Transition Series
Multi-technology Access Readers

Description

Transition™ 500-PIV Series multi-technology card readers feature simultaneous compatibility with multi­vendor 125 kHz Proximity and PIV (ISO 14443A) credential technologies—all in one reader. With this remarkable technology combination, security administrators can now deploy the Transition readers into new or existing facilities.
Figure 1. Multi-technology Readers

Mounting the reader

All models of the T-500-PIV series readers can be mounted using a U.S. single-gang electrical box or directly to a wall.
1. Find a suitable mounting position on the door frame or wall.
Note: For out of doors or wet locations, it is recommended that the gasket provided be installed on the base as shown in Figure 5.
2. If mounting directly to the wall, use one of the following methods:
2a. Drill two vertical mounting holes from 3.25”
(83 cm) to 4.891” (125 cm) apart on the mounting surface of the door frame or wall.
Figure 2. Direct wall mounting
2b. Models 520/525-PIV can be mounted using a
second pair of vertical mounting holes, horizontally spaced 2.75” (70 cm) from the first pair.
Figure 3. T520/525-PIV Direct wall mounting alternative
3. Drill one 0.625” (15.87 mm) diameter hole in wall for the pigtail wire connection.
4. Follow the Cable Connection Chart to connect the reader to the field panel and external door equipment.
5. Mount the base plate to the wall using the supplied screws.
6. Install gasket if required, see Figure 5.
7. Install the top cover to the reader base. The base plate and top cover guides should be aligned, so the connectors seat correctly.
Figure 4. Aligning base plate and top cover
8. Verify the connection is secure and install the security screws on the top and bottom of the reader.
9. Cover the exposed screws with the rubber plugs provided.
Figure 5. Gasket detail

Connecting the cable

1. The readers are supplied with a 12-conductor cable pigtail with drain wire. Connect the pigtail to the host panel. Use the Cable Connection Chart (below) to correctly match the color of each wire.
Color Signal
Red 6 to 16 VDC
Black Ground
Green Data 0
White Data 1
Orange Green LED Control
Brown Red LED Control
Yellow Beeper Control
Gray Door DI
Pink REX DI
Tan Tamper Output
Blue Hold
Purple Reserved
........ Drain Wire
2. Use a DC Power source between 6-16 VDC.
3. Verify the reader is properly grounded by attaching the ground wire to an earth ground connection at the power supply or field panel end of the cable. Connect reader’s drain wire to the cable shield. Connect shield wires at the field panel.

Testing the reader

1. Power up the reader. Verify the power-on self test LED/beep sequence:
- green LED flashes; two short beeps
- yellow LED flashes; three short beeps
- red LED flashes.
- yellow LED flashes.
2. Verify the yellow LED is on continously indicating the reader is ready.
3. Present a badge that has been properly enrolled in the system. Verify the yellow LED flashes and a short beep is heard.

Removing the cover

1. Remove all security screws.
2. Pull cover off the base. Refer to Figure 4 on page 2.

Keypad configuration card

1. Place the reader in tamper mode by briefly removing and replacing the reader’s cover while the power is on. The reader stays in tamper mode for 60 seconds (minimum) after power is applied or the cover is replaced.
2. Present the keypad configuration card within one minute. The LED turns green and a short triple-beep indicates the reader is ready to configure.
3. Enter the keypad entry within five seconds. Use the chart below to identify the correct keypad entry.
non-
Mode/Keypad entry Setting UTC
1 * followed by 0
(Factory default setting)
2 * followed by 1 6 bits per key,
3 # followed by
3 keys (0 to 9 only)
4 1 followed by 1
key (0 to 9 only)
5 1 followed by * 4 bits per key, no parity,
6 1 followed by # 4 bits per key, no parity,
For non-ITC keypad configurations, contact Sales Engineering/Pre-Sales Support for assistance.
8 bits per key, no buffering
no buffering
26-bits output custom configuration. (Contact Sales Engineering/Pre­Sales Support for assistance)
4 bits per key, no parity, up to 9 keys buffered
up to 10 keys buffered
up to 11 keys buffered
UTC


FCC compliance

The FCC requires the following statement: This reader uses radio frequency energy and has been tested, and complies with the limits of FCC testing. Changes, modification, or disregard of proper installation and instructions not expressly approved by UTC Fire & Security, and is strictly prohibited by the FCC and could void the user’s authority to operate the equipment.

Specifications

Colors Black
Power supply Linear DC recommended
Power usage T-500-PIV: 210 mA @ 12 VDC
T-520-PIV: 130 mA @ 12 VDC T-525-PIV: 130 mA @ 12 VDC
Voltage range 6 —16 VDC
Temperature
a
range
Cable distance to panel
Read Range
(Distances may vary depending on environment.)
Wiegand output Proximity 4002 (40-bit)
Tamper output Open Collector
Regulatory approvals and standards
ISO Standards ISO 14443A, B
UL evaluation for UL Listed Installations:
a. -25 b. Model T-500-PIV, T-520-PIV and T-525-PIV Proximity and HID Proximity up to 4.5" (11.43 cm) c. Power consumption:
d. Request to exit terminals on the reader are not to be connected in UL listed installations.
b
o
F to 125oF (-32oC to 52oC)
Model 500-PIV: 210 mA @ 12 VDC Model 520-PIV and 525-PIV: 130 mA @ 12 VDC
-31oF to +149oF (-35oC to +65oC)
Up to 500 ft. (152.4 m) @ 12 VDC with 20 AWG shielded cable
Proximity Perfect and Ultralight cards are not supported by the Transition Series reader. Model T-500-PIV:
- Proximity: up to 3.5" (8.89 cm)
- HID Proximity: up to 3.5" (8.89 cm)
- PIV: up to 1" (2.54 cm) Model T-520-PIV and T-525-PIV:
- Proximity: up to 5" (15.24 cm)
- HID Proximity: up to 5" (15.24 cm)
- PIV: up to 1" (2.54 cm)
HID Proximity (depends on card format) PIV (75-bit and 200-bit)
UL 294, CE, and FCC (part 15)
The voltage specification for this reader is 6—16 VDC, although 12 VDC or greater is recommended for better performance and cable run distances.

Ordering information

Product Part Number
T-500-PIV (Black; Mullion mount; Wiegand output) *
T-520-PIV (Black; 1-Gang US mount; Wiegand output) *
T-525-PIV (Black; 1-Gang US mount; Keypad; Wiegand output) *
* Installation wrench (Required) 385001001
Copyright © 2012, UTC Fire & Security. All Rights Reserved.