IRIS QP-1800 User Manual

QuietPower 1800 (QP-1800) DC to AC Power Inverter
Model QP-1800 / PN 287A107 (System)
Owner’s Manual Revised 15 OCT 01
Iris Technology Corporation [CAGE 78535] 17175 Von Karman Avenue, Suite 104, Irvine, CA 92614-0904
QuietPower 1800 Inverter Owner’s Manual Rev 15 OCT 01 Page 1
1 IMPORTANT SAFETY INSTRUCTIONS .................................................................. 3
2 INTRODUCTION....................................................................................................... 5
2.1 QuietPower Inverter Key Features ............................................................................................................5
3 INSTALLATION........................................................................................................ 6
3.1 Requirements for Installation.....................................................................................................................6
3.2 Locating the QuietPower Inverter .............................................................................................................6
3.3 Mounting the QuietPower Inverter............................................................................................................7
3.4 Wiring the QuietPower Inverter ................................................................................................................8
4 QUIETPOWER INVERTER OPERATION ................................................................ 8
4.1. Principles of Operation ...............................................................................................................................8
4.2 Output Waveform........................................................................................................................................8
4.3 Control Panel ...............................................................................................................................................9
4.4 QuietPower POWERSAVE Mode............................................................................................................10
4.5 Inverter Operating Limits and Protection Features...............................................................................10
5 TESTING................................................................................................................. 11
6 TROUBLESHOOTING GUIDE ............................................................................... 12
6.1 Fault Conditions and Indicators...............................................................................................................12
7 WARRANTY ........................................................................................................... 13
8 WARRANTY SERVICE........................................................................................... 13
9 BATTERY INFORMATION ..................................................................................... 14
9.1 Battery Type...............................................................................................................................................14
9.2. Battery Size ................................................................................................................................................15
10. PERFORMANCE GRAPHS AND SPECIFICATIONS ............................................ 16
10.1. Power Derating Curve...............................................................................................................................16
10.2. Efficiency Curve.........................................................................................................................................17
11 SYSTEM COMPONENTS....................................................................................... 18
QuietPower 1800 Inverter System............................................................................................................................18
11. APPENDIX A. TECHNICAL ADDENDUM. ............................................................ 20
QuietPower 1800 Inverter Owner’s Manual Rev 15 OCT 01 Page 2
1 Important Safety Instructions
Item Identification
The QuietPower Inverter System, PN 287A107, consists of four (4) items:
· QuietPower Inverter QP-1800 (PN 287A101) [Qty 1]
· QuietPower Inverter NATO SLAVE Cable (PN 287A106) [Qty 1]
· QuietPower Inverter Vibration Isolators (Neoprene, Cylindrical) with mounting hardware [Qty 4]
· QuietPower Inverter Operator’s Manual [Qty 1]
General Safety Precautions
1. Save these instructions. This Owner's Manual contains important safety and operating information for the QuietPower Inverter.
2. The QuietPower Inverter has a Ground Fault Circuit Interrupter (GFCI) and a Circuit Breaker for your safety. These features are critical to the safe operation of this system and must not be disabled.
3. Do not expose the QuietPower Inverter to rain, snow, spray, bilge or dust. To reduce risk of fire hazard, do not cover or obstruct the ventilation openings. Do not install the QuietPower Inverter in a zero-clearance compartment. Overheating may result.
4. Do not use attachments not recommended or sold by Iris Technology. Doing so may result in a risk of fire, electric shock, or injury to persons.
5. The QuietPower Inverter (PN 287A101) is designed to connect to a military vehicle 24 VDC power system through the supplied NATO SLAVE Cable (PN 287A106).
6. To avoid a risk of fire and electric shock, make sure that existing wiring is in good electrical condition. Do not operate the QuietPower Inverter with damaged wiring.
7. Do not operate the QuietPower Inverter if it has received a sharp blow, been dropped, or otherwise damaged in any way. If the QuietPower Inverter has been damaged, please refer to Section
8.0 of this manual: Warranty Service.
8. Do not disassemble the QuietPower Inverter; see the Service section of this manual for instructions on obtaining service for the QuietPower Inverter. Attempting to service the unit yourself may result in a risk of electrical shock or fire.
9. To reduce risk of electrical shock, disconnect the DC power from the QuietPower Inverter before attempting any maintenance or cleaning or working on any equipment and circuits connected to the QuietPower Inverter. Turning off controls will not reduce this risk.
Explosive Gas Precautions
1. This equipment contains components which can produce arcs or sparks. To prevent fire or explosion do not install in compartments containing batteries or flammable materials or in locations which require ignition protected equipment. This includes any space containing gasoline-powered machinery, fuel tanks, or joints, fittings, or other connection between components of the fuel system.
2. Working in the vicinity of a lead-acid battery is dangerous. Batteries generate explosive gases during normal battery operation.
QuietPower 1800 Inverter Owner’s Manual Rev 15 OCT 01 Page 3
3. To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and the manufacturer of the equipment in which the battery is installed.
Precautions When Working With Batteries
1. Someone should be within range of your voice or close enough to come to your aid when you work near a lead-acid battery.
2. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.
3. Wear complete eye protection and clothing protection. Avoid touching eyes while working near batteries.
4. Clean battery terminals before making connections. Wear eye protection to keep corrosion from coming in contact with eyes.
5. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, immediately flood eye with running cold water for at least 20 minutes and get medical attention immediately.
6. NEVER smoke or allow a spark or flame in vicinity of battery or engine.
7. Do not drop a metal tool on the battery. The resulting spark or short-circuit on the battery or other electrical part may cause an explosion.
8. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead-acid battery. A lead-acid battery produces a short-circuit current high enough to weld a ring or the like to metal, causing a severe burn.
FCC INFORMATION
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
· Consult the dealer or an experienced radio/TV technician for help.
Department of the Navy Product Evaluation
This equipment has been tested by SPAWAR (Department of the Navy) for MARCORSYSCOM and is recommended for use in wheeled military vehicles. Contact Iris Technology for details about obtaining a copy of this evaluation (Restricted Distribution, FOUO).
QuietPower 1800 Inverter Owner’s Manual Rev 15 OCT 01 Page 4
2 Introduction
Thank you for your purchase of this QuietPower Inverter. As a high quality, true sine wave output inverter, you can expect the QuietPower to deliver exceptional performance and give you years of dependable operation. The true sine wave AC output from the QuietPower Inverter ensures all AC loads operating from the unit perform efficiently and correctly. Since these loads were designed to operate from true sine wave voltage, you can expect these loads to operate the same as if operating from grid/utility supplied power. In some cases, the true sine wave output from the QuietPower Inverter is even superior to the power supplied by your utility company.
To get the most out of your QuietPower Inverter, please carefully read and follow the instructions in this guide. Pay special attention to the Important Safety Instructions in this guide and to the CAUTION and WARNING statements found throughout the guide and on the product. Please retain all packaging.
Should you have any questions before, during, or after installation, please call Iris Technology's Customer Service Department for help.
Customer Service Toll Free: (866)240-9540 Customer Service Phone: (949)975-8410 Customer Service Fax: (949)975-8498 Customer Service Email: support@iristechnology.org
Please record the following information for use if you need to contact Iris Technology for servicing of the unit.
QuietPower Inverter Serial #: ___________________________
Place of purchase: ___________________________
Date of purchase: ___________________________
Contract reference ___________________________
2.1 QuietPower Inverter Key Features
The QuietPower Inverter utilizes advanced high frequency switching technology in the power conversion process. The circuits are similar to those used in power supplies for computers and other electronic equipment. This technology offers several benefits:
· Light weight: for easy installation
· Totally silent: for quiet operation
· High surge capability: for ‘hard-to-start” AC loads
See Section 10 Specifications, for complete product specifications.
2.1.1. Inverter Function
When connected properly and the power switch is turned to the ‘|’ position, the QuietPower Inverter draws power from a battery and delivers a true sine wave AC output voltage that is similar to the voltage supplied by your local utility. As long as the battery voltage is within the operating range of the unit, the QuietPower will continue to deliver AC power to the loads connected. High and low battery shutdowns will engage if the battery voltage falls out of the specified range of operation (20-32 VDC).
QuietPower 1800 Inverter Owner’s Manual Rev 15 OCT 01 Page 5
2.1.2 Control Panel
The Control Panel provides ‘0/|’(Off/On) control and displays operating information so you can monitor the status of the Inverter and your batteries.
This panel can be removed and re-attached in different orientations so the display information is directed at you in the most convenient fashion, for all recommended mounting configurations.
3 Installation
This section contains instructions for installing the QuietPower Inverter. After securing the unit and making wiring connections, do not turn the unit on.
Proceed to the next section of the manual which provides operating instructions.
3.1 Requirements for Installation
What You Need to Install the QuietPower Inverter
You need the following tools and hardware to properly install the QuietPower Inverter:
· Wrench for DC terminals (½” or 13 mm)
· Wrench for Vibration Isolators (optional use)
· DC cables (supplied as PN 287A106)
3.2 Locating the QuietPower Inverter
The QuietPower Inverter utilizes complex electronic circuits and although design precautions have been made for protection of these circuits, they can be susceptible to damage from use in extreme environments. The QuietPower Inverter should only be installed in a location that meets the following requirements:
· Dry: do not allow water or other fluids to drip or splash on the QuietPower Inverter. Do not mount the QuietPower Inverter in an area subject to splashing or dripping water or bilge.
· Cool: normal ambient air temperature should be between 0°C (32°F) and 25°C (77°F) - the cooler the better within this range. Refer to the operating temperature information in the specifications section of this manual.
· Ventilated: allow at least 5 inches (13 cm) of clearance all around the unit. Ensure that the ventilation openings on the unit are not obstructed. If mounting in a compartment, ventilate with louvers or cut­outs.
· Safe: do not install the QuietPower Inverter in the same compartment as batteries or in any compartment capable of storing flammable liquids such as gasoline. Do not install the QuietPower Inverter in an engine compartment or other location where ignition protected equipment is required.
· Dust-free: do not install the QuietPower Inverter in a dusty environment where either dust, wood particles or other filings/shavings are present. These can be pulled into the unit when the cooling fan is operating.
· Close to AC junction box: avoid the use of extended wire lengths if possible.
· Close to battery/batteries: Avoid excessive cable lengths but do not install the QuietPower Inverter in
the same compartment as batteries. Use the recommended wire lengths and sizes (see section
3.4.4). Also do not mount the QuietPower Inverter where it will be exposed to the gases produced by the battery. These gases are very corrosive and prolonged exposure will damage the QuietPower Inverter.
· Protected from battery acid: Never allow battery acid to drip on the QuietPower Inverter or its wiring when reading specific gravity or filling the battery.
QuietPower 1800 Inverter Owner’s Manual Rev 15 OCT 01 Page 6
3.3 Mounting the QuietPower Inverter
Before mounting the QuietPower Inverter, test the chosen location for adequate space around the unit to allow for connections and ventilation. Mounting hardware should be corrosion resistant and ¼” or 6 mm diameter screws. Your mounting system should be able to support three times the weight of the QuietPower Inverter, which weighs approximately 16 pounds (7.3Kg). The more clearance for ventilation around the unit, the better the performance. At a minimum, have 5” of free space on all sides of the inverter. For your convenience, four (4) Neoprene Cylindrical Sandwich Mount Vibration Isolators and attachment hardware are provided for shock mounting.
To mount the QuietPower Inverter
Mount the QuietPower Inverter on either a horizontal or vertical surface (such as a bulkhead) using the mounting holes provided. For secure, permanent mounting, use all eight mounting holes. Optionally, use four shock mounts provided. To meet regulatory requirements, the QuietPower Inverter must be mounted in one of the three orientations shown in Figure 1 below.
Remove and re-attach the front panel depending on the orientation of the base unit itself. For example, if the unit is mounted on a vertical surface, you may want to remove the panel and attach it so it is again readable horizontally. This can be done as depicted in Figure 2, below, by removing the 4 screws, taking the panel out of the housing, rotating the panel and reattaching the panel to the base unit. Be sure to re­install all four screws.
Figure 1. Approved Orientations for
Inverter Mounting.
QuietPower 1800 Inverter Owner’s Manual Rev 15 OCT 01 Page 7