Intrusion
NetworX
Ethernet Module
Overview
The NetworX Ethernet Module brings new functionality to the world
of controls with Ethernet connectivity to your central station. Working
in conjunction with the Osborne-Hoffman Network Receiver, a direct
pipe is established into your current automation.
The module can send events to two IP addresses for dual, split or
backup reporting. Events may also be sent to two e-mail addresses.
The NetworX control panel can also be configured for dial or cellular
backup should network communications fail. Triple-DES encryption
is used to protect data from being compromised. To further enhance
network security, a dynamic KEY generation is employed with a new
24-byte random number generated for every event.
The module also offers the choice of static IP, where the IP
addresses are fixed and assigned by IS department; or DHCP,
where a pool of IP addresses is assigned by a server to units on
the network and IP addresses here can and do change. Either
way, all functions are programmable via keypad or DL900 upload/
download software.
Standa r d Fe atureS
Specifications
Compatible control panels NX-4V2, NX-6V2, NX-8V2, NX-8, NX-8E
Operating power 12VDC supplied from the control panel
Current draw
Operating temperature 32ºF~120ºF (0ºC~49ºC)
Dimensions 6.0 x 3.25 x 1.0 in. (152 x 83 x 25mm)
Shipping weight 1 lb. (454 g)
UL listings UL294 Access Control System Units
120mA during communication,
90mA standby
UL1610 Grade B and C Central-Station
Burglar Alarm Units
UL1635 Digital Alarm Communicator
System Units
UL609 Local Burglar Alarm Units
and Systems
UL3765 Police-Station-Connected
Burglar Alarm Units and Systems
Ordering Information
NX-590NE
NetworX Ethernet-Connected Network Module for
Central Stations
• Up to 1,000 NX-590NEs can be monitored on the Osborne-
Hoffman Network Receiver
• Backwards compatible to all NetworX controls and resides
in a 6-inch slot in the control cabinet
• Provides 10/100BASE-TX Ethernet connectivity with TCP/IP
• On-site or remote-initiated download using DL900 software
• Code updates for NX-590NE can be downloaded and
flashed into modules over the network
• Uses SIA or Contact ID reporting formats
• Installer-selectable polling time for full supervision
• Low current draw of 90mA in standby and 120mA during
communication at 12VDC from NX control panel
• Small bandwidth used with typical message (20 bytes)
North America
T 855-286-8889
Latin America
T 561-998-6114
interlogix.com
Specifications subject to change without notice.
© 2014 United Technologies Corporation.
All rights reserved.
Interlogix is part of UTC Building & Industrial Systems,
a unit of United Technologies Corporation.
306-3679 2014/04 (75049)