To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area free of conductive contaminants. (See the specifications for the
acceptable temperature and humidity range.)
To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid
exposing the unit to direct sunlight or installing the unit near heat emitting appliances such
as space heaters or furnaces.
Do not attach non-computer-related items, such as medical equipment, life-support
equipment, microwave ovens, or vacuum cleaners to UPS.
Do not plug the UPS input into its own output.
Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any
other liquid-containing vessels on or near the unit.
In the event of an emergency, press the OFF button and disconnect the power cord from
the AC power supply to properly disable the UPS.
Do not attach a power strip or surge suppressor to the UPS.
For 600/800/1000 model, the input power should be limited with circuit breaker.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS - This manual contains important safety instructions. Please read and
follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly
before attempting to unpack, install, or operate your UPS.
1

Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
Servicing of batteries should be performed or supervised by personnel knowledgeable of
batteries and the required precautions. Keep unauthorized personnel away from batteries.
The battery supply should be therefore disconnected in the plus and minus pole at the
quick connectors of the battery when maintenance or service work inside the UPS
is necessary.
Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery.
When replacing the batteries, use the same number and type of batteries.
Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the
battery or batteries. Released electrolyte is harmful to the skin and eyes.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS - This manual contains important safety instructions. Please read and
follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly
before attempting to unpack, install, or operate your UPS.
2

The UPS provides automatic voltage regulation for inconsistent utility power, and provides battery
backup during power outages, and ensures consistent power to your computer system.
OVERVIEW
Your new UPS may be used immediately upon receipt. However, recharging the battery for at least
8 hours is recommended to ensure that the battery's maximum charge capacity is achieved. Charge
loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged
into an AC outlet. The unit will charge in both the on and off position.
With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered
data storage device (Zip drive, Jazz drive, Tape drive, etc. into the battery power supplied outlets. DO
NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device
into the battery power supplied outlets. The power demands of these devices will overload and
possibly damage the unit.
Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet
is protected by a fuse or circuit breaker and does not service equipment with large electrical demands
(e.g. air conditioner, refrigerator, copier, etc. Avoid using extension cords.
Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit
will "beep".
If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct
this, turn the UPS off and unplug at least one piece of equipment from the battery power supplied
outlets. Wait 10 seconds. Make sure the circuit breaker / fuse is normal and then turns the UPS on.
To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge
the battery every three months to ensure battery life.
HARDWARE INSTALLATION GUIDE
INSTALLING YOUR UPS SYSTEM
3

This port allows connection and
communication from the USB port on the
computer to the UPS unit.
RJ45/11 COMMUNICATION
PROTECTION PORTS
Communication protection ports will protect
any standard modem, fax, telephone line, or
network cable
The circuit breaker provides optimal overload
protection.
Connect to utility power.
BATTERY BACKUP & SURGE
PROTECTED OUTLETS
Provide battery backup and surge protection.
They ensure power is provided to connected
equipment over a period of time during a
power failure.
FRONT PANEL
The LCD will display the UPS status including
input voltage, output voltage, percentage of
load and battery…etc.
The LCD will display the UPS status including
input voltage, output voltage, percentage of
load and battery…etc.
This LED is illuminated when the UPS is
working.
4

RJ45/11 Communication Protection
Dimensions (W x H x D)(mm)
Model
INPUT
Voltage Range 162~280Vac
On Battery Output Voltage Simulated Sine Wave at 230Vac +/-5%
On Battery Output Frequency 50 Hz +/-1%
BATTERY
Sealed Maintenance Free L
Battery
Indicators Power On / Using Battery
Audible Alarms On Battery, Low Battery, Overload, Fault
Operating Relative Humidity 0 to 90%
MANAGEMENT
USB COMM. Port Included
Ports
5

DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD INDICATION
Sound disable
3s to disable and
enable the buzzer
sound)
Bat mode:
battery capacity
1. Battery charging:
cycle lighting
2. Battery full charged:
lighting
3. Line mode without
charger: battery
capacity
6

DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LINE MODE & BATT. MODE
Initial
OUTPUT
7

Batteries are not fully charged.
Battery is slightly worn out.
perform e
The on/off switch is designed
to pr
The unit is not connected to an
AC outlet.
The unit must be connected to a 120Vac
50/60Hz outlet.
Contact Technical Support.
Contact Technical Support.
Turn the UPS off. Wait 10 seconds and then
The UPS will not
turn on.
Allow the unit to recharge for at least 4
hours.
Unit has been damaged by a
surge or spike.
Contact Technical Support.
All rights reserved. Reproduction without permission is prohibited.
ossible Cause SolutionProblem
Recharge the battery by leaving the UPS
Contact Technical Support.
Outlets do not
provide power to
event damage by rapidly
ker is tripped due
overload.
turn the UPS on.
Turn the UPS off and unplug at least one
piece connected equipment. Unplug the
power cord of the UPS then press the circuit
breaker knob.
ION F11 800 Power Guide software is available on our website.