

32

 

Aborting Printing of Results..........................................................................

33

 

Purging all Test Records ..............................................................................

33

 

Quality Control..........................................................................................................

34

 

Performing Optical Quality Control...............................................................

34

 

Running Liquid Controls ...............................................................................

35

 

Entering Liquid Control Lot Numbers ...........................................................

36

 

Tagging a Liquid Control Test with a Lot Number ........................................

37

 

Enabling QC Lockout ...................................................................................

38

 

Calibration ................................................................................................................

39

 

Cuvette Pathlength.......................................................................................

39

 

Re-Calibration ..............................................................................................

39

 

Shutdown..................................................................................................................

40

 

Hemodynamic Calculations ......................................................................................

41

 

Entering the Patient Age, Height, Weight, and Sex......................................

41

 

Oxygen Uptake Rate ....................................................................................

43

 

Body Surface Area .......................................................................................

44

 

Saturation Step-Ups .....................................................................................

45

 

Flow Calculations .........................................................................................

46

 

Systemic and Pulmonary Resistances .........................................................

50

 

Stroke Volume and Stroke Index..................................................................

52

 

Printing Hemodynamic Values .....................................................................

54

 

Troubleshooting........................................................................................................

55

5

MAINTENANCE ......................................................................................................

59

 

Cleaning the Optical Detector...................................................................................

59

 

Replacing the Battery ...............................................................................................

63

iv

6

QUALITY CONTROL LOGS ...................................................................................

65

7

WARRANTY ............................................................................................................

68

 

Certification, Warranty and Service Warranty, and Service .....................................

68

8

SAFETY STANDARDS ...........................................................................................

70

 

Guidance and Manufacturer’s Declaration – Electromagnetic Emissions....................

71

 

Guidance and Manufacturer’s Declaration – Electromagnetic Immunity .................

72

INDEX ............................................................................................................

73

v

Important Labels and Symbols

Before using the ITC AVOXimeter 1000E, it is essential that the contents of this Operator’s Manual, any labels on the instrument or its packaging, and instructions accompanying ITC AVOXimeter 1000E cuvettes are read and understood by the operator. These materials make reference to additional symbols that are explained below:

Product Conforms to Directive 98/79, 27 October 1998 on In-Vitro Diagnostic Medical Devices

Expiration Date of Cuvettes

Serial Number of Instrument

Lot Number of Cuvettes

ITC Catalogue Number of Devices

Do Not Reuse– Single Use Only

Upper and Lower Temperature Limitations (For Storage or Use)

For in vitro Diagnostic Use

Attention - Read Accompanying Documentation or Instructions

Consult Instructions for Use

Input Port for DC Power Cord from AC/DC Power Module - Polarity, VDC and A Input

Serial Output Port for Data Transfer – RS232C

Temperature Probe Input (ITC AVOXimeter 4000 Only)

Name and Address of Manufacturer

Warning - Biohazard

Medical Equipment per Annex 1A, Item 8 Directive 2002/96/EC For Electronic Equipment Waste – Contact ITC Technical Support @ 1-800-631-5945

vi

ITC AVOXimeter 1000E Operator’s Manual

1 Introduction

Intended Use of the ITC AVOXimeter 1000E

The ITC AVOXimeter 1000E is a battery-operated bedside whole blood oximeter that performs individual point-of-care measurements of oxyhemoglobin saturation (%Hb02) and total hemoglobin concentration [THb] on freshly-drawn or heparin or EDTA anticoagulated whole blood samples. Oxygen content [02] of the blood sample is automatically calculated from the %Hb02 and THb measurements.

No sample preparation is required, and analysis is quickly accomplished by injecting the sample into a disposable cuvette and inserting the cuvette into the instrument. The ITC AVOXimeter 1000E then illuminates the sample with multiple wavelengths, records the optical density of the sample at each of the wavelengths, and computes the results. In less than 10 seconds, the oxyhemoglobin fraction, the total hemoglobin concentration, and the oxygen content of the sample are shown in appropriate units on the liquid-crystal display on the front panel.

Data management capabilities are included with the instrument. These capabilities include storage of up to 500 patient or QC results, designation of quality control levels and lot numbers, tagging of test results with date, time, Patient ID and/or Operator ID, entry of oximetry site and subsite, and printing of results.

The instrument also can calculate ten hemodynamic variables (such as body surface area, estimated oxygen consumption rate, and cardiac output using the Fick principle) from data that are entered by the operator. It can also calculate differences in oxygen saturation between adjacent anatomical sites from which blood samples were taken (saturation step-ups), to aid in diagnosing intracardiac and great vessel shunts.

Summary and Explanation of the Test

The ITC AVOXimeter 1000E measures whole blood %Hb02 and [THb] using disposable singleuse cuvettes. The operator inserts a whole blood sample into a cuvette, the cuvette is inserted into the test chamber on the instrument, and the results are displayed. The results will remain on the display while the cuvette remains in the instrument.

The result can be automatically printed along with the time and date the test was run, the Patient ID, Operator ID, and other information entered. The result is also saved in an internal database, which has the capability to store up to 500 results.

Individual ITC AVOXimeter 1000E instruments can be customized so that optical quality control tests must be performed whenever a specified period of time has elapsed. In addition, up to three liquid control lot numbers for each level of liquid QC can be stored in the ITC AVOXimeter 1000E and can be tagged to the stored or printed liquid QC records. The instruments can also be configured so that only authorized operators can operate the system and that patient IDs are required for each test run.

1

ITC AVOXimeter 1000E Operator’s Manual

The ITC AVOXimeter 1000E measures oxygenated hemoglobin [HbO2], deoxyhemoglobin [HHb], methemoglobin [MetHb], and carboxyhemoglobin [COHb] directly, using novel optics and multiple wavelengths. This reduces interference from dyshemoglobins and other interfering substances such as fetal hemoglobin and bilirubin and minimizes the effects of hemolysis.

The measured values are used to calculate total hemoglobin [THb] and percent oxyhemoglobin saturation [%Hb02] of the sample, using the fractional method described below:

[THb]

=

[HbO2] + [HHb] + [MetHb] + [COHb]

[%HbO2]

=

[HbO2] x 100

 

[HbO2] + [HHb] + [MetHb] + [COHb]

 

 

Oxygen content [O2] of the sample is then calculated:

[O2] =

1.39 x [THb] x [%HbO2]

100

 

where 1.39 is the ml of oxygen assumed to be carried by one gram of oxygenated hemoglobin (Hϋfner’s Number). Depending on your facility protocols, the Hϋfner’s Number stored in the ITC AVOXimeter 1000E can be set at any value in the range of 1.30 to 1.39 (see page 25).

Note: Below is a legend for oxygen saturation terminology used throughout this document:

Abbreviation

Term

Units Displayed

 

 

 

THb

Total Hemoglobin

g/dl

 

 

 

HbO2

Oxyhemoglobin

g/dl

 

 

 

MetHb

Methemoglobin

g/dl

 

 

 

COHb

Carboxyhemoglobin

g/dl

 

 

 

HHb

Reduced Hemoglobin

g/dl

 

 

 

%HbO2

Percent Oxyhemoglobin Saturation

n/a

 

(Fractional Oxygen Saturation)

 

 

 

 

[O2]

Oxygen Content

ml/dl

 

 

 

Hemodynamic Calculations

Based on the results, hemodynamic calculations are performed as described below.

Cardiac Output

=

Oxygen Uptake

 

 

ml/min

[O2] arterial

- [O2] venous

 

2

ITC AVOXimeter 1000E Operator’s Manual

Note: Oxygen uptake rate can either be measured from expired gases, or it can be estimated from the patient’s age, height, weight, and sex (see below).

Body Surface Area

m2

Oxygen Uptakemales

ml/min

Oxygen Uptakefemales

ml/min

Cardiac Index

L/min/ m2

Stroke Volume

ml/beat

Stroke Index

ml/beat/m2

Pulmonary

Blood Flow

ml/min

Total Systemic Resistance mmHg/ml/min

Total Pulmonary

Resistance mmHg/ml/min

Pulmonary to Systemic Flow Ratio

Pulmonary to Systemic Flow Ratio

=0.007185 (Weight kg)0.425 (Height cm)0.725

=157.3 BSA + 10– (10.5 * age + 4.8)

=157.3 x BSA – (10.5 * age + 4.8)

Cardiac Output

=

 

BSA

 

=

Cardiac Output

Heart rate

 

=

Stroke Volume

 

BSA

 

Oxygen Uptake

=[02] Pulmonary Arterial – [02] pulmonary venous

=

Arterial Pressure – Right Atrial Pressure

Cardiac Output

=

Pulmonary Arterial Pressure – Left Atrial Pressure

Cardiac Output

=

Pulmonary Flow

Systemic Flow

%Hb02 Arterial – %Hb02 Venous

=

%Hb02 Pulmonary Venous – %Hb02 Pulmonary Arterial

Saturation Step-Ups

Saturation step-ups are the differences in oxyhemoglobin saturation [%Hb02] between adjacent anatomical sites. These values are used as an aid in diagnosing intracardiac and great vessel shunts. The ITC AVOXimeter 1000E calculates saturation step-ups between the following anatomical sites:

Right atrium and superior vena cava

Right ventricle and right atrium

Pulmonary artery and right ventricle

3

ITC AVOXimeter 1000E Operator’s Manual

Pulmonary vein and left atrium

Left atrium and left ventricle

Left ventricle and aorta

When calculating saturation step-ups, the ITC AVOXimeter 1000E searches the database for all results for each main oximetry site for that patient (sub-sites are ignored), averages the results for each site, and then calculates the saturation step-ups from the average result for each main site. This information can then be printed from the ITC AVOXimeter 1000E.

Note: Use of average readings rather than individual values improves the precision of saturation step-up calculations.

4

ITC AVOXimeter 1000E Operator’s Manual

Operating Precautions and Warnings

For in vitro Diagnostic use.

Do not allow blood, water, or other liquids to enter the instrument.

The ITC AVOXimeter 1000E instrument is designed for use only with ITC AVOXimeter 1000E cuvettes.

Do not re-use test cuvettes.

Always keep cuvettes in sealed bag with desiccant.

When filling cuvette, do not use excessive pressure on the syringe or cause the vent patch to bulge outward by overfilling the cuvette.

For proper calibration and calibration verification, use only the controls recommended in this manual. Controls from other sources may yield erroneous results.

The ITC AVOXimeter 1000E instrument is designed to be used for testing in a stationary position. DO NOT perform testing while carrying or holding the instrument.

In order to charge the ITC AVOXimeter 1000E instrument, the AC power cord should be plugged into an electrical service outlet and the AC/DC power module while the DC power cord from the AC/DC power module is plugged into the DC port in the back of the instrument.

DO NOT expose the ITC AVOXimeter 1000E instrument to extreme temperature (above 35°C, 95°F). Such exposure could affect the performance of any type of electronic instrumentation.

DO NOT drop the ITC AVOXimeter 1000E instrument, and do not use the results if the instrument is dropped during a test.

Only properly qualified personnel should attempt to open and perform work on the ITC AVOXimeter 1000E instrument as identified in this manual.

DO NOT remove the AC/DC power module from the ITC AVOXimeter 1000E instrument by pulling on the cord.

The use of accessory equipment (e.g., printers, etc.) not identified in this manual either in the patient vicinity, or that does not comply with either the equivalent safety requirements of this equipment or UL/IEC 60601-1 or IEC 60601-1-2, may lead to a reduced level of safety with the resulting system.

Any items exposed to human blood, plasma or serum must be handled cautiously as a biohazardous material in accordance with laboratory safety practices and federal and local regulations. Federal, state and local laws and regulations require that hazardous waste be disposed of in a specific manner. Waste material from the ITC AVOXimeter 1000E which may be classified as biohazardous include used cuvettes. It is important that steps be taken to dispose of these materials in accordance with the prevailing regulations in your location.

Limitations

Do not disturb the instrument while a test is in progress. As with all diagnostic tests, ITC AVOXimeter 1000E test results should be scrutinized in light of a specific patient’s condition and therapy. Any results exhibiting inconsistency with the patient’s clinical status should be repeated or supplemented with additional test data.

5

ITC AVOXimeter 1000E Operator’s Manual

2 Description

The ITC AVOXimeter 1000E is a Point of Care device for use at the bedside. It contains a test chamber which performs all operations to measure the oxyhemoglobin saturation (%Hb02), total hemoglobin (THb), and oxygen content (O2) of a whole blood sample after the operator inserts a test cuvette containing the sample into the test chamber.

Each ITC AVOXimeter 1000E is calibrated at the factory. The ITC AVOXimeter 1000E can be operated either from its internal batteries or from the AC adapter. The batteries are charged when the AC Adapter is connected.

Finger Grip

Test Cuvette

Figure 1. ITC AVOXimeter 1000E Oximeter

Front Panel

The front panel (Figure 2) contains the test chamber, a keypad with the key, action and menu keys, number keys, and a display panel. Operator instructions are shown on the display panel, and the operator enters commands and information using the keypad.

When the test is completed, the results are shown on the display panel and stored in system memory.

The display panel is illuminated to enhance visibility in low light conditions. The illumination can be adjusted (or turned off) to conserve power during battery operation.

6

ITC AVOXimeter 1000E Operator’s Manual

Test Chamber Number Keys (Blue)

 

 

 

 

 

 

 

 

Action Keys

 

 

 

 

 

 

 

 

(White)

Display

 

 

 

Enter/On Key

Panel

 

 

 

 

 

 

 

(Red)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Menu Keys

 

 

 

 

 

 

 

 

(White)

Figure 2. Front Panel

Keypad

The routine analysis of blood samples does not require the use of menus or the numeric keypad. However, these enable the user to take advantage of many useful features.

The purpose of each key is summarized below:

Key

and

to

Purpose

Switch the instrument on. Select a command.

Display a menu of commands for calibration, printing, stored data, and shutdown.

Display a menu of commands for entering hemodynamic variables, entering device settings, entering the time and date, viewing battery status, and managing data.

Print the results that are displayed.

Respond to questions that are displayed.

Backspace over a numerical entry (such as a QC lot number) so that it can be corrected.

Return to the previous menu.

Enter characters for Operator IDs or Patient IDs. Enter a character for selection of a command.

7

ITC Avoximeter 1000E User Manual

ITC AVOXimeter 1000E Operator’s Manual

Menus

The principal menus, their commands, and the procedure to access each menu are summarized below:

Note: Press the button at any time to return to the previous menu.

 

Menu

 

Commands

 

Access

 

 

 

 

 

 

 

 

 

 

 

 

Main Menu

 

 

 

 

Press the

key when a test is not

 

 

 

 

 

 

 

 

 

 

 

running or another menu is not active.

 

Calibration

 

 

 

 

Press

followed by

while the

 

 

 

 

 

 

 

 

 

 

 

Submenu

 

 

 

 

 

 

 

 

main menu is displayed.

 

 

 

 

 

 

 

 

Printer Mode

 

 

 

 

Press

followed by

while the

 

 

 

 

 

 

 

 

 

 

 

Submenu

 

 

 

 

 

 

 

 

 

main menu is displayed.

 

 

 

 

 

 

 

 

 

Stored Data

 

 

 

 

Press

followed by

while the

 

 

 

 

 

 

 

 

 

 

 

Submenu

 

 

 

 

 

 

 

 

main menu is displayed.

 

 

 

 

 

 

 

 

Computer Menu

 

 

 

 

Press the

key when a test is not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

running or another menu is not active.

 

Hemodynamics

 

 

 

 

Press

followed by

while the

 

 

 

 

 

 

 

 

 

 

 

Submenu (Page 1)

 

 

 

 

 

 

 

 

computer menu is displayed to display

 

 

 

 

 

Page 1.

 

 

 

 

 

 

 

 

 

Hemodynamics

Submenu (Page 2)

Device Settings

Submenu

Time, Date, and

Battery Submenu

Data Management

Submenu

Press + or - while the hemodynamics submenu is displayed to toggle between Page 1 and Page 2.

Press followed by while the computer menu is displayed.

Press followed by while the computer menu is displayed.

Press followed by while the computer menu is displayed.

8

ITC AVOXimeter 1000E Operator’s Manual

Test Cuvettes

Tests are performed with single-use disposable test cuvettes (Figure 3). Each test cuvette contains a finger grip, filling port, optical window, and a vent patch.

Filling Port

Finger Grip

Optical

Window

Light Path

Vent Patch

Figure 3. Test Cuvette

A whole blood sample is inserted into a test cuvette by connecting a luer lock syringe, slip syringe or capillary tube containing the whole blood sample to the filling port and then gently pressing the syringe plunger to dispense approximately 50 µL of whole blood into the test cuvette. Air escapes from the vent patch at the end of the test cuvette while the whole blood sample is being inserted. The test cuvette (with the syringe still attached) is then inserted into the test chamber of the instrument (see page 28 for details).

Note: Be sure to handle the cuvette either by the edges or by the finger grip. Refer to the package insert accompanying the test cuvettes for storage and handling instructions.

Remove any blood or debris from the exterior of the test cuvette before inserting it into the test chamber.

After filling the cuvette with blood, inspect the vent patches to ensure they are not bulging out. If a vent patch protrudes, discard the cuvette. Do not insert a cuvette with a protruding vent patch into the test chamber.

BIOHAZARD WARNING: Any items exposed to human blood, plasma or serum must be handled cautiously as a biohazardous material in accordance with laboratory safety practices and federal and local regulations. Federal, state and local laws and regulations require that hazardous waste be disposed of in a specific manner. Waste material from the ITC AVOXimeter 1000E which may be classified as biohazardous include used cuvettes. It is important that steps be taken to dispose of these materials in accordance with the prevailing regulations in your location.

9

ITC AVOXimeter 1000E Operator’s Manual

Connections

Connections to the AC Adapter and an optional printer (or a computer) are made at the rear of the instrument (Figure 4).

Use only the AC Adapter provided with the instrument.

Serial No.

Label

AC Adapter

Printer or Computer

Figure 4. Power and Printer Connections

Automatic Standby and Shutdown

The ITC AVOXimeter 1000E enters a low-power standby mode after the instrument has been idle for a specified period of time (the standby delay). The instrument is factory preset for a standby delay time of 60 minutes, but a time of 10 to 180 minutes can be specified (see page 17). To resume normal operation when the instrument is in standby, press and hold down any key for one second.

Note: The ITC AVOXimeter 1000E also enters standby if the battery charge becomes critically low.

The ITC AVOXimeter 1000E shuts down after it has been in standby for 4 hours.

Instrument Lockouts

The instrument can be configured to allow use only by authorized operators and/or to allow use only if Optical Quality Control (OQC) has been performed.

10

ITC AVOXimeter 1000E Operator’s Manual

Instrument Specifications

Size

Weight

Operating Temperature

Battery Type

Operating Time On Battery

Anticipated Battery Life

Power Supply/Chargers

Serial Data Port

Sample Type

Sample Volume

Analysis Time

Analysis Wavelengths

Reportable Range

%HbO2

THb

[O2 Content]

20.3 cm (8.0 in) x 25.4 cm (10.0 in) x 9.5 cm (3.8 in) 1.8 kg (4 lbs)

Room temperature (15°C to 30°C, 59°F to 86°F) Nickel Cadmium (NiCad)

Approximately 8 hours (constant run at medium brightness). Tests may also be run while the ITC AVOXimeter 1000E is plugged into the AC/DC power module.

Approximately 500 charge / discharge cycles

Input: 100 / 240 VAC, 50 / 60 Hz Output: 12 VDC, 830 mA

RS232C Whole blood 50 µL

7 to 10 seconds per sample

5

0 to 100%

4 to 25 g/dL

0 to 35 mL O2/dL

Accuracy

%HbO2

±1 %HbO2

THb (>10 g/dL)

±0.45 g/dL

THb (<10 g/dL)

±0.35 g/dL

Precision

%HbO2

0.5 %HbO2

THb

0.3 g/dL

Interference

Bilirubin

None

Hemolysis

None

Carboxyhemoglobin

None

Methemoglobin

< 1% %HbO2, < 0.2 g/dL THb

 

(THb = 16 g/dL, MetHb < 10%, 7.1 < pH < 7.8)

Fetal Hemoglobin

< 1% %HbO2, < 0.45 g/dL THb

 

(THb = 16 g/dL, HbF < 100%)

11

ITC AVOXimeter 1000E Operator’s Manual

Calibration

The ITC AVOXimeter 1000E is factory-calibrated and employs highly stable state-of-the-art light sources. Factory tests indicate that, when used in accordance with this Operator’s Manual and other instructions, the ITC AVOXimeter 1000E is capable of maintaining its calibration for at least two years.

Should recalibration be required contact an ITC technical support representative for assistance (see page 39).

Proper calibration also requires entry of the correct cuvette pathlength by the user (see page 39) and use of a customary value for Hüfner’s number (see page 25).

CAUTION: If quality control results are not acceptable, erroneous results are encountered, or error messages are displayed, the most likely cause is contamination of the optical detector by blood or debris, which cannot be resolved by re-calibration. Consult the Troubleshooting section for additional information.

12

ITC AVOXimeter 1000E Operator’s Manual

3 Getting Started

Unpacking and Inspection

Note: Inspect each component for damage when unpacking. If damage is observed, contact your shipping representative immediately.

1.Remove any protective packaging that may be present around the instrument.

2.Examine the packaging material to be sure that the AC adapter, connecting cables, or other components have been removed. The materials that are provided are listed below.

Note: Do not discard the packaging material.

Materials Provided

Item

Quantity

 

 

ITC AVOXimeter 1000E Instrument

1

AC adapter

1

Operator’s Manual

1

Optical Quality Control Filters

2

Note: An AC power cord is supplied only for the 110VAC version of the US/Canada/Japan instrument. For all others, the customer must obtain a 3 conductor AC power cord that is compatible with an IEC 320 connection at the power supply AC inlet and any other local requirements.

Materials Required But Not Provided

Item

Quantity

 

 

ITC AVOXimeter 1000E Cuvettes

As Needed

Liquid Controls (Manufactured by IL or RNA)

As Needed

See page 34 for additional information.

 

13

ITC AVOXimeter 1000E Operator’s Manual

Optional Materials

Item

Quantity

 

 

Dymo Printer

1

• 110 V (Part No. SE300-110)

 

• 220 V (Part No. SE300-220)

 

• UK V (Part No. SE300-UK)

 

Printer Paper (Part No. 30270)

As Needed

Charging the Batteries

Charge the batteries before the system is used for the first time.

1.Plug the AC adapter into an electrical service outlet.

2.Connect the AC adapter cord to the power connector on the rear of the instrument.

3.Allow the battery to charge for at least eight hours.

Note: The AC Adapter can remain connected all the time.

4.To ensure adequate charge, leave the instrument connected to the AC adapter for a minimum of eight hours. This eliminates the risk of the instrument powering down during a test.

Fully charged batteries will allow the ITC AVOXimeter 1000E to analyze blood samples continuously for up to 8 hours when the display is set at medium brightness.

Battery power can be conserved by:

Reducing (or turning off) display backlighting (see page 15).

Reducing the standby delay (see page 17).

Note: The batteries can suffer from a “memory effect” if they are charged before being completely discharged. For optimal battery performance, discharge completely when possible before charging them. The message “Battery Critical – Connect Charger” will be displayed when the battery is completely discharged.

The message “Battery Critical – Connect Charger” is displayed and the instrument reverts to the standby mode if the battery power is insufficient to complete the test. The AC Adapter must be used for additional tests until the battery is recharged.

Checking the Battery:

1.Display the “Time, Date, and Battery” menu (a submenu of , see page 8).

2.Press followed by to display the battery status:

14

ITC AVOXimeter 1000E Operator’s Manual

3.Press to display the time, date, and battery menu again.

4.Press to return to the previous menu, if desired.

Setting Up the Instrument

The user can specify the display brightness, specify the units that are used for reporting total hemoglobin (THb), change the date and time, and specify the length of time that the instrument is idle before it enters the standby mode.

Setting Display Backlighting

Lighting of the display can be reduced to conserve battery power or increased to improve visibility.

1.Display the “Device Settings” menu (a submenu of , see page 8).

2.Press followed by to display the screen for changing the backlighting:

3.Select the backlighting level (or turn it off) by pressing the corresponding number key followed by . The backlighting changes accordingly.

4.Press to display the “Device Settings” menu again.

Specifying Units for Total Hemoglobin (THb)

Measured values of total hemoglobin can be expressed in units of mmol/L or g/dL.

1.Display the “Device Settings” menu (a submenu of , see page 8).

2.Press followed by to display the screen for changing the units for total hemoglobin:

3.Press followed by to change the units.

4.Press followed by when the desired units are displayed. The “Device Settings” menu is again displayed.

5.Press to return to the previous menu, if desired.

15

ITC AVOXimeter 1000E Operator’s Manual

Changing the Date and Time

Changing the Time:

Important: The User ID for the “QA User” must be entered in order to change the time. See page 21 for details.

1.Display the “Time, Date, and Battery” menu (a submenu of , see page 8).

2.Press followed by to display the current time:

3.Press followed by to change the time:

4.Use the number keys to enter the new time, then press . The new time is displayed.

Note: The time is displayed in 24-hour format. For example, 3:30 pm is displayed as 1530.

5.Press followed by . The “Time, Date, and Battery” menu is again displayed.

6.Press to return to the previous menu, if desired.

Changing the Date:

Important: The User ID for the “QA User” must be entered in order to change the date. See page 21 for details.

1.Display the “Time, Date, and Battery” menu (a submenu of , see page 8).

2.Press followed by to display the current date:

16

ITC AVOXimeter 1000E Operator’s Manual

3.Press followed by to change the date:

4.Use the number keys to enter the new date, then press . The new date is displayed.

5.Press followed by . The “Time, Date, and Battery” menu is again displayed.

6.Press to return to the previous menu, if desired.

Setting the Standby Delay

The instrument enters a low-power Standby mode after being inactive for a specified length of time (the Standby Delay). The instrument is factory preset for a standby delay time of 60 minutes, but a time of 10 to 180 minutes can be specified.

1.Display the “Device Settings” menu (a submenu of , see page 8).

2.Press followed by to display the standby delay (60 minutes is the factory default value):

3.Press followed by to display the screen for changing the standby delay:

4.Use the number keys to enter the new standby delay (or disable the standby delay), then press . The new standby delay is displayed.

5.Press followed by . The “Device Settings” menu is again displayed.

6.Press to return to the previous menu, if desired.

17

ITC AVOXimeter 1000E Operator’s Manual

Specifying Mandatory Entry of User ID and/or Patient ID

A User ID and/or Patient ID can be entered for any test. The User ID and/or Patient ID will be included in the results record for tests that are run.

The instrument can be configured so that a valid numeric User ID must be entered before a test result will be displayed. If this option is enabled, the user is prompted to enter (or verify, if it was previously entered) the User ID after the test has started. If a valid User ID is not entered, the instrument locks until a valid User ID is entered.

Enabling the Requirement to Enter a User ID:

Important: The User ID for the “QA User” must be entered in order to enable the requirement to enter a User ID. See page 21 for details.

1.Display the “User and Patient ID” menu (a submenu of , “Data Management,” see page 8).

2.Press followed by to display the current User ID setting:

3.Press followed by . A confirmation prompt is displayed, and the “User ID” menu is displayed:

4.If needed, review the list of authorized users, add or delete authorized users, or print the user list (see below).

5.Press to display the “Data Management” menu.

Disabling the Requirement to Enter a User ID:

Important: The User ID for the “QA User” must be entered in order to disable the requirement to enter a User ID. See page 21 for details.

1.Display the “User and Patient ID” menu (a submenu of , “Data Management,” see page 8).

2.Press followed by to display the current User ID setting:

3.Press followed by . A confirmation prompt is displayed, and the “User and Patient ID” menu is again displayed.

18

ITC AVOXimeter 1000E Operator’s Manual

4.Press to return to the previous menu, if desired.

Note: The current User ID and/or Patient ID must be re-entered if the instrument is idle for longer than 15 minutes or is turned off.

Adding a User ID:

1.Display the “User and Patient ID” menu (a submenu of , “Data Management,” see page 8).

2.Press followed by to display the current User ID setting:

Note: User ID: must be ON to proceed.

3.Press followed by to display the “User ID” menu:

4.Press followed by to display the screen for entering a new User ID:

5.Enter the new User ID, using the number keys, then press . A confirmation screen is displayed.

6.Press followed by to confirm the new User ID. The “User ID” menu is again displayed.

7.Press to return to the previous menu, if desired.

Reviewing Users /Deleting User IDs:

1.Display the “User and Patient ID” menu (a submenu of , “Data Management,” see page 8).

2.Press followed by to display the current User ID setting:

Note: User ID: must be ON to proceed.

19