Isotech I-Cal Easy Data sheet

93
SOLUTIONS FOR PRIMARY & SECONDARY LABORATORIES
|
Calibration Software
Easy
Fully Automatic Calibration
Design and Print Certificates
Calculate Coefficients
Prints PRT and TC tables
Supports more equipment
Try the full version free for 30 days
Use I-Cal Easy to automate sensor calibration, enter up to 20 calibration points and let the software set the bath, wait for stability and log the data automatically. Choose the stability criteria and how many points to record at each calibration temperature. Automatic temperature calibration the easy way.
I-Cal Easy lets you use a built-in template or design your own certificate. Add text, data fields and graphics on single or multiple pages, then publish the calibration data to the certificate. Do you want to include or calculate coefficients? Then drag your data to the ITS-90 or Calender Van Duesen calculators. For thermocouples use the powerful regression calculator to fit error curves.
I-Cal Easy
Other systems have limited the user with a built-in template and the need to pay extra for any changes, with I-Cal Easy just build in your own certificate in minutes!
I-Cal Easy supports the TTI-7 and
CALISTO 2250S
ISOCAL-6
!
Read Handbook before Use
Not for use in Hazardous Areas
Check Supply Voltage
TTI
Selector
Switch
System Connections
0
A
5
ZERO
1
B
6
TRIG
2
DIFF
7
+1
3
SENS
8
-1
4
UNIT
9
AVE
+/-
RESN
÷2
KYB
MATH
CLE
OPT
OK
CAL
CHG
SCAN
ON
OFF
LINE FAST
TTI-7
TC/RTD THERMOMETER
CU
CU+ CU-
CU
CU+ CU-
TC INPUTS
RTD INPUTS
A0 A0
A: Pt100 R0 = 100.000 A = 138.50 4 WIRE
R = 138.50 Ohm +I BUSY Run
+ 100.000 ∞C
Build an automatic calibration system with I-Cal Easy
The number of sensors that can be calibrated depends upon the equipment used. Calibrate up to 16 sensors with two switch boxes, expandable to 32.
Isotech Dry Blocks, Liquid Baths and Calibration Furnaces. Additional support for other and third party instruments is available, contact Isotech for details.
I-Cal Easy provides a powerful but easy to use automatic calibration system. A graphical setup lets you drag and drop instruments and equipment onto the appropriate PC port - no need to create config files. In addition to the comprehensive manual balloon tips guide you as to the operation of each control. Once familiar with the system this balloon help feature can be turned off.
The criteria for stability can be set to suit all types of equipment; Dry Blocks, Liquid Baths and High Temperature Furnaces. Once the system is stable choose how many measurements to take at each calibration point and have the average value appear on the certificate. Create one or multiple page certificates, as many as required to suit different customers and different types of calibration, Thermocouple, Industrial PRTs and SPRTs. Drag and drop data and text fields onto the certificate, link to logos and other graphic elements.
The in-built calculator will calculate coefficients for both IEC 751, ITS-90
and for thermocouples you can choose what order of regression to fit an error curve. Try the demo version and see how easy it is to drag data to the calculator and export the results straight to a certificate.
Judge for yourself how this compares to any other software. The demonstration version will run without restriction for 30 days and enable you to learn how to use I-Cal Easy and save time by rapidly producing certificates to your own requirements. Try it and see why we are confident that I-Cal Easy is the market leader.
System Requirements
Computer Desktop or Notepad PC
Operating System Windows 98/2000/XP
Display 800 X 600 / 16 bit display
I-Cal - Supported Camera Check with Isotech for supported models
Serial Ports A maximum of three ports are required, one for the dry
(1024 X 768 recommended)
block, one for the TTI and one for the Switchboxes (Two Switchboxes can be operated from a single port)
Note:
Available in different languages ­Spanish and Chinese currently available.
94
SOLUTIONS FOR PRIMARY & SECONDARY LABORATORIES
|
Loading...