The Gemini range of Dry Blocks have high capacity
allowing a large number of probes to be calibrated
together. They are also suitable to accept large diameter
probes with the block volume of a nominal 64 x 160mm.
Whilst the large block takes longer to heat and cool than
the Jupiter it can calibrate thermocouples, resistance
thermometers, thermostats and sensors that are too large
for the smaller blocks.
These award winning calibrators are easy to use and are
available in three versions – the Basic, the Site and the
ADVANCED. The Basic has a digital display of set and
nominal temperature, the Site additionally includes an inbuilt independent temperature indicator for a reference
probe. The ADVANCED controller has inputs for reference
and test thermometers with a further range of sophisticated
features including automatic temperature cycling, secure
data logging and full colour high resolution display.
Gemini
All models include I-Cal Easy LOG software and the
ADVANCED models additionally include software to
manage logged data and configure the unit, see page 14
for more details.
Available with a fixed block with four 8mm and four 19.5mm
pockets or the LRI version which has a removable block.
With the LRI model, blocks can be drilled to custom
configurations.
Isotech is a world leader in temperature calibration,
providing many nations with their Primary Standards and
operates a full scale UKAS accredited calibration
laboratory. We can offer a range of calibration options to
meet your requirements.
Thesemodelsmeetthecalibrationcapacityrequirements
of EURAMET/cg-13/v.01, “EA Guidelines on the Calibration
of Temperature Block Calibrators, formerly EA10/13.
Display Resolution0.01°C from 30.00 to 99.99°C then 0.1°C: 0.01°C Over PC Interface
COMMON Specifications
Display Accuracy
Cools from 550°C to 275°C
from 550°C to 60°C
Heats from 30°C to 550°C
from 50°C to 700°C
Best PerformanceSee Graph
Calibration volume65mm diameter x 160mm deep
Indicator units°C, °F, K
Voltage115Vac or 230Vac 50/60Hz
Power600 Watts (LRI: 1000 Watts)
Dimensions384H (including handle) x 212W x 312D mm
Weight8.5kg14kg
(1) Dry Block Mode only: Comparing 6.5mm Well to Display Value.
1
35 mins (LRI: 132 mins)
345 mins (LRI: 420 mins)
35 mins (LRI: 60 mins)
0.5°C
-
-
-
-
110 mins (LRI: 120 mins)
ADVANCEDSITEBASIC
Digital Display of Set and
Nominal Block Temperature
YesYesYes
PC InterfaceEthernet + USB HostSerialSerial
Test ThermostatsYes - Two InputsYes - Single InputNo
Independent Temperature
Indicator for Reference Probe
YesYesNo
Up to 3: Two universal
Additional Inputs for Units
Under Test
inputs for
Thermocouple or Process
inputs and a further
PRT,
NoNo
Thermocouple input
Automatic Temperature
Cycling
YesNoNo
Data LoggingYes - Export to USBNoNo
Offset Elimination
Choose English, French,
Italian or Spanish Language
Yes - block can follow
reference input
NoNo
Yes - on full colour displayNoNo
In Built Web ServerYesNoNo
Yes - Suitable for life
Tamper Proof Data
science, automotive and
NoNo
aerospace applications
UKAS Calibration available for these systems - International Traceability - Best Practice
CALIBRATION SOLUTIONS
See page 14
29
|
Gemini Accessories
dry Blocks
LARGE VOLUME
Gemini
Fixed Block
Four 8mm Pockets
Four 19.5mm Pockets
Gemini LRI
Removable Block
Eight 8mm Pockets
Can be custom drilled
Metal Block Sleeves
Set of four Sleeves to suit the block.
857-07-03 1 sleeve with 2 holes 4.5mm x
Gemini 700
Note: The use of sleeves will introduce an additional thermal gradient into the block.
This can be avoided by using the LRI model with a block drilled for specific probes.
Removable Inserts
Gemini 550 LRI
976-07-01a Included as Standard
976-07-01b Blank Insert
976-07-01c Custom Insert
Gemini 700 LRI
976-07-02a Included as Standard
976-07-02b Blank Insert
976-07-02c Custom Insert
Gemini 550
Optional single hole sizes 4, 6, 8, 10, 12,
14mm diameter all 150mm deep.
857-07-01 Undrilled sleeves
for local machining.
150mm deep.
Set of four Sleeves to suit the block.
Optional single hole sizes 4, 6, 8, 10, 12,
14mm diameter all 150mm deep.
857-07-02 Blank sleeves
for local machining.
857-07-04 1 sleeve with 2 holes 4.5mm x
150mm deep.
Removable insert with eight 8mm pockets
Insert without pockets for local machining
Contact Isotech with your requirements
Removable block with eight 8mm pockets
Insert without pockets for local machining
Contact Isotech with your requirements
Calibration
UKAS Calibration
Current Loop Interface
Standard Probe
935-14-63 Type N Thermocouple for use
Carrying Case
Includes three point traceable calibration
certificate for block temperature
Recommended: Options for block
temperature and reference thermometer
inputs (simulation). Legally traceable in
more than 70 countries.
935-06-161 24VDC Power Supply and
Terminal Box. Powers 4-20mA Current
Transmitters with 4mm terminal posts for
easy connection.
935-14-72/DB Platinum Resistance
Thermometer for use up to 650°C.
Sturdy case with room for accessories.
Features wheels and pull out handle.
The world’s leading National Metrology Institutes
0.12°C
0.10°C
0.08°C
0.06°C
0.04°C
0.02°C
0°C100°C200°C300°C400°C500°C600°C700°C
0°C
Gemini
Audit Calibration (Similar Sensors)
S model with UKAS option
0.1
0.005
0.001
0.011
Gemini 550
Gemini 550 LRI
0.0035
0.017
0.10.1
Radial Homogeneity
(difference between holes)
choose Isotech - shouldn’t you?
Isotech manufacture the widest range of
temperature calibration equipment from
hand held thermometers to Primary
Standards. With Isotech solutions you
can expand your equipment no matter
what the requirement.
Isotech have been pioneering the
latest developments in Temperature
Metrology for more than 30 years,
benefit from our know how, experience
and global network.
Gemini Benefits
n The Gemini has a large block with
sufficient mass to accommodate
larger sensors or a larger number of
sensors. The fixed block has four
19.5mm pockets and four 8mm
pockets.
n
The LRI model with its removable
block can be custom drilled. Whilst
the larger block takes longer to heat
than the fast response models they
do allow larger probes to be
accommodated and can be used
with custom blocks to simulate
applications, allowing probes that
would otherwise be unsuitable for
Dry Block calibration to be
evaluated.
How To Order
1 - Select Desired Options and Accessories
2 - Supply Voltage:
Specify either 115Vac 50/60hz or 230Vac 50/60Hz