MobileLAN™access 2102 Mounting Kit for EasyCoder Printers – Installation Instructions
Chapter 1
Description
The MobileLAN™access 2102 Mounting Kit is an optional
device that makes it possible to fi t and connect an Intermec
MobileLAN
™
access 2102 device to any EasyCoder printer that
is already fi tted with an EasyLAN 10i or 100i interface board.
MobileLAN™access 2102
The kit consists of
• one metal bracket for EasyLAN 10i-equipped printers
(EasyCoder 3240, 3400, 3440, 3600, 4420, and 4440)
• one metal bracket for EasyLAN 100i-equipped printers
(EasyCoder F2, F4, 501 XP, and 601 XP)
• one RJ-45 to RJ-45 communication cable
• two screws
• a Torx driver
• this installation instruction booklet
The MobileLAN
™
access 2102 mounting bracket (plastic) is
packed with the MobileLAN
™
access 2102 device.
For instructions on how to confi gure, connect, and use the
MobileLAN
™
access 2102 device, refer to the MobileLAN™access
21XX System Manual (P/N 067150) pu blished by Intermec in
U.S.A.
Refer to the manuals that came with the EasyLAN 10i or 100i
interface board for information on how to install and use the
EasyLAN interface
.
Application of Use
Installation Kit
Manuals

MobileLAN
™
access 2102 Mounting Kit for EasyCoder Printers – Installation Instructions
2
Chapter 2
1 2 3 4 5 6 7 8
Power
Network
T
est
EasyLAN 10i Interface Board
• Remove the two Phillips screws that hold the cover plate of
the EasyLAN 10i interface board.
• Fit the correct type of metal bracket (see illustration) to the
cover plate using the same screws.
• Using the two #T10 Torx screws included in the kit, attach
the MobileLAN
™
access 2102 mounting bracket (plastic) to
the metal bracket.
Fitting the Brackets
#T10 T orx screws
(2 places)
Installation
Metal Bracket
EasyLAN 10i Board
MobileLAN™access 2102
Mounting Bracket
RJ-45 Connector
Phillips screws
(2 places)
The illustrations shows an EasyCoder
3400 printer . Howe ver, the same principles apply to EasyCoder 3240, 3440,
3600, 4420, and 4440.

3
MobileLAN™access 2102 Mounting Kit for EasyCoder Printers – Installation Instructions
Chapter 2 Installation
EasyLAN 100i Interface Board
• Remove the two #T10 Torx screws that hold the cover plate
of the EasyLAN 100i interface board.
• Fit the correct type of metal bracket (see illustration) to the
cover plate using the same screws.
• Using the two #T10 Torx screws included in the kit, attach
the MobileLAN
™
access 2102 mounting bracket (plastic) to
the metal bracket.
Fitting the Brackets,
cont.
#T10 T orx screws
(4 places)
The illustrations shows an EasyCoder
F-series printer. However, the same
principles apply to EasyCoder XPseries printers.
Metal Bracket
EasyLAN 100i Board
RJ-45 Connector
MobileLAN™access 2102
Mounting Bracket

MobileLAN
™
access 2102 Mounting Kit for EasyCoder Printers – Installation Instructions
4
Chapter 2 Installation
• Fit the slots on the back of the MobileLAN™access 2102
device over the hooks on the mounting bracket. Slide the
MobileLAN
™
access 2102 up slightly and the press the base
until it clicks into the clip at the bottom of the mounting
bracket.
• Using the RJ-45/RJ-45 cable included in the kit, connect the
MobileLAN
™
access 2102 and the EasyLAN 10i or 100i inter-
face board installed in the printer .
• Connect the MobileLAN
™
access 2102 to power using the
transformer/cable included in the kit.
Fitting the
MobileLAN™access
2102
Clip
Slots
Hooks
Mounting Bracket
MobileLAN™access 2102
MobileLAN™access 2102
RJ-45/RJ-45 Cable
Power to
MobileLAN™access
2102

5
MobileLAN™access 2102 Mounting Kit for EasyCoder Printers – Installation Instructions
Chapter 3
Setting Up the Connection
General Description
The MobileLAN™access 2102 uses an IEEE 802.11B master/
slave connection.
The master is a MobileLAN™access 21XX connected to an Ethernet network via a cable.
The slave is the MobileLAN™access 2102 fi tted on the printer
and connected to the printer’s EasyLAN 10i or 100i interface
board via a cable. The master and slave communicate via
radio.
Set up the master fi rst and then the slave using a Web browser
as described below.
Start a Web browser on a PC connected to a network:
Log in as “intermec”. Default password is “intermec.”
Master
It is important that you start by setting
up the Master and continue by setting
up the Slave!

MobileLAN
™
access 2102 Mounting Kit for EasyCoder Printers – Installation Instructions
6
Chapter 3 Setting Up the Connection
Master , cont.
Set “Node” type to <Master>.
Set “Wireless Hops” to <Enabled>.
The “Spanning Tree Settings/Global Flooding” should no w be
as follows:

7
MobileLAN™access 2102 Mounting Kit for EasyCoder Printers – Installation Instructions
Chapter 3 Setting Up the Connection
Master , cont.
Select the “Save/Discard Changes” option.
Click on “Save Changes and Reboot.”
Note that this document only describes the steps necessary to
set up a wireless access point to connect with a printer. Other
parameters may need to be set in the access point to conform
to the network. Refer to the MobileLAN access 21XX System
Manual (P/N 067150) for further information.

MobileLAN
™
access 2102 Mounting Kit for EasyCoder Printers – Installation Instructions
8
Chapter 3 Setting Up the Connection
Slave
Use a Web browser to set up the slave, that is, the
MobileLAN
™
access 2102 connected to your printer.
Log in as “intermec”. Default password is “intermec.”
Set the “Node type” to <Station>. Note that after changing
this parameter, the M obileLAN
™
access 2102 will not be able to
relay radio communications to other slaves.

9
MobileLAN™access 2102 Mounting Kit for EasyCoder Printers – Installation Instructions
Chapter 3 Setting Up the Connection
Slave, cont.
Go to the “Spanning Tree Settings” and set the “Secondary
LAN Bridge Priority” to 1, “Root priority” to 0, and “Second-
ary LAN Flooding” to Enabled.
Also refer to the MobileLAN access 21XX System Manual (P/N
067150) for further information.
Master
Wireless Hops Enabled
Root Priority 0
Multicast Flood Mode Universal
Slave
Node type Station
Root Priority 0
Secondary LAN Bridge Priority 1
Secondary LAN Flooding Enabled
Setup Summary

MobileLAN
™
access 2102 Mounting Kit for EasyCoder Printers – Installation Instructions
10
Notes

Intermec Printer AB
Idrottsvägen 10, P.O. Box 123
S-431 22 Mölndal, Sweden
tel +46 31 869500
fax +46 31 869595
www.intermec.com
*1-960547-02*
MobileLAN™ access 2102 Mounting Kit for EasyCoder Printers, Installation Instructions
*1-960547-02*