Isotech Jupiter 4852 Specifications

Page 1
Dry Block Calibrator
http://www.isotech.co.uk/industrial/
35 to 660°C
g
Wide Operating Range to 660°C
g
Fast Response
g
Calibrate Whole Measurement Loop
The Jupiter Dry Block range offers industry-leading performance in an easy to use portable package - ideal for the calibration of thermocouples and platinum resistance thermometers. It has been designed for fast heating and cooling for convenient field use. For flexibility surface sensor and infrared thermometer accessories can be added.
The standard insert can hold up to six thermometers. For larger blocks see the Gemini range.
These award winning calibrators are easy to use and are available in three versions – the Basic, the Site and the ADVANCED. The Basic has a digital display of set and nominal temperature, the Site additionally includes an in­built independent temperature indicator for a reference probe. The ADVANCED controller has inputs for reference and test thermometers with a further range of sophisticated features including automatic temperature cycling, secure data logging and full colour high resolution display.
Jupiter
Isotech is a world leader in temperature calibration, providing many nations with their Primary Standards and operates a full scale UKAS accredited calibration laboratory. We can offer a range of calibration options to meet your requirements.
Benefit from our experience and understanding in calibration at all levels, our evaluation reports, our tutorials and uncertainty calculations.
These models meet the calibration capacity requirements of EURAMET/cg-13/v.01, “EA Guidelines on the Calibration of Temperature Block Calibrators, formerly EA10/13.
All models include I-Cal Easy LOG software and the
ADVANCED models additionally include software to manage logged data and configure the unit, see page 14 for more details.
BASICSITEADVANCED
24
CALIBRATION SOLUTIONS
|
Page 2
Parameter Model
Jupiter 4852
Temperature Range 35°C to 660°C
ADVANCED Range
Stability ±0.015°C @ 100°C ±0.025°C @ 650°C
Display Resolution 0.01°C over whole range
Accuracy: RTD Input Channel ±0.05°C ±0.005% RDG
Accuracy: Thermocouple Input Channel E,J,K,N: ±0.2°C @ 660°C R: ±0.6°C S: ±0.7°C @ 660°C T ±0.2°C @ 150°C
CJC Accuracy ±0.35°C
BASIC/SITE Range
Stability ±0.02°C @ 100°C ±0.03°C @ 650°C
Display Resolution 0.01°C from 30.00 to 99.99°C then 0.1°C: 0.01°C Over PC Interface
COMMON Specifications
Display Accuracy
1
0.5°C
Blackbody Source ±0.3°C
Surface Sensor Calibrator ±0.5°C
Cools from 650°C to 150°C in 60 minutes
Heats from 30°C to 650°C in 20 minutes
Best Performance See Graph
Calibration volume 35mm diameter by 148mm deep
Standard Insert 6 pockets, 2 x 4.5mm, 2 x 6.4mm, 1 x 8.0mm, 1 x 9.5mm diameter, all 140mm deep
Indicator units °C, °F, K
Power 115Vac or 230Vac 50/60Hz 1000 Watts
Dimensions 384H (including handle) x 212W x 312D mm
Weight 8.5kg
(1) Dry Block Mode only: Comparing 6.5mm Well to Display Value.
ADVANCED SITE BASIC
Digital Display of Set and Nominal Block Temperature
Yes Yes Yes
PC Interface Ethernet + USB Host Serial Serial
Test Thermostats Yes - Two Inputs Yes - Single Input No
Independent Temperature Indicator for Reference Probe
Yes Yes No
Up to 3: Two universal
Additional Inputs for Units Under Test
inputs for
Thermocouple or Process
inputs and a further
PRT,
No No
Thermocouple input
Automatic Temperature Cycling
Yes No No
Data Logging Yes - Export to USB No No
Offset Elimination
Choose English, French, Italian or Spanish Language
Yes - block can follow
reference input
No No
Yes - on full colour display No No
In Built Web Server Yes No No
Yes - Suitable for life
Tamper Proof Data
science, automotive and
No No
aerospace applications
UKAS Calibration available for these systems - International Traceability - Best Practice
CALIBRATION SOLUTIONS
See page 14
25
|
Page 3
Jupiter Accessories
dry Blocks
FAST RESPONSE
Metal Block Bath
The Jupiter is supplied with an insert suitable for a wide range of sensors as standard.
Blackbody Source
Add the Blackbody accessory to allow calibration of infrared thermometers.
Surface Sensor Calibrator
The Jupiter can calibrate surface sensors by adding the surface sensor kit.
Metal Block Insert 852-07-11
Standard Insert included. Size: 2 x 4.5mm, 2 x 6.4mm, 1 x 8mm and 1 x 9.5mm all 140mm deep
Alternative Inserts
852-09-03 Alternative Insert type B 13mm,
10mm, 8mm, 5mm and 3.5mm diameter holes, all 140mm deep
852-09-04 Alternative Insert type C 8mm, 6
x 6.5mm diameter holes, all 140mm deep 852-07-07 Blank Insert without pockets for local machining. Includes M4 tapped hole for supplied extractor tool. 852-07-07C Custom Insert. Isotech can provide custom drilled pockets, minimum of 3mm separation between holes. Contact Isotech with your requirements.
Blackbody Kit 852-09-05
Includes a Blackbody target and Sensor.
Surface Sensor Kit 852-07-15
Includes angled thermocouple.
Calibration
Includes three point traceable calibration certificate for block temperature
UKAS Calibration
Recommended: Options for block temperature and reference thermometer inputs (simulation). Legally traceable in more than 70 countries.
Air Cooling 853-04-02
Standard Probe 935-14-72/DB
Current Loop Interface 935-06-161
Carrying Case 931-22-111
For use with an air supply this accessory allows air to be blown into the block for rapid cooling.
Platinum Resistance Thermometer for use up to 660°C. Probe diameter 6mm, recommended pocket size 6.5mm.
24VDC Power Supply and Terminal Box. Powers 4-20mA Current Transmitters with 4mm terminal posts for easy connection.
Sturdy case with room for accessories. Features wheels and pull out handle.
Page 4
The world’s leading National Metrology Institutes
0.12°C
0.10°C
0.08°C
0.06°C
0.04°C
0.02°C
0°C 100°C 200°C 300°C 400°C 500°C 600°C 700°C
0°C
Jupiter
Audit Calibration (Similar Sensors)
Radial Homogeneity (difference between holes)
choose Isotech - shouldn’t you?
Isotech manufacture the widest range of temperature calibration equipment from hand held thermometers to Primary Standards. With Isotech solutions you can expand your equipment no matter what the requirement.
Isotech have been pioneering the latest developments in Temperature Metrology for more than 30 years, benefit from our know how, experience and global network.
Jupiter Benefits
n The Jupiter calibration block features
uniform heating with a custom wound heater over an extended length of the block. The block itself is made from copper which has a very high thermal conductivity; much
superior to the aluminium bronze alloys used elsewhere. A propriety process is used to protect the copper from oxidising. This combination of materials and expert knowledge delivers superior performance.
660°C Operation
n The Jupiter ADVANCED operates to
a maximum of 660°C; matched to the upper limit of the high temperature Isotech Semi Standard Platinum Resistance Thermometers. This allows maximum accuracy with no risk to exceeding the temperature limit of the PRT. This gives greater accuracy than extending the range beyond 660°C and having to use an inferior thermometer or thermocouple.
Superior uniformity by using copper
block with extended length heating
g Audit Calibration (Similar Sensors)
g Radial Homogeneity
See Evaluation Reports for full details
http://www.isotech.co.uk
How To Order
1 - Select Desired Options and Accessories 2 - Supply Voltage: Specify either 115Vac 50/60hz or 230Vac 50/60Hz
CALIBRATION SOLUTIONS
27
|
Loading...