Intermatic T10404R User Manual

Page 1
TIME SWITCH OPERATING INSTRUCTIONS
1. TO SET “ON” AND “OFF” TIMES: Hold TRIPPERS
against edge of CLOCK-DIAL, point­ing to time (AM or PM) when ON and OFF operations are desired. Tighten tripper screws firmly.
2. TO SET TIME-OF-DAY: Pull CLOCK-DIAL outward. Turn in
either direction and align the exact time-of-day on the CLOCK-DIAL (the time now, when switch is being put into operation) to the POINTER.
DO NOT MOVE POINTER
• TO OPERATE SWITCH MANUALLY: Move MANUAL LEVER below CLOCK-DIAL left or right as indicated by arrows, This will not affect next operation.
• FORMORETHANONEDAILYON-OFF
OPERATION: Place additional tripper pairs on CLOCK­DIAL (order 156T1978A).
• INCASEOFPOWERFAILURE, reset CLOCK-DIAL to proper time-of-day. See step 2 above.
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
158TP10864
CLOCK DIAL
TIME POINTER
OFF TRIPPER
MANUAL LEVER
ON TRIPPER
TIME SWITCH RATINGS:
DOUBLEPOLESINGLETHROW(DPST)
30 AMP, RESISTIVE, INDUCTIVE, TUNGSTEN OR 1000 VA PILOT DUTY - 120/208/240 VAC 2 HP (24 FLA)-120 VAC, 5 HP (28 FLA)-240 VAC
CLOCKMOTOR:208/277VOLTS-60HZ.
(TO ORDER CLOCK MOTOR REPLACEMENT,SPECIFY PART NO. WG--ON MOTOR COVER)
MODEL: T10404R
IN RAINPROOF (TYPE 3R) ENCLOSURE FOR INDOOR OUTDOOR USE
SUITABLE FOR SWIMMING POOL / SPA APPLICATIONS AND FOR DIRECT CONNECTION OF UNDERWATER LIGHTS.
92 AMP PER LEG, 168 AMP MAX., 120/240 VOLT OR 120/208 VOLT SINGLE PHASE, (THREE WIRE) AC.
IMPORTANT: This Control Panel must be installed according to the National Electrical Code (including Article 680)
or Canadian Electrical Code (including Section 68) and Local Electrical Codes. This installation is subject to the approval by the local inspection authority. USE COPPER CONDUCTORS ONLY. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors. If heater protection is required, install FIREMAN SWITCH kit (156T4042A may be ordered). For grounding of the installation, refer to Article 250 and 680 of the National Electrical Code. (For Canadian Installations: Section 10 and 68 of the Canadian Electrical Code). Install only APPROVED wiring device(s) inside the enclosure. An APPROVED wiring device may be installed in the rectangular side knockout provided. When panel is outdoors, an APPROVED rainproof cover must be installed over the wiring device in the side knockout. If this enclosure is used for direct connection of underwater lights, refer to 1999 NEC 680­21(b), 2002 NEC 680-24(b) or CEC 68-060, 062 and 066 for further details. This Control should not be connected to any equipment which would cause bodily injury or property damage should it be activated unexpectedly. After wiring, install front panel over wiring compartment. KEEP DOOR CLOSED AT ALL TIMES.
NOTES:
1. Any Intermatic T100M or ET100CM series Time Switch, P1353ME 3 Circuit Control, PF1000M Series Freeze Protection or RC2000M Series Air Switch Mechanism may be installed in the bracket provided or in the event an existing mechanism is replaced.
2. If this control panel requires bonding, attach an APPROVED bonding terminal of a suitable size using the mounting hole(s) provided on the bottom of the enclosure (156T11047A may be ordered).
3. Wiring devices may be installed in this control panel (order 21T156A (4) Standoffs for mounting).
CONTROL PANEL WITH TWO TIME SWITCHES
LR3730
UL508 UL1563 NEC680
WIRING DIAGRAM AND INSTRUCTIONS FOR INTERCONNECTING TIME
SWITCHESWHENUSEDASSWIMMINGPOOLEQUIPMENTCONTROL
1. Disconnect the clock motor leads of the CLEANER CONTROL TIMER.
2. Connect 240 volt supply and the clock motor leads of the CLEANER CONTROL TIMER to terminals #1 and #3 of the FILTER TIMER.
3. Connect terminals #2 and #4 of Filter Timer to terminals #1 and #3 of the Cleaner Control Timer (using short jumpers).
4. Connect 240 volt load of cleaner pump to terminals #2 and #4 of CLEANER CONTROL TIMER.
CLOCK MOTOR
CLOCK MOTOR
SUPPLY
TO FILTER
PUMP
TO POOL CLEANER
FILTER TIMER
CLEANER CONTROL TIMER
WIRING INFORMATION - COPPER CONDUCTORS ONLY
GENERAL
GENERAL PURPOSE PURPOSE BRANCH BRANCH CIRCUIT WIRE SIZE CIRCUIT MAXIMUM 75˚C MIN TERMINAL BREAKER CURRENT INSULATION TORQUE 120V. 240V. RATING CAPACITY
AWG LB-IN HP HP AMP AMP
14 20 1/2 1 15 12 12 20 1 2 20 16 10 20 1 1/2 3 30 24 8 25 2 5 40 32