
Intermec® Corporation
6001 36th Avenue West
P.O. Box 4280
Everett, WA 98203-9280
U.S. technical and service support: 1-800-755-5505
U.S. media supplies ordering information: 1-800-227-9947
Canadian technical and service support: 1-800-688-7043
Canadian media supplies ordering information: 1-800-268-6936
Outside U.S. and Canada: Contact your local Intermec service
supplier.
The information contained herein is proprietary and is provided
solely for the purpose of allowing customers to operate and/or
service Intermec manufactured equipment and is not to be released,
reproduced, or used for any other purpose without written
permission of Intermec.
Information and specifications in this manual are subject to change
without notice.
© 1995 by Intermec Corporation
All Rights Reserved
The word Intermec, the Intermec logo, and Virtual Wedge are
trademarks of Intermec Corporation.
Throughout this manual, trademarked names may be used. Rather
than put a trademark (™) symbol in every occurrence of a
trademarked name, we state that we are using the names only in an
editorial fashion, and to the benefit of the trademark owner, with
no intention of infringement.

Decision Data Series
This Wedge Interface (WIF) Guide lists the cables, power supply,
and keyboard mapping tables for your workstation, and describes
how to configure the reader for your workstation and keyboard.
Decision Data Series
Wedge Interface Guide
This guide covers these workstations:
Decision Data 3596 HP 700/32
Decision Data 3597 HP 700/43
Decision Data 3697 HP 700/44
Decision Data 3776 HP 700/60
Decision Data 3777 HP 700/92
HP 700/94
HP 700/96
HP 700/98
Cables
Use the two cables supplied with this WIF kit to connect the
reader to your workstation and keyboard, as shown in your
Wedge Reader User’s Manual. To order a replacement cable, use
these part numbers:
• Wedge interface kit - Part No. 054287
• Keyboard cable - Part No. 054286
• Terminal cable - Part No. 054285
3

Wedge Interface Guide
Power Supply
The reader might require external power, depending on the
type of workstation you use:
Workstation Power supply and jumper setting
Decision Data 3776
Decision Data 3777
Decision Data 3697
HP 700/43
HP 700/92
HP 700/94
HP 700/96
The reader does not require an external power
supply to work with these workstations. Set the
PCB jumper to connect pins 1 and 2 on the
reader’s rear panel.
Workstation Power supply and jumper setting
Decision Data 3596
Decision Data 3597
HP 700/32
HP 700/44
HP 700/60
HP 700/98
The reader requires an external power supply to
work with these workstations. Set the PCB
jumper to connect pins 2 and 3 on the reader’s
rear panel.
Note: If you use an external power supply for the reader, you must
plug in the power supply before switching on the workstation. If you
do not, the reader will lock up.
4

Decision Data Series
Decision Data 3596, 3597, 3697
Decision Data 3596, 3597, 3697
Decision Data 3596, 3597, 3697
Configuring the Reader
Scan the appropriate label below to configure the reader for
your workstation. The reader should emit one low beep
followed by four low beeps, indicating that the reader has
successfully stored the configuration and is ready to read labels.
If the reader emits a different beep sequence, refer to the Wedge
Reader User’s Manual, Section 2, for beeper identification.
To set workstation
configuration to: Scan this label:
*$+TA173*
*$+TA173*
*$+TA222*
*$+TA222*
*$+TA172*
*$+TA172*
*$+TA460*
*$+TA460*
*$+TA461*
*$+TA461*
5