Interlogix T-200 User Manual

TruPortal™ Series
front view
side
view
1.75
[44.5mm]
1.0
[25.4mm]
4.20
[106.7mm]
T-200 Model Reader (en-US)
Technical support
For assistance with this product, refer to this document and any other documentation provided. If you still have questions, you may contact technical support during normal business hours (Monday through Friday, excluding holidays, between 8 a.m. and 8 p.m. Eastern Standard Time.) See http://www.interlogix.com/customer-support.
U.S. 1-855-286-8889, option 2 Canada 1-855-286-8889, option 2 Latin America 1-561-998-6114
Web site: http://www.interlogix.com
© 25JUL13, United Technologies Corporation
Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved.
Interlogix 3211 Progress Drive, Lincolnton, NC 28092, USA

Description

The T-200 card reader is a card serial number reader compatible with the following 13.56 mHz technologies:
Vicinity (ISO 15693) HID iCLASS® Serial Number
®
Infineon my-d
Philips I-Code Serial Number
Proximity (ISO14443) DESFire
MIFARE
Serial Number
®
Serial Number
®
Serial Number

Mounting the reader

1. Find a suitable mounting position on the door frame or wall.
2. Drill two vertical mounting holes 2.25” (57.2 mm) apart on the mounting surface of the door frame or wall.
Figure 1. Dimensions
3. Drill one 1.00” (25.4 mm) diameter hole in wall for the pigtail wire connection.
4. Follow the Cable Connection Chart to connect the reader to the field panel and external door equipment.
5. Mount the base plate to the wall using the supplied screws.
6. Hook the top of the reader case to the top of the base plate and press into place.
Figure 2. Aligning top cover, reader case, and base plate.
7. Install the supplied screw in the base of the reader.
8. Snap the cover on the top of the case.

Connecting the cable

1. The readers are supplied with an 8-conductor cable pigtail with drain wire. Connect the pigtail to the host panel. Use the Cable Connection Chart (below) to correctly match the color of each wire.
Color Signal
Black Ground
Blue Beeper
Brown Red LED Control
Green Data 0
Orange Green LED Control
Red 5 to 16 VDC
White Data 1
Drain Shield Ground
2. Use a DC power source between 5-16 VDC.
3. Connect reader’s drain wire to the cable shield. Connect shield wires at the field panel.

Testing the reader

Cable Distance Max. @ 12 VDC AWG
200 ft. (60.96 m) 22
300 ft. (91.44 m) 20
500 ft. (152.4 m) 18
1. Power up the reader. Verify the power-on self test LED/beep sequence:
- green LED flashes; two short beeps
- yellow LED flashes; three short beeps
- red LED flashes
- yellow LED flashes
2. Verify the yellow LED is on continuously indicating the reader is ready.
3. Present a badge that has been properly enrolled in the system. Verify the green LED lights and a short beep is heard.

Removing the cover

To remove the cover, squeeze the sides of the top cover and pull to release the cover.
The voltage specification for this reader is 5-16 VDC, although 12 VDC or greater is recommended for better performance and cable run distances.
The recommended cable gauge is 18-gauge to 22­gauge. Check with the cable supplier to determine the best choice for the application and installation distance.

FCC compliance

The FCC requires the following statement: This reader uses radio frequency energy, has been tested, and complies with the limits of FCC testing. Changes, modifications, or disregard of proper installation and instructions not expressly approved by UTC Fire & Security are strictly prohibited by the FCC and could void the user’s authority to operate the equipment.

Specifications

Colors Black, Charcoal, Gray
Power supply Linear DC recommended
Power usage 50 mA @ 12 VDC
Voltage range 5 - 16 VDC
Temperature
a
range
Cable distance to
b
panel
Read Range
(Distances may vary depending on environment.)
Wiegand output - Mifare 4002 (40-bit)
Regulatory approvals and standards
ISO Standards Mifare ISO 14443A
UL evaluation for UL Listed Installations:
a. -25°F to 125°F (32°C to 52°C) b. 500 ft. (152.4 m) max. 22 AWG @ 12 VDC
c. Vicinity: up to 3.0" (7.62 cm)
c
200 ft. (60.96 m) max. 22 AWG @ 5 VDC
-31°F to 149°F (-35°C to 65°C)
- Mifare: up to 1.0" (2.54 cm) Ultralight cards not supported
- Vicinity: up to 3.5" (8.89 cm)
- Vicinity 5502 (55-bit)
UL 294, CE, and FCC (part 15)
Vicinity ISO 15693

Ordering information

Product Part numbers
T-200 (3 covers, 18" / 45.7 cm pigtail wire)
T-200 (3 covers, 84" / 214 cm pigtail wire)
Note: Each part number includes all three colors of the cover plates (black, charcoal, gray).
© 25JUL13, United Technologies Corporation
Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved.
The TruPortal product name and logo are trademarks of United Technologies. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
TP-RDR-200a
TP-RDR-200b
Document number: 460950002C - July 2013