Interlogix POC252-1CXP-1T User Manual

POC252 Series User's Manual
P/N 1073047 • REV A • ISS 27AUG15
Copyright
© Interlogix is part of UTC Building & Industrial Systems,
Technologies Corporation.
Trademarks and patents
Th Other trade names used in this document may be trademarks or registered
trademarks of the manufacturers or vendors of the respective products.
Manufacturer
Interlogix 3211 Progress Drive, Lincolnton, NC 28092 USA
Authorized UTC Climate Controls & Security B.V., Kelvinstraat 7, 6003 DH Weert, Netherlands
Intended use
Use this product onl y for the purpose i t was designed for; r e fer to the data sheet and user doc your local supplier or visit us online at www.interlogix.com.
Certification
FCC compliance
This equipment has been tested and found to comply with the limits for a Class A di designed to provide reasonable pr ot ec t ion against harmful interferen ce w hen the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fr and used in accordance with the instruction manual, may cause harmful interference to radio communications.
You are cautioned tha t any changes or modifications not ex pr es sl y approved by the party responsible for compl ia the equipment.
ACMA compliance
Notice! This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate measures.
Canada
This Class A digital apparatus complies with Canadian ICES Cet appareil numérique de la classe A est conforme á la norme NMB
Canada.
European Union directives
2004/108/EC (EMC Di rectiv e):
UTC Building & Industri al Syst ems, Inc.
de other relevant provisions of Directive 2004/108/EC.
Contact Information
For contact information, see
www.utcfssecurityproducts.eu
2015 United Technol og i es Corpor at ion
All rights reserved.
e POC252 name and logo are trademarks of Unite d Tec hnologies.
EU manufacturing representative:
umentation for details. For the latest product information, contact
N4131
gital device, pursuant to part 15 of the FCC Rules. These limits are
equency energy and, if not installed
nce could void the user's authority to operate
Hereby,
clares that this device is in compliance with the essential requirements and
www.interlogix.com or
.
2
-003.
-003du
TABLE OF CONTENTS
1. INTRODUCTION .................................................................................................................................................. 4
1.1. PACKAGE CONTENTS......................................................................................................................................... 4
1.2. INTRODUCING LONG REACH POWER OVER ETHERNET ..................................................................................... 5
1.3. PRODUCT FEATURES ......................................................................................................................................... 6
1.4. PRODUCT SPECIFICATIONS ................................................................................................................................ 7
1.4.1. POC252-1CXP-1T Specifications ............................................................................................................ 7
1.4.2. POC252-1CX-1P Specifications .............................................................................................................. 9
2. HARDWARE DESCRIPTION ........................................................................................................................... 11
2.1. POC252-1CXP ............................................................................................................................................... 11
2.1.1. POC252-1CXP Physical Dimensions ..................................................................................................... 11
2.1.2. POC252-1CXP-1T Front Panel / Rear Panel ........................................................................................ 11
2.1.3. POC252-1CXP LED Indicators ............................................................................................................. 12
2.2. POC252-1CX ................................................................................................................................................. 13
2.2.1. POC252-1CX-1P Physical Dimensions ................................................................................................. 13
2.2.2. POC252-1CX Front Panel / Rear Panel ................................................................................................ 14
2.2.3. POC252-1CX LED Indicators ................................................................................................................ 14
3. INSTALLATION ................................................................................................................................................. 15
3.1. INSTALLATION PRECAUTIONS ......................................................................................................................... 15
3.2. POWER OPTIONS: ............................................................................................................................................. 16
3.3. APPLICATIONS OF POC252-KIT WITH COAXIAL CABLE .................................................................................. 17
3.4. OPTIONAL - DIN-RAIL MOUNTING ................................................................................................................. 20
4. TROUBLESHOOTING ....................................................................................................................................... 21
APPENDIX A: NETWORKING CONNECTION .................................................................................................... 22
A.1 SWITCHS RJ45 PIN ASSIGNMENTS ...................................................................................................................... 22
A.2 RJ45 CABLE PIN ASSIGNMENTS ........................................................................................................................... 22
3

1. INTRODUCTION

ing the original packing material, and use
them again to repack the product in case there is a need to return it to us for
Thank you for purchasing IFS PoE over Coaxial the POC252-1CXP and POC252-1CX, consisting of the POC252-1CXP and POC252-1CX. The descriptions of the two models are as follows:
POC252 Power over Coax
POC252-1CXP-1T POC252-1CX-1P
POC252-1CXP/POC252-1CX” mentioned in this Manual represents the above two models.

1.1. Package Contents

Open the box of the POC252-1CXP/POC252-1CX and carefully unpack it. The box should contain the following items:
1-Port 10/100TX PoE PD + 1-Port Coax Long Reach PoE Injector 1-Port 10/100TX PoE PSE + 1-Port Coax Long Reach PoE Extender (Camera End)
For POC252-1CXP-1T/POC252-1CX-1P
1-Port 10/100TX PoE PD + 1-Port
Coax Long Reach PoE Injector –
POC252-1CXP x1
1-Port 10/100TX PoE PSE + 1-Port
Coax Long Reach PoE Extender –
POC252-1CX x1
User's Manual x 1 Warning Sticker x 1
If any of these ar e miss ing or dam aged, ple as e cont act y our de aler i mm ediat ely ; if possible, retain the carton includ
repair.
4

1.2. Introducing Long Reach Power over Ethernet

IFS POC252 series PoE over Coaxial Extender is designed to extend IP Ethernet transmission and inject power over an existing coaxial cable or for distance up to 1000m (3280ft) to PoE IP camera, PoE Wireless AP and any 802.3at device that complies with powered device (PD). It is perfect solution for sending IP Video links and power to remote PoE IP camera installation that are beyond the 100 meters distance limit of Ethernet.
Power over Coaxial Cable Application
The Long Reach PoE solution allows Ethernet Data and PoE or PoE+ to transmitted using coaxial, UTP or twisted-pair cable. Based on IEEE 802.3at Power over Ethernet Plus and up to 25 watts of power output, IFS PoE extender solution eliminates the need for additional remote site power while allowing a single PoE source, such as a PoE network switch, to provide power to both POC Extenders and the camera at long range. This feature eliminates the need for local and remote site power supplies.
Stable Operating Performance under Difficult Environments
The POC252-1CXP and POC252-1CX extender is the perfect solution for extended distance data and power transmission for warehouses, parking lots, campuses, casinos, and many more. They can operate stably under temperature range from -10 to 60 degrees C which enables the users to conveniently apply the device in almost any location of the network.
5

1.3. Product Features

Physical Port
1 coaxial interface for output power and 1 10/100BASE-TX port supports IEEE 802.3at PoE
PD (POC252-1CXP)
1 power jack supports 56V DC Power input (POC252-1CXP)  1 coaxial interface for input and 110/100BASE-TX port supports IEEE 802.3at PoE PSE
(POC252-1CX)
Power over Ethernet
Eliminates Power cabling with PoE over Coaxial  Supports Power over Ethernet PSE, PoE Injector  Power and Ethernet data transmission over coaxial up to 1km  Complies with IEEE 802.3at Power over Ethernet PD on RJ45 port  Supports Long Reach PoE power up to 30.8 watts (Vary on Power Source and Coaxial
Distance)
Supports PoE Power up to 25 watts (Vary on Power Source and Coaxial Distance)  Auto detect remote powered device (PD)  Plug and Play, no PC required
Industrial Case / Installation
Supports extensive LED indicators for network diagnostics  Metal case protection
Compact size, DIN-rail and wall mount designed  Power Input: External 56VDC input or 802.3at PoE power input from RJ45 port
(POC252-1CXP)
Power Input: PoC (Power over Coaxial) power input (POC252-1CX)  Supports EFT protection 2000 VDC for power line  Supports 2000 VDC Ethernet ESD protection  -10 to 60 degrees C operating temperature
6

1.4. Product Specifications

Model
POC252-1CXP-1T / Long Reach PoE Injector
Hardware Specificatio n s
1 x 10/100BASE-TX RJ45 Auto-negotiation/ Auto-MDI/MDI-X
IEEE 802.3at PoE PD (Powered Device) Supports both Mid-Span and End-Span PSE
Data Rate
100/100Mbps
Cabling
Cat5e or above
Maximum Distance
Maximum Frame sizes
1 x BNC female connector
BNC shield : DC - / Lo
41~56V DC (Depend on what is the DC/PoE Power Input and the length of coaxial cable)
Coaxial cable: 75 ohm
RG-59/U cable, less than 30Ω/1000 ft.
distance
Max. 1200M without PoE output (3,937ft.)
Long Reach Ethernet Standard
2 ~ 28 MHz
PoE Output
Capability
PoE+ IN
Supports up to 3 POC extenders within 1km length of coaxial cable)
POC Compatibility

1.4.1. POC252-1CXP-1T Specifications

Copper
Ethernet Interface
Power over Ethernet
Connectivity
Power Output
Cabling
Maximum
Input Range: 56V DC
100m
1522bytes
Long Reach PoE over coaxial PSE (Power Source Equipment)
BNC center pole : DC+ / Hi
RG-6/U cable, less than 12Ω/ 10 00 ft
Max. 1000M with PoE output (3,280ft.)
IEEE 1901
Long Reach PoE Interface
Modulation Type Security Frequency Band
Performance
Multiple nodes
Wavelet-OFDM 128-bit AES encryption
POC252-1CX 802.3at
RG6 Cable Distance
200m 400m 600m 800m
1000m
Data Rate (Upload / Download)
93 / 93 Mbps 29.9W 16.9W 92 / 93 Mbps 22.6W 14.3W 88 / 92 Mbps 13.6W 10.2W 75 / 83 Mbps 10.6W 8.3W 55 / 74 Mbps 8.6W 7.1W
POC252-1CXP W/56V DC IN
POC252-1CX P W/30W
(Depend on what is the DC/PoE Power Input and the
POC252-1CXP-1T with POC Extender
7
4 x LEDs
PWR
LNK/ACT
ESD Protection
2KV DC
Enclosure
IEEE 802.3 10BASE-T Ethernet
IEEE 802.3at Power over Ethernet (802.3a t Ty pe 2)
Operating: -10~60 degrees C Storage: -40~75 degrees C
Operating: 5~95% (Non-condensing) Storage: 5~95% (Non-condensing)
LED Indicators
POC LNK PoE In-use
EFT Protection 2KV
Metal case
Installation Wall mo unt or DIN rail with optional kit Dimensions (W x D x H) 94 x 70 x 26 mm
Weight
200g RJ45 PoE Input: 802.3at 56V DC
Power Requirements
DC Input: 56V DC
Standards Conformance
Standards Compliance
IEEE 802.3u 100BASE-TX Fast Ethernet IEEE 802.3af Power over Ethernet (802.3at Type 1)
Regulation Compliance FCC Part 15 Cla s s A, CE
Environment
Temperature
Humidity
8

1.4.2. POC252-1CX-1P Specifications

Model
POC252-1CX-1P / Long Reach PoE Extender
Hardware Specificatio n s
10/100BASE-TX RJ45 Auto-negotiation/ Auto-MDI/MDI-X
PoE Standard
IEEE 802.3at PoE PSE (Power Source Equipment)
PoE Output
48~56V DC, 600mA max.
PoE Budget
Up to 25 watts
PoE Mode
End-span, RJ45 Pin 1/2(+), 3/6(-)
Data Rate
100/100Mbps
Maximum Distance
Maximum Frame sizes
1 x BNC female
BNC shield : DC - / L o
Coaxial cable: 75 ohm RG-59/U cable, less than 30Ω/1000 ft.
distance
Max. 1200M without PoE output (3,937ft.)
Long Reach
Standard
Wavelet-OFDM
128-bit AES encryption
2 ~ 28 MHz
AES 128-bit
Capability
IN
PoE+ IN
With power over coaxi al input
Switch
Copper
Ethernet Interface
Cabling
Cat5e or above 100M
1522bytes
Long Reach PoE Interface
Connectivity
Long Reach PoE over coaxial PD (Powered Device)
BNC center pole : DC+ / Hi
Power Input 48~56V DC
Cabling
Maximum
Ethernet
RG-6/U cable, less than 12Ω/ 10 00 ft
Max. 1000M with PoE output (3,280ft.)
IEEE 1901
Modulation Type Security Frequency Band Encryption
RG6 Cable Distance*
Data Rate**
(Upload /
Download)
POC252-1CX 802.3at/at PoE Output
POC252-1C XP w/56V DC
POC252-1C XP w/30W
POC2502 w/56V DC
Performance
POC Compatibility
200m 400m 600m 800m
1000m
93 / 93 Mbps 29.9W 16.9W 22W 93 / 92 Mbps 22.6W 14.3W 18W 92 / 88 Mbps 13.6W 10.2W 15W 83 / 75 Mbps 10.6W 8.3W 10W 74 / 55 Mbps 8.6W 7.1W 8W
POC252-1CXP-1T / 1-Port POC Injector POC2502-8CX-2T-2S – 8-Port POC over Coax
Switch
POC252-16CX-2T-2S –16-Port POC over Coax
9
LED Indicators
4 x LEDs
LNK/ACT
ESD Protection
2KV DC
Enclosure
Metal case
Installation
Wall mount or DI N rail with optional kit
Weight
375g
Standards Conformance
IEEE 802.3 10BASE-T Ethernet
IEEE 802.3at Power over Ethernet (802.3a t Ty pe 2)
Regulation Compliance
FCC Part 15 Class A, CE
Environment
Operating: -10~60 degrees C Storage: -40~75 degrees C
Operating: 5~95% (Non-condensing) Storage: 5~95% (Non-condensing)
PWR LRP LNK
Dimensions (W x D x H) 94 x 70 x 26 mm
PoE In-use
Power Requirements
Standards Compliance
Temperature
BNC Power over Coaxial Input: 48~56V DC
IEEE 802.3u 100BASE-TX Fast Ethernet IEEE 802.3af Power over Ethernet (802.3at Type 1)
Humidity
* The actual data rate will vary on the quality of the coaxial cable and environment factors. **Downstream means POC252-Injector to POC252-Extender data rate and Upstream is POC252-Extender to POC252-Injector data rate.
The actual data rate will vary on the quality of the coax cable as well as environmental factors. It is recommended that only the coax cable with the following properties is used.
Coaxial Cable Type
RG-59/U Less than 30Ω/1000 ft. RG-6/U Less than 12Ω/1000 ft
10

2. HARDWARE DESCRIPTION

Figure 2-1: POC252-1CXP Front Panel
Figure 2-2: POC252-1CXP Rear Panel

2.1. POC252-1CXP (Injector)

2.1.1. POC252-1CXP Physical Dimensions

POC252-1CXP-1T dimensions (W x D x H): 94 x 70.3 x 39.2 mm

2.1.2. POC252-1CXP-1T Front Panel / Rear Panel

Figure 2-1 and Figure 2-2 show the front / rear panels of the POC252-1CXP Long Reach PoE over
Coaxial Injector.
11
LED
Color
Function
Power ON: 48~56V DC power input from DC jack
LED
Color
Function
Lit: indicates that the coaxial link is established.
Off
LED
Color
Function
over that port.

2.1.3. POC252-1CXP LED Indicators

System
Power ON: PoE+ / PoE power input from RJ45 PoE PD port
PWR Green
LRP Coaxial Interface
Lit
Off Power Off
LNK Green
RJ45 10/100BASE-TX Interface
PoE IN Amber Lit: indicates the RJ45 port is receiving the PoE Power.
LNK/ACT Green
: indicates that the coaxial link is down.
Blink: indicates the extender is activel y sending or receiving data
12

2.2. POC252-1CX (Extender)

2.2.1. POC252-1CX-1P Physical Dimensions

POC252-1CX-1P dimensions (W x D x H): 94 x 70.3 x 39.2 mm
13

2.2.2. POC252-1CX Front Panel / Rear Panel

LED
Color
Function
LED
Color
Function
Lit
Off: indicates that the coaxial link is down.
LED
Color
Function
over that port.
Figure 2-3 and Figure 2-4 show the front / rear panels of the POC252-1CX Long Reach PoE over Coaxial
Extender.
Figure 2-3: POC252-1CX Front Panel Figure 2-4: POC252-1CX Rear Panel

2.2.3. POC252-1CX LED Indicators

System
PWR Green Lit: indicates the power is on.
LRP Coaxial Interface
LNK Green
RJ45 10/100BASE-TX Interface
PoE In-Use Amber Lit: indicates the RJ45 Port is providing PoE power
: indicates that the coaxial link is established.
LNK/ACT Green
Blink: indicates the extender is actively sending or receiving data
14

3. INSTALLATION

This section describes the functionalities of the POC252-1CXP/POC252-1CX components and guides you to how to install it on the desktop. Basic knowledge of networking is expected. Please read this chapter completely before continuing.

3.1. Installation Precautions

As the POC252-1CXP is power over coaxial injector, it only can work with IFS power over coaxial extender, the POC252-1CX. Please confirm that other Non-PoE equipment is not connected with the coaxial cable. When you connect the coaxial cable with coax-LAN converter, CCTV camera, etc, it might cause other equipment to damage. DO NOT CONNECT DIRECTLY TO AN ANALOG CAMERA AS IT WILL DAMAGE THE CAMERA BY APPLYING VOLTAGE TO THE ANALOG OUTPUT.
The package contains one Warning Sticker, which should be stuck on the coaxial cable connector before using IFS PoE over Coaxial Extender Kit.
15

3.2. Power options:

POC252-1CXP Injector There are two ways to power the POC252-Injector
Powered via PoE Powered via DC adapter
POC252-1CX
The POC252-Extender must be powered by the POC252-Injector or POE Switch
POC252-1CX must be powered by the POC252-1CXP or POC2502 POC switch
over the coaxial cable.
Please don’t connect the POC252-Extender to a PoE PSE.
16

3.3. Applications of POC252-KIT with coaxial cable

POC252 Injector
POC252 Extender
POC252-1CXP
POC252-1CX
Input
Output
output
The other
Type 1 – One POC252-1CXP with PoE power input and one POC252-1CX with PoE
power output
The POC252-Injector is powered via IEEE 802.3at PoE. An IEEE 802.3at compliant PoE PD will automatically be powered by the POC252-Extender via UTP.
Functions
Power
Power
RJ45 with 802.3at PoE input BNC with DC power over coaxial input BNC with DC power over coaxial
Installation Instructions
Step 1
Step 2
Step 3
Connect the POC252-Injector (POC252-1CXP) and POC252-Extender (POC252-1CX) to ends of BNC terminated coaxial cable. Stuck the “Warning Stacker” on the coaxial cable.
Connect CAT5/6 UTP cable to POC252-1CXP and IEEE 802.3at compliant PoE Switch or PoE Injector. If the PoE switch or PoE injector is powered on already, then the PWR LED of POC252-1CXP and POC252-1CX should lit up immediately.
Connect CAT5/6 UTP cable to POC252-1CX and IEEE 802.3at complied PoE IP camera or PoE Wireless AP.
RJ45 with 802.3at PoE output
The POC252-1CXP accepts IEEE 802.3at equipment for optimal power injection.
Non-standard PoE Power devices may cause the POC252-1CXP to be damaged.
17
Type 2 One POC252-1CXP with 56V power adapter and one POC252-1CX with PoE
LRP Injector
LRP Extender
POC252-1CXP
POC252-1CX
power socket, then the
power output
The POC252-Injector is powered via the external power adapter. The IEEE 802.3at compliant PoE PD will automatically be powered by the POC252-Extender via UTP.
Power Input
Power Output
Power adapter with 48~56V DC in
BNC with DC power over
coaxial output
Installation Instructions
Connect the POC252-Injector (POC252-1CXP) and POC252-Extender
Step 1
Step 2
Step 3
Step 4
(POC252-1CX) to ends of BNC terminated coaxial cable. Stick the “Warning Sticker” on the coaxial cable.
Connect CAT5/6 UTP cable to POC252-1CXP and non-PoE switch or workstation.
Connect 48~56V DC power adapter to POC252-1CXP PWR LED of POC252-1CXP and POC252-1CX should lit up immediately.
Connect CAT5/6 UTP cable to POC252-1CX and IEEE 802.3at complied PoE IP camera or PoE Wireless AP.
BNC with DC power over coaxial input
RJ45 with 802.3at PoE output
1. PoE output capacity is based on different DC Power Input / PoE Input.
2. POC252-1CXP has two power input options; only one mode is available at one time. It
cannot use PoE power input if power input of DC 52V or 56V is selected.
18
Type 2 One POC252-1CXP with 56V power adapter and two POC252-1CX with PoE
power output for two cameras.
19

3.4. Optional - DIN-Rail Mounting

mounting brackets. Damage caused to the
There are two DIN-Rail holes on the left side of the POC252-1CXP/POC252-1CX that allow the device can be easily installed with DIN-Rail mounting. The PLANET optional DIN-Rail mounting Kit – RKE-DIN can be order separately. When need to replace the wall mount application with DIN-Rail application on the POC252-1CXP/POC252-1CX, please refer to following figures to screw the DIN-Rail on the converter. To hang the POC252-1CXP/POC252-1CX, follow the below steps:
Step 1: screw the DIN-Rail on the POC252-1CXP/POC252-1CX.
Step 2: Lightly press the button of DIN-Rail into the track.
Step 3: Check the DIN-Rail is tightly on the track.
You must use the screws supplied with the parts by using incorrect screws would invalidate your warranty.
20

4. TROUBLESHOOTING

This chapter contains information to help you sol ve issues. If the POC252-1CXP/POC252-1CX is not functioning properly, make sure the POC252-1CXP/POC252-1CX is set up according to instructions in this manual.
The maximum distance support by POC252-1CXP/POC252-1CX
Solution:
1. The POC252-1CXP/POC252-1CX supports maximum distance of 1km (Data plus Power transmission).
What power source can used by POC252-1CXP?
Solution:
1. DC 56V power adapter.
2. DC 48V power adapter.
3. IEEE 802.3at High Power over Ethernet Switch.
4. IEEE 802.3af Power over Ethernet Switch.

The POC252-1CXP/POC252-1CX Performance is bad

Solution:
The actual data rate will vary on the quality of the coaxial / UT P cable and environment factors.
Make sure the BNC connector is in good condition.
If the BNC connector is loose it may affect performance with poor ground.
21

APPENDIX A: NETWORKING CONNECTION

RJ45 Connector pin assignment
Interface
Interface-Cross
1
Tx + (transmit)
Rx + (receive)
Positive (VCC+)
2
Tx - (transmit)
Rx - (receive)
Positive (VCC+)
3
Rx + (receive)
Tx + (transmit)
Negative (VCC-)
4, 5
Not used
Not used
6
Rx - (receive)
Tx - (transmit)
Negative (VCC-)
7, 8
Not used
Not used

A.1 Switch’s RJ45 Pin Assignments

10/100Mbps, 10/100BASE-TX
Contact MDI
Media Dependant
Media Dependant

A.2 RJ45 Cable Pin Assignments

MDI-X
PoE
The standard RJ45 receptacle/connector
22
There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the
Straight Cable
SIDE 1
SIDE2
1 2 3 4 5 6 7 8
1 2 3 4 5
6
7 8
SIDE 1
1 = White / Orange
1 = White / Orange
SIDE 2
Crossover Cable
SIDE 1
SIDE2
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
SIDE 1
1 = White / Orange
1 = White / Green
SIDE 2
pin allocation and color of straight cable and crossover cable connection:
2 = Orange 3 = White / Green 4 = Blue 5 = White / Blue 6 = Green
Figure A-1: Straight-through and Crossover Cable
7 = White / Brown 8 = Brown
2 = Orange 3 = White / Green 4 = Blue 5 = White / Blue 6 = Green 7 = White / Brown 8 = Brown
2 = Orange 3 = White / Green 4 = Blue 5 = White / Blue 6 = Green 7 = White / Brown 8 = Brown
2 = Green 3 = White / Orange 4 = Blue 5 = White / Blue 6 = Orange 7 = White / Brown 8 = Brown
Please make sure your connected cables are with the same pin assignment and color as the above picture before deploying the cables into your network.
Information on FAQ:
WWW.Interlogix.com
Customer Support:
WWW.Interlogix.com/support
23
Loading...